| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.3 L+₹4.4 L (13.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.5 L+₹4.6 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹39.7 L+₹5.8 L (17.2%)Rejected-Finance AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹39.9 L+₹6.1 L (17.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
7 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Tezpur
GE (North) Tezpur, c/o 99 APO
SPL REPAIRS TO BLDG NO T-32 AND OTHER REV / MINOR WORKS AT NAA UNDER GE (NORTH) TEZPUR
2023_MES_608435_1
GE(N)/TEZ/2023-2024/8747
Open Tender
Civil Works
Item Rate
180 days
GE (North) Tezpur
As per tender documents
8 documents required · 8 mandatory
₹500
GE (North) Tezpur
₹93,000
11 Sept 2023
10 Jul 2023
14 Aug 2023
10 Jul 2023
7 Aug 2023
24 Jul 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed.
Dismantling timber scantlings in framed works, 40 sqcm and over in section, in any position complete all as specified and as directed.
M&L for lowering of existing truss of wooden/steel section and after repairing and refixed complete all as specified and directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Taking down cement plaster of any thickness and description on brick/concrete/stone walls, ceilings, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement mortar (one side only measured in cases where both sides are plastered complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry laid dry complete all as specified and directed.
Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet 0.50 mm thick of and colour having tensile strengh of 550 Mpa as in ridge, eaves sheet/board covering, valley gutter or of similar type, fixed with self tapping screws with bitumen washer to truss members of any material, complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using Fe-410W (Grade E-250 quality "A") including necessary welding complete complete all as specified and directed.
M&L in repair for second class HW scantalling, wrought, in any position for framed work , jointing with necessary nails, nut bolts etc including necessary supports for truss structure complete all as specified and directed.
S&F 2nd class Hard wood scanttlings, wrought in any position for framed work jointing wirh nails, screws, nut bolt etc. including necessary supports to existing truss including Dismantling of timber scanttlings 40 Sqcm & over in section, in any position for framed workcomplete all as specified and directed.
S&F rolled section as in framing for door/vent/CB/chowkhats, wind tie and the like using angle, tee, hollow tubes etc., cleat and connecting plates complete (Butt hinges shall be measured and paid for separately) using Fe 410-W (Gde-E-250) quality "A" complete all as specified and directed.
S&F framed work such as grills, gratings,etc with ends of bars shouldered and /or riveted, or forged into spikes framed guard bars barred iron doors , laddersand similar work conforming to Fe 410-0 or FE310-0 complete all as specified and directed.
S&F 30mm thick second class HW glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc,sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed.
Providing and fixing factory made uPVC colour casement windows (Outward /inward) with hinges system made of extruded profiles. Profiles of frames 60mm X 58mm and sash (style and rail) 60mm X 78 mm will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware, EPDM gasket, 1.2+0.2.mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, all complete and as directed, (Glazing, hardware hinges and fitting, EPDM rubber gasketetc. to be paid separately.) Note:-Each member of window to be measured separately with clear length.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F 75 mm size butt hinges, extruded aluminium alloy with brass wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 125A22 as per IS 205: 1992 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
S&F 100mm size mild steel butt hinges complete all as specified and directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old decorated wooden surfaces with pre mixed wood filler used as putty of grith exc 10cm and applying two coats of synthetic enamel paint complete all as specified and directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
M&L for preparation of old undecorated steel surfaces with pre mixed steel filler used as putty and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new plastered or undecorated surfaces of wall using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall after complete scrapping down and using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for preparation of new surface of plastered wall using wall care putty to fill the voids and applying two coats of oil bound distemper and finished another one coat with spunge roller over including one coat of alkali resistant priming paint before distempering complete all as specified and directed.
M&L for preparation of old decorated surfaces including washing, rubbing down and stopping of white wash surfaces of walls (Plastered or un-plastered) including cormices pilasters etc and using wall care putty to fill the voids and applying two coats of oil bound distemper and finished another one coat with spunge roller including one coat of alkali resistant priming paint before distempering complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 15mm thick cement plaster in cm 1:4 on fair faces brick or concrete surfaces using water proofing compound of wall (WPC added only 5 mm thick plaster) including finished even and smooth without using extra cement complete all as specified and as directed.(WPC Shall be paid and meassured separately)
M & L for rendering/plastering 15 mm thick in cement mortar 1:6 on faces of brick or concrete surfaces and finished the surface even and smooth without using extra cement complete in all respect as specifified and directed.
Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L 15mm thick plastering on wall in cement mortar (1:6) finished even and smooth without using extra cement on other side of lathing or stone masonary surface other than fair face on other side of lathing complete in all respect as specifified and directed.
S & F hexagonal wire netting, size of aperture 13 mm, dia of galvanised steel wire 0.90 mm as per IS 3150: 1982 fixed with tinned tacks of wire staples complete all as specified and as directed.
M & L for forming Construction joint 30 mm deep x 10 mm wide filled with sealing compound Grade "A" after priming the contact surfaces using suitable primer complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular or triangular in section, clean sawn, secured with screw, area exceeding 13 sqcm but not exceeding 25 sqcm including taking down complete all as specified and as directed.
Supply and Fix exposed GI powder coated snap grid frame work for false ceiling in flat or in sloping , of grid size 600x600mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with 4mm dia GI wire as suspender and including 4mm thick decorative pre -painted non asbestos board (E-Board) in false ceiling including fixing arrangement from steel/wooden truss of any type including dismantalling of existing false ceiling complete all as specified and directed. (Make: Eternit, Everest or equivalent)
Providing and laying coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white cement with pigment to match the tile colour over 15mm thick screed bed in cement mortar (1:6) including dismantling of floor tiles including cement mortar bedding of any thickness upto PCC/RCC surface and rubbish off the premises complete in all respect as specifified and directed.
Providing and laying coloured ceramic tiles 7 to 8mm mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 Sqm in skirting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 10mm thick rendering in cement mortar (1:4) including dismantling of wall tiles including cement mortar bedding of any thickness upto PCC/RCC/brick surface and rubbish off the premises complete in all respect as specifified and directed.
Providing and laying plinth protection of 75mm thick cement concrete (1:3:6) type C-1, (using 20mm nominal size crushed and graded stone aggregate), laid in alternate penals/bays and finished the surafce even and smooth without using extra cement complete all as specified and as directed.
S & F 20 mm dia harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm 1:3:6 type C2 ( using 40 mm graded stone aggregate) as plinth protection/paving finish even and smooth without using extra cement complete all as specified and directed
S&F of new plate rack made out of stainless steel sheet of 0.5 mm thick with overall size 760 mm (H) x 900 mm (W) x 250 mm (D) with three shelves complete all as specified and directed.
Providing and fixing in position kitchen cup board box type as per design and directed of 550-600mm deep, fixed over wall with PVC gittie and screws/or in beneath of kitchen counter, cup board, kitchen cabinet in required sizes as per site made out of 17-18mm thick one side decorative lamination and other side balancing lamination sheet consisting of carcass 17-18mm thick PVC sheet. Provision of shelves, shutters, back side, top, bottom, side, made out of 17-18mm thick one side decorative laminated PVC sheet , all required brackets, screws etc,. The panel shall be fabricated using adhesives and screws whereever required. All the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per maufactures specifications and drawing including 15mmX20mm medium grade chrome finish two nos per leaf, slip on cabinet hinge/self-closing hinge, soft close hydraulic 4 hole cabinet auto cup hinge full overlay O crank with soft closing of make Godrej/Avis L Bihari/Hettich/Harrison and 50mm SS handle size all items each per shutter including taking down of existing box complete in all respect as specified and directed. Make: Rajshri Plastiwood, Sintex or of appd make. (Note: For payment, measurement shall be taken as front portion of cup board measurement only, rest other items/materials as specified shall not be measured or paid as these are included in this item)
Providing and fixing in position kitchen cup board box type as per design and directed of 250-300mm deep, fixed over wall with PVC gittie and screws/or in beneath of kitchen counter, cup board, kitchen cabinet in required sizes as per site made out of 17-18mm thick one side decorative lamination and other side balancing lamination sheet consisting of carcass 17-18mm thick PVC sheet. Provision of shelves, shutters, back side, top, bottom, side, made out of 17-18mm thick one side decorative laminated PVC sheet , all required brackets, screws etc,. The panel shall be fabricated using adhesives and screws whereever required. All the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per maufactures specifications and drawing including 15mmX20mm medium grade chrome finish two nos per leaf, slip on cabinet hinge/self-closing hinge, soft close hydraulic 4 hole cabinet auto cup hinge full overlay O crank with soft closing of make Godrej/Avis L Bihari/Hettich/Harrison and 50mm SS handle size all items each per shutter including taking down of existing box complete in all respect as specified and directed. Make: Rajshri Plastiwood, Sintex or of appd make. (Note: For payment, measurement shall be taken as front portion of cup board measurement only, rest other items/materials as specified shall not be measured or paid as these are included in this item)
M & L for coloured non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement with pigment to match the tile colour complete in all respect as specified and directed.
M&L for coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile colour complete in all respect as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality "A") complete all as specified and directed.
Spreading and levelling in layers not exceeding 25 cm thick complete all as specified and as directed.
M & L for 40 mm thick damp proof course in cement concrete M15(Nominal mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with integral water proofing compound to horizontal or vertical surfaces including necessary formworks complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
M&L for plinth protection or in foot path of 75 mm thick of cement concrete using type C-1, 1:3:6 (using 20 mm nominal size crushed and graded stone aggregate) in alternate penals and finished fair and even complete in all respect as specified and directed.
M&L for 18-20mm thick machine cut kota stone slab flooring of size not less than 500x500mm over 20mm thick cement mortar (1:6) cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M&L for 18-20mm thick machine cut kota stone slab flooring of size not less than 500x500mm in riser of steps, skirting, dado and pillar over 15mm thick cement mortar (1:4) cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
M & L for rendering/plastering 10mm thick in cement mortar 1:3 on faces of brick or concrete surfaces and finished the surface even and smooth without using extra with water proofing compound over chajja, coping etc complete in all respect as specifified and directed. (Water proofing compound shall be measured and paid under supply item only)
Supply only integral water proofing compound complete all as specified and as directed.
M & L for mild steel iron frame for door , window using joist, channel, angle, tee, tubes, flat sections, fixed independently, without connecting plates, etc. conforming to Fe. 290., Gde-E-165 complete in all respect as specifified and directed.(MS hinge shall be paid under supply only item)
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed.
M & L for preparation of new plastered surface of wall and applying two coats of weather coat over two coat of home shield over 3mm thick (in two layers), wall care putty over a coat of primer complete in all respect as specifified and directed.
M&L for preparation of newly undecorated plastered surface of wall and applying two coats of oil bound distemper (OBD) and finished with spunge roller over a coat of alkali resistant priming paint over 3mm thick (in two layers), wall care putty complete in all respect as specifified and directed.
Preparation of newly plastered surfaces on ceilings and applying two coats of white wash complete all as specified and as directed.
S & F mild steel sliding door bolts, type I (plate type), size 250 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
M & L for writing letters or figures in (Roman/ Indic Script) (Bold/ Italic/ Capital/ Smaller type) not exceeding 30 cm in height with synthetic enamel paint complete all as specified and as directed.
Providing and laying 60 mm thick coloured glazed rubber mould, pre-coated interlocking or without interlocking paver block of any shape and size conforming to IS 15658-2006 with upto date amendments, M-35 Grade with grey cement with pigment laid over river bed fine sand etc complete all as specified and directed. (Note : River bed sand shall be measured and paid seperately) sample shall be approved by GE.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed.
M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings etc. complete all as specified and as directed.
Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting agle iron, roof top MS sheets, railings etc omplete all as spcified and directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down main switch/MCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
M & L for point wiring for light point/fan point/bell point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH unsheathed multi stranded copper conductor cable 1100 Volts grade single core conforming to IS-694-2010 and one run of continous earth wire with 1.50 Sqmm stranded core PVC insulated unsheathed copper conductor cable draw in & including (Medium mechanical strength , ISI marked) not less than 25 mm wide double lock type to be fixed with the help of rawal plugs & screws including necessary fittings & fixtures and including PVC terminal box and PVC board ISI marked making good disturbed surface with CM (1:4) to match with the existing surface.
All as per item 104 above but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and directed.
All as per item 104 above but for 3 pin 16 Amps switch socket combination on independent board with 2.5 sq mm copper cable complete all as specified and directed.
All as per item 104 above but for 5 Amps socket point on the same board controlled by one switch complete all as specified and directed.
All as per item No.104 above but with 2.5 sqmm single core multistranded copper conductor cable for 4x1 number 3/5 pin 5/6 Amp socket outlet on independent board complete all as specified and as directed. (Note switch socket will be measure and paid seperately).
S & F switch socket combination out let 2 in one/3 pin , 5/6 Amps, flush type 240 volt , AC 50 Hz complete all as specified and directed. (Make :- Havells Cat no/SAP code - AHETOXG202 or equivalent in Legrand / Schneider)”
S & F switch socket combination out let 2 in one/6 pin , 6/16 Amps, flush type 240 volt , AC 50 Hz complete all as specified and directed. (Make :- Havells Cat no/SAP code - AHETOFG202 or equivalent in Legrand / Schneider
S & F socket outlet 5/6A 3/5pin ,240 volt , AC , 50 Hz flush type control by another 5/6 Amp switch complete all as specified and directed.(Make - Havells Cat no/SAP code:- AHEKXOW063 of REO or equivalent in Legrand/schneider).
S & F switch piano 5/6A one way ,240 volt , AC , 50 Hz flush type complete all as specified and directed.(Make - Havells Cat no/SAP code:- AHESEXW061 of REO or equivalent in Legrand/schneider
S & F step type electronic fan regulator , capacitor type , 100/120 watt , 240 watt , 50 Hz , single phase , flush type complete all as specified.(Make :- Havells Cat no/SAP code – AHERFXW002 or equivalent in Legrand / Schneider)
S & F ceiling rose 6A ,240 volt , surface type , intended to support mechanical load by means of flexible coard having provision for the connectionof switch wiring , polycarbonate type three terminals complete all as specified and directed.(Make :- Havells Cat no/SAP code – AHEEUXW002 or equivalent in Legrand / Schneider)
S & F lamp holder (Angle Holder), PVC/Polycarbonate type with cord grip cap suitable for pendent fitting complete all as specified.(Make :- Havells Cat no/SAP code – AHEHQMW000 or equivalent in Legrand / Schneider)
S & F LED bulb 10 watt B22 type emergency inverter type rechargable(4 hr backup) with lumen output 950 lm and color temp 6500K suitable for bulb holder complete all as specified and diirected.(Make :- Philips model Stellarbright or equivalent in Wipro / Crompton)
M&L for sheet metal enclosure MCB DBs SPN , 12 way 240 V, with 100 A rated bus bar , double door, IP 43 as per IEC 61439-3 , suitable for flush mounting and surface mounting complete all as specified and as directed. (Make:- Legrand series 5076 12 or equivalent in L & T / Schnieder)
M & L for MCB SP 6-32 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 complete all as specified and directed.(Make :- Legrand series 4085 87 to 4085 95 or equivalent in L & T / Schnieder)
Supply and draw submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduit including 6 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted.
M & L for MCB SPN 40 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 complete all as specified and directed.(Make :- Legrand series 4086 18 or equivalent in L & T / Schnieder)
M & L for reparing/rewinding of u/s ceiling fan/exhaust of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and painting one coat of synthetic enamel paint of approved quality and colour (spray painted) after preparing the surface throughly and refixing at site at same/different location and connection complete from ceiling rose with new flexible chord of copper of suitable size, testing commissioning after completion of the work.[Note:- (1) Rewinding of fans included in this quoted rate.(2) U/s fan(ceiling or exhaust) will be issued by department /user].
S&F in replacement LED Tube light luminaires, 22 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of from connector and ceiling rose, complete all as specified and directed. (Make :- Philips model SmartBright or equivalent in Wipro / Crompton)
Supply & Fix LED wall security lights 30 watt new generation energy saving environmental friendly made up of pressure die cast aluminium housing with high efficiency ,IP 66 protection with necessary brackets (made out of 20/25mm bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls complete all as specified and directed. (Make:- Philips Cat no-BRP046 LED 30 CW MR S1 PSU GR or Equivalent in Wipro/Crompton)
M & L for Earthing with galvanised steel pipe electrode, 40 mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4 mm dia galvanised iron or steel wire all as shown in Plate No. 2 ( SSR Part-1) to the earthing test point all as specified and indicated , necessary excavation any type of soil, CI chamber cover 10 mm with 6 mm rod , wire mess, funnel, test point, 20 mm dia GI protection pipe medium grade etc complete and testing on completion all as specified and directed by Engr-in-charge (4 mm wire lead upto 7.5 RM will be included in the item rate . (Note :- Fresh agriculture soil / black dirt or soil with a high organic conten will be used for filling the dug as required when rocky /sandy soil found at site to achieve the desired resistance from out side without any extra cost.
M & L for point wiring with 1.5 sqmm FRLSH, PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade (MMS ISI) of size not less than 20 mm dia(or as site requirement) concealed in wall/over ceiling, pressed steel concealed terminal boxes of required size and with top cover 3 mm thick of plastic laminated sheet of reqd colour, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified including 1.5 sqmm FRLSH PVC insulated sheathed multistranded copper earth conductor to common earth and connected to earth dolly for light / fan/ bell point controlled by one switch. Note:- (i) Cost of PVC conduit, steel terminal boxes, plastic laminated sheet cover etc; are deemed to be included in the quoted rate. (ii) M&L for cutting chases on walls / ceiling and making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate.
All as per item no. 125 above but for 5 Amps Socket point on independent board with 1.5 sqmm copper cable complete all as specified and as directed.
All as per item no. 125 above but for 5 Amps Socket point on same board controlled by one switch complete all as specified and as directed.
All as per item no. 125 above but for 15 Amps Socket point on independent board with 2.5 sqmm copper cable complete all as specified and as directed.
M&L for sheet metal enclosure MCB DBs SPN , 8 way 240 V, with 100 A rated copper bus bar , double door, IP 43 as per IEC 61439-3 , suitable for flush mounting and surface mounting complete all as specified and as directed. (Make:- Legrand series 5076 10 to 15 or equivalent in L & T / Schnieder)
M & L for MCB SPN 32 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 complete all as specified and directed.(Make :- Legrand series 4086 17 or equivalent in L & T / Schnieder)
Supply and fix energy saving ceiling fan 1200 mm sweep, BEE 5 star rated (BLDC),without remote , minimum air delivery 228 cmm , working voltage 140 volt to 270 volt , minimum rpm 350 , ISI marked , including necessary hanging arrangement , providing three core flexible copper conductor wire of size 23/0.0076 from ceiling rose to fan complete all as directed by Engr-in-Charge.(Make:- Orient I series Hector 500)
Supply and fix exhaust fan 300 mm sweep, 1400 rpm ISI marked with metal blade and louver complete fixed in wall with fastener complete all as directed by Engr-in-Charge. (Make:- USHA S.PH Turbo HDEF 1400 RPM ISI)
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supplying & fixing to walls and ceilings or laid in floors 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
M&L for boring manually (upto 80 mm dia pipe) under road/path for laying of cable complete all as specified and directed.
S & F GI wire netting 0.90 mm dia and 13 mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed.
M/S JIWA SINGH S GILL
M/S UDIPTA KUMAR BORAH
Ms N D Enterpise
M/S S.K. Sharma
Anil Kumar Sarmah
shyam constructions
M/S Bharat Construction Co.
M/S PK ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .