| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹34.0 L+₹6.2 L (22.4%)Rejected-Finance | L2 | Rejected-Finance Rejected being |
| Sl No | Description | Qty | Unit | V K Constructive Builders L2 | singh traders L1 |
|---|---|---|---|---|---|
| 1.00 | Schedule 'A' Part-I (B/R itmes)
Demolition of reinforced cement concrete for roofs, floor, beams, staircases, landing ,chajjas and similar susended work, complete all as specified and as directed. (Reinforcement cut to facilitate demolition) | 27 | Cubic metre | 200 ₹5,400 Lowest | 200 ₹5,400 Lowest |
| 2.00 | Material and labour reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete , complete all as specified and directed. | 14 | Cubic metre | 7,000 ₹98,000 | 5,500 ₹77,000 Lowest |
| 3.00 | Material & Labour for Reinforced cement concrete design mix M-25 using 20mm graded stone aggregate, as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the likedack slab , complete all as specified and directed. | 27 | Cubic metre | 8,500 ₹2,29,500 | 5,500 ₹1,48,500 Lowest |
| 4.00 | Material and labour reinforced cement concrete M-25 (design Mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span , complete all as specified and directed. | 14 | Cubic metre | 8,500 ₹1,19,000 | 5,500 ₹77,000 Lowest |
| 5.00 | Material and labour formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete , complete all as specified and directed. | 20 | Square Metre | 300 ₹6,000 | 200 ₹4,000 Lowest |
| 6.00 | Material & Labour form work to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 centimetre thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and directed. | 170 | Square metre | 400 ₹68,000 | 200 ₹34,000 Lowest |
| 7.00 | Material and labour form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc., also splays between floors and beams, etc., work in rough finished flat surfaces of concrete , complete all as specified and directed. | 30 | Square Metre | 400 ₹12,000 | 200 ₹6,000 Lowest |
| 8.00 | Material & Labour TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia , complete all as specified and directed. | 5,000 | Kilogram | 100 ₹5,00,000 | 81 ₹4,05,000 Lowest |
| 9.00 | Material and labour TMT steel bars 5mm dia and over up to and including 10mm dia in stirrups, spacers etc, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia, complete all as specified and directed. | 2,000 | Kilogram | 100 ₹2,00,000 | 81 ₹1,62,000 Lowest |
| 10.00 | Dismentling of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles , complete, all as specified and as directed. | 90 | Cubic metre | 300 ₹27,000 | 200 ₹18,000 Lowest |
Tender Value
₹33.5 L
EMD Value
₹67,040
Closing Date
20 Jan 2026, 6:00 pmClosed
GE(N) AMBALA CANTT
GE(N) AMBALA CANTT
CA NO GE(N)AMB-73/2025-26 SPL REPAIR TO BUILDING NO 31/1,31/2 AND 31/3 CHILLIANWALA LINES, AMBALA CANTT FOR STAFF LIVING OF GIRLS BN NCC OF AGE B/R-I OF GE (NORTH) AMBALA CANTT
2025_MES_746539_1
GE(N)/AMB-73/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE(N) AMBALA CANTT
As per tender document
9 documents required · 9 mandatory
₹500
GE (N) AMBALA CANTT
₹67,040
Yes
10 Apr 2026
30 Dec 2025
22 Jan 2026
30 Dec 2025
20 Jan 2026
13 Jan 2026
30 Dec 2025 - 13 Jan 2026
Schedule 'A' Part-I (B/R itmes) Demolition of reinforced cement concrete for roofs, floor, beams, staircases, landing ,chajjas and similar susended work, complete all as specified and as directed. (Reinforcement cut to facilitate demolition)
Material and labour reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete , complete all as specified and directed.
Material & Labour for Reinforced cement concrete design mix M-25 using 20mm graded stone aggregate, as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the likedack slab , complete all as specified and directed.
Material and labour reinforced cement concrete M-25 (design Mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span , complete all as specified and directed.
Material and labour formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete , complete all as specified and directed.
Material & Labour form work to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 centimetre thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and directed.
Material and labour form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc., also splays between floors and beams, etc., work in rough finished flat surfaces of concrete , complete all as specified and directed.
Material & Labour TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia , complete all as specified and directed.
Material and labour TMT steel bars 5mm dia and over up to and including 10mm dia in stirrups, spacers etc, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia, complete all as specified and directed.
Dismentling of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles , complete, all as specified and as directed.
Material & Labour brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 , complete, all as specified and as directed.
Material and labour rendering 15 mm thick on brick work or concrete wall surfaces in cement mortar (1:4) and surface finished even and smooth without using extra cement complete all as specified and as directed
Material and labour for rendering 15 mm thick on any type of faces of brick work or concrete wall surfaces, etc. in cement mortar (1:6) and finished even and smooth without using extra cement , complete all as specified and directed.
Material and labour for rendering 10 mm thick on any faces of brick work or concrete ceiling surfaces in cement mortar (1:3) and finishing the surface even and smooth without using extra cement , complete all as specified and directed.
Material and labour for preparation of new plaster surface on walls and applying two coats of cement based paint over a coat of alkali resistant primer , complete all as specified and directed.
Material and labour for preparation of new plastered /concrete surface of wall applying of two coats of acrylic distemper over a coat of primer complete, all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed.
Material & Labour for non–skid ceramic colour tiles 7 to 8mm thick (square /rectangular) area of each tiles exc 0.11 sqm but n exe 0.18 sqm, in floor etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
Material and labour for glazed ceramic coloured tiles joint free premium/1st quality in vertical surfaces/skirtings/dados of size 300x 600x7mm to 8mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on faces of brick / concrete surfaces in cement mortar 1:4 , complete all as specified and directed.
Material & Labour non skid coloured ceramic tiles 7 to 8 mm thick, (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
Material & Labour PCC 1:2:4, type B–0 (using 12.50mm graded crushed stone aggregates) for levelling of floor finishes such as tiles etc complete all as specified and directed.
Material and labour for 8 to 10mm thick heavy duty (digital) vitrified coloured paver tiles of size 300mm x 300mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:4) , complete all as specified and as directed Make: Endura of Johnson or Durastone of Somany or equivalent make given in App ‘B’
Material & Labour for providing 75 mm thick cement concrete 1:3:6, type C–1 (using 20mm graded crushed stone aggregates) as in plinth protection laid in alternate bays (n exc 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including demolition of old cement concrete complete all as specified.
Demolition of cement concrete (un–reinforced) in ground floors and pavings not exe 15 cm thickness (below or above ground level) , complete all as specified and directed.
Material and labour 100 mm thick PCC 1:4:8 Type D–2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement , complete all as specified and directed.
Material and labour for vibratory rubber moulded coloured precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006, ISI marked of 60 mm thickness, grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick , complete all as specified and directed.
Material and labour for providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, padding, rounded or chamfered on edges including from work where ever required , complete, all as specified and as directed.
Material & Labour rendering 10 mm thick on existing concrete surface of roof in cement mortar 1:4 including mixing water proofing compound @ 3% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-charge. (Note:- WPC shall be measured & paid separately)
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-charge.
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bituminous primer @ 0.40 litre /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temperature and viscosity 70–160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc. after preparing the surface complete as per standred practice as per manufacture's instructions. The vital physical and chemical parameters of the membrane shell be under :– (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d–5147) (iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only , complete, all as specified and as directed. (iv) The work shall be carriout at a height upto 12 metre.
Material & Labour for Cement concrete tiles 30cm x 30cm x 20mm thick, machine pressed; set jointed , grouted and pointed in neat cement slurry on roof top complete all as specified and as directed by the Engineer-in-charge.
Material & Labour applying a coat of solar reflective aluminium paint @ 0.11 kg per sqm on APP membrane surfaces complete all as specified and as directed by the Engineer-in-charge.
Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish , complete all as specified and directed.
Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish, complete all as specified and directed.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 75 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
Supply and fixing joint less made of single extruded WPC (Wood Polymer Composite) solid decorative type moulded flush door shutter of size 30mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
Supply and fixing joint less made of single extruded WPC (Wood Polymer Composite) glazed and skelton door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: wire mesh ,stainless steel butt hinges shall be paid separately
Material & Labour for Cutting holes depth not exceeding half brick wall in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed
Material & Labour for PCC 1:3:6, type C–0 (12.50mm graded crushed stone aggregate) as in bed blocks for hold fast & filling of pressed steel frame, etc, including necesssary formwork complete all as specified and directed.
Supply and fixing for powder coated aluminium (minimum thickness of powder coating 50 micron) for frame and shutters of doors, windows (fixed, sliding, hanging) & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer–in–charge.
Supply and fixing anodised aluminium grill (anodized transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the window frame with C.P brass/ stainless steel screws @ 200 mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodized aluminium standard section around the opening, , complete, all as specified and as directed.
Material & Labour sheet glass 3.00mm thick tinted ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane, complete all as specified and directed by Engr-in- charge.
Supply and fixing 3mm thick frosted sheet glass ordinary type and glazing with aluminium beading, rubber packing or oil putty in square n exc 0.5 sqm each pane complete all as specified and directed.
Supply and fixing for galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples , complete all as specified and directed.
Supply and fixing of butt hinges 100mm long of mild steel, medium weight,, complete all as specified and directed.
Supply and fixing of 150 mm long, aluminium anodised, barrel tower bolts of extruded section , complete all as specified and directed.
Supply and fixing of 150 mm long aluminium handle, cast type, anodised , complete all as specified and directed.
Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter , complete, all as specified and as directed.
Supply and fixing floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm , complete, all as specified and as directed.
Supply and fixing mild steel 300 mm, ordinary rat tail rod pattern springs, including roller and roller plate including fixing to steel frame complete all as specified and directed.
Supply and fixing stainless steel tubing of 25 mm dia chromium plated min 1.0 mm wall thickness as in curtain rod complete incl Supply and fixing 02 Nos stainless steel brackets/finials fancy type, stops fixed with ss screws etc complete fixed as in repair complete all as specified and as directed by the Engineer–in–Charge. Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the engineer - in-charge
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the engineer - in-charge
Cutting chases to brick wall built in cement mortar, pinning in making good to facing where required and pointing in CM 1:3 to edges of landing, steps, cills ,sunsheds, shelves, lintel etc and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the engineer - in- charge
Supply and fixing for GI tubing 15mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Supply and fixing for GI tubing 20mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Supply and fixing as in repair, water storage tank, 500 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm dia high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore and including 20mm bore tank nipple & one 20mm GI union at outlet and including disconnecting & dismantling of water tanks and removing from site all as specified in SSR Part–I complete, all as specified and as directed.
Supply and fixing 20 mm bore Gun–metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe as in repair , complete, all as specified and as directed.
Supply and fixing 15 mm bore Gun–metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe as in repair , complete, all as specified and as directed.
Supply and fixing bib taps 15mm bore fancy type brass chromium plated with long body, wall flanges and capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair , complete, all as specified and as directed.
Supply and fixing fancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe as in repair , complete, all as specified and as directed.
Supply and fixing 15mm bore cast copper alloy chromium plated angular stop valves with capstan head, screwed down, high pressure screwed both ends for iron pipe or for unions as in repair , complete, all as specified and as directed.
Supply and fixing in repair consealed stop cock chromium plated fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fixing PVC connections 15 mm size with PTMT nuts of length 600 mm as in repair , complete, all as specified and as directed.
Supply and fixing vitreous china wash hand basin white, flat back of size 550mm x400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc as in repair , complete, all as specified and as directed.
Supply and fixing vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe as in repair , complete, all as specified and as directed.
Supply and fixing as in repair vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, CP coupling ,PVC waste pipe, providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair 10 litre capacity PVC valveless, syphonic action type flushing cistern low level, white, with inlet ball valve, float and handle including bracket and PVC 32mm dia flush pipe fixed with WC complete all as specified and directed.
Supply and fixing in repair pvc grating 100mm dia with or without waste hole complete all as specified and directed.
Supply and fixing in repair 15mm bore shower rose chromium plated 125mm dia alongwith 15mm bore shower arm 195 mm long with bend of 45 degree complete all as specified and directed.
Supply and fixing in repair brass chromium plated soap dish holder and fixed with brass screws to wall complete all as specified and directed.
Supply and fixing as in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer–in–Charge.
Supply and fixing in repair stainless steel towel ring round between flanges including fixing with brass screws complete all as specified.
Material & Labour for factory made precast RCC manhole covers with frame (type A–1, 1:2:4, using 20 mm graded stone aggregates), of different sizes with plain faces, including 3mm thick mild steel flat sheet all around , mild steel handle 02 nos and incl reinforcement, set in cement mortar 1:4 including demolition of existing manhole cover complete all as specified and as directed.
Taking down of PVC /cast iron/RCC drain pipes /rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan–necks, etc., including cleaning or refixing or removal to store, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
Supply and fixing 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed in wall including all fittings (bend,branch piece,tee & coupler etc ) complete all as specified and directed.
Supply and fixing 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid trenches, floor including all fittings (bend,branch piece,tee & coupler etc ) complete all as specified and directed.
Supply and fixing in repair 110 mm bore PVC cowls 110mm bore complete all as specified and directed
Supply and fixing 75mm bore PVC (SWR) pipes single socketed incl all necessary fitting bend, tee, single Y etc. in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer–in–Charge
Supply and fixing 75mm bore PVC (SWR) pipes single socketed incl all necessary fitting bend, tee, single Y etc. in any length with rubber ring joints, laid in floor /trenches complete all as specified and as directed by the Engineer–in–Charge
Supply and fixing in repair 75 mm PVC(SWR) floor trap with grating incl jointing to waste pipe incl fixed in cement concrete type B–1 (1:2:4) complete all as specified and as directed.
Supply and fixing in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and directed.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation, for laying of cables, pipe etc. or for shafts, wells, manholes etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and wall ramming in layer n exc not exc 25 cm, any kind of soil , complete all as specified and directed.
Removing surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point , complete all as specified and directed.
Supply and fixing Reinforced concrete pipes, class NP2, 150 mm dia bore laid and jointed complete with collars complete all as specified and as directed by the Engineer-in-Charge
Material & Labour PCC 1:4:8, type D–2 (using 40mm graded crushed stone aggregates)as foundation filling & mass concrete etc complete all as specified and directed.
Schedule 'A' Part-II (E/M itmes) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc., ,complete all as specified and as directed.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description all as per serial item No.91 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.91 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.91 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Point wiring shall be done in a manner that not more than 02 socket point executed in one circuit. (ii) Each socket point will be measured and paid as per point.
Description all as per srl item No 91 here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Point wiring shall be done in a manner that not more than 01 socket point executed in one circuit. (ii) Each socket point will be measured and paid as per point.
Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular socket outlet multipin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular socket outlet multipin combined, (6pin), 16 Amps, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair electronic Fan regulator, modular 100 watts, 1 module, 230 volts, 50 Hz, AC supply suitable for ceiling fan any type/make/sweep, complete, all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair LED batten fitting 20 watt, 4 feet, polycarbonate housing with electronic driver cool/warm type, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LBLN-20-C-SQ of make Orient or equivalent in make given in Appx 'B'.
Supply and fixing in repair LED batten fitting 10 watt, 2 feet, polycarbonate housing with electronic driver cool/warm type, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LBLN-10-C-SQ of make Orient or equivalent in make given in Appx 'B'.
Supply and fixing in repair, LED Bldg Security Light Fittings of capacity 40-45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver and making electrical connection, complete all as specified and as directed by the Engineer-in-Charge. Cat part No.LSFS-45-CF-PC of make Orient or HLSLD-14-40-CWDL-R01 of make Halonix or equivalent in make given in Appx 'B'.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCBs 20 Amps, 10 KA 'B' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811955 of make Indo Asian or equivalent in make given in Appx 'B'.
Supply and fix sheet metal enclosure triple pole & neutral(TPN) 4 way IP-43 with MCB TPN 63 Amp, 16 KA, 415 volts, flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811840 of make Indo Asian or equivalent in make given in Appx 'B'.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811807 of make Indo Asian or equivalent in make given in Appx 'B'.
Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. Cat part No 811008 to 811015 of make Indoasian or equivalent make given in Appx 'B'.
Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.Cat part No 811035 of make Indoasian or equivalent make given in Appx 'B'.
Supply and laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing as in repair complete all as directed by Engineer-in-Charge and earth testing on completion.
Supply & Laying or fixing or passing through pipe in repair of cable XLPE insulated, armoured heavy duty electric cable with multistranded aluminium conductor 1100 volts grade 4 core of size 25 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for laying of cables and getting out in soft/ loose soil, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair light grade GI Tubing of 25 mm bore for cable protection and fixed with clamp to pole a on wall with clamp, nut, bolts, washer etc., complete all as specified and as directed by Engineer-in-Charge
Material and labour dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supply and laying well burnt brick class-B laid flat to cover the cable with width equal to the length of cable and abutting each other for protection of cable, complete all as specified and as directed by Engineer-in-Charge.
Note:- Amount of credit of Rs.1,05,883.00 for retrieved materials is mentioned in Schedule of Credit Page No. 123 & 124 of tender doCubic metre ents in pdf form which will be deducted offline while acceptance of tender.
stage.html
html • 0.04 MB
technical_835951.pdf
techsummary_835951.pdf
finance_835951.pdf
BOQ Comparative Chart
xlsx
finsummary_835951.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
BOQ_835951.xls
BOQ • 6.53 MB
Tenderdocument.pdf
Tender Documents • 1.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .