| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA | HARYANA | 133001 | ₹42.9 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹45.9 LRejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹45.9 L | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹51.5 LRejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹51.5 L | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹53.7 LRejected-Finance 303 GHS 88 SECTOR 20 PANCHKULA 134113 HARYANA | PANCHKULA | HARYANA | 134113 | ₹53.7 L | L4 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | Esha Engineers L1 | Raman Electric Trading Co L2 | M/S Sonu Traders L3 | R D Bansal L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking out / down faulty unserviceable 11KV HT UG cable from trenches/duct/ HT poles, nominal cross sectional area from 95 sqmm to 240 Sqmm, 3 core including disconnecting of cable and taking out PCC covers of any descriptions complete all as specified & directed.
Notes: (i) Earth work shall be measured & paid separately.
(ii) Serviceable cable covers will be kept aside for re-use. | 1,055 | RM | 20 ₹21,100 | 20 ₹21,100 | 10 ₹10,550 | 14 ₹14,770 |
| 2.00 | Supplying, laying, jointing, testing & commissioning HT 11 KV ( E) XLPE insulated cable aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 part-II (1985) with amendment, Size 3 core & cross sectional area 240 Sqmm, laid in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed. | 150 | RM | 1,680 ₹2.5 L | 2,000 ₹3 L | 2,000 ₹3 L | 1,660 ₹2.5 L |
| 3.00 | Supplying, laying, jointing, testing & commissioning HT 11 KV ( E) XLPE insulated cable aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 part-II (1985) with amendment, Size 3 core & cross sectional area 185 Sqmm, laid in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed. | 160 | RM | 1,380 ₹2.2 L | 1,625 ₹2.6 L | 1,700 ₹2.7 L | 1,345 ₹2.2 L |
| 4.00 | Supplying, laying, jointing, testing & commissioning HT 11 KV ( E) XLPE insulated cable aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 part-II (1985) with amendment, Size 3 core & cross sectional area 120 Sqmm, laid in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed. | 325 | RM | 1,120 ₹3.6 L | 1,250 ₹4.1 L | 1,200 ₹3.9 L | 1,039 ₹3.4 L |
| 5.00 | Supplying, laying, jointing, testing & commissioning HT 11 KV ( E) XLPE insulated cable aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 part-II (1985) with amendment, Size 3 core & cross sectional area 95 Sqmm, laid in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed. | 420 | RM | 880 ₹3.7 L | 1,050 ₹4.4 L | 1,050 ₹4.4 L | 922 ₹3.9 L |
| 6.00 | Excavation in trenches, not exceeding 1.5mtr wide & not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose type of soil complete all as specified & directed. | 342 | Cum | 80 ₹27,360 | 90 ₹30,780 | 90 ₹30,780 | 85 ₹29,070 |
| 7.00 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose type of soil complete all as specified & directed. | 205 | Cum | 20 ₹4,100 | 30 ₹6,150 | 20 ₹4,100 | 10 ₹2,050 |
| 8.00 | Removal of surplus excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed. | 137 | Cum | 20 ₹2,740 | 30 ₹4,110 | 20 ₹2,740 | 20 ₹2,740 |
| 9.00 | M&L sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified & directed. | 68 | Cum | 240 ₹16,320 | 200 ₹13,600 | 300 ₹20,400 | 325 ₹22,100 |
| 10.00 | Supply & laying un-reinforced precast concrete cable cover , Class HVP type-1 with flat, size 300mm x 180mm x 40mm, laid flat for protection of cable, adjacent to each other, perpendicular to central axis of cable complete all as specified & directed. | 4,339 | Each | 15 ₹65,085 | 17 ₹73,763 | 20 ₹86,780 | 16 ₹69,424 |
Updated dates
Tender Value
₹66 L
EMD Value
₹1.2 L
Closing Date
21 Jan 2026, 6:00 pmClosed
CWE (AF) Ambala
HQ CWE (AF) Ambala
CWE/AF AMB/AMB-46/2025-26 REPAIR MAINT OF TRANSFORMERS HT EQPMT AND CONNECTED ITEMS IN 66 KV AND 11 KV SUB STATION AREA AT AF STN AMBALA UNDER GE AF AMBALA
2025_MES_744779_1
CWE/AF AMB/AMB-46/2025-26
Open Tender
Civil Works
180 days
Ambala Cantt
For MES enlisted contractor Class C Category b ii and for un-enlisted contractor
refer NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) Ambala
₹1.2 L
Yes
25 Mar 2026
16 Dec 2025
23 Jan 2026
16 Dec 2025
21 Jan 2026
7 Jan 2026
16 Dec 2025 - 5 Jan 2026
Cutting/ Lopping of tree branches (girth not exceeding 15 cm) upto any height and any type of trees in route of / along the running HT OH conductor 11000 volts lines using suitable T&P and removal of cut branches from site to distance exceeding 250 mtr complete all as specified & directed. Note :- The length of one Span shall be approx 50 mtr. The tree branches after cutting, shall remain 2.00 mtr away from the outer/nearest conductor of OH lines.
Taking out / down faulty unserviceable 11KV HT UG cable from trenches/duct/ HT poles, nominal cross sectional area from 95 sqmm to 240 Sqmm, 3 core including disconnecting of cable and taking out PCC covers of any descriptions complete all as specified & directed. Notes: (i) Earth work shall be measured & paid separately. (ii) Serviceable cable covers will be kept aside for re-use.
harge-Class 3. (f) High current discharge-100 KAP. (g) Max residual voltage-165 KVP at 01 KAP
Excavation in trenches, not exceeding 1.5mtr wide & not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose type of soil complete all as specified & directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose type of soil complete all as specified & directed.
M&L silica gel in sealed bag of make/specifications as exists at site complete all as specified & directed.
M&L isolating contact assembly (set of 6 Nos.) suitable for VCB 11000 volts, 400/630/800 Amps rating, 13.1 KA including necessary connection & testing as per existing make and specification, complete all as specified & directed
Supplying, laying, jointing, testing & commissioning HT 11 KV ( E) XLPE insulated cable aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 part-II (1985) with amendment, Size 3 core & cross sectional area 240 Sqmm, laid in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed.
M&L winding of transformer any capacity at HT/LT side with super enamelled copper wire of gauge & weight as exists, varnishing & drying by vaccum impregnating, provinding insulating material, fixing the coil in the position in core assembly and making connection as per original pattern complete all as specified & directed.
M&L LT/HT side bushes of transformer of capacity 500 KVA to 800 KVA existing size, specification and make of equipment complete all as specified & directed.
Description all as per BOQ item No. 22 here-in-above but 250KVA & above capacity transformer.
S&F Drop out fuse 5 Amp to 20 Amp in existing air break switch / DO assembly of 11KV at different locations complete all as specified & directed.
Supply laying & testing of Control cable 4 sqmm 2 core copper conductor solid sheathed unarmoured complete all as specified & directed.
Description all as per BOQ item No. 28.00 here-in-above but for transformer of capacity 50KVA to 150KVA.
Dismantling & taking down of old unserviceable ACSR conductor any type including jumpers binding wire any section etc. including removal from site complete all as specified & directed.
M&L for servicing/ cleanng of C&R (Control and Relay) Panel and check the control wiring in control room of 66 KV yard including marshelling box 200 TB (MK 03 Nos) and all control panel of CT/PT/SF-06/Isolator /earth line switch etc. including testing of NGR resistance test and all type protection relays complete all as specified & directed Note : Any test equipment required to make functional /testing the equipment will be provided by the contractor without any extra cost to the department.
Supplying, laying, jointing, testing & commissioning HT 11 KV ( E) XLPE insulated cable aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 part-II (1985) with amendment, Size 3 core & cross sectional area 95 Sqmm, laid in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed.
Removal of surplus excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
Supply & laying un-reinforced precast concrete cable cover , Class HVP type-1 with flat, size 300mm x 180mm x 40mm, laid flat for protection of cable, adjacent to each other, perpendicular to central axis of cable complete all as specified & directed.
S&F in replacement Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified & directed.
S&F in replacement post insulator, 11000 volts grade for gang operated air breaker switch including necessary nuts, bolts & washers complete all as specified & directed.
S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed.
Each Job
S&F in replacement male contacts suitable for 400 amps rating vertical mounted gang operated air breaker switch 11000 volts grade including necessary nuts, bolts & washers complete all as specified & directed.
S&F in replacement female contacts suitable for 400 amps rating vertical mounted gang operated air breaker switch 11000 volts grade including necessary nuts, bolts & washers complete all as specified & directed.
Supply laying & testing of Control cable 2.5 sqmm 16 core copper conductor solid sheathed unarmoured complete all as specified & directed.
M&L in replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS clamps, bolts and nuts on pole, for HT of 25cm x 20cm size as per SSR Part-I complete all as specified & directed.
M&L cradles guard, hexagonal/rectangular, fabricated with galvanised steel wire 4.00 mm dia including dismantling of old existing cradle guard complete all as specified & directed.
M&L plain cement concrete (PCC) 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates as in foundations, filling and mass concrete etc. complete all as specified & directed.
M&L plain cement concrete (PCC) 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates as in coping to pole etc. including necessary formwork to exposed surface finished even & smooth complete all as specified & directed.
M&L cleaning and preparation of surfaces of HT/LT steel tubular poles(any size) with emery paper, filling the voids with suitable filler materials and applying two coats of aluminium paint over & including one coat of zinc oxide primer to poles, cross arms, brackets, hooks, junction box, stay clamps with and including making blue & orange(AF pattern) strip 30cm wide (5 Nos) upto 1.5 mtrs from PCC coping and marking the numbering on poles with synthetic enamel paint complete all as specified & directed.
Description all as per BOQ item No.106.00 here-in-before but 400 Amp current rating.
Dismantling/taking down/out old unservieable air break gang operated switch from two/four pole structure including supply & fixing Switch Air break gang operated, triple pole, for horizontal or vertical operation, mechanically operated, outdoor type, mounted on 12 insulators and steel frame with operating mechanism & operating rod of 25mm bore, heavy grade GI pipe from ground level with & including locking arrangement & minumum 02 Nos. eye hook, 200 Amps current rating 11000 volts working pressure including making electrical connections to make it functional after testing complete all as specified & directed.
M&L in replacement true vertical steel tubular, swaged welded pole conforming to IS-2713 part II , type 410 SP 55, 11 metre long complete with mild steel base plate of 6 mm thick of size 300 X 300 mm, finial taper plug, cap, bolts, nuts, washer and screws hole of required size and Nos. for fixing cross arms including painting externally with two coats of aluminium paint over & including one coat of zinc oxide primer for exposed surface and two coats of black bituminious paint for embeded portion in concrete as well as throughout internally including provision of blue & orange(AF pattern) colour strips with fluorescent paint upto 1.5 mtr height & nubmering of pole complete all as specified & directed. Note:- Excavation, earth work & PCC shall be measured and paid separately.
Disconnecting HT/LT cables & earthing connections, taking down & opening of defective transformer of capacity 500KVA to 800KVA, any make, from 2/4 pole structure / floor/platform mounted / CSS, for repair, opening up for inspection to asses the repairs required making joint inventories to carry out repairs, cleaning, greasing, removal of damaged parts, re-assembling after replacement of damaged parts of the transformer after repairs, making connections & reinstallation of transformer at site complete all as specified & directed.
Re-stretching of ACSR conductor (three lines) with and including binding of sagged loose conductors, of any type fixed on HT poles, at any locations including tightening the cross arms complete all as specified & directed. Note: Three lines of ACSR conductor in one span of 50 mtr length shall be measured as one unit for payment purpose.
S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed duly painted with two coats of aluminium paint over & including one coat of zinc oxide primer including dismantling of old unserviceable cross arm as existing complete all as specified & directed.
Dismantling & disconnecting electric connections of underground HT, XLPE cable,11 KV upto 240 Sqmm, from both sides and locating the fault in cable with fault locating machine in the entire length, removing moisture from cable, charging the HT cable with modern fault detector equipment by expert Engineers including reconnecting & commissioning the cable to make it functional complete all as specified & directed. Note: The work will be executed after obtaining proper shutdown from main power house after liasoning with Engineer-in-charge.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for indoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified & directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for indoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified & directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for outdoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified & directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for outdoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified & directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for straight through heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified & directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for straight through heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified & directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for straight through heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm to 300 Sqmm complete all as specified & directed.
Supply and fixing of Dew Guard (Moisture absorber) of size 100 x 150 x 2 mm thick shall be made of synthetic rubber and a super absorbent polymer and covered by a non woven fabric, absorbency of 0.8g (H2O)/1g (Product) @ 25 degree centigrade and 95% RH or higher works between a large temperature range of 30 to 90 degree centigrade, halogen and silicon free, HT panel of 11 KV substations complete all as specified and directed. Make : Hensel, Model No.HDG 100 or equavalent of ABB/Seimens
M&L in replacement jumpers of squirrel ACSR conductor 2 mtr long inlcuding stranded PG clamps in design of two Aluminium alloy with two or more galvanized steel bolts fixed at one end, the jumpers should be wrapped with PVC sleeves 15mm dia in different colour complete all as specified & directed.
S&F in replacement 75mm bore HDPE pipes PN-10, ISI marked, alongwith fittings, jointing with jointing materials for cable protection, laid in trenches/floors or fixed to poles/wall with sutable size of MS clamp, complete all as specified & directed.
S&F in replacement male contacts suitable for 200 amps rating vertical mounted gang operated air breaker switch 11000 volts grade including necessary nuts, bolts & washers complete all as specified & directed.
S&F in replacement female contacts suitable for 200 amps rating vertical mounted gang operated air breaker switch 11000 volts grade including necessary nuts, bolts & washers complete all as specified & directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for outdoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm to 300 Sqmm complete all as specified & directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender46.pdf
Tender Documents • 0.78 MB
BOQ_833953.xls
BOQ • 4.52 MB
Download all tender documents and submit your bid