Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.3 LAccepted-AOC 31 A K ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹12.7 L+₹4.4 L (52.9%)Rejected-AOC JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | 2 | Rejected-AOC L2 | |
| 3 | 3₹16.4 L+₹8.1 L (97.7%)Rejected-AOC 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | 3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | RS COOLING APPLIANCES | R.P.ELECTRONICS | STANDARD ELECTRONICS |
|---|---|---|---|---|---|---|
| 1.00AC installation | ||||||
| 1.01 | Supply Installation Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Compressor(s) for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with Non-CFC Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The outdoor units cooling Capacity control shall be 15% -100 % .The unit shall deliver the rated capacity at Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 380V-440V, 3 Phase, 50Hz AC power supply in/c all necessary related civil works for commissioning of the machine as per direction of the Engineer-in-charge.(Capacity 6HP cool only top Discharge) | 2 | Nos | 3,30,000 ₹4,22,400 | 2,40,000 ₹3,07,200 | 2,41,762.7 ₹2,85,279.99 Lowest |
| 1.02 | Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre- filter, fan section with low noise fan/dynamically balanced blower multispeed motor, coil section with Copper coil, electronic expansion valve outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V+ 10%, 50Hz AC supply ( 01TR). | 6 | Nos | 2,22,000 ₹2,84,160 | 2,04,000 ₹2,61,120 Lowest | 2,28,813.6 ₹2,70,000.05 |
| 1.03 | Supply of Refrigerant R410A for additional refrigerant gas. | 15 | Nos | 18,000 ₹21,240 | 18,000 ₹21,240 | 12,711.75 ₹14,999.87 Lowest |
| 1.04 | Installation of In-door unit (6Nos) , Out-door unit (2Nos) complete in all respect as per direction of the Engineer-in-charge . | 1 | Nos | 45,000 ₹53,100 | 25,000 ₹29,500 Lowest | 25,423.72 ₹29,999.99 |
| 1.05 | Providing and fixing of suitable size of control cable required for IDU to ODU connection complete in all respect & as required. Size of cable as per Manufacturer recommendation. | 90 | Nos | 17,550 ₹20,709 | 18,000 ₹21,240 | 6,102 ₹7,200.36 Lowest |
| 1.06 | Providing and fixing of Power cable of 3 Core x 1.5 sqm. Shielded cable in Heavy duty PVC. Complete in all respect & as required. | 50 | Nos | 16,250 ₹19,175 | 5,000 ₹5,900 | 1,271.5 ₹1,500.37 Lowest |
| 1.07 | Providing and fixing of Power cable of 4 Core x 6 samm. Shielded cable in Heavy duty PVC. Complete in all respect & as required as per direction of the Engineer-in-charge. | 65 | Nos | 30,550 ₹36,049 | 19,500 ₹23,010 | 16,524.95 ₹19,499.44 Lowest |
| 1.08 | Supply of Refrigerant Copper Piping for VRF system 28.5 mm dia (OD) (Hard drawn) with 19mm thick insulation | 40 | Nos | 40 ₹47.2 | 64,000 ₹75,520 | 34 ₹40.12 Lowest |
| 1.09 | 25.4 mm mm dia (OD) Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation | 10 | Nos | 10 ₹11.8 | 10,000 ₹11,800 | 8.5 ₹10.03 Lowest |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
9 Jun 2025, 5:00 pmClosed
MDS, TSCST
Vigyan Bhawan First Floor
Supply, Installation, Testing and Commissioning of VRF/ VRV Air Conditioning System at Science City Agartala
2025_SEB_61653_1
I/698616/2025 dt. 17.05.2025
Open Tender
Electrical Work/ Equipment
Supply
45 days
Science City Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹15,000
31 Dec 2025
19 May 2025
9 Jun 2025
19 May 2025
9 Jun 2025
21 May 2025
AC installation
Supply Installation Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Compressor(s) for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with Non-CFC Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The outdoor units cooling Capacity control shall be 15% -100 % .The unit shall deliver the rated capacity at Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 380V-440V, 3 Phase, 50Hz AC power supply in/c all necessary related civil works for commissioning of the machine as per direction of the Engineer-in-charge.(Capacity 6HP cool only top Discharge)
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre- filter, fan section with low noise fan/dynamically balanced blower multispeed motor, coil section with Copper coil, electronic expansion valve outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V+ 10%, 50Hz AC supply ( 01TR).
Supply of Refrigerant R410A for additional refrigerant gas.
Installation of In-door unit (6Nos) , Out-door unit (2Nos) complete in all respect as per direction of the Engineer-in-charge .
Providing and fixing of suitable size of control cable required for IDU to ODU connection complete in all respect & as required. Size of cable as per Manufacturer recommendation.
Providing and fixing of Power cable of 3 Core x 1.5 sqm. Shielded cable in Heavy duty PVC. Complete in all respect & as required.
Providing and fixing of Power cable of 4 Core x 6 samm. Shielded cable in Heavy duty PVC. Complete in all respect & as required as per direction of the Engineer-in-charge.
Supply of Refrigerant Copper Piping for VRF system 28.5 mm dia (OD) (Hard drawn) with 19mm thick insulation
25.4 mm mm dia (OD) Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
Supply of Refrigerant Copper Piping for VRF system 19.1 mm dia (OD) (Hard drawn) with 19mm thick insulation
Supply of Refrigerant Copper Piping for VRF system 15.86 mm dia (OD) (Hard drawn) with 19mm thick insulation.
Supply of Refrigerant Copper Piping for VRF system 12.7 mm dia (0D) (Hard drawn) with 19mm thick insulation.
Supply of Refrigerant Copper Piping for VRF system 9.5 mm dia (OD) (Hard drawn) with 19 mm thick insulation
Supply of Refrigerant Copper Piping for VRF system 6.4 mm dia (OD) (Hard drawn) with 19 mm thick insulation
Drain Piping for VRF system Providing & fixing of 25 mm dia UPVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness of closed cell nitrile rubber as required & as per specifications
Installation, testing and commissioning including accumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with copper fittings and silver soldered joints, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class O tubular Insulation/with Class- closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
Supply and Installation of Out-door unit base as per direction of the Engineer-in-charge.
Supplying and laying of Following sizes XLPE insulated PVC Sheathed Copper conductor un- armoured Cable including necessary connection etc as required i)3 core 4sq mm
i i) 4 core 10 sq mm
Supplying and Installation of 10 KA breaking capacity , B/C curve MCB of following rating in the existing MCB DB including connection as required . i) 6 to 32 amps TP MCB
Supplying and installation of RCCB (sensitivity 30 mA to 300 mA) of following rating in the existing MCB DB including connection etc as required. i) 63 amps FP RCCB
ii) 63 amps DP RCCB
Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts /MCB/ isolator/RCCB/(SP/SPN/DP/TP/TPN/FT) complete with necessary bus bar , neutral link,din rail,earth bar etc i/c connection as required i) 4 way SPN DB MCB DB (Single door) i) 4 way SPN DB MCB DB (Single door)
Supplying and fixing of the following sizes PVC conduit ( medium gauge) on surface with all accessories etc. as required i) 25mm dia
ii) 32mm dia
Supplying and fixing of the following electrical accessories including necessary connection etc. as required. i) 5/6 amps piano type switch
ii) . 3pin5/6 amps piano type socket.
Supplying and fixing of the following sizes PVC switch Board with cover etc. as required i) 75mmx75mm(3''x3'')
ii) 102mmx102mm(4''x4'')
iii) 102mmx178mm(4''x7'')
iv)152mmx203mm(6''x8'')
v) 203mx254mm(8''x10'')
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .