Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.6 LAccepted-AOC | 1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | UNION ELECTRIC ENGINEERING WORKS L1 |
|---|---|---|---|---|
| 1.00Panel board erection, pump house rewiring, old pump dismantling | ||||
| 1.00 | OD108818/2024-2025:ENERGY METER CUBICLE : Fabrication, Supply,
Installation, testing & Commissioning of enery Meter
cubicle made out of 16 SWG CRCA sheet consisting
of the following. (to be fixed outside the building).
Separate chamber for energy meter (with fixing plate,
view glass and holes with rubber gromets), Separate
Lockable CT chamber big enough to accommodate 3
nos. CTs comfortably, (Minimum 65cm width for
housing CT) Chamber for Cutouts & switchgear etc.
and consisting of the following.
3 Nos.500A Open Type cutout fuse with bakelite
base and with 400A HRC fuses. 4 Runs 95 Sq.mm PVC insulated copper wire for
giving internal connections between C/O fuses, 25x3 mm Tinned copper earth bench with
black sleeve mounted on FRP insulators for Neutral
etc with copper Lugs and SS Nuts&Bolts.
Spreader and SS Nuts & Bolts, Rubber gromets for
metal crossings of wires, door knobs with lock nuts
etc.
Mark Cut out fuse
ratings, cable size, consumer No.etc. neatly using good quality stickers /Paint.
Complete with all interconnections and powder
coated painting. | 1 | no | 28,369.63 ₹28,369.63 Lowest |
| 1.00 | OD108860/2024-2025:Supplying and fixing of 1no 400A TPN MCCB, 2nos of 250A TP MCCB, 2nos 200A TP MCCB, 2nos 150A TP MCCB. NOTE: THIS COMPLETE ITEM SHALL BE SUPPLIED BY KWA approved makes. | 1 | no | 86,243.69 ₹86,243.69 Lowest |
| 1.00 | OD108819/2024-2025:Design, Fabrication, Supplying and Fixing of floor mounted Panel with as per given specification and following switchgear ratings and Metering (Voltmeter, Ammeter, Multi function meter and Indication Lamps. The panel will be manufactured/ Fabricated in according with IS specifications using good quality 14 SWG CRCA sheets, dust and vermine proof Copper busbar of suitable size rated to the I/C switch gear heat srinkable colour code sleeves and busbar supports and assembly. Panel should be mounted on a suitable ISMC frame.
Incoming:
1 No 400A MCCB, TPN, 36 Ka breaking capacity with all standard accessories & with Static releases, O/L Release, Shunt trip, Rotary Operating Handle.
Outgoings:
a) 2 Nos., 250A,TP, MCCB with accessories
b) 2 Nos., 200A,TP, MCCB with accessories
c) 2 Nos., 150A,TP, MCCB with accessories
d) 2Nos., of spare cabin for future
NOTE: Charges including labour charges and loading and unloading charges. | 1 | no | 90,782.84 ₹90,782.84 Lowest |
| 1.00 | OD113696/2024-2025:Supply, erection, testing and commissioning of Three phase, 415 Volt and 50 Hz electronic fully automatic starter suitable for 50 HP VT motor (suitable for slip ring type also if the motor is slip ring type motor) with over voltage and under voltage protection main conductor and by pass conductor as per IE rules, controller base with protection against Overload, Single Phasing, Phase reversal, phase imbalance, Conforms to lSllEC 60947-4-1 & IEC 60947-4-1 with features of Auto Restart, Vibration proof enclosure with lP54 protection class, ON/OFF, Voltage and Ampere indication etc. complete. | 2 | no | 76,661.56 ₹1,53,323.12 Lowest |
| 1.00 | OD108820/2024-2025:Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required 3.5 core 95sqmm | 15 | each | 1,138.18 ₹17,072.7 Lowest |
| 1.01 | OD108821/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for 3.5x95 sq mm (45 mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 2 | each | 559.96 ₹1,119.92 Lowest |
| 1.01 | OD108822/2024-2025:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and
providing masonry enclosure with cover plate having locking arrangement and
watering pipe etc. (withcharcoal/ coke and salt ) as required (USe only SS Nuts, Bolts and washers
along with copper sockets for giving
connections). | 1 | each | 6,281.07 ₹6,281.07 Lowest |
| 1.01 | OD108823/2024-2025:Supply and laying of No.10 SWG (rate for single run) size of bare copper conductor along with
above cables, for interconnections between panels,
DBs, change over switches etc. and also for
interconnections between earth pits. | 30 | metre | 107.95 ₹3,238.5 Lowest |
| 1.01 | OD108825/2024-2025:"Supplying and fixing following way prewired SP&N MCB distribution<br>board of steel sheet
for 240 volts on surface/ recess complete with<br>loose wire box, terminal connectors for all incoming and
outgoing<br>circuits, duly prewired with suitable size FRLS PVC insulated<br>copper conductor up to terminal
blocks, tinned copper bus bar,<br>neutral link, earth bar, din bar, detachable gland plate,<br>interconnections,
powder painted including earthing etc. as<br>required. (But without MCB/ RCCB/ Isolator) 2 + 10 way/ 12 way ,
Double door" | 1 | 1 nos | 3,302.76 ₹3,302.76 Lowest |
Tender Value
₹4.7 L
EMD Value
₹11,671
Closing Date
25 Aug 2025, 2:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer, P.H. Sub Division,KWA, Kottarakkara
State plan 2025_26_ Energy Efficiency Improvement, Optimisation of Electro mechanical Items_ BAWSS to Kundara and adjoining panchayathu_Rewiring of pump house and installation of new electrical panel boards at Ezhukone sump_General Civil Work
2025_KWA_776608_2
WRD/KWA-CE(SR)/TR/20930/2025
Open Tender
Civil Works - Water Works
Item Rate
30 days
Kundara
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,030
₹11,671
29 Nov 2025
14 Aug 2025
27 Aug 2025
14 Aug 2025
25 Aug 2025
14 Aug 2025
Amount
Panel board erection, pump house rewiring, old pump dismantling
OD108818/2024-2025:ENERGY METER CUBICLE : Fabrication, Supply, Installation, testing & Commissioning of enery Meter cubicle made out of 16 SWG CRCA sheet consisting of the following. (to be fixed outside the building). Separate chamber for energy meter (with fixing plate, view glass and holes with rubber gromets), Separate Lockable CT chamber big enough to accommodate 3 nos. CTs comfortably, (Minimum 65cm width for housing CT) Chamber for Cutouts & switchgear etc. and consisting of the following. 3 Nos.500A Open Type cutout fuse with bakelite base and with 400A HRC fuses. 4 Runs 95 Sq.mm PVC insulated copper wire for giving internal connections between C/O fuses, 25x3 mm Tinned copper earth bench with black sleeve mounted on FRP insulators for Neutral etc with copper Lugs and SS Nuts&Bolts. Spreader and SS Nuts & Bolts, Rubber gromets for metal crossings of wires, door knobs with lock nuts etc. Mark Cut out fuse ratings, cable size, consumer No.etc. neatly using good quality stickers /Paint. Complete with all interconnections and powder coated painting.
OD108860/2024-2025:Supplying and fixing of 1no 400A TPN MCCB, 2nos of 250A TP MCCB, 2nos 200A TP MCCB, 2nos 150A TP MCCB. NOTE: THIS COMPLETE ITEM SHALL BE SUPPLIED BY KWA approved makes.
OD108819/2024-2025:Design, Fabrication, Supplying and Fixing of floor mounted Panel with as per given specification and following switchgear ratings and Metering (Voltmeter, Ammeter, Multi function meter and Indication Lamps. The panel will be manufactured/ Fabricated in according with IS specifications using good quality 14 SWG CRCA sheets, dust and vermine proof Copper busbar of suitable size rated to the I/C switch gear heat srinkable colour code sleeves and busbar supports and assembly. Panel should be mounted on a suitable ISMC frame. Incoming: 1 No 400A MCCB, TPN, 36 Ka breaking capacity with all standard accessories & with Static releases, O/L Release, Shunt trip, Rotary Operating Handle. Outgoings: a) 2 Nos., 250A,TP, MCCB with accessories b) 2 Nos., 200A,TP, MCCB with accessories c) 2 Nos., 150A,TP, MCCB with accessories d) 2Nos., of spare cabin for future NOTE: Charges including labour charges and loading and unloading charges.
OD113696/2024-2025:Supply, erection, testing and commissioning of Three phase, 415 Volt and 50 Hz electronic fully automatic starter suitable for 50 HP VT motor (suitable for slip ring type also if the motor is slip ring type motor) with over voltage and under voltage protection main conductor and by pass conductor as per IE rules, controller base with protection against Overload, Single Phasing, Phase reversal, phase imbalance, Conforms to lSllEC 60947-4-1 & IEC 60947-4-1 with features of Auto Restart, Vibration proof enclosure with lP54 protection class, ON/OFF, Voltage and Ampere indication etc. complete.
OD108820/2024-2025:Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required 3.5 core 95sqmm
OD108821/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for 3.5x95 sq mm (45 mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
OD108822/2024-2025:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (withcharcoal/ coke and salt ) as required (USe only SS Nuts, Bolts and washers along with copper sockets for giving connections).
OD108823/2024-2025:Supply and laying of No.10 SWG (rate for single run) size of bare copper conductor along with above cables, for interconnections between panels, DBs, change over switches etc. and also for interconnections between earth pits.
OD108825/2024-2025:"Supplying and fixing following way prewired SP&N MCB distribution<br>board of steel sheet for 240 volts on surface/ recess complete with<br>loose wire box, terminal connectors for all incoming and outgoing<br>circuits, duly prewired with suitable size FRLS PVC insulated<br>copper conductor up to terminal blocks, tinned copper bus bar,<br>neutral link, earth bar, din bar, detachable gland plate,<br>interconnections, powder painted including earthing etc. as<br>required. (But without MCB/ RCCB/ Isolator) 2 + 10 way/ 12 way , Double door"
OD108826/2024-2025:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
OD108827/2024-2025:"Supplying and fixing63 amps rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD108828/2024-2025:Supplying and fixing 63 amps rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD108829/2024-2025:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required....- Single pole
OD108830/2024-2025:"Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). <br>Single Control light point with 6A, plate ceiling rose - Medium Point "
OD108831/2024-2025:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator - Medium Point.
OD108832/2024-2025:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). <br>Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points. "
OD109022/2024-2025:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 2.5 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 16A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Combined plug point with 16 A, 5 pin plug socket controlled by 16 A switch in the same switch board as that of light points.
OD108833/2024-2025:Supplying and fixing 150 mm X 75 mm X 60 mm metal box on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
OD108834/2024-2025:Supplying and fixing 180 mm X 100 mm X 60 mm metal box on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
OD108835/2024-2025:Supplying and fixing 200 mm X 150 mm X 60 mm metal box on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
OD108836/2024-2025:Supplying and fixing 200mm X 300mmx 60<br> metal box on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
OD108837/2024-2025:Supply and Fixing of KWA approved make outdoor type 40W LED light having Waterproof IP65 Full Polycarbonate Body
OD108838/2024-2025:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required <br>1200 mm 1X20W LED Lamp with box type fixture
OD108839/2024-2025:Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 90.4.5.2<br>1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C"
OD108840/2024-2025:Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
OD108841/2024-2025:"Supplying and fixing stepped type electronic fan regulator<br>on the existing modular plate switch box including connections but<br>excluding modular plate etc. as required."(DSR E & M 2016 1.25)
OD108842/2024-2025:Supplying and fixing brass batten/ angle holder including connection etc. as required.
OD108843/2024-2025:Supply and fixing 9 W LED bulb on wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
OD108844/2024-2025:Removing the existing damaged wiring with switch board in each room disposal of unserviceable surplus material and stacking of serviceable material as directed by officials
Bidder Name
UNION ELECTRIC ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1293469.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .