| 1 | L1₹11.2 LAccepted-AOC 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹11.4 L+₹21,705 (1.93%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance Being L-2 | |
| 3 | L3₹11.8 L+₹61,533 (5.48%)Rejected-Finance | L3 | Rejected-Finance Being L-3 | |
| 4 | Rejected-Technical 304 VELENTINE TOWER NEAR WAGHESHWARI TEMPLE FILM CITY ROAD MALAD E MUMBAI 400 097 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | - | Rejected-Technical Not Fulfilled NIT criteria |
Tender Value
Refer Docs
EMD Value
₹26,490
Closing Date
7 Jun 2021, 6:00 pmClosed
Sr.Manager (E-E),RHQ-WR
RHQ-WR,Airports Authority of India, Operational Building, Parsiwada Andheri East Mumbai 400072
As per BOQ
2021_AAI_77699_1
AAI/ENG/WR/SM/BHAV/NIT-1/21-22
Open Tender
Electrical Works
Item Rate
120 days
Bhavnagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,120
Yes
₹26,490
Yes
9 Sept 2021
25 May 2021
9 Jun 2021
26 May 2021
7 Jun 2021
26 May 2021
26 May 2021 - 2 Jun 2021
Amount
Supply of Bi-directional Inset Type High Intensity Runway Edge Light Fitting suitable for use with 2 x 105 W, 6.6 Amp Halogen Lamp, complete with all accessories etc. confirming to particulars specifications etc. and complete as required
Supply of 2 x 4 Sq.mm copper flexible secondary lead of following length made out of multistranded, annealed, PVC sheathed, unshielded, EPR insulated, antitermite & antirodent cable of 5 kv grade with moulded plug and receptacle as required as per particular specifications. a) 35 Mtr
Cutting of cable groove with kerf cutting machine for laying following number of 2 x 4 Sqmm secondary leads meant for inset type runway fitting on the concrete/ bituminous runway surface including kerfing, chiseling, cleaning and filling the groove with sealant compound after putting sealant primer after laying secondary lead including jute covering for protection etc. as required. a) 01 Run of Cable (For laying 35 Mtr Secondary Lead)
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable / pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Supply and fixing of 5 KV grade plug and receptacle of type -I class "B" connector and making field connections by crimping the plug and receptacle with the existing PVC insulated and PVC sheathed copper conductor cable including filling the gap with water sealant material, applying PVC HT insulation tape etc complete as required for the following size of cable. a) Single Core 16 Sq.mm
Installation, testing and commissioning of Bi-directional Inset Type High Intensity Runway Edge Light Fitting by making suitable hole with help of core cutting machine in the bitumen/pavement area of runway and fixing the fitting using quick setting sealant compound such as plasticised sulphur cement/dobefill resin compound including connection with secondary cable, positioning of isolation transformer in housing box, making good the runway to the original finish etc. as required.
Laying of 1 No. PVC insulated and PVC sheathed copper conductor cable of grade 5 KV and size 25 Sq.mm / 16 Sq.mm / 6 Sq.mm / Secondary lead in the existing RCC / Hume / Stoneware / GI pipe / HDPE / DWC Pipe etc. complete as required. (Cable Supplied by AAI)
Laying of 1 No PVC insulated and PVC sheathed copper conductor cable of grade 5 KV and size 25 Sq.mm/16 Sq.mm/ 6 Sq.mm direct in ground including excavation, sand cushioning, protective covering and refelling the trench etc. as required.
Earthing with GI earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe with charcoal or coke and salt as required.
Supply, Installation, Testing & Commissioning of Remote Control Panel Cum Display unit at Control tower fabricated from CRCA sheet of 2 mm thick with suitable height suitable for remote operation of CCR and comprise the following interconnection etc. with terminal block etc. as required as per specification etc. as required by Engineer-In-Charge. 1) Runway Circuit A & B 2) Taxiway Circuit A & B (Proposed Taxiway Fitting on Runway) 3) PAPI Circuit - 02 Nos 4) Simple Approach Light - 02 Nos 5) High Mast - 02 Nos (For Apron) 6) Wind Sock - 01 No 7) H-Indicator - 01 No 8) End Light Circuit A & B 9) Inset End Light Circuit A & B 10) Isolation Bay Circuit (Taxiway + High Mast) 11) Operational Signage's Board 12) Spares
Supply of control cable of size 2.5 Sq.mm 61 cores, 1.1KV annealed electrolytic copper conductor, armoured, PVC insulated, PVC sheathed as per IS : 1554-I & IS : 7098-I upto date.
Supply of control cable of size 1.5 Sq.mm 8 cores, 1.1KV annealed electrolytic copper conductor, armoured, PVC insulated, PVC sheathed as per IS : 1554-I & IS : 7098-I upto date.
Laying of 01 No. Control Cable of size 2.5 sq. mm., 61 cores, 1.1KV grade in the existing RCC/ HUME/ METAL pipe as required.
Laying of 01 No. Control Cable of size 2.5 sq. mm., 61 cores, 1.1KV grade in the existing masonry open duct as required.
Laying of 01 No. Control Cable of size 1.5 sq. mm., 8 cores, 1.1KV grade in the existing masonry open duct as required.
Supply installation tesing and comissioning of Termination box made of MS Sheet suitable for 61 core 2.5 sqmm 1.1 KV grade copper conductor with suitable size connector strip complete connection as required.
SITC of C.I. Transformer housing box water tight round type metal container of out side dia of 330 mm, height 450 mm made of 10 mm thick cast iron moulding all round except on top surface which is 15 mm thick etc. complete as required.
Supply and fixing of 6 mm thick M.S. powder coated cover plate to cover the CI transformer bousing box of 330 mm out side dia having suitable holes to fasten the cover with nut bolts arrangement etc. as required.
Supply of 4 x 25 Sq.mm sizes of 1.1 KV grade multicore aluminium conductor PVC insulated / XLPE insulated and PVC sheathed armoured cable as per IS-1554 (Part-I) 1988/IS-7098 (Part-I) 1985 respectively with upto date ammendments.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.(Upto 35 Sq.mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ GI / HDPE / DWC pipe as required.(Upto 35 Sq.mm)
Supplying and making end termination with brass compression gland and aluminium lugs for 4 x 25 Sq.mm (28mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for 4 x 25 Sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply of 7 mtrs. height GI OCTAGONAL continuously tapered galvanised street light pole with minimum 1000 mm long Three arm GI bracket (length and tilt angle of bracket shall be based on design) for installation of LED street light luminaire, suitable for wind velocity as per IS 875 (but not less than 50 m/sec.), fabricated out of 3 mm thick high tensile sheet steel in single piece construction having 130mm bottom, 70 mm top, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolts & anchor plate, rigid flange plate (200 x 200 x 12mm min.) welded with the base of pole for fixing on foundation bolts complete as required for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick bakelite sheet with 32 Amp heavy duty connector for loop in loop out cable terminations suitable for upto Three numbers 31/2 x 25 Sq.mm cables, including supply of 2A, 10kA, DP, C series, MCB for each fixture connections, earthing bolts for continuous earth connection complete, as required as per technical specifications.
Supply of 7 mtrs. height GI OCTAGONAL continuously tapered galvanised street light pole with minimum 1000 mm long four arm GI bracket (length and tilt angle of bracket shall be based on design) for installation of LED street light luminaire, suitable for wind velocity as per IS 875 (but not less than 50 m/sec.), fabricated out of 3 mm thick high tensile sheet steel in single piece construction having 130mm bottom, 70 mm top, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolts & anchor plate, rigid flange plate (200 x 200 x 12mm min.) welded with the base of pole for fixing on foundation bolts complete as required for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick bakelite sheet with 32 Amp heavy duty connector for loop in loop out cable terminations suitable for upto Three numbers 31/2 x 25 Sq.mm cables, including supply of 2A, 10kA, DP, C series, MCB for each fixture connections, earthing bolts for continuous earth connection complete, as required as per technical specifications.
Erection of 7 Mtr.high G.I. OCTAGONAL street light pole & bracket with all accessories by providing and making reinforced M 20 cement concrete foundation including excavation and refilling including positioning of template & foundation bolts (supplied with pole to match with pole base plate) & providing and fixing of DWC HDPE pipe of size 40 mm dia (2 pieces of min. 0.75 m length) in the foundation for loop-in-loop-out of the cable to the pole complete as required and as specified.
Supply of Electromechanical Time Switches. (Make : Hager, Model No. EH711 or equivalent)
Supply of 70 Watt LED type Road/ Street light with minimum protection level IP 66, pressure die cast housing with epoxy powder coated prismatic poly carbonate cover with individual LED lenses and complete assembly with LED, driver and accessories pre-wired up to terminal block i/c suitable mounting accessories etc. as required. [ Make : Wipro, Model No. LR02-781-XXX-57-G2 or equivalent as approved by EIC ]
Installation, Testing and Commissioning of LED street light fitting with all accessories on existing 7 Mtr high G.I. OCTAGONAL street light pole including supplying and drawing of 3C x 2.5 Sq.mm. FRLSH PVC insulated PVC sheathed flexible copper conductor cable from loop-in-loop-out box upto the individual streetlight fittings, connection etc. complete as required & as specified.
Supply of 1.0 Sq.mm size of copper conductor PVC insulated flexible, heat resistant flame retardent grade wires suitable for domestic and industrial purpose. Conferming to IS:694.
Supply of 1.5 Sq.mm size of copper conductor PVC insulated flexible, heat resistant flame retardent grade wires suitable for domestic and industrial purpose. Conferming to IS:694.
Supply of 2.5 Sq.mm size of copper conductor PVC insulated flexible, heat resistant flame retardent grade wires suitable for domestic and industrial purpose. Conferming to IS:694.
Manish Electricals
Taral Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .