ASSISTANT EXECUTIVE ENGINEER
OFFICE OF THE EXECUTIVE ENGINEER , LSGD DIVISION, PALAKKAD
Dist Pyt.Pkd 2020-21 Kozhiyodu Drinking Water Scheme in Kottayi Grama Panchayath (Project No 200/21
2020_LSGD_386017_1
183/E/20-21
Open Tender
Civil Works - Water Works
Item Rate
180 days
LSGD DIVISION
PLEASE REFER TENDER DOCUMENTS
4 documents required · 4 mandatory
₹2,000
Yes
online
₹25,000
Yes
20 Nov 2020
18 Sept 2020
8 Oct 2020
18 Sept 2020
5 Oct 2020
18 Sept 2020
90 days
Amount
od714633/2020_2021 : Site Investigation After Conduction Ground water Dept. Survey (GWA Orders)
od622715/2020_2021 : Drilling bore well 150 mm dia (6 inch) including all charges for conveying drilling<br>machine, hire charges and all labour charges etc complete
od622722/2020_2021 : Supplying and erecting 180 mm dia Casing pipe (6 kg/cm2) suitable for 150 mm bore ( 6<br>inch) including cost of pipe , conveyance erection charges etc complete
od622725/2020_2021 : Supplying and fitting end cap suitable for 180 mm dia casing pipe including all charges.
od681966/2020_2021 : Yield Testing Charges for Tube wells as per GWA Dept .Norms and Rates
od653243/2020_2021 : Supplying, erecting submersible pump (Three phase) to Bore well,using best quality,ISI motor and pump to suit the bore well,including cost of column pipe(UPVC),UG cable,Nylon rope,and all other fitting to including panel board etc and all charges for conveyance of materials,labour,and<br>taking connection from KSEB (charges for electrical connection paid separately)etc complete
od622733/2020_2021 : Supply and errection of Ferro cement pump house as per following specifications.a)<br>Foundation of size 1.50x1.50x0.60m ferro <br> cement square fitting by earth consolidation connecting using<br>cement concrete 1:4:8, b) Ferro cement ready made wall of size 1.50x1.50m (square type) having an average<br>thickness of 25mm and height 2.10m, c) Ferro cement ready made triangular type roof d) M.S. door with<br>necessary fittings 90x210cm size painting with synthetic enamel paint two coat after a priming coat includingf supplying a pad lock e) M.S. ventilator with grill of size 0.90xo.40m, painting with synthetic enamel paint two coat after a primary coat f) white washing two coat with cement proof paint two coat on inside and outside of pump house including roof.
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.37.1 : White washing with lime to give an even shade:New work (three or more coats)
50.18.9.7.1 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
51.18.12.5 : Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately) External work - 40 mm nominal dia
51.18.12.6 : Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately) External work - 50 mm nominal dia
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
SHAFEEQ N M
Bidder Name
SHAFEEQ N M
SUNIL V K
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_548227.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .