Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.3 Cr
EMD Value
₹2.7 L
Closing Date
23 Feb 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VICE CHAIRMAN GHAZIABAD DEVELOPMENT AUTHORITY
GDA OFFICE VIKAS PATH GHAZIABAD
Construction work of Pump House, Rising Main and Over Head Tank for 528 under construction building Pradhan Mantri Awas Yojna at Niwadi Modinagar.
2026_GDAUP_1107471_1
655/4/PA-T/2025-26 Dt. 16.01.2026 (S.No.-07)
Open Tender
Civil Works
Percentage
180 days
GHAZIABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,198
AS PER LINK PROVIDED IN TENDER DOCUMENT
₹2.7 L
23 Feb 2026
19 Jan 2026
25 Feb 2026
19 Jan 2026
23 Feb 2026
19 Jan 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of over head tank of capacity 200 K.L. storage capacity at 22m staging based on contractor's own design & drawing (bearing capacity of soil to be taken as 8 tones per sqm at 2m depth) completed with Im wide R.C.C staircase from ground level & steel ladder from balcony to top of dome. In balcony Im high G.l pipe railing over stair case, balcony and all around to dome made of three rows of 25 mm dia G.1. pipe medium class supported on.R.C.C posts or 50x50x6 mm size M.S. angle iron posts placed at suitable intervals i.e 1.25 mt. c/c or as directed by engineer in charge, supply & fixing of M.S. ladder from top of dome to inside of tank and supply & fixing 600x600 m M.S. manhole cover with locking arrangements as appd. by E/l and fixed at the top of dome and supply of all materials. Aluminum lighting conductor with extra arrangement of copper wire as per IS 3043 latest edition laid in electricity department or as per latest ISI specification. Further to provide mosquito proof ventilator of approved quality & fixing at the top of dome as per direction by E/1 further to provide water level; indicator with material and fixing them at desired level further to connect and hoist all C.I double flanged pipe specialy required for completel inlet, out let overflow & waste ort pipe arrangement with C.I double flanged pipe of the general specification providing jointing material such as rubber packing with nut bolts and fix them after embedding in the bottom of the tank from the designed depth below G.L. including fixing of sluice valve duck foot bend etc. inlet, outlet over flow and waste pipe arrangements with all fitting and to be painted with blank Japan paint. further to provide all material for supply of gate as per drawing with locking arrangements and painting with approved paint on complete structure with three coats of snowcem of approved quality. Construction of sluice valve chambers as per drawing. The rate should also include the testing of bearing capacity of soil and water tightness of tank. The bearing capacity of soil to be taken as 8.0 tonnes/sqm at 2m depth and consisting for specific load as per IS 1893-1894 to latest revised specification if any complete with all respect.Inlet pipe & out let pipe size as per hydraulic design wash out pipe 200 mm dia and over follow pipe 300mm dia double flanged C.I pipe as per jal Nigam specification including soil testing and design vetting and construction in all respect. structural design should follow the latest I'S code seismic provisions in the structural drawing & design. Also drawing should be checked/declared through IIT/goood agencies or any other institution as per approval of E/I. | 2,00,000 | per ltr. | 22.6 | ₹45,20,000 |
| 2 | Quote the rates for the following items
A For decreasing in bearing capacity of soil per 0.50 t/sqm in cal the design is submitted on raft foundation. | 0.5 | t/sqm | 2,00,000 | ₹1,00,000 |
| 3 | B. For increase bearing capacity of soil per 0.50 t/sqm in case the design is submitted on raft foundation.Mode of Payment .1. Excavation in foundation laying of lean concrete casting of foundation and columns upto GL (15%) 2. Completion of staging upto bottom of ring beam.(15%) 3. Casting of ring beam, tank base balcony (bottom dome)(25%)4. Casting of tank walls and top dome.(20%)5. Completion of stair case, fixing of ventilator Pipe lighting conductor etc.(15%)6. Finishing and testing of works to the specification as per direction of engineer-in-charge and testing for water tightness(10%). | 0.5 | t/sqm | 2,00,000 | ₹1,00,000 |
| 4 | Tubewell Driling of bore hole for Tubrwell construction by RC Rig machine including transporation errection dismentling of Rig and assoalted T&P complete in all required all material, labour etc. | 2 | nos | 16,13,000 | ₹32,26,000 |
| 5 | Rising main, Supply of the following sizes of D.I. pipes Class K-9 conforming to latest I.S. 8329/2000 complete in all respect F.O.R. destination including all taxes and insurance.125mm dia K-9,T.W. to OHT,Byepass Arrangement. | 355 | Rmt | 1,648 | ₹5,85,040 |
| 6 | Supply of D.I. S/S or flanged Specials conforming to I.S. 8329/2000 Suitable for above C.I.S/S pipe F.O.R destination including all Taxes and Insurance. | 355 | Rmt | 164.8 | ₹58,504 |
| 7 | Supply of the following sizes of C.I. Double flanged sluice valves as per I.S. 780/1969 class-1 working pressure 10kg/Sqcm F.O.R Destination including all taxes and Insurance.125mm dia. | 6 | nos | 47,575 | ₹2,85,450 |
| 8 | Excavation for pipe line work in soll mixed with moorum, kankar & shingle etc Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches.125mm dia k-9 | 292.84 | cum | 256.4 | ₹75,084.18 |
| 9 | Carting from the store (up to 8 Km.) The following sizes of D.I. double pipe k-9 and specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolls, rubber insertion, white lead etc. com- plate but excluding cost of trenching and cutting of pipes etc. For making of lengths bul including making joints.125mm dia k-9 | 355 | Rmt | 63.97 | ₹22,709.35 |
| 10 | Carting of D/F Sluice valves of following sizes to the site of works lowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc, complete excluding values and specials required but including the testing etc. complete.125mm dia k-9 | 6 | nos | 486.08 | ₹2,916.48 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
655_07.pdf
Tender Documents • 1.65 MB
BOQ_2043923.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .