| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹33.5 L+₹9.0 L (36.9%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹33.7 L+₹9.3 L (37.9%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹42.4 L+₹17.9 L (73.4%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹45.0 L+₹20.6 L (84.3%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹53 L
EMD Value
₹1.0 L
Closing Date
4 Oct 2021, 6:00 pmClosed
GE I DM
GE I DM NAVAL DOCKYARD, VISAKHAPATNAM 530014
REPAIR / RENEWAL OF DEFECTIVE INTERNAL ELECTRIC WIRING, FITTINGS AND FIXTURES AND CONNECTED WORKS OF BLDGS AT ZONE-1 AND 2 OF NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2021_MES_471884_1
SSGE/8607/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAVAL DOCKYARD, VISAKHAPATNAM
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE I DM
₹1.0 L
Yes
13 Dec 2021
31 Aug 2021
11 Oct 2021
31 Aug 2021
4 Oct 2021
27 Sept 2021
Amount
M & L for concealed/surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including FRLS PVC Conduit medium grade or PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including galvanised sunk metal terminal box fixed flush to wall with 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer for mounting of switch, regulators or bell push, ceiling rose/ holders etc incl necessary chase cutting for conduits and sinking boxes and making good to wallas,floors etc complete all as specified and directed dismantling taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and as directed. Note: (a) working height upto roof level of wksp buildings for item No-1 only (b) Cutting chases for conduit &making good to wall shall be measured and paid separately
All as per item No 1.00 above but for one 5 amps socket point independent complete all as specified and as directed.
All as per item No 1.00 above but for one 5 amps socket point in same board complete all as specified and as directed.
All as per item No 1.00 here-in-above but for one 15 amps socket point independent with 4.0 sqmm cable and 4.0 sqmm earth wire complete all as specified and as directed.
M & L for concealed/surface conduit wiring with 2 x 2.5 sqmm (Nominal area) single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable drawn through in and including FRLS PVC Conduit medium grade with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and as directed. Note:- (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. (b) working height upto roof level of wksp buildings for item No- 5 only (c) Cutting chases for conduit &making good to wall shall be measured and paid separately
All as per item No 5.00 above but cable of size 2 x 6.0 sqmm and earth wire 1x 4 sqmm
All as per item No 5.00 above but cable of size 4 x 10.0 sqmm and earth wire2x 6
M&L cutting chases,pinning in,making good to facings where required and pointing in cement cement mortar (1:3) to ends or edges of landings,stepscills, sunshades, sunshades, shelves, lintels etc. in brick walls and cutting chases for concealed water tubing or concealed conduit wiring etc. and making goo,cutting not exceeding 10 cm girth complete all as specified and as directed
S&F 5 Amp switch piano flush type single pole one way including dismentling taking down unserviceable one complete all as specified and as directed.
S&F bell push piano type one way 5Amp, 240 volt including dismentling taking down unserviceable one complete all as specified and as directed.
S&F switch socket combination 5 pin 5 amps, 230v including dismentling taking down unserviceable one complete all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 15 amps and 3 pin 5 amps, 230v including dismentling taking down unserviceable one complete all as specified and as directed.
S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, two module, 50 Hz including dismentling taking down unserviceable one complete all as specified and as directed.
S&F ceiling rose surface Bakelite three terminal including dismentling taking down unserviceable one complete all as specified and as directed.
S&F bell electric AC 240 volt, 50 HZ. including dismentling taking down unserviceable one complete all as specified and as directed.
S&F Hylam Sheet 3mm thick on existing concealled MS/CI rectangular or Square or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc including dismentling taking down unserviceable one complete all as specified and as directed.
S&F PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc including dismantling taking down unserviceable one complete all as specified and as directed. Make- Presto Teak/Press Fit/Plaza.
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve including dismentling taking down unserviceable one complete all as specified and as directed. Make- Schneider, Cat Part No- A9N1P06C - 32C or equivalent of Legrand/L&T/ABB.
S&F MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve including dismentling taking down unserviceable one complete all as specified and as directed. Make- Schneider, Cat Part No- A9N2P06C - 32C or equivalent of Legrand/L&T/ABB.
S&F MCB, three Pole, 40 to 63 amps, 415 Volts including dismentling taking down unserviceable one complete all as specified and as directed. Make- Schneider, Cat Part No- A9N3P40C - 63C or equivalent of Legrand/L&T/ABB.
S&F MCB, Four Pole, 40 to 63 amps, 415 Volts including dismentling taking down unserviceable one complete all as specified and as directed. Make- Schneider, Cat Part No- A9N4P40C - 63C or equivalent of Legrand/L&T/ABB.
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way including dismentling taking down unserviceable one all as specified and directed. MAKE- Schneider, Cat Part No- A9HSND08 or equivalent of Legrand/L&T/ABB.
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way including dismentling taking down unserviceable one complete all as specified and as directed. Make- Schneider, Cat Part No- A9HTND04 or equivalent of Legrand/L&T/ABB.
S&F Vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way including dismentling taking down unserviceable one complete all as specified and as directed. Make- Schneider, Cat Part No- A9HVD04L or equivalent of Legrand/L&T/ABB.
S&F Vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 8 way including dismentling taking down unserviceable one complete all as specified and as directed. Make- Schneider, Cat Part No- A9HVD08L or equivalent of Legrand/L&T/ABB.
S&F MCCB, 25KA, 4 pole, with thermal magnetic trip unit, rated current 125amps complete with spider link including dismentling taking down unserviceable one complete all as specified and as directed. (Suitable for MCCB incomer DB). Make: Schneider, cat No- LV430321 Compact NSX
S&F Metal plug and socket board with MCB SP 20 amp, 16 KA including dismentling taking down unserviceable one complete all as specified and as directed. Make- Schneider, Cat Part No- A9HMS220 or equivalent of Legrand/L&T/ABB.
S&F Metal Plug 20amps, 2 pole, 230V, make- Schneider, Cat No-AP10 or equivalent of Legrand/L&T/ABB.
S&F LED tube light fitting with LED tube, 2'long, 10 watt, CDL, 230 Volts , complete with all accessories internally pre wired including dismantling taking down unserviceable FTL/CFL fiitings complete all as specified and as directed. Make-CG, Cat Part No-LDL-10-CDL (Trimline) or equivalemt in Havells/ Philips/ Bajaj
Fixing only LED Tube light baten, 18/20 watt, 230 Volts, 4 feet long , complete with all accssories internally pre wired including dismantling taking down unserviceable FTL/CFL fiitings complete all as specified and as directed. (LED fitting will be issued under Sch B free for fixing)
Fixing only Square shaped recess mounted LED slim panel down lighter, 18/36 watt (1'X1' or 2`x2`), to POP/grid celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cableincl dismantling taking down unserviceable FTL/CFL fiitings any type complete all as specified and as directed. (LED fitting will be issued under Sch B free for fixing)
Fixing only Retro LED tube 20 watt to new/existing single/twin box type industrial fitting with addition / alteration to existing wiring for retro LED connection complete all as specified and as directed. (Retro LED tube will be issued under Sch B free for fixing)
Fixing only LED high bay light 150/200 watt at roof truss level of wksp buildings and other places incl dismantling taking down unserviceable one any type complete all as specified and as directed.(LED down lighter 150/200 watt will be issued under Sch B free for fixing)
Fixing only round block or double stiff pandent, industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 2x18/20 watt 4'long including dismantling taking down unserviceable FTL/CFL fiitings complete all as specified and as directed. Make-Bajaj, Cat Part No-BLRB-DB 218 or equivelent of Philips/CG/Havells
S&F LED recessed round or square polycarbonate housing down lighter with superior light output and integral driver , 12 watt, warm white, complete with fixing spring clip 2 nos, fixed flush to gypsum/grid ceiling including dismantling taking down unserviceable one any type . Make- CG, cat-LCDEP-12-WW , Quartz +R or LSDEP-12-WW, Quartz +Sor equivelent of Philips/ Bajaj/ Havells
S&F LED recessed round or square polycarbonate housing down lighter with superior light output and integral driver , 18 watt, warm white, complete with fixing spring clip 2 nos, fixed flush to gypsum/grid ceiling including dismantling taking down unserviceable one any type . Make- CG, cat-LCDEP-18-WW , Quartz +R or LSDEP-18-WW, Quartz +Sor equivelent of Philips/ Bajaj/ Havells
Fixing only LED recessed (4'x1') polycarbonate housing down lighter with superior light output and integral driver , 40 watt complete with fixing spring clip 4 nos, fixed flush to gypsum/grid ceiling including dismantling taking down unserviceable one any type . (LED fitting will be issued under Sch B free for fixing)
Fixing only LED flame proof batten suitable for twin T-8 tube of 20 watt, IP-65, 230V, CIMFR certified including necessary connection complete. Make-CG, Cat-EXTN2LT8-20 or equivelent of Sudhir/Shyam (LED retro Tube will be issued under Sch B free for fixing)
Fixing only LED building security light 90 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismantling taking down unserviceable fitting any type complete all as specified and as directed.. (LED fitting will be issued under Sch B free for fixing)
S&F LED engagement light Red & Green including dismantling taking down unserviceable one
M & L for Earthing complete with GI Pipe electrode, 40 mm bore, Medium grade, 2.5 mtr long buried directly and vertically in ground with top edge at ground level after making manual bore hole of size not less than 300 mm dia and 2.65 Mtr long near the specified bldg, connected with galvanised steel strip earthing lead of size 32mmx 6mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 80mm thick with handle for lifting made out of 8mm dia MS rod, wiremesh, charcoal and salt in alternate 150mm thick layers around CI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion after dismentling taking out unserviceable one..
Taking down and Refixing of loose conduit/casing capping cable wiring of size upto 10sqmm with clamps and required accessories complete all as specified and as directed.
Dismantling and Refixing Aluminium strip 25 x 3.15 mm laid in trench for earthing connection for various machines including dismantling taking down unserviceable strip complete all as specified and as directed.
Attending day to day complaint of no light, circuit fault, non-functional of fan / light / switch / socket / regulator, frequent tripping of MCBs by providing suitable electrician daily all as specified and directed by Engr-in-Charge. Note:- Work to be measured as unit specified contractor shall not complain for outsourcing work is to be carried out fill rectification any material as in this schedule shall be any material as in this schedule shall be measured as applicable. Required screws saddles, nuts, bolts insulation tapes shall be done by the contractor. Complaint shall be collected from online complaint cell and to rectified within 2 hours else recovery shall be made double to quoted rate.
S R CONSTRUCTIONS
aswitha engineering works
DELTA CONSTRUCTIONS
MEGHANA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .