Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAccepted-AOC CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | L1 | Accepted-AOC AOC | |
| 2 | L2₹46.2 L+₹1.4 L (3.23%)Rejected-Finance KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹47.6 L+₹2.8 L (6.25%)Rejected-Finance PSRA 146 A PULIMOOTTIL ROAD PADAMUGAL INDRA JUNCTION KAKKANAD PO KOCHI 682030 | KOCHI | ERNAKULAM | KERALA | 682030 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹53.1 L+₹8.3 L (18.5%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Feb 2022, 6:00 pmClosed
GE(I)(CG)KOCHI
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
PROVISION OF GROUND SUPPORT EQUIPMENT GSE SHED FOR DORNIER AT CGAE, NEDUMBASSERY, KOCHI
2022_MES_499897_1
GE/CG/8790
Open Tender
Civil Works
Item Rate
180 days
NEDUMBASSERY KOCHI
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I)(CG)KOCHI
₹80,000
Yes
26 Feb 2022
6 Jan 2022
12 Feb 2022
6 Jan 2022
5 Feb 2022
24 Jan 2022
6 Jan 2022 - 12 Jan 2022
Amount
SCHEDULE 'A' PART-I (B/R WORKS)
Material and Labour for drilling of holes of suitable dia, in to the PQC pavement and inserting 12 mm dia mild steel fixed fastner in to PQC pavement up to a clear depth 150 mm deep into PQC pavment complete all as specified and as directed. NOTE: Necessary nuts and bolts of fastner shall be measured and paid seperately under relevant items of schedule.
Material and Labour for drilling of holes of suitable dia, in to the PQC Pavement /Column/Beam of security wall for inserting 12 MM dia reinforcement bars to clear depth 100 mm deep into existing wall/ column/ beam and fixing the reinforcement bars into the holes using Lock Fix (Fosroc) chemical for firmly fixing the bars in to the holes complete all as per manufacturers instructions and as required at site. NOTE: Reinforcement shall be measured and paid seperately under relevant items of schedule.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for unreinforced complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation of drain complete all as specified and as directed.
Material and Labour for TMT(CRS/HCR) bar 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping, for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and Labour for TMT (CRS/HCR) bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
Material and labour for Precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces etc. including necessary form work, placed in position, set in CM 1:4 complete all specified and as directed.
Material and Labour for RCC M-30 design mix using 20mm graded stone aggregate as in foundation footing, raft, foundation beams base for columns etc complete all as specified and as directed.
Supply and fix Mild steel 1.25mm thick plain, black sheet in wall cladding, steel gates, walk ways and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
Supply and fix rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats conforming to Fe-410W(Gde E-250) quality B complete all as specified and as directed.
Supply and fixing Pre- painted galvalume aluminum zinc coated corrugated sheet of 0.50mm thickness having tensile strength of 550 Mpa with coating thickness fixed with GI self taping screws as in roof covering/cladding to wall, ridges, valley gutters fixed to frame work all as per manufacturers instructions all as specified and as directed.
Supply and fix for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with galvanised self tapping screws complete all as specified and directed.
Supply and fix Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and ncluding either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Grade E-290, Fe 410 W quality A complete all as specified and as directed.
Material and labour for preparation of new or previously untreated steel surface and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fix PVC half dia(semi circular) Rain water gutter 200 mm width fixted to purlins with MS Clamps of Flat iron complete all as specified and as directed. Note: MS clamps shall be measured and paid separately under relevant item.
Supply and fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Material and labour for precast cement concrete solid block masonry using Solid PCC block type C4 exceeding 10 cm width, built in cement mortar 1:4 all as specified and as directed.
Use and waste of formwork to sides of foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces, flat complete all as specified and as directed.
Supply and fix for mild plate(plain or chequerred), channel, square cut or notched(ordinary or counter sunk) forming holes with out any attachment conforming to Fe 410-W quality A(Gde-E-250) complete all as specified and directed.
Supply and fix PVC Rain water pipes of 200 mm dia vertically fixed to wall/ cladding using MS clamps, top end of the pipe shall be jointed with Rain water gutter complete all as specified and as directed. NOTE: MS clamps shall be measured and paid separately under relevant item.
Supply and fix PVC 200mm dia bend fixed in any direction and in any position complete all as specified and as directed by Engr in Charge.
Material and labour for rendering 15 mm on fair faces of brick or concrete surfaces in CM 1:4, finished even and fair without using extra cement complete all as specified and directed.
Material and Labour for preparation of plastered surfaces of wall and applying two coats of weather proof anti fungal exterior emulsion paint over a coat of primer complete all as specified and as directed. Make: Apex Ultima Protek of Asian/Exel of Nerolac/Weather Coat of Berger
SCHEDULE 'A' PART-II (E/M WORKS)
Material and labour for point wiring with PVC insulated unsheathed, multistranded FRLS copper conductor colour coded with cable 1.5 Sqmm size, 1100 volts grade, confirming to IS:694 drawn through and including stove enamelled steel conduit concealed including all accessories such as bend, Tee, junction boxes, elbows etc in new GI boxes made out of sheet 1.6 mm thick including one coat of synthetic enamel black paint and providing new 3mm thick plastic laminated sheet cover of approved colour fixed with brass screws and cup washers, including single core stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common eatrh and connected to earth dolly and earth terminal box for one light point or fan point controlled by one way switch 5/6 Amps complete all as specified and directed.
Material and labour for point wiring with PVC insulated unsheathed, multistranded FRLS copper conductor colour coded with cable 2.5 Sqmm size, 1100 volts grade, confirming to IS:694 drawn through and including stove enamelled steel conduit concealed including all accessories such as bend, Tee, junction boxes, elbows etc in new GI boxes made out of sheet 1.6 mm thick including one coat of synthetic enamel black paint and providing new 3mm thick plastic laminated sheet cover of approved colour fixed with brass screws and cup washers, including single core stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common eatrh and connected to earth dolly and earth terminal box for one power point controlled by one way switch 16 Amps complete all as specified and directed.
Supply and fix ceiling fan 1200mm sweep withdown rod, canopy etc, single phase 230 volt connecting with PVC insulated 23/.0076 flexible copper conductor complete all as specified and as directed. Make: ES-50 Premium 5 of Havells or equivalent in Usha/Crompton Greaves
Supply and Fix LED Flood light luminaries 50 watt 230 volt energy saving environmental friendly, long life exclusive of innovative die-cast aluminium flood light including suitable fixing arrangement as per requirement complete all as specified and as directed. Make: Havells Cat No. JETACOMPECTOFL50WLED757LTG or equivalent in Philips/Crompton Greaves.
Supply and fix Modular switch one way 6A, 1 Module complete all as specified and as directed.
Supply and Fix Modular switch socket combination 3 pin 16 Amp 230 volt complete all as specified and directed.
Supply and Fix Distribution board (DB) made out of sheet metal enclosure(CRCA sheet) dust and vermin proof, double door, SPN 8 way with 200 Amps rated copper bus bar double door protection,neutral bar,earth bar,single pole and neutral 240 volts, MCBs used as incommer, flush to wall complete all as apd and directed. Note: MCB shall be measured and paid separately.
Supply and Fix Distribution board (DB) made out of sheet metal enclosure(CRCA sheet) dust and vermin proof, double door, TPN 4 way with 200 Amps rated copper bus bar double door protection,neutral bar,earth bar,single pole and neutral 415 volts, MCBs used as incommer, flush to wall complete all as apd and directed. Note: MCB shall be measured and paid separately.
Supply and Fix MCB single pole, 6 to 32 Amp 240 volts C curve 10KA complete all as specified and as directed.
Supply and Fix MCB TPN, 32 Amp 415 volts C curve 10KA complete all as specified and as directed.
Supply and Fix MCB SPN, 32 Amp 240 volts C curve 10KA complete all as specified and as directed.
Supply, laying or passing through pipe LT, XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 35 Sqmm 3.5 corefixed on wall/laid in trenches including connecting/testing complete all as specified and as directed. NOTE: Excavation and foundation work shall be measured and paid separately.
Supply and Fix MCCB 4 pole 415 Volts adjustable type of capacity 63 Amps, 16 KA breaking capacity and connecting/testing complete all as specified and directed.
Supply and fix RCCB for Earth Leakage protection Double Pole, 30 mA with current rating up to 25A complete all as specified and as directed.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal ground level and connected to galvanized earth Lead wire 4.0mm dia (up to 7.5m fro electrode to test point) by means of bolts, nuts, check nuts and washers of galvanized iron steel protected by GI pipe 15mm bore light grade and watering pipe 20mm bore GI pipe medium grade all as shown in Electrical Plate No.3 connected to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC M20 nominal mix using 20mm graded aggregates, with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.
Material and labour Sub main/circuit wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable(FR) 1100 volts grade multi standard copper conductor drawn through and including rigid non-metallic PVC conduit of suitable size including all accessories as bend,tee,junction boxes elbows etc, fixed in walls/roof including one run of 6 sqmm earth continuity PVC insulated copper wire(FR) complete all as specified and as directed. Note : 3 runs of 6 Sqmm cable, one run of PVC conduit shall be measured as one length.
Supply and Fix enclosure for MCCB made out of sheet metal enclosure (CRCA sheet), dust and vermin proof complete all as specified and as directed. NOTE: MCCBs shall be measured and paid separately.
K.V.GEORGE AND COMPANY
M/s Antony Kallarakkal
Modern Engineering Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .