Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹1.6 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.6 Cr+₹42,775.21 (0.26%)Rejected-Finance | ₹1.6 Cr+₹42,775.21 (0.26%) | L2 | Rejected-Finance Being Not Lowest |
| 3 | L3₹1.7 Cr+₹7.2 L (4.40%)Rejected-Finance PLOT NO 19 PAOTA C 3RD ROAD JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹1.7 Cr+₹7.2 L (4.40%) | L3 | Rejected-Finance Being Not Lowest |
| 4 | L4₹1.8 Cr+₹21.2 L (13.0%)Rejected-Finance | ₹1.8 Cr+₹21.2 L (13.0%) | L4 | Rejected-Finance Being Not Lowest |
| 5 | L5₹1.9 Cr+₹22.9 L (14.0%)Rejected-Finance | ₹1.9 Cr+₹22.9 L (14.0%) | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
9 Jun 2023, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR
ADDN OR ALTN OR IMPROVEMENT TO R and D HANGER AT AF STN JODHPUR
2023_MES_578278_3
85974/E8
Open Tender
Civil Works
Item Rate
742 days
GE AF JODHPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE AF JODHPUR
₹2.2 L
Yes
4 Aug 2023
19 May 2023
12 Jun 2023
19 May 2023
9 Jun 2023
26 May 2023
19 May 2023 - 19 May 2023
Amount
Surface dressing n.exc 15cm deep and getting out in any type of soil.
Excavating over areas not exceeding 1.50m deep and getting out in any type of soil.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concreting.
M&L RCC M-25(Design Mix)Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete
M &L M-25(Design Mix ) in column,pillars piers posts and strus
M &L RCC M-25(Design Mix ) in beams, cantilever beams and lintel beams and linlet
M &L RCC M-25(Design Mix )as in slab supported on wall
M &L RCC M-25(Design Mix )as in chajja
Form work to foundation/footing, footing PBs and simallars works etc
Form work to side of footing of roof beam,lintel beam and simillars works etc
Form work to soffits of suspended slab floor slab , landing and similar works rough finish surface.
Form work to edge of concrete roof slab rough finish exc 10 cm but not exc 20 cm wide
Form work to sides of pillars post struts,Columns etc with rough finished surfaces of concrete of circular on plan rough finish surfaces
Pre-cast cement concrete block masonry with solid blocks of 1:3:6 type C1 concrete, exc. 10 cm in width and setting in cement mortar 1: 6 , complete
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 and finishing the plastered surface of wall even and smooth without using extra cement ( internal surface)
M&L for rendering 5mm thick in CM 1:3 on concrete surface including finish even and smooth surfaces using without extra cement on ceiling.
M & L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement(external surface)
M & L for Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM 1:3 on ceiling and finishing the plastered surface of wall even and smooth without using extra cement
M & L for broken stone/ boulders as in Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface
M&L for 75 mm thick PCC 1:3:6 type C-2(using 40 mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement.
M&L for 150 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in sub base. for floor
M&Lfor screed bed or bedding layer of 15 mm thick for laying floor finish with CM 1:6
M&Lcoloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for Glazed ceramic coloured tiles in vertical surfaces of minimum size 450 mm x 300 mm x 7-8 mm thick set and jointed in neat cement slurry and joints filled with white or coloured cement to mach complete all as specified and directed by Engineer-in-Charge”.
M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. NOTE : Water proofing compound shall be measured and paid for separately as “Supply only”
Supply only integral water proofing compound ISI marked.
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3 mm thick) with non-woven polyster reinforcement/mat (centre core) with thermal insulation with white mineral gravel finish on upper side of membrane laid by torch application method with overlaps 100mm on length side and 100 mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparation of newly plastered or unplastered surfaces and applying three coats of white wash on ceiling.
M&L preparing new plastered surfaces and applying two coat Oil emulsion distemper on walls.
M&L for preparing the newly plastered or unplastered surfaces and applying two coats of cement based paint on walls.
M&L 20 mm thick granite work (table rubbed and polished) on bar counter, cooking plateform, pillars, cill ,jambs, steps and like over 15 mm thick in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match including bull nosing the edge complete.
S&F factory made solid panel PVC door shutter 30mm thick with plain PVC sheet & 5mm thick x 15mm wide PVC sheet beading used inside styles and rails and jointed and gether with solvent cement, suppling and fixing in the frame at site as per specification and drawing.
S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing.
S&F Rolled sections as in joist, channel, angle or tee sections, fixed independently without connecting plates etc conforming to Fe-410-W (Gde E-250 quality-B)
M & L Preparing new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer
S&F 40 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated
M&L for Preparation of old painted wooden surfaces of any description over 10 cm width or girth & applying one coat of synthetic enamel paint over a coat of pink primer.
S&F powder coated aluminium window and ventilators shutters, side hung thpe without sash bars, aluminium sections weighing 0.55kg/m incl necessary joining cleat glazing clips, rubber packing, aluminium snap beading screws, fittings such as peg stays 100mm long (02 Nos) suitable handles (01 No) complete all as specified.
S&F Butt hinges, extruted aluminium alloy with with galvanised mild steel type C21 of size 100 mm.
S&F Butt hinges, extruted aluminium alloy with with galvanised mild steel type C21 of size 75 mm.
S&F Aluminium powder coated barrel tower bolt of extruded section 200mm size
S&F extructed aluminium alloy handles, fabricated type,anodised of size 150mm.
S&F Aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed size 300mm long.
M & L TMT bars 10mm dia and over, cut to length bent to shape required including crancking , bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conf to TMT bar
M&L M S TMT bars 8mm dia cut to length, bent to shape required including cranking bending & binding with mild steel wire(annealed) not less than 0.9mm dia confirming to Fe-410-0 or 310-0
ditto- but 5mm dia & over upto & incl 10mm dia in stirrups,spacer & binders.
M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in hold fast etc and similar works.
S&F stop valves cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle for 15mm bore.
S&F for PVC connections 15mm size with PTMT nuts of length 450mm
S & F 15 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
S & F 20 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
S&F vitreous china padestal pattern, coloured , including 100 mm CI connection piece& socket and PVC seat cover complete.
S&F PVC valve less, syphonic action type, flushing cistern, low level , white of 10 ltr of capcity including inlet , ball valve, float & handle incl brackets complete.
S&F vitreous china WHB coloured, flat back, size 550 x 400mm including brackets, 32mm Brass CP waste fitting, PVC waste pipe & 450mm PVC connection.pipe. Including vitreous china pedestal complete.
S&F pillar taps cast copper alloy fancy type with capstan heads, chromium plated, screw down high pressure with or W/O lettered Hot or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed 15mm bore.
S&F vitreous china bowl urinal, flat back, size 465 X 355 X 265mm (minimum) white with grating & union including 15 mm PTMT push tap any colour, PVC connection, brackets, spreader etc complete.
S&F Bib tap, cast copper alloy Chromium plated, fancy type, screwed down high pressure with crutch or butterfly handle for 15mm bore.
S&F 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints in floors/walls.
S/F PVC (SWR) vent cowl 110 mm in bore
S&F 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints laid in floors.
M&L 75mm PVC (SWR) floor trap, with grating including jointing with solvent cement.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball brass valve high pressure with polythyne float and flynut complete
S&F brass chromium plated Towel rail 20 mm dia, 600 mm long between flanges.
S&F PVC (SWR)110mm bore bend
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm
Dismantling Plain or corrugated Asbestos Cement sheeting, any gauge, thickness, including Nainital or similar pattern roof covering
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws compplete all as specified and as directed by Engr-in-Charge
S&F 1.60 mm thick mild steel plain black sheet in wall cladding and similar wks, cut to size holes punched including bending , turning etc
M&L for PU painting on steel surfaces in camouflage pattern complete all as specified and as directed.
M&L for complete removal of old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth and applying two coat of aluminium paint , Surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified
Providing 5mm thick high density EPU flooring includes priming , screed topping antistatic type including make in good to surface before application of low viscous epoxy primer having resin & hardner in equal volumes, approved by CPRI (Central power Research Institute Bangalore). Make- FOSROC/CIPY
S&F in repairs SS bird proof net of wire netting of stainless steel wire 0.91mm dia and size of mesh 20 X 20 mm fixed with tinned tacks of stainless steel wire staples
Providing and fixing and commissioning of wind driven turbo ventilators having average capacity of 1500 to 2000 CFM ,having neck diameter 700-750 mm and 42 nos fins.Top plate and bottom ring shall be made high grade stainless steel (SS-304)and fins to be made of high grade aluminium (H-14) of minium thickness 0.71 mm.The base and hopper shall be constructed of UV stabilized FRB of minimum thickness 3 mm matching with roof sheet profile. The rate shall be include fixing of FRP base along with ventilator and special leak proof tape should be used in between all four sides , making it totally water tight etc. The rate also includes all lead and lift, transportation materials, labours, taxes, etc complete. The work should be carryout as ditected by Engr-in-Charge.
S & F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0 (Brackets over 10kg each to be measured under `Structural Steel')
M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979/ IS 4923 - 1997
Excavating in post holes, in hard/dense soil, (or similar holes) each n. exc. 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50 m and making good surfaces complete all as specified and as directed by the Engr-in - Charge.
M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate cement concrete in foundations, filling and mass concrete.
S&F PVC (SWR) pipes 160mm bore single socketed in any length with rubber ring joints fixed to walls
S&F PVC (SWR) bends any radius 160mm dia
S&F 1.00 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275
M&L for points of contact of wood work by chemical emulsion( in oil or kerosene based solution) @0.5litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same.
M & L for Anodised aluminium powder coated of any colour (Thickness of powder coating not less than 50 micron) door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified
M & L for Powder Coted aluminium (Minimum thickness of pwder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed ortions) with extruded built up standard tubular sections/ approproate Z sections and toher sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasterners of required dia and size, including necessary filling up the gaps at jucntions, i.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium section shall be smooth, rust free, strtaight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. bars/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane
Supply & fixing 12 mm thick solid PVC ply of 1st quality of one side prelaminated of approved colour and one side white colour fixed with screw and solvent cement as in partition complete all as specified and directed by Engineer-in-charge.
S&F in repairs Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete
S&F in repairs Welded steel wire fabric weight not exceeding 4Kg/ sqm supplied and fixed complete to wood or steel members completre all as specified and directed.
Supply & fixing in repairs MS pulley size more than 20 cm dia with bearing shaft, nuts including making necessary arrangement for taking down old pulley at the bottom of sliding hanger door shutter complete all as specifed and directed.
Supply & fixing in repairs MS pulley size less than 20 cm dia with bearing shaft, nuts including making necessary arrangement for taking down old pulley at the bottom of sliding hanger door shutter complete all as specifed and directed.
M&L for squared rubble walling, Jodhpur type, brought up to courses, well bonded, bedded and solidly hearted, built in CM 1:6
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge n.exc 20mm and dressing face beds and joints as specified to squared rubble walling Jodhpur type, brought upto courses.
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surface including finished even and smooth (without using extra lime or cement).
S&F in repairs 30 mm thick IInd class hardwood wooden planks, planed one side, with butt joint and fixed with nails/screw complete all as specified and as directed.
S&F Anodised aluminium snap grid frame work of 600mm * 600mm for false ceiling all as specified
S&F Exposed metal frame ceiling with 8 mm thick calcium silicate board if siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid (Frame work for ceiling shall be measured and paid separately)
M&L for Preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st quality) over a coat of pink wood primer complete all as specified and directed.
M&L for Preparation of Old wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1stquality) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortor bedding (but not baking), removing servicable tiles to store and rubbish off the permises.
M&L 25mm thick PCC 1:2:4 type B-1 ( 20 mm graded stone aggre) as in sub base for tiles in floors .
M & L for vetrified tilesof size 600mmX600mmX8-10mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement laid over and including15 mm thick screed bed in cm 1:4.
S&F pressed steel door shutters including stiffners made out of mild steel sheet 1.0 mm thick cut to size, holes punched and welded seams including bending and turning up all around, mitred angles etc as required and applying a shop coat of of zinc primer all as per godrej pasttern and asd directedby Engineer-in Charge. Note :- (i) Quoted rate shall deemed to be include 100 mm 6 liver brass mortice lock on each door. (ii) Stiffners of 150 mm girthand height equal to height of shutter made out to shape as directed by Engineer-in Charge shall be provided to each leaf. Cost of these stiffners shall be deemed to be included in the unit rate quated for door shutters.
S&F pressed steel rectangular frames for built in cub boards doors, made out of mild steel sheet 1.25 mm thick with girth of frame 185 mm including neccesary raw plugs and fixing 75 mm long butt hinges medium weight cold rolled mild steel iuncluding applying a shop coat of zinc chromate primer complete all as specified.
Taking down hanger door leafs, repairing and fixing in same position including minor repairs like welding, alignment etc. Note (i) Member of gate to be changed should me measured in respective items.
Demolition of bituminous carpet including removal of demolished material outside MoD land complete all as specified and directed
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth ; for foundation etc. or for shafts, wells, cesspits, manholes. Pier holes, etc hard/dense soil. n exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil.
M&L for 250mm thick cement concrete work in pavement/hard standing of flexxural strength 30 kg/per square centimetre in field using 400 kg of cement per cubic metre.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'B".
Demolition of PQC of any description in any position ground floor exc 15 cm complete all as specified and as directed
M&L high density polytheene film (transperent colour) in single layer of 400 Micron thickness virgin quality as per ASTMD 2103/IS 2508 laid with side and overlapping not less than 300 mm complete all as specified and as directed.
M&L fo applying evenly a Priming/tack coat with paving bitumen VG 10 at 2.5 kg per 10 Sqm all as specified and as directed
M & L 275 mm PQC work in pavement of flexural strength 45 Kg/sqcm (lower control limit) in field using min 400 kg and n.exc 450 Kg of cement per cubit metre as per design mix mixed with and incl triangular/non circular synthetic fiber reinforcement @ 0.25% by wt of cement spread and compacted by using slip form paver and all as specified and incl necessary form work, bull nosing rounding of edges , finishing by mechanical brooming/belting/curing etc complete all as specified and as directed. Note:- Admixture and polyester triangular fober shall be payed seperatly under respective items.
Supply only polyster triangular fibre @ 0.25 % by weight of cement
Material and labour for 125 mm thick dry lean concrete (DLC) of compressive strength not less than 10 Mpa at 07 days with minimum cement content 240 Kg/ Cum using grading as per MORTH specification and as per designed mix spread rolled and consolidated to required camber and gradient using necessary mechanical sensor paver and tendem vibratory roller of capacity 8 to 10 tonnes complete all as specified and directed
Material and labour for forming 25mm thick expansIon joint by full depth diamond cutter, filled with DURA board HD-100 (Brand supreme or equivalent as approved), applying bond breaker tape on top of board for complete depth of joint i.e. the thick ness of concete slab, provisikon of closed celled polyurethane sealant (Minimum depth of sealant above backup rod shall be 15 mm), complying with BS- 4254 and EN 41875 2003 priming the sides minimum MAF or 30% with ten years performance quarantee and applying masking tape on edges of joint to prevent accidental spillage of sealant on top surface and to give neat finish to th sealant and removing the masking trape after sealant is applied for thickness of concrete slab minimum 275 mm and maximum 400 mm complete all as specified and directed.
Material and labour forming construction joint, 30 mm deep and 10 mm wide (using diamond cutter) providing polyurethane sealant (Minimum depth of sealant 12 mm), complying with BS 5212, BS 4254 and EN 41875-2003 priming the sides minimum MAF + 30% with ten years performance guarantee and applying maksing tape on edge of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant as shown on drawing and removing the masking trape after sealant is applied complete all as specified and directed.
Material and labour for forming contraction(dummy joint), 65mm deep and 10 mm wide (using diamond cutter) filled with polyurethane sealant (Minimum depth of sealant 12 mm) complying with BS : 5212 and fixing 10mm dia polyurethane rod and applying masking tape on edge jof joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant in positioin as required jcomplete all as per manufacturer's instructioins complte all as specified and directed.
Excavation in trenches n.exc 1.50mtr wide and n.exc 1.50mtr in depth ,for foundation etc or for shaft wall, cesspits, man holes pier holes etc n.exc 10 sqm on plan and n.exc 1.50 mtr in depth and getting out in soft/loose soil
PCC 1:3:6 type C1 using 20mm graded trap stone aggrgate in coping.
Pre cast RCC cover slab 1: 2: 4 type B1 using 20mm graded trap stone agg set CM 1:4.
M&L Rendering in CM 1:4 10mm thick in concrete surface finished even and smooth without using extra cement.
PCC type B 1:2:4 20mm graded aggregate for benching.
Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in Cement concrete 1:3:6 type C-2 Bore of pipe in 150mm complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for salt glazed stone ware pipes 150 mm internal dia, Grade ‘A’ laid in trenches and jointed as specified.
Removing excavated meterial outside MoD land at a place identified by the contractor at his own cost.
M&L for PCC 1:3:6 type C2 (Using 40 mm graded stone aggregate) as in bed to drain complete all as specified and as directed
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate ) as in drains etc complete all as specified and as directed
M&L for PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) as in coping to drains etc complete all as specified and as directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and as directed
Add for each 25 mm girth or part there of over or under 30 cm girth complete all as specified and as directed
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, conforming to Fe 410-0 or Fe 310-0
Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete,such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
Taking down MCB DB with MCB any type and any capacity all as specified and directed by Engineer-in-Charge.
Taking down Sub main wiring any type any size from wall all as specified and directed by Engineer-in-Charge.
Dismantling existing sub main wiring in steel conduit from top of hanger roof sheet with carefully and refixed after repair of roof with fixing material
Dismantling and refixing of light fittings and ceiling fan any size, any make and any watts with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 SSR Part-I and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, precast RCC 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore midium grade GI protection pipe, test point etc complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Ditto,as per item above but using galvanised iron strip 32×6mm as earthing lead and 40mm dia GI pipe light grade for protection pipe.
S&F sub main wiring with 2 run of 2.5 Sqmm single core (for phase & neutral and 1 run of 1.5 Sqmm single core (for earth) multistranded copper conductor FRLS 1100 volt grade IS- 694 marked drawn through and including in steel conduit pipe medium grade ISI marked (not less than 20 mm dia)along with fittings and accessories all fixed concealed on wall and surface on ceiling and also including the specified runs of specified size earth continuity conductor of similar type of cable complete all as specified and directed by Engineer in charge. (2 runs of main cable one run of earth wire one run of steel pipe will be measured as an one run) (a) All runs of cable and one run of steel conduit shall be measured and paid as one meter length of unit.
All as per Item above but 2 Run of 6 Sqmm cable and one run of 4 sqmm cable for earth wire
All as per Item above but 2 Run of 4 Sqmm cable and one run of 2.5 sqmm cable for earth wire
M&L in repair point wiring with 1.5sqmm PVC insulated 1100 volt grade IS -694 FRLS multi stranded but unsheathed copper conductor cable drawing in PVC casing capping and terminated in existing terminal box with 3 mm thick plastic laminated sheet cover for fixing of switches,sockets and fan regulator including continuous earth wire with copper cable S/C 1.5 sq mm similar description of main cable connected to main earth dully complete all as specified and directed by Engineer in Charge. (a) one light/ fan/Exhaust fan point controlled by one switch.
(b) -do- as above but for 5 amp socket on same board
(c) -do- as above but for 5 amp socket on independent board
(d) -do- all as above but for One bell point controlled by one bell push.
(e) All as per item above but with 2.5 Sq mm cable for Independent one 6 pin 5/15 Amps socket outlet In and including 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire.
S & F switch piano flush type 250 volts ISI marked 5 amps flush type single pole one way
S & F switch piano flush type 250 volts ISI marked 16 amps flush type single pole one way
S & F socket outlet multi-purpose 2 in 1, 5 pin 5/6 amps
S & F socket outlet multi-purpose 2 in 1, 6 pin 15/16 amps 230 volts ISI marked flush type
Supply and fix Switch Bell push flush type, 5 Amps 240 volts.
Supply and fix Buzzer ding dong , AC, 230 Volts, Single pole.
Supply and fix Ceiling rose, 3 phase/PVC/ Poly carbonate 65 x 17 mm 3 terminals isolated body .
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd.
S & F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43-IK with reversal double door, recess mounted, having insulated 200 amp tinned copper bus bar , neutral bus bar, earth bar, din bar detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways.
S & F in replacement MCB SP, 6 to 32 amp, 10 KA, 'Ç'series
S & F in replacement MCB SPN, 6 to 32 amp, 10 KA, 'B'series
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers all as specified and directed by Engineer-in-Charge.
Supply & fix Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting all as specified and directed by Engineer-in-Charge.
Supply and fix in TPN DB- VTPN DPX 160 MCCB DBs 12 way suitable for flush mounting and surface mounting with 250 amp copper bus bar for each phase with 2 neutral, 2 earth bar and cable ties for cable manegement , fully insulated bus bar & shrouded neutral bar/improved Pan assembly for ease of installation, prefitted masking sheet, reversible door for IP 43 & IP 54 with provision for 160 amp MCCB as incommer and SP/TP/MCBs as out going. Make : Legrand Cat No 5077 48 with metal door. 1. Incommer MCCB,160 Amp,4P,25 KA-01, Outgoing MCB TPN,40 Amp,440 Volt-02 Nos,MCB DP ,240 Volt,6-32 Amp-15 Nos.
Supply and fix LED Highbay optibeam light 100W, cast aluminium housing highbay with polycarbonate lenses, suitable for industrial lighting using hook/ cradle mounting option. IP 65 option avalable and all as directed.Make : Shakti Cat No. SZHHAMX100
Supply, fixing, installation, testing & commission air cooled inverter type with non CFC gas split air conditioner capacity 2 TR, BEE 5 star rating comprising of indoor & outdoor unit. The evaporator & condenser coil shall be made of copper, including control wiring, stand for fixing outdoor unit on wall/floor insulated copper tubing for connection the indoor and outdoor. Note:- The cost of copper tubing & control wire upto 3 Mtr shall deemed to be included in quoted rate.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 05 KVA
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps,240 volts all as specified and directed by Engineer-in-Charge.
KAY CEE CO. INDIA
New Vishvakarma Udhyog
Jeet Construction
RISING ELECTRICALS
M/S RAM SINGH AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .