Special repair work at JNV Puri (Odisha)
NBCC/SBG/ODISHA/NIT/25-26/61
NBCC/SBG/ODISHA/NIT/25-26/61
Open Tender-Domestic
Civil Works - Buildings
Puri, Odisha
₹11,800
₹1.3 L
21 Jul 2026
26 Feb 2026
9 Mar 2026
9 Mar 2026
16 Mar 2026
NAME OF WORK: Special repair work at JNV Puri (Odisha)
SUMMARY OF COST
Sl.No Description Amount on Amount on
DSR-2023 Non- DSR
1 School Building 38.05
2 Kitchen / Dining 12.07
3 Girls Dormitories (1 blocks ) 44.59 0.84
4 Boys Dormitories 192 bedded (1 Block) 21.09
5 Boys Dormitories 96 bedded (1 Block) 9.14 0.08
6 Staff Quarters -Type-IV (1 Block) 1.15
7 Staff Quarters -Type-I (2 Block)(G) 2.02
8 Staff Quarters -Type-II (4 Block)(G+1) 3.64
Sub Total 131.75 0.92
G.Total 132.67
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV KONARK, PURI, ODISHA.
BILL OF QUANTITY FOR SCHOOL BUILDING
Sl. DSR- Description Qty Unit DSR Rate Non-DSR Amount On Amount On
No. 2023 (In Rs.) Rate DSR - 2023 Non- DSR (In
(I) STRUCTURE REPAIR & RETROFITTINGS
Expansion Joint Treatment
1 5.45 Providing and fixing of expansion joint system related with wall joint (internal/
external) location as per drawings and direction of Engineer-In- Charge. The
joints shall be of extruded aluminum base members, self aligning / centering
arrangement and support plates as per ASTM B221- 02. The material shall
be such that it provides an Expansion Joints System suitable for vertical
wall to wall/ wall to corner application, both new and existing construction in
office Buildings & complexes with no slipping down tendency amongst the
components of the Joint System. The Joint System shall utilize light weight
aluminum profiles exhibiting minimal exposed aluminum surfaces
mechanically snap locking the multicellular to facilitate movement. (Material
shall confirm to ASTM 6063).
2 5.46 Providing and fixing of expansion joint system of approved make and
manufacture for various roof locations as per approved drawings and
direction of Engineer-In-Charge. The joints shall be of extruded aluminum
base members with, self aligning and self centering arragement support
plates as per ASTM B221-02. The system shall be such that it provides
water tight roof to roof /roof to corner joint cover expansion control system
that is capable of accommodating multidirectional seismic movement without
stress to its components. System shall consist of metal profile that
incorporates a universal aluminum base member designed to accommodate
various project conditions and roof treatments. The cover plate shall be
designed of width and thickness required to satisfy movement and loading
requirements and secured to base members by utilizing manufacturer’s pre-
engineered self-centering arrangement that freely rotates / moves in all
directions. The Self centering arrangement shall exhibit circular sphere ends
that lock and slide inside the corresponding aluminum extrusion cavity to
allow freedom of movement and flexure in all directions including vertical
displacement. The Joint System shall resists damage or deterioration from
the impact of falling ice, exposure to UV, airborne contaminants and
occasional foot traffic from maintenance personnel. Provision of Moisture
Barrier Membrane in the Joint System to have water tight joint is mandatory
requirement. (Material shall confirm to ASTM 6063.)
TOTAL AMOUNT (STRUCTURE REPAIR & RETROFITTINGS): 3,06,589.06 -
TOTAL AMOUNT (STRUCTURE REPAIR & RETROFITTINGS): 3,06,589.06 -
(II) REPAIRS TO ROOF
3 14.91.1 Providing and laying APP (Atactic Polypropylene Polymer) modified
prefabricated five layer 3 mm thick water proofing membrane, black finished
reinforced with non-woven polyester matt consisting of a coat of bitumen
primer for bitumen membrane @ 0.40 litre/sqm by the same membrane
manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps.
Over the primer coat the layer of membrane shall be laid using Butane Torch
and sealing all joints etc, and preparing the surface complete.
The vital physical and chemical parameters of the membrane shall be as
under : Joint strength in longitudinal and transverse direction at 23°C as
650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as
300/250N. Softening point of membrane not less than 150°C. Cold flexibility
shall be upto 2°C when tested in accordance with ASTM, D - 5147. The
laying of membrane shall be got done through the authorised applicator of
the manufacturer of membrane :
4 14.92 Extra for covering top of membrane with Geotextile, 120 gsm non woven,
100% polyester of thickness 1 to 1.25 mm bonded to the membrane with
intermittent touch by heating the membrane by Butane Torch as per
manufactures recommendation. 2996.79 Sqm 86.50 2,59,221.44
5 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) 202.69 Cum 7825.16 15,86,081.25
TOTAL AMOUNT (REPAIRS TO ROOF): 34,80,963.71 -
TOTAL AMOUNT (REPAIRS TO ROOF): 34,80,963.71 -
6 8.10.2 Providing and fixing stone slab with table rubbed, edges rounded and
polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinalpartitions by
cutting a chase of appropriate width with chase cutter and embedding the
stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per
direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
TOTAL AMOUNT (REPAIRS TO TOILETS) 17,741.03 -
TOTAL AMOUNT (REPAIRS TO TOILETS) 17,741.03 -
GRAND TOTAL AMOUNT: 38,05,293.80 -
GRAND TOTAL AMOUNT: 38,05,293.80 -
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV KONARK, PURI, ODISHA.
BILL OF QUANTITY FOR KITCHEN & DINING
Sl. DSR- Description Qty Unit DSR Rate Non-DSR Amount On Amount On
No. 2023 (In Rs.) Rate DSR - 2023 Non- DSR
(i) Structural Repair & Retrofitting
1 26.28 Chipping of unsound/weak concrete material from slabs, beams,
columns etc. with manual Chisel and/ or by standard power driven
percussion type or of approved make including tapering of all edges,
making square shoulders of cavities including cleaning the exposed
concrete surface and reinforcement with wire brushes etc. and
disposal of debris for all lead and lifts all complete as per direction of
Engineer-In-Charge
A 26.28.2 50mm average thickness 9.00 Sqm 249.43 2,244.86
B 26.28.3 25 mm average thickness 4.50 Sqm 123.33 554.97
2 26.29 Cleaning of reinforcement from rust from the reinforcing bars to give it
a total rust free steel surface by using alkaline chemical rust remover
of approved make with paint brush and removing loose particles after
24 hours of its application with wire brush and thoroughly washing with
water and allowing it to dry, all complete as per direction of Engineer-
26.29.1 Bars upto 12 mm diameter 216.00 Mtr 8.03 1,733.89
3 26.37 Cleaning of exposed concrete surface of sticking material including
loose and foreign material by sand blasting with coarse sand followed
by and including cleaning with oil free air blast as per direction of
Engineer in charge. 46.89 Sqm 372.08 17,446.61
4 26.38 Shotcreting R.C.C. columns, beams and slabs etc. in layers with
approved design mix concrete having the specified minimum
characteristic compressive strength [with ordinary portland cement,
coarse sand and graded stone aggregate of 10 mm maximum size in
proportion as per design criteria] including the cost of centering and
shuttering at edges and corners etc. as directed by Engineerin-
A 26.38.1 25mm thick in Grade M 25 with cement content not less than 330 kg
B 26.38.2 50mm thick in Grade M 25 with cement content not less than 330 kg
Expansion Joint Treatment
5 5.45 Providing and fixing of expansion joint system related with wall joint
(internal/ external) location as per drawings and direction of Engineer-
In- Charge. The joints shall be of extruded aluminum base members,
self aligning / centering arrangement and support plates as per ASTM
B221- 02. The material shall be such that it provides an Expansion
Joints System suitable for vertical wall to wall/ wall to corner
application, both new and existing construction in office Buildings &
complexes with no slipping down tendency amongst the components
of the Joint System. The Joint System shall utilize light weight
aluminum profiles exhibiting minimal exposed aluminum surfaces
mechanically snap locking the multicellular to facilitate movement.
(Material shall confirm to ASTM 6063).
6 5.46 Providing and fixing of expansion joint system of approved make and
manufacture for various roof locations as per approved drawings and
direction of Engineer-In-Charge. The joints shall be of extruded
aluminum base members with, self aligning and self centering
arragement support plates as per ASTM B221-02. The system shall
be such that it provides water tight roof to roof /roof to corner joint
cover expansion control system that is capable of accommodating
multidirectional seismic movement without stress to its components.
System shall consist of metal profile that incorporates a universal
aluminum base member designed to accommodate various project
conditions and roof treatments. The cover plate shall be designed of
width and thickness required to satisfy movement and loading
requirements and secured to base members by utilizing
manufacturer’s pre-engineered self-centering arrangement that freely
rotates / moves in all directions. The Self centering arrangement shall
exhibit circular sphere ends that lock and slide inside the
corresponding aluminum extrusion cavity to allow freedom of
movement and flexure in all directions including vertical displacement.
The Joint System shall resists damage or deterioration from the
impact of falling ice, exposure to UV, airborne contaminants and
occasional foot traffic from maintenance personnel. Provision of
Moisture Barrier Membrane in the Joint System to have water tight
joint is mandatory requirement. (Material shall confirm to ASTM 6063.)
SUB TOTAL 3,65,215.78 -
Digitally signed by JAYA
Sl. DSR- Description Qty Unit DSR Rate Non-DSR Amount On Amount On
No. 2023 (In Rs.) Rate DSR - 2023 Non- DSR
(ii) Repairs to Roof
7 14.91.1 Providing and laying APP (Atactic Polypropylene Polymer) modified
prefabricated five layer 3 mm thick water proofing membrane, black
finished reinforced with non-woven polyester matt consisting of a coat
of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the
same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre
and viscocity 70-160 cps. Over the primer coat the layer of membrane
shall be laid using Butane Torch and sealing all joints etc, and
preparing the surface complete.
The vital physical and chemical parameters of the membrane shall be
as under : Joint strength in longitudinal and transverse direction at
23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse
direction as 300/250N. Softening point of membrane not less than
150°C. Cold flexibility shall be upto 2°C when tested in accordance
with ASTM, D - 5147. The laying of membrane shall be got done
through the authorised applicator of the manufacturer of membrane :
8 14.92 Extra for covering top of membrane with Geotextile, 120 gsm non
woven, 100% polyester of thickness 1 to 1.25 mm bonded to the
membrane with intermittent touch by heating the membrane by
Butane Torch as per manufactures recommendation. 663.42 Sqm 86.50 57,385.63
9 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) 49.75 Cum 7825.16 3,89,301.61
10 Analysis Repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy
based dampgaurd (Dr. Fixit Make) , including cutting the area of
plaster in proper shape, raking out joints and preparing and plastering
the surface of the walls complete, including disposal of rubbish to the
dumping ground, all complete as per direction of Engineer-in-
Charge.With cement mortar 1:4 (1cement: 4 coarse sand)
TOTAL AMOUNT 8,42,028.40 -
TOTAL AMOUNT 8,42,028.40 -
GRAND TOTAL AMOUNT: 12,07,244.18 -
GRAND TOTAL AMOUNT: 12,07,244.18 -
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV KONARK, PURI, ODISHA.
BILL OF QUANTITY FOR GIRLS DORMITORY (G+1) 1 BLOCK FOR 192 STUDENTS
Sl. DSR- Description Qty Unit DSR None Amount On Amount On
No. 2023 Rate DSR DSR-2023 Non- DSR
(In Rs.) Rate (In Rs.) (In Rs.)
(i) Structural Repair & Retrofitting
1 26.28 Chipping of unsound/weak concrete material from slabs,
beams, columns etc. with manual Chisel and/ or by
standard power driven percussion type or of approved
make including tapering of all edges, making square
shoulders of cavities including cleaning the exposed
concrete surface and reinforcement with wire brushes
etc. and disposal of debris for all lead and lifts all
complete as per direction of Engineer-In-Charge
A 26.28.2 50mm average thickness 22.50 Sqm 249.43 5,612.14
B 26.28.3 25 mm average thickness 30.00 Sqm 123.33 3,699.83
2 26.29 Cleaning of reinforcement from rust from the reinforcing
bars to give it a total rust free steel surface by using
alkaline chemical rust remover of approved make with
paint brush and removing loose particles after 24 hours
of its application with wire brush and thoroughly washing
with water and allowing it to dry, all complete as per
direction of Engineer-In-Charge.
26.29.1 Bars upto 12 mm diameter 840.00 Mtr 8.03 6,742.89
3 26.37 Cleaning of exposed concrete surface of sticking material
including loose and foreign material by sand blasting with
coarse sand followed by and including cleaning with oil
free air blast as per direction of Engineer in charge.
4 26.38 Shotcreting R.C.C. columns, beams and slabs etc. in
layers with approved design mix concrete having the
specified minimum characteristic compressive strength
[with ordinary portland cement, coarse sand and graded
stone aggregate of 10 mm maximum size in proportion
as per design criteria] including the cost of centering and
shuttering at edges and corners etc. as directed by
Engineerin- Charge
Note: Rates shall include the providing necessary ground
wires etc. The levelling gauges, if used, shall be paid for
separately. Payment under this item shall be made only
after proper wet curing has been done and surface has
been satisfactorily evaluated by sounding/ tapping with a
blunt metal instrument.
A 26.38.1 25mm thick in Grade M 25 with cement content not less
than 330 kg per cum 30.00 Sqm 726.73 21,802.01
Expansion Joint Treatment
Digitally signed by JAYA
5 5.44 Providing and fixing of expansion joint system related
with floor location as per drawings and direction of
Engineer-In-Charge. The joints system will be of extruded
aluminum base members, self aligning / self centering
arrangement and support plates etc. as per ASTM B221-
02. The system shall be such that it provides floor to floor
/floor to wall expansion control system for various vertical
localtion in load application areas that accommodates
multi directional seismic movement without stress to it's
components. System shall consist of metal profiles with a
universal aluminum base member designed to
accommodate various project conditions and finish floor
treatments. The cover plate shall be designed of width
and thickness required to satisfy projects movement and
loading requirements and secured to base members by
utilizing manufacturer’s pre-engineered self- centering
arrangement that freely rotates / moves in all directions.
The Self - centering arrangement shall exhibit circular
sphere ends that lock and slide inside the corresponding
aluminum extrusion cavity to allow freedom of movement
and flexure in all directions including vertical
displacement. Provision of Moisture Barrier Membrane in
the Joint System to have watertight joint is mandatory
requirement all as per the manufactures design and as
approved by Engineer -in- Charge. (Material shall confirm
6 5.45 Providing and fixing of expansion joint system related
with wall joint (internal/ external) location as per drawings
and direction of Engineer-In- Charge. The joints shall be
of extruded aluminum base members, self aligning /
centering arrangement and support plates as per ASTM
B221- 02. The material shall be such that it provides an
Expansion Joints System suitable for vertical wall to wall/
wall to corner application, both new and existing
construction in office Buildings & complexes with no
slipping down tendency amongst the components of the
Joint System. The Joint System shall utilize light weight
aluminum profiles exhibiting minimal exposed aluminum
surfaces mechanically snap locking the multicellular to
facilitate movement. (Material shall confirm to ASTM
7 5.46 Providing and fixing of expansion joint system of
approved make and manufacture for various roof
locations as per approved drawings and direction of
Engineer-In-Charge. The joints shall be of extruded
aluminum base members with, self aligning and self
centering arragement support plates as per ASTM B221-
02. The system shall be such that it provides water tight
roof to roof /roof to corner joint cover expansion control
system that is capable of accommodating multidirectional
seismic movement without stress to its components.
System shall consist of metal profile that incorporates a
universal aluminum base member designed to
accommodate various project conditions and roof
treatments. The cover plate shall be designed of width
and thickness required to satisfy movement and loading
requirements and secured to base members by utilizing
manufacturer’s pre-engineered self-centering
arrangement that freely rotates / moves in all directions.
The Self centering arrangement shall exhibit circular
sphere ends that lock and slide inside the corresponding
aluminum extrusion cavity to allow freedom of movement
and flexure in all directions including vertical
displacement. The Joint System shall resists damage or
deterioration from the impact of falling ice, exposure to
UV, airborne contaminants and occasional foot traffic
from maintenance personnel. Provision of Moisture
Barrier Membrane in the Joint System to have water tight
joint is mandatory requirement. (Material shall confirm to
Digitally signed by JAYA
TOTAL AMOUNT 3,08,003.34 -
TOTAL AMOUNT 3,08,003.34 -
(ii) Repairs to Roof
8 14.91.1 Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer 3 mm thick
water proofing membrane, black finished reinforced with
non-woven polyester matt consisting of a coat of bitumen
primer for bitumen membrane @ 0.40 litre/sqm by the
same membrane manufacture of density at 25°C, 0.87-
0.89 kg/ litre and viscocity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane
Torch and sealing all joints etc, and preparing the surface
The vital physical and chemical parameters of the
membrane shall be as under : Joint strength in
longitudinal and transverse direction at 23°C as 650/
450N/ 5cm. Tear strength in longitudinal and transverse
direction as 300/250N. Softening point of membrane not
less than 150°C. Cold flexibility shall be upto -2°C when
tested in accordance with ASTM, D - 5147. The laying of
membrane shall be got done through the authorised
applicator of the manufacturer of membrane :
9 14.92 Extra for covering top of membrane with Geotextile, 120
gsm non woven, 100% polyester of thickness 1 to 1.25
mm bonded to the membrane with intermittent touch by
heating the membrane by Butane Torch as per
manufactures recommendation. 1,647.79 Sqm 86.50 1,42,533.34
10 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) 99.13 Cum 7825.16 7,75,707.90
TOTAL AMOUNT 18,17,612.19 -
TOTAL AMOUNT 18,17,612.19 -
(iii) Repair to Toilets
11 15.2 Demolishing cement concrete manually/ by mechanical
means including disposal of material within 50 metres
lead as per direction of Engineer - in - charge.
A 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c
equivalentdesign mix) 4.80 Cum 2368.53 11,368.92
12 15.23 Dismantling tile work in floors and roofs laid in cement
mortar including stacking material within 50 metres lead.
15.23.1 For thickness of tiles 10 mm to 25 mm 221.28 Sqm 71.42 15,803.42
13 11.41A.3.1 Providing and laying Vitrified tiles in floor in different
sizes (thickness to be specified by the manufacturer) with
water absorption less than 0.08% and conforming to
IS:15622, of approved brand & manufacturer, in all
colours and shade, laid on 20 mm thick cement mortar
1:4 (1 cement: 4 coarse sand) jointing with grey cement
slurry @3.3 kg/sqm including grouting the joints with
white cement and matching pigments etc. The tiles must
be cut with the zero chipping diamond cutter only . Laying
of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber
mallet for placing the tiles gently and easily.Glazed
Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600
14 Analysis Providing and fixing Ist quality Glazed vitrified tiles
polished finish of size 450 x 600 mm tiles conforming to
IS: 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades
except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of
steps and dados, over 12 mm thick bed of cement mortar
1:3 (1 cement : 3 coarse sand) and jointing with grey
cement slurry @ 3.3kg per sqm, including pointing in
white cement mixed with pigment of matching shade
Digitally signed by JAYA
15 22.5 Providing and laying water proofing treatment in sunken
portion of WCs, bathroom etc., by applying cement slurry
mixed with water proofing cement compound consisting
of applying : a) First layer of slurry of cement @ 0.488
kg/sqm mixed with water proofing cement compound @
0.253 kg/sqm. This layer will be allowed to air cure for 4
hours. b) Second layer of slurry of cement @ 0.242
kg/sqm mixed with water proofing cement compound @
0.126 kg/sqm. This layer will be allowed to air cure for 4
hours followed with water curing for 48 hours. The rate
includes preparation of surface, treatment and sealing of
all joints, corners, junctions of pipes and masonry with
polymer mixed slurry.
16 MR Providing and filling of cinder in sunken portions. 2.94 CUM 2,374.40 6,980.74
17 15.56 Dismantling old plaster or skirting raking out joints and
cleaning the surface for plaster including disposal of
rubbish to the dumping ground within 50 metres lead.
18 15.60 Disposal of building rubbish / malba / similar
unserviceable, dismantled or waste materials by
mechanical means, including loading, ransporting,
unloading to approved municipal dumping ground or as
approved by Engineer-in-charge, beyond 50 m initial
lead, for all leads
including all lifts involved. 9.33 Cum 256.82 2,396.16
19 13.91 Removing dry or oil bound distemper, water proofing
cement paint and the like by scrapping, sand papering
and preparing the surface smooth including necessary
repairs to scratches etc. complete. 634.43 Sqm 24.47 15,525.10
20 13.5 15mm cement plaster on rough side of single or half
brick wall of mix
21 13.16 6mm cement plaster to ceiling of mix :
22 13.82 Wall painting with acrylic emulsion paint, having VOC
(Volatile Organic Compound) content less than 50
grams/ litre, of approved brand and manufacture,
including applying additional coats wherever required, to
achieve even shade and colour.
23 13.81 Distempering with 1st quality acrylic distemper (ready
mixed) having VOC (Volatile Organic Compound )
content less than 50 gram/ litre, of approved brand and
manufacturer including applying additional coats
wherever required to achieve even shade and colour
13.81.1 Old work (one or more coats)
13.81.1 Old work (one or more coats) 634.43 Sqm 61.01 38,704.73
24 13.80 Providing and applying white cement based putty of
average thickness 1 mm, of approved brand and
manufacturer, over the plastered wall surface to prepare
the surface even and smooth complete. 191.30 Sqm 151.84 29,046.35
25 15.12 Dismantling doors, windows and clerestory windows
(steel or wood) shutter including chowkhats, architrave,
holdfasts etc. complete and stacking within 50 metres
15.12.1 Of area 3 sq. metres and below 25.00 Each 357.29 8,932.14
26 15.13 Taking out doors, windows and clerestory window
shutters (steel or wood) including stacking within 50
15.13.1 Of area 3 sq. metres and below 9.00 Each 139.63 1,256.63
27 14.5 Renewing glass panes, with putty and nails wherever
including racking out the old putty: -
14.5.1 Float glass panes of nominal thickness 4 mm
(weight not less than 10kg/sqm) 7.20 Sqm 1061.20 7,640.66
Digitally signed by JAYA
28 14.9 Renewal of old putty of glass panes (length) 36.00 Mtr 54.63 1,966.82
29 9.48.1 Providing and fixing M.S. grills of required pattern in
frames of windows etc. with M.S. flats, square or round
bars etc. including priming coat with approved steel
primer all complete .Fixed to steel windows by welding
30 9.68 Providing and fixing oxidised M.S. casement stays
(straight peg type) with necessary screws etc. complete
9.68.1 300 mm weighing not less than 200gms. 20.00 Each 65.58 1,311.60
31 9.70 Providing and fixing IS : 12817 marked stainless steel
butt hinges with stainless steel screws etc. complete :
32 MR Providing & fixing Stainless steel sliding door bolts ISI
marked anodised (anodic coating not less than grade AC
10 as per IS : 1868) transparent or dyed to required
colour or shade with nuts and screws etc complete. (a)
33 MR Providing and fixing stainless steel towerbolts (barrel
type) with necessary screws etc. complete. -
34 9.165 Providing and fixing bright /matt finished Stainless Steel
handles of approved quality & make with necessary
screws etc all complete. (a) 125 mm.
35 9.101 Providing and fixing aluminium hanging floor door
stopper ISI marked anodised (anodic coating not less
than grade AC 10 as per IS : 1868) transparent or dyed
to required colour or shade with necessary screws etc.
9.101.2 Twin rubber stopper 24.00 Each 70.40 1,689.52
36 8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror
polished, premoulded and prepolished, machine cut for
kitchen platforms, vanity counters, window sills, facias
and similar locations of required size,approved shade,
colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated with
white cement, mixed with matching pigment, epoxy touch
ups, including rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at all levels.
Area of slab upto 0.50 sqm
37 9.122 Providing and fixing to existing door frames. -
9.122.2 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush
door shutter in different plain and wood finish made with
fire retardant grade unsaturated polyester resin, moulded
to 3 mm thick FRP laminate all around, with suitable
wooden blocks inside at required places for fixing of
fittings and polyurethane foam PUF)/ Polystyrene foam to
be used as filler material throughout the hollow panel,
casted monolithically with testing parameters of F.R.P.
laminate conforming to table - 3 of IS: 14856, complete
as per direction of Engineer-in-charge.
38 10.11 Providing and fixing factory made ISI marked steel
glazed doors, windows and ventilators, side /top /centre
hung, with beading and all members such as F7D, F4B,
K11 B and K12 B etc. complete of standard rolled steel
sections, joints mitred and flash butt welded and sash
bars tenoned steel sections, joints mitred and flash butt
welded and sash bars tenoned and riveted, including
providing and fixing of hinges, pivots, including priming
coat of approved steel primer, but excluding the cost of
other fittings, complete all as per approved design,
(sectional weight of only fittings, complete all as per
approved design, (sectional weight of only steel members
shall be measured for payment).
Digitally signed by JAYA
10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in
cement concrete block 15x10x10 cm of C.C. 1:3:6 (1
Cement : 3 coarse sand : 6 graded stone aggregate 20
mm nominal size 129.60 Kg 127.51 16,525.51
39 10.15 Providing and fixing M.S. Tubular frames for doors,
windows, ventilators and cupboard with rectangular/ L-
Type sections, made of 1.60 mm thick M.S. Sheet, joints
mitred, welded and grinded finish, with profiles of
required size, including fixing of necessary butt hinges
and screws and applying a priming coat of approved steel
10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in
cement concrete block 15x10x10 cm of C.C. 1:3:6 (1
Cement : 3 coarse sand : 6 graded stone aggregate 20
mm nominal size) 35.06 Kg 189.93 6,658.93
40 10.30 Providing & fixing glass panes with putty and glazing clips
in steel doors,windows, clerestory windows, all complete
10.30.1 4.0 mm thick glass panes 7.20 Sqm 1035.90 7,458.51
13.50 Applying priming coat :
41 13.50.3 With ready mixed red oxide zinc chromate primer of
approved brand and manufacture on steel galvanised
iron/ steel works 1.30 Sqm 65.58 85.25
42 13.61 Painting with synthetic enamel paint of approved brand
and manufacture of required colour to give an even
13.61.1 Two or more coats on new work 1.30 Sqm 151.69 197.20
1 15.42 Dismantling C.I. or asbestos rain water pipe with fittings
and clamps including stacking the material within 50
2 15.44 Dismantling G.I. pipes (external work) including
excavation and refilling trenches after taking out the
pipes, manually/ by mechanical means including stacking
of pipes within 50 metres lead as per direction of
Engineer-in-charge :
3 15.45 Dismantling C.I. pipes including excavation and refilling
trenches after taking out the pipes, manually/ by
mechanical means breaking lead caulked joints, melting
of lead and making into blocks including stacking of
pipes & lead at site within 50 metre lead as per direction
of Engineer-in-charge:
4 15.48 Taking out C.I. cover with frame from R.C.C. top slab of
manholes of various sizes including demolishing of
R.C.C. work manually/ by mechanical means and
stacking of useful materials near the site and disposal of
unserviceable materials within 50 metres lead as per
direction of Engineer-in-charge. 4.00 Each 678.57 2,714.28
5 15.51 Dismantling of road gully chamber of various sizes
including C.I. grating with frame including stacking of
useful materials near the site and disposal of
unserviceable materials within 50 metres lead including
refilling the excavated gap. 4.00 Each 932.86 3,731.46
6 14.82 Dismantling W.C. Pan of all sizes including disposal of
dismantled materials i/c malba all complete as per
directions of Engineer-in- Charge. 14.00 Each 130.48 1,826.71
7 15.53 Dismantling of C.I. sluice valve including stacking of
useful materials within a lead of 50 metres
15.53.1 Up to 150 mm diameter 5.00 Each 310.87 1,554.37
8 19.24 Dismantling of manhole including R.C.C. top slab, C.I.
cover with frame, including stacking of useful materials
near the site and disposal of unserviceable materials
within 50 m lead as per direction of Engineer- charge :
Digitally signed by JAYA
19.24.1 Rectangular manhole 90x80 cm and 45 cm deep 2.00 Each 2472.25 4,944.49
9 12.41 Providing and fixing on wall face unplasticised Rigid PVC
rain water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion, (i) Single
socketed pipes.
10 12.42 Providing and fixing on wall face unplasticised - PVC
moulded fittings/ accessories for unplasticised Rigid PVC
rain water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.1.2 a) Coupler
11 13.96 Painting (one or more coats) on rain water, soil, waste
and vent pipes and fittings with synthetic enamel paint of
approved brand and manufacture and required colour on
13.96.1 75 mm diameter pipes 15.00 Mtr 27.44 411.58
13.96.2 100 mm diameter pipes 15.00 Mtr 35.27 529.07
12 17.1 Providing and fixing water closet squatting pan (Indian
type W.C. pan ) with 100 mm sand cast Iron P or S trap,
10 litre low level white P.V.C. flushing cistern, including
flush pipe, with manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls
and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests 12.00 Each 6584.68 79,016.16
13 17.2 Providing and fixing white vitreous china pedestal type
water closet (European type W.C. pan) with seat and lid,
10 litre low level white P.V.C. flushing cistern, including
flush pipe, with manually controlled device (handle lever),
conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls
and floors wherever required.
17.2.1 W.C. pan with ISI marked white solid plastic seat and lid
14 17.7 Providing & fixing white vitreous china wash basin with
C.I. brackets painted white, 15mm C.P. brass pillar taps,
C.P. brass chain with rubber plug, 32mm C.P. brass
waste of standard pattern including cutting & making
good the walls wherever required.
17.7.4 a) Flat back wash Basin size 550x400 mm with single
15mm C.P. brass pillar tap. 2.00 Each 1828.46 3,656.92
15 17.23 Providing and fixing white vitreous china flat back or wall
corner type lipped front urinal basin of 430x260x350 mm
or 340x410x265 mm sizes respectively.
16 17.28 Providing and fixing flexible P.V.C. waste pipe for sink or
wash basin including PVC waste fittings complete.
17.28.2.1 a) 32mm dia (for wash basin) 2.00 Each 116.32 232.64
17.28.2.2 b) 40mm dia (for sink and urinal) 6.00 Each 116.32 697.93
17 MR Providing & fixing C.P. Brass health faucet for ablution
with 1 meter long PVC tube, hand shower, couplings, wall
hook and other accessories. 2.00 Each 1831.00 3,662.00
18 MR Providing and fixing CP Brass soap dish 109 mm wide,
125 mm high and 112 mm distance from wall of standard
shape with bracket and all fittings of the same material of
approved quality and colour.
19 17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm
breadth, weighing not less than 60 gms
Digitally signed by JAYA
20 Providing, fixing, jointing and testing in position of ISI
marked UV stabilized UPVC pipes for soil, waste, and
vent, Type-B as per IS : 13592 suitable for rubber ring
joints, including all neccessary specials and fittings
(confirming to IS:14735) i.e. bends, tees, junctions (with
or without doors), reducers, WC connectors, couplers,
expansion joints / bellows, cowels, clamps, rubber rings,
clean outs etc. fixing at wall/ ceiling/ floor level supported
by clamp & hangers etc. in concealed / inside duct /
under floor & basement ceiling / external work etc.
including chase cutting as required, excavation and back
filling in all kind of soils, suspended from floor under false
ceiling or embedding the pipes laid under floors / building
in 75 mm. alround 1:2:4 cement concrete (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal
size) including cost of shuttering for proper completion of
the work, breaking and making good the walls and floors
etc. after pipes have been duly laid and tested. The
rubber ring shall confirm to IS:5382.The Pipes will be
supported with threaded G I rods & U clamps with nuts,
washers etc on 50x50x5 mm slotted angle. The cost will
include all support arrangements. The work includes
commissioning of all pipes lines as per drawings and
specifications and as directed by engg-in-charge at site.
MR 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 15.00 Mtr 750.00 11,250.00
MR 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 20.00 Mtr 550.00 11,000.00
21 Providing & fixing UPVC Floor trap of self cleansing
design with stainless steel grating complete in all
MR Multi Floor Trap (5" Ht) with height raiser and branch
saddle strip of 50/75 mm outlet 2.00 Each 673.00 1,346.00
MR Plain Floor Trap (4" Ht) with 50 / 75 outlet and with height
MR P-Trap type Floor Trap 110 x 75 mm 10.00 Each 565.00 5,650.00
22 MR Extra for providing & fixing 125 mm dia C.P. grating in
place of C.I. grating over floor traps. 13.00 Each 597.00 7,761.00
23 MR Providing & fixing of SS Floor Cleanout, round or square
with rubber seal and flat round cover with screws and
other required fitting complete as required.
Providing and fixing 100 mm sand cast Iron grating for
gully trap. 51.81 207.25
25 17.31 Providing & fixing 600x450mm bevelled edge mirror of
superior glass (of approved quality) complete with 6mm
thick asbestos cement sheet ground fixed to wooden
cleats with C.P. brass screws and washers. 2.00 Each 1564.54 3,129.07
26 17.34 Providing and fixing toilet paper holder :
17.34.2 Vitreous china 2.00 Each 531.60 1,063.20
27 17.35 Providing & fixing soil, waste and vent pipes.
17.35.1.2 a) 100mm dia centrifugally cast iron S & S pipe. 5.00 Mtr 1148.87 5,744.35
17.35.2.2 b) 75mm dia centrifugally cast iron S & S pipe. 5.00 Mtr 1153.98 5,769.89
28 17.37 Providing & fixing M.S. holder bat clamps of approved
design to sand cast iron/centrifugally cast (Spun) iron S &
S pipe embeded in & including cement concrete blocks
10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4
graded stone aggregate 20mm nominal size). Including
cost of cutting holes & making good the walls etc.
29 17.38 Providing and fixing bend of required degree with access
door, insertion rubber washer 3mm thick, bolts and nuts
17.38.1.2 Sand cast iron S&S as per IS - 3989 2.00 Each 686.16 1,372.32
17.38.2.2 Sand cast iron S&S as per IS- 3989 2.00 Each 508.49 1,016.98
Digitally signed by JAYA
30 17.39 Providing and fixing plain cast iron S & S sanitary bend.
17.39.1.1 Sand cast iron S&S as per IS - 1729 2.00 Each 457.75 915.50
17.39.2.2 Sand cast iron S&S as per IS - 3989 2.00 Each 379.96 759.91
31 17.43 Providing and fixing centrifugaly cast iron single equal
plain junction of required degree.
32 17.56 Providing and fixing cast iron terminal guard.
33 17.57 Providing & fixing cast iron coller.
17.57.1.2 Sand cast iron S&S as per IS - 3989 2.00 Each 499.29 998.59
17.57.2.2 Sand cast iron S&S as per IS - 3989 2.00 Each 352.27 704.55
34 17.58 Providing lead caulked joints to sand cast
iron/centrifugally cast (spun) iron pipes & fitting of
35 17.60 Providing & fixing cast iron trap of self cleansing design
with or without ventarm complete, including cost of
cutting & making good the walls & floors.
36 17.75 Providing and fixing PTMT 15 mm Urinal spreader size
95x69x100 mm with 1/2" BSP thread and shapes,
weighing not less than 60 gms. 6.00 Each 104.31 625.83
37 17.76 Providing and fixing PTMT urinal cock of approved
quality and colour.
17.76.1 15 mm nominal bore, 80 mm long, 42 mm high and
30mm wide with BSP female threads weighing not less
38 18.8 Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass threaded
fittings, i/c fixing the pipe with clamps at 1.00 m spacing.
This includes jointing of pipes & fittings with one step
CPVC solvent cement and the cost of cutting chases and
making good the same including testing of joints
complete as per direction of Engineer in Charge.
18.8.1 15 mm nominal outer dia Pipes 65.00 Mtr 484.36 31,483.36
18.8.2 20 mm nominal outer dia Pipes 45.00 Mtr 523.08 23,538.82
18.8.3 25 mm nominal outer dia Pipes 35.00 Mtr 610.31 21,361.00
18.8.4 32 mm nominal outer dia Pipes 20.00 Mtr 719.34 14,386.78
39 18.16 Providing and fixing brass stop cock of approved quality.
40 18.17 Providing and fixing gun metal gate valve with wheel of
approved quality.
18.17.1 a) 25mm dia nominal bore 4.00 Each 605.60 2,422.38
18.17.2 b) 32mm dia nominal bore 4.00 Each 670.98 2,683.92
41 18.18 Providing and fixing ball valve (brass) of approved quality
complete. (High or low pressure with plastic floats).
18.18.3 a) 25mm. Nominal bore 4.00 Each 451.52 1,806.08
42 18.21 Providing and fixing 30 cm long unplasticised PVC
connection pipe with brass unions.
18.21.1.1 a) 15mm nominal bore 4.00 Each 82.71 330.82
43 18.21 Providing and fixing 45 cm long unplasticised PVC
connection pipe with brass unions.
18.21.2.1 a) 15mm nominal bore 4.00 Each 95.11 380.44
Digitally signed by JAYA
44 18.48 Providing and placing on terrace (at all floor levels)
polyethylene water storage tank of approved brand and
manufacture with cover and suitable locking arrangement
and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank.
45 18.49 Providing & fixing CP brass bib cock of approved quality
conforming to IS 8931
18.49.1 a) 15mm nominal bore 20.00 Each 493.12 9,862.33
46 18.51 Providing & fixing C.P. brass long body bib cock of
approved quality conforming to IS standards and
weighing not less than 690 gms.
18.51.1 a) 15mm nominal bore 1.00 Each 777.38 777.38
47 18.53 Providing and fixing C.P. brass angle valve for basin
mixer and geyser points of approved quality conforming
18.53.1 15mm nominal bore 2.00 Each 558.79 1,117.59
48 18.53A Providing and fixing C.P. Brass extension nipple (size
15mmx50mm) of approved make and quality as per
direction of Engineer-in-charge. 2.00 Each 72.78 145.56
49 18.75 Providing and fixing PTMT extension nipple for water
tank pipe, fittings of approved quality and colour.
18.75.3 25mm nominal bore, weighing not less than 62 gms 2.00 Each 110.29 220.58
50 18.76 Cutting holes up to 30x30 cm in walls including making
18.76.1 With common burnt clay F.P.S. (non modular) bricks
51 18.77 Cutting holes up to 15x15 cm in R.C.C. floors and roofs
for passing drain pipe etc. and repairing the hole after
insertion of drain pipe etc. with cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size), including finishing complete so as to
make it leak proof. 4.00 Each 439.80 1,759.18
52 18.78 Making chases up to 7.5x7.5 cm in walls including
making good and finishing with matching surface after
housing G.I. pipe etc. 25.00 Mtr 197.42 4,935.54
TOTAL AMOUNT 4,21,400.47 43,056.00
TOTAL AMOUNT 4,21,400.47 43,056.00
GRAND TOTAL AMOUNT 44,59,352.08 83,636.74
GRAND TOTAL AMOUNT 44,59,352.08 83,636.74
say in lacs 44.59 0.84
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV KONARK, PURI, ODISHA.
BILL OF QUANTITY FOR BOYS DORMITORY (G+1) 1 BLOCK FOR 192 STUDENTS
Sl. DSR- Description Qty Unit DSR Non- Amount On Amount On
No. 2023 Rate DSR DSR-2023 Non- DSR
(In Rs.) Rate (In Rs.) (In Rs.)
(i) Structural Repair & Retrofitting
1 26.28 Chipping of unsound/weak concrete material from slabs,
beams, columns etc. with manual Chisel and/ or by
standard power driven percussion type or of approved
make including tapering of all edges, making square
shoulders of cavities including cleaning the exposed
concrete surface and reinforcement with wire brushes
etc. and disposal of debris for all lead and lifts all
complete as per direction of Engineer-In-Charge
A 26.28.2 50mm average thickness 11.25 Sqm 249.43 2,806.07
B 26.28.3 25 mm average thickness 30.00 Sqm 123.33 3,699.83
2 26.29 Cleaning of reinforcement from rust from the reinforcing
bars to give it a total rust free steel surface by using
alkaline chemical rust remover of approved make with
paint brush and removing loose particles after 24 hours
of its application with wire brush and thoroughly washing
with water and allowing it to dry, all complete as per
direction of Engineer-In-Charge.
26.29.1 Bars upto 12 mm diameter 660.00 Mtr 8.03 5,297.99
3 26.37 Cleaning of exposed concrete surface of sticking material
including loose and foreign material by sand blasting with
coarse sand followed by and including cleaning with oil
free air blast as per direction of Engineer in charge.
4 26.38 Shotcreting R.C.C. columns, beams and slabs etc. in
layers with approved design mix concrete having the
specified minimum characteristic compressive strength
[with ordinary portland cement, coarse sand and graded
stone aggregate of 10 mm maximum size in proportion
as per design criteria] including the cost of centering and
shuttering at edges and corners etc. as directed by
Engineerin- Charge
Note: Rates shall include the providing necessary ground
wires etc. The levelling gauges, if used, shall be paid for
separately. Payment under this item shall be made only
after proper wet curing has been done and surface has
been satisfactorily evaluated by sounding/ tapping with a
blunt metal instrument.
A 26.38.1 25mm thick in Grade M 25 with cement content not less
than 330 kg per cum 30.00 Sqm 726.73 21,802.01
Expansion Joint Treatment
Digitally signed by JAYA
5 5.44 Providing and fixing of expansion joint system related
with floor location as per drawings and direction of
Engineer-In-Charge. The joints system will be of extruded
aluminum base members, self aligning / self centering
arrangement and support plates etc. as per ASTM B221-
02. The system shall be such that it provides floor to floor
/floor to wall expansion control system for various vertical
localtion in load application areas that accommodates
multi directional seismic movement without stress to it's
components. System shall consist of metal profiles with a
universal aluminum base member designed to
accommodate various project conditions and finish floor
treatments. The cover plate shall be designed of width
and thickness required to satisfy projects movement and
loading requirements and secured to base members by
utilizing manufacturer’s pre-engineered self- centering
arrangement that freely rotates / moves in all directions.
The Self - centering arrangement shall exhibit circular
sphere ends that lock and slide inside the corresponding
aluminum extrusion cavity to allow freedom of movement
and flexure in all directions including vertical
displacement. Provision of Moisture Barrier Membrane in
the Joint System to have watertight joint is mandatory
requirement all as per the manufactures design and as
approved by Engineer -in- Charge. (Material shall confirm
6 5.45 Providing and fixing of expansion joint system related
with wall joint (internal/ external) location as per drawings
and direction of Engineer-In- Charge. The joints shall be
of extruded aluminum base members, self aligning /
centering arrangement and support plates as per ASTM
B221- 02. The material shall be such that it provides an
Expansion Joints System suitable for vertical wall to wall/
wall to corner application, both new and existing
construction in office Buildings & complexes with no
slipping down tendency amongst the components of the
Joint System. The Joint System shall utilize light weight
aluminum profiles exhibiting minimal exposed aluminum
surfaces mechanically snap locking the multicellular to
facilitate movement. (Material shall confirm to ASTM
7 5.46 Providing and fixing of expansion joint system of
approved make and manufacture for various roof
locations as per approved drawings and direction of
Engineer-In-Charge. The joints shall be of extruded
aluminum base members with, self aligning and self
centering arragement support plates as per ASTM B221-
02. The system shall be such that it provides water tight
roof to roof /roof to corner joint cover expansion control
system that is capable of accommodating multidirectional
seismic movement without stress to its components.
System shall consist of metal profile that incorporates a
universal aluminum base member designed to
accommodate various project conditions and roof
treatments. The cover plate shall be designed of width
and thickness required to satisfy movement and loading
requirements and secured to base members by utilizing
manufacturer’s pre-engineered self-centering
arrangement that freely rotates / moves in all directions.
The Self centering arrangement shall exhibit circular
sphere ends that lock and slide inside the corresponding
aluminum extrusion cavity to allow freedom of movement
and flexure in all directions including vertical
displacement. The Joint System shall resists damage or
deterioration from the impact of falling ice, exposure to
UV, airborne contaminants and occasional foot traffic
from maintenance personnel. Provision of Moisture
Barrier Membrane in the Joint System to have water tight
joint is mandatory requirement. (Material shall confirm to
Digitally signed by JAYA
SUB TOTAL (for 1 block) 2,91,152.69 -
(ii) Repairs to Roof
8 14.91.1 Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer 3 mm thick
water proofing membrane, black finished reinforced with
non-woven polyester matt consisting of a coat of bitumen
primer for bitumen membrane @ 0.40 litre/sqm by the
same membrane manufacture of density at 25°C, 0.87-
0.89 kg/ litre and viscocity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane
Torch and sealing all joints etc, and preparing the surface
The vital physical and chemical parameters of the
membrane shall be as under : Joint strength in
longitudinal and transverse direction at 23°C as 650/
450N/ 5cm. Tear strength in longitudinal and transverse
direction as 300/250N. Softening point of membrane not
less than 150°C. Cold flexibility shall be upto -2°C when
tested in accordance with ASTM, D - 5147. The laying of
membrane shall be got done through the authorised
applicator of the manufacturer of membrane :
9 14.92 Extra for covering top of membrane with Geotextile, 120
gsm non woven, 100% polyester of thickness 1 to 1.25
mm bonded to the membrane with intermittent touch by
heating the membrane by Butane Torch as per
manufactures recommendation. 1,647.79 Sqm 86.50 1,42,533.34
10 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) 99.13 Cum 7825.16 7,75,707.90
SUB TOTAL (for 1 block) 18,17,612.19 -
GRAND TOTAL AMOUNT 21,08,764.88
GRAND TOTAL AMOUNT 21,08,764.88
say in lacs 21.09 -
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV KONARK, PURI, ODISHA.
BILL OF QUANTITY FOR BOYS DORMITORY (G+1) 1 BLOCK FOR 96 STUDENTS
Sl. DSR- Description Qty Unit DSR Rate Non-DSR Amount On Amount On
No. 2023 (In Rs.) Rate DSR-2023 Non- DSR
(i) Structural Repair & Retrofitting
1 26.28 Chipping of unsound/weak concrete material from
slabs, beams, columns etc. with manual Chisel and/ or
by standard power driven percussion type or of
approved make including tapering of all edges, making
square shoulders of cavities including cleaning the
exposed concrete surface and reinforcement with wire
brushes etc. and disposal of debris for all lead and lifts
all complete as per direction of Engineer-In-Charge
A 26.28.2 50 mm average thickness 3.30 Sqm 249.43 823.11
B 26.28.3 25 mm average thickness 6.00 Sqm 123.33 739.97
2 26.29 Cleaning of reinforcement from rust from the reinforcing
bars to give it a total rust free steel surface by using
alkaline chemical rust remover of approved make with
paint brush and removing loose particles after 24 hours
of its application with wire brush and thoroughly
washing with water and allowing it to dry, all complete
as per direction of Engineer-In-Charge.
26.29.1 Bars upto 12 mm diameter 148.80 Mtr 8.03 1,194.45
3 26.37 Cleaning of exposed concrete surface of sticking
material including loose and foreign material by sand
blasting with coarse sand followed by and including
cleaning with oil free air blast as per direction of
Engineer in charge. 4.20 Sqm 372.08 1,562.72
4 26.38 Shotcreting R.C.C. columns, beams and slabs etc. in
layers with approved design mix concrete having the
specified minimum characteristic compressive strength
[with ordinary portland cement, coarse sand and
graded stone aggregate of 10 mm maximum size in
proportion as per design criteria] including the cost of
centering and shuttering at edges and corners etc. as
directed by Engineerin- Charge
Note: Rates shall include the providing necessary
ground wires etc. The levelling gauges, if used, shall be
paid for separately. Payment under this item shall be
made only after proper wet curing has been done and
surface has been satisfactorily evaluated by sounding/
tapping with a blunt metal instrument.
A 26.38.1 25mm thick in Grade M 25 with cement content not less
than 330 kg per cum 6.00 Sqm 726.73 4,360.40
5 MR Re-Baring of MS bar 10 mm dia with Fisher Chemical
including drilling of hole, cleaning, and fixing of bar
complete as per direction of Engineer-in-Charge.
Expansion Joint Treatment
Digitally signed by JAYA
6 5.44 Providing and fixing of expansion joint system related
with floor location as per drawings and direction of
Engineer-In-Charge. The joints system will be of
extruded aluminum base members, self aligning / self
centering arrangement and support plates etc. as per
ASTM B221-02. The system shall be such that it
provides floor to floor /floor to wall expansion control
system for various vertical localtion in load application
areas that accommodates multi directional seismic
movement without stress to it's components. System
shall consist of metal profiles with a universal aluminum
base member designed to accommodate various
project conditions and finish floor treatments. The cover
plate shall be designed of width and thickness required
to satisfy projects movement and loading requirements
and secured to base members by utilizing
manufacturer’s pre-engineered self- centering
arrangement that freely rotates / moves in all directions.
The Self - centering arrangement shall exhibit circular
sphere ends that lock and slide inside the
corresponding aluminum extrusion cavity to allow
freedom of movement and flexure in all directions
including vertical displacement. Provision of Moisture
Barrier Membrane in the Joint System to have
watertight joint is mandatory requirement all as per the
manufactures design and as approved by Engineer -in-
Charge. (Material shall confirm to ASTM 6063).
7 5.45 Providing and fixing of expansion joint system related
with wall joint (internal/ external) location as per
drawings and direction of Engineer-In- Charge. The
joints shall be of extruded aluminum base members,
self aligning / centering arrangement and support plates
as per ASTM B221- 02. The material shall be such that
it provides an Expansion Joints System suitable for
vertical wall to wall/ wall to corner application, both new
and existing construction in office Buildings &
complexes with no slipping down tendency amongst the
components of the Joint System. The Joint System
shall utilize light weight aluminum profiles exhibiting
minimal exposed aluminum surfaces mechanically snap
locking the multicellular to facilitate movement.
(Material shall confirm to ASTM 6063).
8 5.46 Providing and fixing of expansion joint system of
approved make and manufacture for various roof
locations as per approved drawings and direction of
Engineer-In-Charge. The joints shall be of extruded
aluminum base members with, self aligning and self
centering arragement support plates as per ASTM
B221-02. The system shall be such that it provides
water tight roof to roof /roof to corner joint cover
expansion control system that is capable of
accommodating multidirectional seismic movement
without stress to its components. System shall consist
of metal profile that incorporates a universal aluminum
base member designed to accommodate various
project conditions and roof treatments. The cover plate
shall be designed of width and thickness required to
satisfy movement and loading requirements and
secured to base members by utilizing manufacturer’s
pre-engineered self-centering arrangement that freely
rotates / moves in all directions. The Self centering
arrangement shall exhibit circular sphere ends that lock
and slide inside the corresponding aluminum extrusion
cavity to allow freedom of movement and flexure in all
directions including vertical displacement. The Joint
System shall resists damage or deterioration from the
impact of falling ice, exposure to UV, airborne
contaminants and occasional foot traffic from
maintenance personnel. Provision of Moisture Barrier
Membrane in the Joint System to have water tight joint
is mandatory requirement. (Material shall confirm to
Digitally signed by JAYA
(ii) Repairs to Roof
9 14.91.1 Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer 3 mm thick
water proofing membrane, black finished reinforced
with non-woven polyester matt consisting of a coat of
bitumen primer for bitumen membrane @ 0.40 litre/sqm
by the same membrane manufacture of density at
25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over
the primer coat the layer of membrane shall be laid
using Butane Torch and sealing all joints etc, and
preparing the surface complete. The vital physical and
chemical parameters of the membrane shall be as
under : Joint strength in longitudinal and transverse
direction at 23°C as 650/ 450N/ 5cm. Tear strength in
longitudinal and transverse direction as 300/250N.
Softening point of membrane not less than 150°C. Cold
flexibility shall be upto -2°C when tested in accordance
with ASTM, D - 5147. The laying of membrane shall be
got done through the authorised applicator of the
manufacturer of membrane : 3 mm thick
10 14.92 Extra for covering top of membrane with Geotextile,
120 gsm non woven, 100% polyester of thickness 1 to
1.25 mm bonded to the membrane with intermittent
touch by heating the membrane by Butane Torch as
per manufactures recommendation.
11 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) 43.96 Cum 7825.16 3,43,993.94
SUB TOTAL 7,13,613.59 -
GRAND TOTAL AMOUNT 9,13,886.47 8,162.00
GRAND TOTAL AMOUNT 9,13,886.47 8,162.00
say in lacs 9.14 0.08
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV KONARK, PURI, ODISHA.
BILL OF QUANTITY FOR TYPE-II STAFF QUARTER (4 BLOCK) (G+1)
Sl. DSR- Description Qty Unit DSR Rate Non-DSR Amount On Amount On
No. 2023 (In Rs.) Rate DSR-2023 Non- DSR
(I) STRUCTURE REPAIR & RETROFITTINGS
1 26.29 Cleaning of reinforcement from rust from the
reinforcing bars to give it a total rust free steel
surface by using alkaline chemical rust remover of
approved make with paint brush and removing
loose particles after 24 hours of its application with
wire brush and thoroughly washing with water and
allowing it to dry, all complete as per direction of
Engineer-In-Charge.
26.29.1 Bars upto 12 mm diameter 108 Mtr 8.03 866.94
2 26.37 Cleaning of exposed concrete surface of sticking
material including loose and foreign material by
sand blasting with coarse sand followed by and
including cleaning with oil free air blast as per
direction of Engineer in charge. 13.8 Sqm 372.08 5,134.64
3 26.38 Shotcreting R.C.C. columns, beams and slabs etc.
in layers with approved design mix concrete having
the specified minimum characteristic compressive
strength [with ordinary portland cement, coarse
sand and graded stone aggregate of 10 mm
maximum size in proportion as per design criteria]
including the cost of centering and shuttering at
edges and corners etc. as directed by Engineerin-
Note: Rates shall include the providing necessary
ground wires etc. The levelling gauges, if used,
shall be paid for separately. Payment under this
item shall be made only after proper wet curing has
been done and surface has been satisfactorily
evaluated by sounding/ tapping with a blunt metal
26.38.1 25mm thick in Grade M 25 with cement content not
less than 330 kg per cum 18.24 Sqm 726.73 13,255.62
4 4.1 Providing and laying in position cement concrete of
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived
from natural sources : 4 graded stone aggregate
20 mm nominal size derived from natural ources)
TOTAL AMOUNT: (4-Block) 20,483.72 -
TOTAL AMOUNT: (4-Block) 20,483.72 -
(II) REPAIRS TO ROOF
Digitally signed by JAYA
5 14.91.1 Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer 3 mm
thick water proofing membrane, black finished
reinforced with non-woven polyester matt
consisting of a coat of bitumen primer for bitumen
membrane @ 0.40 litre/sqm by the same
membrane manufacture of density at 25°C, 0.87-
0.89 kg/ litre and viscocity 70-160 cps. Over the
primer coat the layer of membrane shall be laid
using Butane Torch and sealing all joints etc, and
preparing the surface complete.
The vital physical and chemical parameters of the
membrane shall be as under : Joint strength in
longitudinal and transverse direction at 23°C as
650/ 450N/ 5cm. Tear strength in longitudinal and
transverse direction as 300/250N. Softening point
of membrane not less than 150°C. Cold flexibility
shall be upto -2°C when tested in accordance with
ASTM, D - 5147. The laying of membrane shall be
got done through the authorised applicator of the
manufacturer of membrane :
6 14.92 Extra for covering top of membrane with
Geotextile, 120 gsm non woven, 100% polyester of
thickness 1 to 1.25 mm bonded to the membrane
with intermittent touch by heating the membrane by
Butane Torch as per manufactures
recommendation. 543.96 Sqm 86.50 47,052.38
TOTAL AMOUNT: (4-Block) 3,43,948.11 -
TOTAL AMOUNT: (4-Block) 3,43,948.11 -
GRAND TOTAL AMOUNT 3,64,431.83
GRAND TOTAL AMOUNT 3,64,431.83
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV KONARK, PURI, ODISHA.
BILL OF QUANTITY FOR TYPE-I STAFF QUARTER (2 BLOCK) (G+1)
Sl. DSR- Description Qty Unit DSR Rate Non-DSR Amount On Amount On
No. 2023 (In Rs.) Rate DSR-2023 Non- DSR
(I) STRUCTURE REPAIR & RETROFITTINGS
1 26.28 Chipping of unsound/weak concrete material from slabs,
beams, columns etc. with manual Chisel and/ or by
standard power driven percussion type or of approved
make including tapering of all edges, making square
shoulders of cavities including cleaning the exposed
concrete surface and reinforcement with wire brushes
etc. and disposal of debris for all lead and lifts all
complete as per direction of Engineer-In-Charge
26.28.3 25 mm average thickness 9.18 SQM 123.33 1,132.15
2 26.29 Cleaning of reinforcement from rust from the reinforcing
bars to give it a total rust free steel surface by using
alkaline chemical rust remover of approved make with
paint brush and removing loose particles after 24 hours
of its application with wire brush and thoroughly washing
with water and allowing it to dry, all complete as per
direction of Engineer-In-Charge.
26.29.1 Bars upto 12 mm diameter 145.98 Mtr 8.03 1,171.82
3 26.37 Cleaning of exposed concrete surface of sticking material
including loose and foreign material by sand blasting with
coarse sand followed by and including cleaning with oil
free air blast as per direction of Engineer in charge.
4 26.38 Shotcreting R.C.C. columns, beams and slabs etc. in
layers with approved design mix concrete having the
specified minimum characteristic compressive strength
[with ordinary portland cement, coarse sand and graded
stone aggregate of 10 mm maximum size in proportion as
per design criteria] including the cost of centering and
shuttering at edges and corners etc. as directed by
Engineerin- Charge -
Note: Rates shall include the providing necessary ground
wires etc. The levelling gauges, if used, shall be paid for
separately. Payment under this item shall be made only
after proper wet curing has been done and surface has
been satisfactorily evaluated by sounding/ tapping with a
blunt metal instrument. -
26.38.1 25mm thick in Grade M 25 with cement content not less
than 330 kg per cum 9.16 Sqm 726.73 6,656.88
TOTAL AMOUNT: (2-Block) 12,376.50 -
TOTAL AMOUNT: (2-Block) 12,376.50 -
(II) REPAIRS TO ROOF
5 14.91.1 Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer 3 mm thick
water proofing membrane, black finished reinforced with
non-woven polyester matt consisting of a coat of bitumen
primer for bitumen membrane @ 0.40 litre/sqm by the
same membrane manufacture of density at 25°C, 0.87-
0.89 kg/ litre and viscocity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane
Torch and sealing all joints etc, and preparing the surface
The vital physical and chemical parameters of the
membrane shall be as under : Joint strength in
longitudinal and transverse direction at 23°C as 650/
450N/ 5cm. Tear strength in longitudinal and transverse
direction as 300/250N. Softening point of membrane not
less than 150°C. Cold flexibility shall be upto -2°C when
tested in accordance with ASTM, D - 5147. The laying of
membrane shall be got done through the authorised
applicator of the manufacturer of membrane :
Digitally signed by JAYA
6 14.92 Extra for covering top of membrane with Geotextile, 120
gsm non woven, 100% polyester of thickness 1 to 1.25
mm bonded to the membrane with intermittent touch by
heating the membrane by Butane Torch as per
manufactures recommendation. 299.44 Sqm 86.50 25,901.47
TOTAL AMOUNT: (2-Block) 1,89,599.11 -
TOTAL AMOUNT: (2-Block) 1,89,599.11 -
GRAND TOTAL AMOUNT 2,01,975.61
GRAND TOTAL AMOUNT 2,01,975.61
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV KONARK, PURI, ODISHA.
BILL OF QUANTITY FOR TYPE - 4 STAFF QUARTER (1 BLOCK)
Sl. DSR- Description Qty Unit DSR Rate Non-DSR Amount On Amount On
No. 2023 (In Rs.) Rate DSR-2023 Non- DSR
(ii) Repairs to Roof
1 14.91.1 Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer 3 mm thick
water proofing membrane, black finished reinforced with
non-woven polyester matt consisting of a coat of bitumen
primer for bitumen membrane @ 0.40 litre/sqm by the
same membrane manufacture of density at 25°C, 0.87-
0.89 kg/ litre and viscocity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane
Torch and sealing all joints etc, and preparing the
surface complete.
The vital physical and chemical parameters of the
membrane shall be as under : Joint strength in
longitudinal and transverse direction at 23°C as 650/
450N/ 5cm. Tear strength in longitudinal and transverse
direction as 300/250N. Softening point of membrane not
less than 150°C. Cold flexibility shall be upto -2°C when
tested in accordance with ASTM, D - 5147. The laying of
membrane shall be got done through the authorised
applicator of the manufacturer of membrane :
2 14.92 Extra for covering top of membrane with Geotextile, 120
gsm non woven, 100% polyester of thickness 1 to 1.25
mm bonded to the membrane with intermittent touch by
heating the membrane by Butane Torch as per
manufactures recommendation. 94.50 Sqm 86.50 8,174.22
3 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) 7.09 Cum 7825.16 55,480.37
Sub TOTAL: 1,15,233.10 -
Say (In Lacs): 1.15 -
Digitally signed by JAYA
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
GCC WITH AMENDMENT-16.pdf
Tender Document
BOQ.pdf
Tender Document
Technical Specification.pdf
Tender Document
Approved Makes.pdf
Tender Document
Technical Circular_31.pdf
Tender Document
Milestone.pdf
Tender Document
Scope of Work.pdf
Tender Document
Rev SCC.pdf
Tender Document
corrigendum-4684-Corrigendum01.pdf
pdf • 0.09 MB
addendum-4fed89f7440c-Addendum001.pdf
pdf • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .