| 1 | L1₹6.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹7.7 L+₹98,600 (14.6%)Rejected-Finance UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹9.2 L+₹2.5 L (36.3%)Rejected-Finance GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L3 | Rejected-Finance Being Not Lowest | |
| 4 | Rejected-Technical 133 SADAK DUDHLI SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | - | Rejected-Technical Not enlisted in appropriate category b i | |
| 5 | Rejected-Technical | - | Rejected-Technical documents not submitted as per un enlisted contractor criteria as per NIT |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
17 Sept 2022, 6:00 pmClosed
AGE I Lansdowne
REPAIR/MAINT OF BLDG SECURITY LIGHT AND COOLING APPLIANCES AND CONNECTED WORK UNDER AGE (I) LANSDOWNE
REPAIR/MAINT OF BLDG SECURITY LIGHT AND COOLING APPLIANCES AND CONNECTED WORK UNDER AGE (I) LANSDOWNE
2022_MES_546749_1
8773/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
Class E Cat b i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹19,000
11 Oct 2022
22 Aug 2022
19 Sept 2022
22 Aug 2022
17 Sept 2022
5 Sept 2022
Amount
Taking down carefully point wiring copper/ aluminium (light, fan, socket, power) complete including fixtures & fittings such as switches, ceiling roses , pendants, regulators , sockets, light fittings etc and removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls, floors etc complete all as specified & directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including surface rigid PVC conduit," medium grade" (ISI marked), not less than 20 mm dia on wall/ceiling or above false ceiling with fittings (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with hylem sheet cover complete all as specified and directed.
All as per item No-02 here in above but in existing conduit complete all as specified & directed.
S&F switch piano 230 volts AC flush type, single pole, one way 6 Amps ISI Marked complete all as specified and directed. Make : Anchor/ Cona / Havells
S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body ISI marked all as specified and directed Make : Anchor/ Cona / Havells
Supply and fix new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including making necessary electric connection with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade complete all as specified and as directed. (i) The firm has to given warranty of street light fittings including driver minimum for 02 years for any defect developed during the period. (ii) The contractor Shall submit the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No
Disconnecting, dismantling and taking out the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, checking serviceability of wiring & parts, painting the bottom with one coat of black synthetic enameled paint, brazing, reassembling and testing of the AC complete all as specified and directed
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed. NOTE :- (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item
Disconnecting and taking out defective / nonfunctional air filter and Supply & fixing Air filter nylon type suitable for window type/Split A/C complete all as specified and directed. Make – Athlete / John Flower
Disconnecting and taking out existing defective / unserviceable remote control assembly with PCB of any description and in any position of any type of split AC & Supplying & fixing new remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed . (Make : Carrier/Hitachi/LG )
Taking out defective sealed unit compressor of window type AC of capacity 1.5 TR of any make and S&F new compressor of original make in the existing AC, including welding, brazing of gas pipe line, vacuum pressure and testing with charging of Refrigerant Gas and testing & commissioning of AC complete all as specified and directed.
All as per item No 11 here in above but compressor of 2TR capacity AC of any make complete all as specified and directed. Note for item No. 10 & 11)Refrigerant Gas required for charging of compressor shall be measured separately under respective item of this Schedule.
Supply & charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed.
Disconnecting, dismantling and taking out the non-functional voltage stabilizer for General servicing and minor repairs AC 230 volts Single Phase 3 to 5 KVA cap. of any make by checking, tightening of electrical connection, replacement of all missing/worn out screws, indicating lamps, checking of electronic circuits to make it functional including replacement of minor defective parts complete all as specified and directed. NOTE :-The replacement of defective / nonfunctional parts shall be measured & paid for separately under appropriate item of Sch ‘A’
Supply & fixing transformer copper wound of voltage stabilizer AC, Single Phase, 230 volts of capacity 5 KVA of approved make complete all as specified and directed.
All as per Item No 15 here in above but of capacity 4 KVA complete all as specified and directed.
Disconnecting the Refrigerator and strip opening for the checking of the defective parts and fixing of the new parts for proper functioning, re-assembling, refixing and re-connecting the Refrigertaor back to its original location and testing complete all as specified and directed
Supply and fixing in replacement hermetically sealed or rotary compressor suitable for Refrigerator of capacity 165 Ltrs complete all as specified and directed. Make :- Kirloskar / Complent / Tecumseh.
Supply and fixing in replacement hermetically sealed or rotary compressor suitable for Refrigerator/Deep freezer of capacity 310 Ltrs complete all as specified and directed. Make :- Kirloskar / Complent / Tecumseh.
Supply, charge, testing and commissioning R-134(a) gas for Refrigerator of capacity 165 Ltrs / 286 Ltrs / 310 Ltrs of any make complete all as specified and directed.
M&L for replacement of sealed type compressor unit company repaired suitable for 60/120 ltr cooling capacity water cooler fixing in position ,testing of leakage and making necessary connection and testing complete all as specified and as directed.
All as per item No. 21 here in before but 40/80 Ltr cap complete all as specified and directed.
M&L for replacement of new condensing fan motor cap 1/10 HP for water cooler complete all as specified and directed
M&L for replacement of new condensing fan motor cap 1/32 HP for water cooler complete all as specified and directed
All as per Srl item No. 25 here-in-above but 500 Ltr capacity complete all as specified and directed
S & F in replacement solar plate collector (FPC) suitable for 1000 Ltr solar water heater system complete all as specified and directed. Make :- TATA BP Solar
S & F in replacement heat exchanger kit suitable for existing solar water heater system complete all as specified and directed
M/S Garhwal Enterprises
PIONEER REFRIGERATION AND ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .