Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.7 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹29.2 L+₹1.5 L (5.37%)Rejected-AOC R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹34.8 L+₹7.1 L (25.8%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹36.0 L+₹8.3 L (30.1%)Rejected-AOC | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹40.7 L+₹13.1 L (47.2%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Jan 2023, 6:00 pmClosed
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
REPAIR MAINTENANCE TO MISC EM EQUIPMENTS, SECURITY LIGHTS, FITTINGS AND FIXTURES INCLUDING WIRING AND CIRCUIT BREAKER AT DIGIANA, RAMGARH AND BD BARI MIL STN UNDER GE KALUCHAK
2023_MES_572541_1
GE/KC/NIT-60/2022-23
Open Tender
Civil Works
Item Rate
270 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹98,000
Yes
25 Mar 2023
2 Jan 2023
6 Feb 2023
2 Jan 2023
30 Jan 2023
16 Jan 2023
2 Jan 2023 - 9 Jan 2023
Amount
Servicing of DG Set 100 KVA of any make, checking entire system as per manufacturer's catalogue such as checking all parts for serviceablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy, air filter, flexible hose pipe, radiator coolent, distill water, tightening the base bolt and nuts and mounting bolts and nuts etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump, cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level, cleaning of battery terminals with warm water, checking the radiator and radiator hose and arresting small leaks, checking the fuel pump timing and adjusting if required and including testing to DG Set to entire satisfaction of Engr-in Charge, complete all as specified & directed. Make : Kirloskar/ Crompton/ Cummins
Notes :- (i) Spare parts/ Engine oil/ Check kit/ filter shall be measured and paid for saperately under respective items of BOQ as 'Supply only'. (ii) Minimum 6 months gap/ 200 Hrs of run whichever is earlier shall be considered for next service. (iii) Repair guarantee for replaced parts/ servicing of DG Set shall be for six month/ 200 Hrs run from the date of service whichever is earlier. (iv) Cost of small spares required for maint of DG set shall be deemed to be included in the unit rate quoted by the contractor (v) Service Engineer must be skilled and must have knowledge of maintenance of DG sets and attending minor and major fault when it arise.
All as per Srl item No.01 above but DG set of capacity 62.5 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 50 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 40 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 30 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 10 KVA.
Supply only Air filter element (OEM manufactured) suitable for 10 KVA DG set, complete all as specified & directed.
Supply only Air filter element (OEM manufactured) suitable for 30 KVA DG set, complete all as specified & directed.
Supply only Air filter element (OEM manufactured) suitable for 40 KVA DG set, complete all as specified & directed.
Supply only Air filter element (OEM manufactured) suitable for 62.5 KVA DG set, complete all as specified & directed.
Supply only Air filter element (OEM manufactured) suitable for 100 KVA DG set, complete all as specified & directed.
Supply only Diesel filter (OEM manufactured) capacity 1/2 litre with 'O' ring (Primary & Secondary) suitable for 10 KVA DG set, complete all as specified & directed.
Supply only Diesel filter (OEM manufactured) capacity 1/2 litre with 'O' ring (Primary & Secondary) suitable for 30 KVA DG set, complete all as specified & directed.
Supply only Diesel filter (OEM manufactured) capacity 1 litre with 'O' ring (Primary & Secondary) suitable for 40 KVA DG set, complete all as specified & directed.
Supply only Diesel filter (OEM manufactured) capacity 1 litre with 'O' ring (Primary & Secondary) suitable for 50 KVA DG set, complete all as specified & directed.
Supply only Diesel filter (OEM manufactured) capacity 1 litre with 'O' ring (Primary & Secondary) suitable for 62.5 KVA DG set, complete all as specified & directed.
Supply only Diesel filter (OEM manufactured) capacity 1 litre with 'O' ring (Primary & Secondary) suitable for 100 KVA DG set, complete all as specified & directed.
Supply only Water Separator (OEM manufactured) capacity 1/2 litre with 'O' ring suitable for 10/15 KVA DG set, complete all as specified & directed.
Supply only Water Separator (OEM manufactured) capacity 1/2 litre with 'O' ring suitable for 30/35 KVA DG set, complete all as specified & directed.
Supply only Water Separator (OEM manufactured) capacity 1 litre with 'O' ring suitable for 40/45 KVA DG set, complete all as specified & directed.
Supply only Water Separator (OEM manufactured) capacity 1 litre with 'O' ring suitable for 50 KVA DG set, complete all as specified & directed.
Supply only Water Separator (OEM manufactured) capacity 1 litre with 'O' ring (Pre & micro) suitable for 62.5 KVA DG set, complete all as specified & directed.
Supply only Oil filter (OEM manufactured) capacity 1/2 litre with 'O' ring suitable for 10/15 KVA DG set, complete all as specified & directed.
Supply only Oil filter (OEM manufactured) capacity 1/2 litre with 'O' ring suitable for 30/35 KVA DG set, complete all as specified & directed.
Supply only Oil filter (OEM manufactured) capacity 1 litre with 'O' ring suitable for 40 KVA DG set, complete all as specified & directed.
Supply only Oil filter (OEM manufactured) capacity 1 litre with 'O' ring suitable for 50 KVA DG set, complete all as specified & directed.
Supply only Oil filter (OEM manufactured) capacity 1 litre with 'O' ring suitable for 62.5 KVA DG set, complete all as specified & directed.
Supply only Oil filter (OEM manufactured) capacity 1 litre with 'O' ring suitable for 100 KVA DG set, complete all as specified & directed.
Supply only Rocker cover / sump packing kit (OEM manufactured) suitable for 30/35 KVA DG set, complete all as specified & directed.
Supply only Rocker cover / sump packing kit (OEM manufactured) suitable for 30/35 KVA DG set, complete all as specified & directed.
Supply only Rocker cover / sump packing kit (OEM manufactured) suitable for 50 KVA DG set, complete all as specified & directed.
Supply only Rocker cover / sump packing kit (OEM manufactured) suitable for 62.5 KVA DG set, complete all as specified & directed.
Supply only Rocker cover / sump packing kit (OEM manufactured) suitable for 100 KVA DG set, complete all as specified & directed.
Supply only Fuel line (OEM manufactured) complete with clamps suitable for 10/15 KVA DG set, complete all as specified & directed.
Supply only Fuel line (OEM manufactured) complete with clamps suitable for 30/35 KVA DG set, complete all as specified & directed.
Supply only Fuel line (OEM manufactured) complete with clamps suitable for 40/45 KVA DG set, complete all as specified & directed.
Supply only Fuel line (OEM manufactured) complete with clamps suitable for 50 KVA DG set, complete all as specified & directed.
Supply only Fuel line (OEM manufactured) complete with clamps suitable for 62.5 KVA DG set, complete all as specified & directed.
Supply only Fuel line (OEM manufactured) complete with clamps suitable for 100 KVA DG set, complete all as specified & directed.
Supply only Low lube oil pressure sensor (OEM manufactured) complete suitable for 15/ 20/ 25/ 30/ 40/50/ 62.5 KVA DG set, complete all as specified & directed.
Supply only Low lube oil pressure sensor (OEM manufactured) complete suitable for 100 KVA DG set, complete all as specified & directed.
Supply only Water hose pipe kit (OEM manufactured) complete with clamps, nuts & bolts suitable for 30/ 40/ 50/ 62.5 KVA DG set, complete all as specified & directed.
Supply only engine oil 15W/ 40, complete all as specified & directed.
Supply only water coolent suitable for DG set, complete all as specified & directed.
Supply only distilled water for filling in batteries, complete all as specified & directed.
Taking down existing worn out water pump fan belt (V Belt) from the following capacity of DG set installed at various installations and supply and fixing with new fan belt of same specifications, complete & specified and as directed :-
15 KVA to 30 KVA
40 KVA to 62.5 KVA
100 KVA to 125 KVA
Taking down/ Dismantling of unserviceable self starter 12 volts from engine of DG Set , opening of stator and armature for repairing by replacing the worn out carbon brushes, brush holder, bearings, ignition / solenoid coil, replacement of burnt armature, rewinding of field coils, replacement of pinion gears, bushing etc, complete servicing , varnishing of stator /armature and refixing after repair, testing / commissioning complete for DG Set of any capacity, complete all as specified & directed.
Battery terminals (positive and negative) brass heavy duty complete suitable for fixing on battery poles with bolts, nuts and washers complete including taking down old unserviceable battery terminals, complete all as specified & directed.
Supply, installation, testing and commissioning of maintenance free lead acid battery, 12V, 180 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed.
Supply, installation, testing and commissioning of maintenance free lead acid battery, 12V, 150 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed.
Supply, installation, testing and commissioning of maintenance free lead acid battery, 12V, 90 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed.
Servicing and maintenance of existing Chemical Dosing system suitable to inject solution upto 25 LPH comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit of make satya sai including replacement of unserviceable part at site chemical dosing system & changing of Teflon gland packing and cleaning of NRV set, checking the complete system complete all as specified & directed. Make of Plant : Sathya Sai Services . Notes :1. Servicing shall be carried out by the company rep and the rate for this shall deemed to be included in item. 2. Spares shall be of original manufacturer only. 3. Spares shall be paid and measured and seperately under as 'Supply only' under respective items.
Supply only PVC adopter for suction and delivery without NRV, complete all as specified & directed.
Supply only PVC strainer washer type heavy duty or Y type strainer for suction, complete all as specified & directed.
Supply only Teflon gland square type 3 mm, complete all as specified & directed.
Supply only Chemical Oil seal with cap, complete all as specified & directed.
Taking down brunt unserviceable automatic voltage regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 20 to 45 KVA DG Set including connecting all electrical connections, testing voltage after starting engine and setting properly complete all as specified & directed.
Taking down brunt unserviceable automatic voltage regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 62.5 to 100 KVA DG Set including connecting all electrical connections, testing voltage after starting engine and setting properly complete all as specified & directed.
Disconnecting, removing and dismantling radiator assembly from the following capacity DG sets and descaling the radiator throughly with CTC solution/ any other chemical solvent agent as approved by the Engineer-in-charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., re-installing and commissioning complete all as specified & directed :-
20 to 30 KVA
40 to 62.5 KVA
100 to 125 KVA
Taking down existing unserviceable water pump assembly of following capacity DG sets installed at various installation and replaced with new water pump assembly (OEM Manufactured), complete all as specified & directed :-
20 to 40 KVA
Disconnecting electrical and mechanical connections of the following capacity alternator, 415 volts 50 HZ removing from foundations/ diesel engine coupling, transporting to private work shop, dismantling the alternator in parts and carrying out servicing, varnishing and applying the bactol on the excitor coils/ winding with super varnish, heating the windings at appropriate tempeature to achieve required insulation resistance without damaging the other parts, replacement of driving and non driving end bearings, cleaning, greasing, reassembling/ installing/ connecting and testing with megger for insulation resistance etc., complete all as specified & directed. Notes :- (i) Rewinding of alternator, repairing of main shaft replacement of unserviceable bearings, replacement of AVR will be measured and paid separately under respective items. (ii) Minor parts required to make the alternator serviceable are deemed to be included in the unit rate. Make of DG Set : Kirloskar / Ruston / CG / Sudhir/ Ashok Layland
Taking down existing defective injector and fuel injection pump (FIP) for the following capacity DG set installed at various installation and replacement of worn out spares like delivery valves, nozzles, bearings, fly weight, packing kit, and copper washer kit, injector element, kit injector, retainer injector cup, fixing tappit cover packing set and recalibration of FIP and refixing in same position and testing of full load checking of pressure and adjustment by dial gauge complete all as specified and as directed :-
Dismantling of unserviceable battery charging dynamo of 12 Volts from DG set of capacity 15 KVA to 62.5 KVA, repair and servicing of dynomo including replacement of bushes, bearings, carbon brushes, rectifires, rewinding of field magnet coil / rotor armeture coils and any other minor parts required for smooth functioning and refixing on DG set after repair/service including testing after commissioning, complete all as specified & directed.
Dismantling of old unserviceable battery charging dynomo of rating 12 volts and supply and fixing new battery charging dynomo of same specifications as per existing model suitable for fixing on DG set having capacity 100 KVA, 1500 RPM including testing after complete installation, complete all as specified & diirected.
Electronic type Starting Switch suitable for 15KVA to 62.5 KVA DG set including taking down old unserviceable switch, complete all as specified & directed.
Feed pump (OEM manufactured) suitable for 7.5 KVA to 63 KVA DG set including taking down old unserviceable pump, complete all as specified & directed.
Taking down the existing defective DC ammeter and volt meter from the panel and replaced with new combined DC ammeter and volt meter including necessary wiring & wiring material, complete all as specified & directed .
Engine safety unit (ESU) alongwith meter for pressure, fuel, RPM etc. with all electrical instruments and accessories including testing and taking down old unserviceable ESU, complete all as specified & directed.
On load change over switch in sheet metal enclosure, 100 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed.
On load change over switch in sheet metal enclosure, 160 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed.
On load change over switch in sheet metal enclosure, 200 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed.
Servicing and cleaning of oil cooled servo voltage stabilizer of capacity 30 KVA to 50 KVA, 3 phase by transporting to workshop, carefully lifting of core from the tank by opening cover, cleaning of tank, removing of sediments, cleaning of coils/ electric connections, filtration of transformer oil, fixing the core back in the tank, making electrical connections by replacing the consumble spares such as gaskets, rubber oil seals complete etc but other spares as listed here-in-after shall be replaced and cost of spare parts 'Supply only' shall be measured and paid for separately under relevant item, transporting back to work site and reconnectiong with electrical connection, complete all as specified & directed by Eng-in-charge. Note : The parts required to be replaced will be measured and paid separately as 'Supply only' against relevant item of schedule. However labour element involved in replacement are included in quoted rate against this item.
Supply only the following spare parts/ components to be incorporated against Serial Item No 68 here-in-before :-
Copper dimmer stat 40A.
Servo motor 3 KG with RC network
Carbon brush 40A with holder
Controlling circuit
Aluminium arm set 32A
Pipe bush
Current collector plate copper
Indicating lamps
Toggle switch
Voltmeter 0-500V
Input output connection busbar with bakelite
Fresh transformer oil for top up
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down carefully unserviceable main switche fuse unit, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 75 above but for one 3/5 pin 5 Amps socket outlet on independent board.
All as per Srl item No. 75 here-in-before but for one 3/5 pin 5 Amps socket outlet on same board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Socket outlet, 5 pin type, 5 Amp, flush type, 240 Volt, complete all as specified & directed.
Bell push flush type, one way 5 Amps single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan, complete all as specified & directed.
Electronic bell, Ding Dong AC. 230 volts, single pole, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
Fully diffused recessed mounted luminaire 2'x2' LED 36W suitable for POP/ gypsum false ceiling complete with hosing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to light fitting, complete all as specified & directed.
Sub main wiring using uniform coding of wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4.00 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Factory made epoxy powder coated distribution board vertical type, VTPN, 4 ways with metal double door (IP-43 protection) confirming to IS : 8623, fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar, cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one MCCB 63/100/160 Amp 4P as incomer and MCBs SP/TP as outgoing, complete all as specified & directed.
Factory made epoxy powder coated distribution board, SPN, 4 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
Factory made epoxy powder coated distribution board, SPN, 8 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
Factory made epoxy powder coated distribution board, SPN, 12 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
MCCB of capacity 63 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, ATM (Thermal magnetic release), adjustable overload 80-100%, adjustable short circuit 5-10 In, complete all as specified & directed.
MCB, single pole & neutral, 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way including taking down old unserviceable switch , complete all as specified & directed.
Switch piano flush type 15 Amps 240 Volts single pole one way including taking down old unserviceable switch, complete all as specified & directed.
Socket outlet, 5 pin type, 5 Amp, flush type, 240 Volt including taking down old unserviceable socket, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal including taking down old unserviceable switch socket combination, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal including taking down old unserviceable switch socket combination, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including taking down old unserviceable lamp holder, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan including taking down old unserviceable fan regulator, complete all as specified & directed.
Bell push flush type, one way 5 Amps single pole one way including taking down old unserviceable bell push, complete all as specified & directed.
Electronic bell, Ding Dong AC. 230 volts, single pole including taking down old unserviceable bell, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including taking down old unserviceable tube light fitting, complete all as specified & directed.
Fully diffused recessed mounted luminaire 2'x2' LED 36W suitable for POP/ gypsum false ceiling complete with hosing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to light fitting including taking down old unserviceable recessed mounted luminaire, complete all as specified & directed.
MCB, single pole & neutral, 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
FRLS PVC insulated unsheathed multistranded copper conductor of 1.5 sqmm (nominal area), 1100 Volts conforming to IS: 694 including taking down old unserviceable conductor, complete all as specified & directed.
FRLS PVC insulated unsheathed multistranded copper conductor of 2.5 sqmm (nominal area), 1100 Volts conforming to IS: 694 including taking down old unserviceable conductor, complete all as specified & directed.
FRLS PVC insulated unsheathed multistranded copper conductor of 4.0sqmm (nominal area), 1100 Volts conforming to IS: 694 including taking down old unserviceable conductor, complete all as specified & directed.
FRLS PVC insulated unsheathed multistranded copper conductor of 6.0 sqmm (nominal area), 1100 Volts conforming to IS: 694 including taking down old unserviceable conductor, complete all as specified & directed.
Plug top, 3 pin, 15 Amps, 240 volts, 50 Hz AC supply including taking down old unserviceable plug top, complete all as specified & directed.
Capacitor 2.5/3.5 Mfd, 230 Volts suitable for ceiling/exhaust fan including taking down old unserviceable capacitor, complete all as specified & directed.
PVC casing caping of 20mm wide, 2.0 mm thick (ISI marked), interlock type, fixed on wall/roof with all fittings such as tees, bends, elbows, etc and fixing accessories including taking down old unserviceable casing caping, complete all as specified & directed.
PVC casing caping of 25mm wide, 2.0 mm thick (ISI marked), interlock type, fixed on wall/roof with all fittings such as tees, bends, elbows, etc and fixing accessories including taking down old unserviceable casing caping, complete all as specified & directed.
3mm thick laminated bakelite sheet, cutting to 9"x11" size, drilling holes for mounting switch/ socket/ regulators etc, fixed with screws and GI covers with cup head washers including taking down old unserviceable laminated sheet, complete all as specified & directed.
3mm thick laminated bakelite sheet, cutting to 5"x7" size, drilling holes for mounting switch/ socket/ regulators etc, fixed with screws and GI covers with cup head washers including taking down old unserviceable laminated sheet, complete all as specified & directed.
3mm thick laminated bakelite sheet, cutting to 7"x9" size, drilling holes for mounting switch/ socket/ regulators etc, fixed with screws and GI covers with cup head washers including taking down old unserviceable laminated sheet, complete all as specified & directed.
Tamper proof with inbuilt intelligence electronic energy meter, single phase, two wire direct connected meter with parameter (voltage P-n, PF, frequency current line KW demand, LCD display, optical port class 1.0s), 240 volts 10-60 Amps, complete with meter box single phase with locking arrangements molded in UV stabilised transperant/ flame retardant high grade engineering plastic with unique arrangements for plifer proof interlocking with hinge type box with connection of suitable size wire including seal and sealing wire including taking down old unserviceable energy meter and depositing in MES store yard, complete all as specified & directed. Notes : (i) MES No to be marked on the meter with black paint as directed. All details ie Bldg No, Qtr No, Initial Reading, SL No of new meter etc as per specified format are to be submitted by the contractor.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Intergral LED security light luminaire 90W LED, 230 volts made up of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, luminaire, mounted on & including GI bracket made out of 50mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting of any type/size, complete all as specified & directed.
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, luminaire, mounted on & including GI bracket made out of 50mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting of any type/size, complete all as specified & directed.
Junction box, hot pressed moulded SMC of inside dimension 270x225x135mm and outside dimension 320x260x165mm with single MCB SP 10 A, 10KA, 230V, locking arrangements consisting of necessary suitable arrangements for incoming & out going cables, cable glands & having aluminium bus bar of 60 Amps capacity for TPN on necessary base plate, porcelain base including necessary flat iron clamps with nuts, bolts & washers and taking down old unserviceable junction box of any type, complete all as specified and directed.
Steel tubular swaged poles in vertical position swaged type 410-SP-31, 9 Mtr long, ISI marked, in one piece, complete with cast iron base plate, finial taper plug, bolts, nuts washers and screws as required, drilling of holes for continious earth wire as specified duly painted with two coats of aluminium paint over a coat of red oxide primer above ground level including painting throughout internally & below GL (externally) with two coats of bituminous paint, numbering of poles with cut stencil lettering in size 6mm thick, 50mm high and white and black strips of size 30cm width each with synthetic elamel paint upto 1.5m above coping etc including dismantling of old unserviceable steel tubular pole, complete all as specified and directed. Note:- 1. Earth work and PCC will be measured and paid for seperately under appropriate items.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Excavation in trenches n.exc 1.5 mtr wide exc 1.5 mtr in deep but not exceeding 3.0 mtr deep and getting out for foundation of poles etc. in any type of soil, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included the cost of excavation.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Cutting/ boring of road/hard standing to a size of 30cm in width and not exc 60 cm in depth for laying of protection pipe / water line/ cable including returning, filling in, spreading, romoval of surplus soil and providing 100mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate on top, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included the cost of excavation.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed.
PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed.
M/S Chib Engineers
VEE ESS ENGINEERS
DARVESH ENGINEERING WORKS
M/S SHREE KRISHANA ENERPRISES
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .