| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹29.8 L+₹2.9 L (10.9%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹30.3 L+₹3.5 L (13.0%)Rejected-Finance H NO 29 1 3 PALACE COLONY MANDI DISTT MANDI H P | MANDI | HIMACHAL PRADESH | 175001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹31.1 L+₹4.2 L (15.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Contractor registration has been expired on 21.01.2022, hence not eligible as per NIT |
Tender Value
₹30.1 L
EMD Value
₹52,700
Closing Date
19 May 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Jal Shakti Division Sundernagar
CO Overhead storage tank 75000 ltrs capacity and jacketing of existing storage tank 60000 ltr capacity
2022_HPIPH_60646_1
EE JSD SNR etender 2021-2571-2620 dt. 13.5.2022
Open Tender
Civil Works - Water Works
Item Rate
180 days
Sundernagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
EE Sundernagar
₹52,700
Yes
20 Jul 2022
13 May 2022
20 May 2022
13 May 2022
19 May 2022
13 May 2022
120 days
Amount
Designing, constructing, testing and commissioning RCC Circular overhead storage reservoirs, under ground/partially under ground storage reservoirs as per capacity given below at various stages/sites including excavation in all kinds and types of strata, soil strata including dewatering in M30 design mix in foundation, walls bottom slab, roof slab/dome with smooth finishing in 1:3 inside the tank, all allied civil works, site development, cutting/excavation in all kinds of soils, C/O PCC/RCC retaining walls, breast wall, sanitary works i.e. refilling and disposing of suplus stuff within all leads and lifts, labour and material charges. The job also includes providing, lowering, laying, erecting hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipe with bye pass arrangement consisting of GI/MS pipes special and valves, bulk meter of required classes and dia & all other accessories required such as MS ladders inside and outside, CI cowl type ventilator, SFRC manhole ,indicator, covers including frame and covers (Medium Duty) with proper locking arrangement water level indicator, RCC frame for all valves ventilating shafts and barbed wire fencing around the tanks shall also be provided including all leads and lifts as per entire satisfaction of the Engineer-in-charge. The tanks shall be hydraulically tested for water tightness all works shall be conforming to relevant IS Code. The cost of valves shall be included in the rates of tanks, Battery limit shall be considered as 3.00m from the edge of the structure or the boundary of the land whichever is less. The rates quoted by the contractor shall be for the complete work. All ancilliary works and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account. The work shall include supplying of 5 sets of structural design and drawings etc. complete as directed by the Engineer-in-charge (i) C/O overhead tank 75000 ltrs. capacity 15m staging height at pt. B (Slapper Coloney). The overhead reservoir shall comprise of the following :- (a) Laying and jointing of Inlet, outlet, scour and over flow GI pipes (Medium class) with flanges of diameter 150mm complete with all pipe fittings such as tees, bends, tail pieces, flanges, pipe and valves shall be of appropriate size subject to the approval of the Engineer-in-charge. The over flow pipe shall be connected with any suitable delivery pipe. (b) Providing and fixing of MS sheet 3.15mm thick manhole cover 600x600mm. The frame of which size ISA-50x50x8mm shall be grouted fixed into the concrete. The MS sheet cover shall be fixed a angle and hinges to the frame. ( c) Cast iron ventilating pipes with cowl and mosquito proof cover of sufficient length) suitable for over head tank as per standard Engineering practice and subject to approval of the Engineer-in-charge. (d) All other required accessories such as ball mounts, control valves for inlet and outlet of 150mm cast Iron with ISA 50x50x8mm PN1.6 lightening conductor and water level guard (indicator) shall be provided by the contractor/firm. (e).Suitable RCC spiral stair case 60 cm wide for access upto the top of the tank and M.S. stair cage 60cm wide shall be provided in side the reservoir from top of tank to its bottom. (f) The tank shall be painted with water proofing cement paints outside complete in all respect. (g) There shall be 1 mtr. Wide gallery all around the tank with provision of necessary railing.
Providing and laying cement concrete 1:1.5:3 (one cement :one and half sand : three graded crushed stone aggregate 20mm nominal size ) and curing complete excluding the cost of form work and reinforcement in all leads and lifts in:- (a) Foundation ,footings bases of columns and the like mass concrete in all leads and lifts
(b) walls any thickness but not less than 0.1 mtrs. thickness attached pillasters , plinths and string courses etc.from top of foundation level upto floor two level including all leads and lifts .
Providing form work with steel plates 3.15mm thick welded with angle iron 30x30x5mm so as to give a fair finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4mtrs. and removal of the same for in-situ reinforced concrete and plain concrete work including all leads and lifts.(a) Vertical surface such as walls(any thickness) partitions and the like including attached pillasters buttresses, plinth and string courses and the like
Providing and laying cement concrete 1:2:4(1Cement :2 sand:4 graded crushed stone aggregate 20mm nominal size and curing completre excluding the cost of form work and reinforcement for reinforced concrete work in all leads and lifts in :-(a)Suspended floors, roofs, landing, shelves and their supports balconies, lintels, beams girders bresumers and cantilevers upto all floor two level .
Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete upto floor two level in all leads and lifts.
1.20 metre high fencing with 1.80 metre RCC posts 3.00m centre to centre with nine horizontal lines and two diagonal of galvanised mild steel barbed wire (IS: 278:1962 type-I) weighting 9.38 kg/100 metre strained and fixed to posts with 6.1 staples including cost of post, struts and straining bolts shall be paid for separately complete in all respect in all leads and lifts.
SHIV KANT PRASHAR
V S CONTRACTORS AND ENGINEERS
Oasis Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .