Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC NALLOOR H NALUKODY P O CHANGANCHERRY | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.1 L+₹9,535 (3.12%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹3.2 L
EMD Value
₹7,889
Closing Date
11 Sept 2024, 4:00 pmClosed
Assistant Executive Engineer
O/o Office of the Assistant Executive Engineer,Electrical Sub Division Pathanamthitta, (For and on behalf of Governor of Kerala)
GENERAL-Construction of a new building for Govt LP School Vadasserikkara-Electrification-General Electrical Work
2024_PWD_689029_1
PWD/BLDG/TR/14431/2024
Open Tender
Electrical Works
Item Rate
240 days
Vadasserikkara
Please refer Tender documents.
12 documents required · 12 mandatory
₹695
₹7,889
18 Nov 2024
3 Sept 2024
18 Sept 2024
3 Sept 2024
11 Sept 2024
3 Sept 2024
Amount
Construction of a new building for Govt L.P School, Vadasserikkara-Electrification-General Electrical Work
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD107612/2024-2025:Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
1.47:Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD107613/2024-2025: Supply and providing the following types and power rated lamps in the existing fittings as required.B22 LED bulb 9W
OD107614/2024-2025: Supply, conveyance, installation, testing and commissioning of cast aluminium stove enameled elliptical shaped bulk head fittings directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required.
90.5.1.6:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Gong bell 75mm-without MS box
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD107615/2024-2025:Supply and installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.<br>300 / 305 mm sweep light duty exhaust fan in metal frame.
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
OD107620/2024-2025:Supply and fixing Surge Protection Device (SPD), Type1+2 , discharge current 50kA(L-N), 70kA(N-E), protection level-1.5kV as required
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD107616/2024-2025:Supply and laying bare earthing conductors of the following sizes through the existing GI pipe/DWC pipe/RCC hume etc. as required. 3.15 mm copper conductor (10 SWG)
OD107617/2024-2025:Providing and fixing 20 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD107618/2024-2025:Supply and fixing meter box (SMC) having following specification. 1. Hinged door, seperate compartment for energy meter and accessories 2. Transparent window for viewing meter reading. 3. Suitable arrangement for fixing MCB/Isolator, single phase energy (KWh) meter etc. 4. 32A DP MCB. 5. 32A HRC fuse base with 25A fuse link 6. 32 A, 2 Way neutral links mounted on DMC/SMC base
OD107619/2024-2025:Supply and providing M8 anchor bolt hook in wall / parapet for binding support for service main
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD108809/2024-2025:SITC of 1 phases in and 1 phase out 1 kVA, without isolation transformer type, online UPS having 60 minute backup, connecting in stand-alone configuration with the following specification. a) input PF: 0.99 @ full load b) output PF: 0.95 or above c) input voltage range: 140V- 280V with cutoff d) THD: <=10% , e) overall efficiency:>=85%, f) ambient temperature : 0° C to 40° C, g) generator compatibility, h) pure sine wave, i) battery over charge & under charge cut off, j) bypass arrangement, k) EN/IEC 620401 for General Safety compatibility l) EN/IEC 620402 for Electromagnetic Compatibility m) EN/IEC 620403 for Performance n) EN/IEC 620404 or equal for Environmental compatibility o) LED+LCD Display p) Approved UPS make : APC/Fuji/Delta/Numeric q) Approved c10 rated tubular Battery make: Exide/Amaron Quanta/Panasonic r) Architecture; Tower type( rack mountable not acceptable ) s) Marking: CE, BIS, RoHS t) All certificate copy to be submitted u) Warranty: 3 year after SITC.
RAJEESH KUMAR R
Bidder Name
Xavier Joseph
RAJEESH KUMAR R
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1072326.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .