Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.0 LAccepted-AOC 60 19 CHANOT 125033 | CHANOT | HISAR | HARYANA | 125033 | L1 | Accepted-AOC Award | |
| 2 | L2₹1.2 Cr+₹36.6 L (41.5%)Rejected-AOC | L2 | Rejected-AOC Reject |
Tender Value
₹81.8 L
EMD Value
₹1.6 L
Closing Date
31 Aug 2020, 2:00 pmClosed
Executive Engineer, PHED No. 1 Gohana
Executive Engineer, PHED No. 1 Gohana Near MC Park Jind Road Gohana
MADINA- AUGMENTATION OF W/S SCHEME BY RENOVATION OF EXISTING STRUCTURES OF WATER WORKS, PROVIDING FUNCTIONAL HOUSEHOLD TAP CONNECTIONS (FHTC) AND LAYING OF BALANCE PIPE LINES IN VILLAGE DISTT. SONIPAT (UNDER JJM)
2020_HRY_140307_1
EIC Memo No. 70715-PHE/Mont. dt. 17-08-2020
Open Tender
Civil Works
Works
275 days
Village Madina
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Executive Engineer, PHED No. 1 Gohana
₹1.6 L
Yes
9 Sept 2020
20 Aug 2020
1 Sept 2020
20 Aug 2020
31 Aug 2020
20 Aug 2020
Amount
WATER TREATMENT PLANT (WTP) Design, construction, testing & commissioning of 0.50 MLD capacity Water treatment plant at Water Works Madina including inlet channel, Alum dozing, Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash, waste water tank including all civil work, pumping machineries and electric cabling, control panels, entire piping network of suitable size DI pipe from S & S Tank to Pump chamber, raw water pump to inlet box of WTP, WTP to CWT & Suction Well for CW including DI specials, suitable size Sluice valves, Hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed complete in all respects as per NIT (Sluice valves of make IVC/VAG) . DI pipe for the work will be supplied by the PHE Deptt. free of cost at Reserve stock Gohana.
Design, Supply & Erection of copper wound outdoor type Transformers of required KVA as mentioned below on load tap changer or suitable capacity on higher side of standard make outdoor type, VCB Panel, G.O. Switch, H.T. Metering Panels, APFC Panels along with for each Transformer, 11KV Substation, entire cable network from G.O. Switch to H.T. Metering equipment and from H.T. Metering to Transformer Main to L.T. Panel, Earthing, safety equipment and any other contingent thereto complete in all respect as per DNIT and getting it passed from Chief Electrical Officer including operation & Maintenance of 5 Years.- AT W/W = 63 KVA
Design, Supply & Erection of 1 No. DG Sets of required KVA as mentioned below suitable capacity on higher side capacity with Acoustic Canopy, AMF Panel and Copper Earthing of suitable rate with change over switch & synchronizing panel complete as per DNIT including operation & Maintenance of 5 Years.- AT W/W = 100 KVA
Operation and maintenance for the complete scope of work meintioned in the DNIT ( Disinfection material supplied by the PHED) as per schedule –IV for a period of 5 years after 12 month during defect liability period 3 months trial run ( will be changed to the A/mtc Estimate)-(i)-Opertation an Maintenance during Defect liability period (Operation Only)
(ii) Operation and maintencance during 1st year after defect liability period
(iii) Operation and maintenance during 2nd year
(iii) Operation and maintenance during 3rd year
(v) Operation and maintenance during 4th year
(v) Operation and maintenance during 5th year
Bidder Name
Amount
Ajay Yadav Contractor
Ajay Yadav Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .