Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC OLD MISSAMARI PO GARUBANDHA PS MISSAMARI DISTT SONITPUR ASSAM 784506 | MISSAMARI | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹24.3 L+₹1.4 L (6.14%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹26.3 L+₹3.4 L (14.7%)Rejected-Finance GARUBANDHA MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹26.8 L+₹3.9 L (16.9%)Rejected-Finance VILL BHELOWATER PO BORJULI PS RANGAPARA DIST SONITPUR ASSAM 784504 | SONITPUR | ASSAM | 784504 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹28.3 L+₹5.4 L (23.7%)Rejected-Finance CAMP AT GORUBANDHA MISSAMARI ASSAM 784506 | SONITPUR | ASSAM | 784506 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Saraswati Auto Works L5 | Maa Mira Enterprise L2 | bkgeneralstores L9 | M/S S.S.Corporation L6 | M/S RANA ENGINEERING ENTERPRISE L7 | United Traders L8 | M/s AKRITI ENTERPRISE L3 | DHEERAJ CONSTRUCTION L1 | S H ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantaling/taking old unserviceable ones complete all as specified and as directed.
NOTE : The unit rate includes for protection pipe and earth lead wire from top of earth plate up to 7.00 meter above ground level. | 185 | Each | 5,400 ₹9,99,000 | 4,800 ₹8,88,000 | 5,100 ₹9,43,500 | 5,200 ₹9,62,000 | 4,500 ₹8,32,500 Lowest | 6,000 ₹11,10,000 | 6,150 ₹11,37,750 | 4,750 ₹8,78,750 | 7,000 ₹12,95,000 |
| 2.00 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable and getting out in soft/loose soil complete all as specified and directed. | 20 | Cum | 210 ₹4,200 | 320 ₹6,400 | 225 ₹4,500 | 230 ₹4,600 | 290 ₹5,800 | 75 ₹1,500 Lowest | 375 ₹7,500 | 150 ₹3,000 | 100 ₹2,000 |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed. | 17 | Cum | 75 ₹1,275 | 120 ₹2,040 | 80 ₹1,360 | 130 ₹2,210 | 180 ₹3,060 | 75 ₹1,275 | 140 ₹2,380 | 150 ₹2,550 | 60 ₹1,020 Lowest |
| 4.00 | Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed. | 3 | Cum | 125 ₹375 | 280 ₹840 | 150 ₹450 | 140 ₹420 | 200 ₹600 | 75 ₹225 | 329 ₹987 | 100 ₹300 | 65 ₹195 Lowest |
| 5.00 | S&F Epoxy insulator suitable for fixing of eathing strip/GI earth wire complete all as specified and directed. | 250 | Each | 39 ₹9,750 | 90 ₹22,500 | 68 ₹17,000 | 40 ₹10,000 | 60 ₹15,000 | 25 ₹6,250 Lowest | 50 ₹12,500 | 37 ₹9,250 | 50 ₹12,500 |
| 6.00 | S&F in repair air termination, single pointed copper rod, 12 mm dia and 300 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed.
(NOTE: GI pipe & earthing strip shall be measured and paid seperately) | 160 | Each | 950 ₹1,52,000 | 800 ₹1,28,000 | 1,180 ₹1,88,800 | 250 ₹40,000 Lowest | 1,200 ₹1,92,000 | 600 ₹96,000 | 520 ₹83,200 | 350 ₹56,000 | 300 ₹48,000 |
| 7.00 | S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, including taking out unserviceable earth conductor complete all as specified and directed. | 1,000 | RM | 22 ₹22,000 | 20 ₹20,000 | 15 ₹15,000 | 16 ₹16,000 | 20 ₹20,000 | 6 ₹6,000 Lowest | 18 ₹18,000 | 19 ₹19,000 | 25 ₹25,000 |
| 8.00 | M&L Earthing complete with Copper Earth Plate Electrode 600x600x3.15mm thick buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to Copper Earth Strip 20x3mm and drawn through and including Galvanised Iron Protection Pipe 32mm bore (dia) ‘light grade’ upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Copper or Bronze Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of char coal or coke dust mixed with Common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded aggregate) and pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4(20mm graded aggre gate) reinforced with and including 8mm dia TMT Bars @10 Cm centre to centre both ways and suitable handle of 10 mm dia round bar, GI Wire Mesh, Funnel with GI Watering Pipe 20 mm bore (dia) ‘medium grade’, necessary Excavation in Soft/Loose Soil, Returning, Filling in and removal of Surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on completion including taking dismantling/taking unserviceable Earthing complete all as specified and as directed
NOTES : The unit rate includes for protection pipe and copper strip from top of earth plate up to 7.00 meter above ground level. | 12 | Each | 19,500 ₹2,34,000 | 25,000 ₹3,00,000 | 21,000 ₹2,52,000 | 22,500 ₹2,70,000 | 20,000 ₹2,40,000 | 26,500 ₹3,18,000 | 16,100 ₹1,93,200 | 16,500 ₹1,98,000 | 12,000 ₹1,44,000 Lowest |
| 9.00 | S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 32 x 6mm copper strip duly brazed complete all as specified and directed. | 45 | RM | 2,350 ₹1,05,750 | 1,400 ₹63,000 | 2,460 ₹1,10,700 | 4,120 ₹1,85,400 | 1,100 ₹49,500 | 2,800 ₹1,26,000 | 1,350 ₹60,750 | 3,000 ₹1,35,000 | 1,000 ₹45,000 Lowest |
| 10.00 | S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 20 x 3mm copper strip duly brazed complete all as specified and directed. | 66 | RM | 720 ₹47,520 | 1,340 ₹88,440 | 860 ₹56,760 | 1,412 ₹93,192 | 880 ₹58,080 | 1,200 ₹79,200 | 580 ₹38,280 | 1,100 ₹72,600 | 500 ₹33,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
23 Sept 2025, 6:00 pmClosed
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIR MAINTENANCE OF VARIOUS TYPES OF EARTHING PITS INCL LIGHTENING PROTECTION UNDER GE MISSAMARI
2025_MES_728837_1
8562/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE MISSAMARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MISSAMARI
₹64,000
Yes
28 Nov 2025
2 Sept 2025
25 Sept 2025
2 Sept 2025
23 Sept 2025
16 Sept 2025
2 Sept 2025 - 9 Sept 2025
Amount
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantaling/taking old unserviceable ones complete all as specified and as directed. NOTE : The unit rate includes for protection pipe and earth lead wire from top of earth plate up to 7.00 meter above ground level.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed.
Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
S&F Epoxy insulator suitable for fixing of eathing strip/GI earth wire complete all as specified and directed.
S&F in repair air termination, single pointed copper rod, 12 mm dia and 300 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed. (NOTE: GI pipe & earthing strip shall be measured and paid seperately)
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, including taking out unserviceable earth conductor complete all as specified and directed.
M&L Earthing complete with Copper Earth Plate Electrode 600x600x3.15mm thick buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to Copper Earth Strip 20x3mm and drawn through and including Galvanised Iron Protection Pipe 32mm bore (dia) ‘light grade’ upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Copper or Bronze Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of char coal or coke dust mixed with Common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded aggregate) and pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4(20mm graded aggre gate) reinforced with and including 8mm dia TMT Bars @10 Cm centre to centre both ways and suitable handle of 10 mm dia round bar, GI Wire Mesh, Funnel with GI Watering Pipe 20 mm bore (dia) ‘medium grade’, necessary Excavation in Soft/Loose Soil, Returning, Filling in and removal of Surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on completion including taking dismantling/taking unserviceable Earthing complete all as specified and as directed NOTES : The unit rate includes for protection pipe and copper strip from top of earth plate up to 7.00 meter above ground level.
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 32 x 6mm copper strip duly brazed complete all as specified and directed.
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 20 x 3mm copper strip duly brazed complete all as specified and directed.
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6 mm thick, buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to GI Earth Strip 32 x 6 mm drawn through and including GI Pipe 40 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, including dismantling/taking out unserviceable Earthing and connected Items, complete all as specified and as directed NOTES : The unit rate includes for protection pipe and copper strip from top of earth plate up to 7.00 meter above ground level.
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 32 x 6mm GI strip complete all as specified and directed.
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 25 X 3mm Aluminum strip complete all as specified and directed.
S&F in repair Test point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw in a test point box complete all as specified and as directed.
M&L 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in earthing strip protection laid in trenches/road/floor complete all as specified and as directed.
M&L making of PCC Chamber cover in PCC (1.3:6) type C1 (using 20 mm graded stone aggregate) with Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both provision of handle with 10 mm MS bar and GI wire mesh and Funnel for water pipe complete all as shown in Electrical Plate No. 3 of MES Schedule Part-I and as directed
M&L for adding industrial salt (minimum 25 Kg upto 35 KG per pit) dully mixed with water to get the desired values complete all as directed.
S&F in repair air termination, single pointed copper rod, 12 mm dia and 600 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed. (NOTE: GI pipe & earthing strip shall be measured and paid seperately)
M&L Lightning arresters expulsion type, 11000 Volts,complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as directed.
S&F Junction Box of size 217x253x115 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, (without mounting plate) with transparent lid, rubber gasket, water tight, IP 66 protection for housing of test point and fixed on wall with sutable size of screws as directed including removal of exiting unserviceable all as specified and directed. Note :- Cable glands shall be fixed in inlet and out let of junction box and rate of Cable glands is deem to be included in quoted rate.
Maa Mira Enterprise (BID ID -3431581)
M/s AKRITI ENTERPRISE (BID ID -3431791)
S H ENTERPRISES (BID ID -3433828)
Saraswati Auto Works (BID ID -3429846)
M/S S.S.Corporation (BID ID -3433015)
M/S RANA ENGINEERING ENTERPRISE (BID ID -3433030)
United Traders (BID ID -3433435)
bkgeneralstores (BID ID -3432967)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .