| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.7 L+₹4.0 L (15.4%)Rejected-Finance KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | L2 | Rejected-Finance Being higher than L1 bid | |
| 3 | L3₹31.5 L+₹5.8 L (22.5%)Rejected-Finance | L3 | Rejected-Finance Being higher than L1 bid | |
| 4 | L4₹31.7 L+₹6.0 L (23.2%)Rejected-Finance | L4 | Rejected-Finance Being higher than L1 bid | |
| 5 | L5₹32.0 L+₹6.3 L (24.4%)Rejected-Finance | L5 | Rejected-Finance Being higher than L1 bid |
Tender Value
Refer Docs
EMD Value
₹59,900
Closing Date
21 Sept 2020, 6:00 pmClosed
GARRISON ENGINEER SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
REPAIRS/MAINTENANCE OF LT UG CABLE, MCCB, FEEDER PILLAR BOX AND OTHER ACCESSORIES AT MASIMPUR MILITARY STATION UNDER GE SILCHAR
2020_MES_370721_1
8559/E8
Open Tender
Electrical and Maintenance Works
Item Wise
270 days
MASIMPUR
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹59,900
Yes
29 Sept 2020
20 Aug 2020
22 Sept 2020
21 Aug 2020
21 Sept 2020
4 Sept 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 mtr and not exceeding 3 mtr in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
Supply and lay old size brick of size 230x115x75 mm for cable protection in trenches all as specified and directed.
Materials and labour for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in coping and like including necessary fromwork complete all as specified and as directed.
Taking out existing old damaged / unserviceable LT UG cable, PVC/XLPE insulated, steel strip /wire armoured multistranded aluminium conductor cable from trench /duct /pipe. etc of any sizes complete all as specified.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 300 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 120 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 50 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 35 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 25 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 16 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply and laying 80 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under road, on wall or on pole with and including clamps, nuts, bolts etc including taking down old unserviceable GI tubing of any size including cutting, chases to wall/floor & making good complete all as specified and as directed.
Supply and laying 50 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under road, on wall or on pole with and including clamps, nuts, bolts etc including taking down old unserviceable GI tubing of any size including cutting, chases to wall/floor & making good complete all as specified and as directed.
Supply and laying cable route indicator made of RCC of dimension 900 x 300 x 50 mm for LT cable manufacturered as per latest IS all as specified.
Supply and fix MCCB 4 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 500 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description and all as specified.
Supply and fix MCCB 4 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 350 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description and all as specified.
Supply and fix MCCB 3 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 250 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description and all as specified.
Supply and fix MCCB 3 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 400 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description and all as specified.
Supply and fix MCCB 3 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 160 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description and all as specified.
Material and labour for straight through joints (epoxy) of size 150 sqmm 3.5 Core 1100 Volt including joint kits and labour complete for making joints suitable for UG cables complete all as specified.
Relaying of existing LT cable in trenches all as specified and directed including cable lugs, cable glands etc. Note:- Earth work, bricks, sand filling etc shall be measured and paid separately.
Material and labour for boring of hole under roads with mechanical arrangement upto 80mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and directed.
Material and labour PCC 1:2:4 type B1 using 20mm graded crushed stone aggregrate with 100mm thick for flooring of sub stn areas complete all as specified.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX60ommX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX60ommX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to Galvanised Iron strip 25 x 4 mm as earthing lead and protected by 40 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed.
Material and labour for Galvanised iron earthing strip of size 32x6mm burried in ground complete all as specified.
Re-fixing only Galvanised iron earthing strip of size 32x6mm burried in ground all as specified.
Material and labour for synthetic Insulating mat of size 2mx1mx10mm confirming to IS all as specified and directed.
Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified.
Material and labour for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick masonry (valve pit/brick pillar) or concrete surface, finished the surfaces even and smooth with using extra cement complete all as specified.
Supply only course aggregate for loose filling of gauge 40 mm to 80mm graded all as specified.
Supply and fix offload changeover switch-AC 21 (Side handle) 400 Amp Four pole, 415 Volts AC, 50HZ, including taking down all as specified. Make :- Havells Cat part No-IHBFFE0400 or equivalent make of L&T/ Seimens/Schinder/ABB.
Supply and fix onload changeover switch-AC 23 (Side handle) 63 Amp Double pole, 415 Volts, 50HZ, including taking down all as specified. Make :- Havells Cat part No-IHBFFE0063 HSN Code 8536 or equivalent make of L&T/ Seimens/Schinder/ABB.
Supply and fix onload changeover switch-AC 23 (Side handle) 100 Amp Double pole, 415 Volts , 50HZ, including taking down all as specified. Make :- Havells Cat part No-IHBFFE0100 HSN Code 8536 or equivalent make of L&T/ Seimens/Schinder/ABB.
Supply and fix street light panel Three phase, 6KW Astronomical (timer), 32/TP (contacor rating Amp), 40/TPN (MCB Rating including taking down all as specified. Make ;- Havells Cat part No- IHXTS0306A or equivalent make of Crompton/Legrands/ Seimens/Schinder.
Suppy and fix Electronic timers type ST 100 for 240/360/415V, 50 Hz including taking down all as specified. Make :- L&T Cat part No ST80328OOOO or equivalent make of Crompton/Legrands/ Seimens/Schinder.
M/S SANJIB DEB
m/s builders and suppliers
Anup Kumar Paul Choudhury
MS AFTAB LASKAR
M/S Mamoni Construction
M/S TAPAN KUMAR RAY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .