Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹37.3 L+₹8.2 L (28.2%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance BEING L2 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
17 Jan 2024, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
DAY TO DAY PETTY ELECTRICAL REPAIRS / DAY TO DAY MAINTENANCE AT NEW / OLD DARJIPURA AREA AND OTM ACCN AT AFS VADODARA
2023_MES_633014_1
8864/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
4 documents required · 4 mandatory
₹500
GE AF BARODA
₹70,000
Yes
8 Mar 2024
15 Dec 2023
24 Jan 2024
15 Dec 2023
17 Jan 2024
3 Jan 2024
16 Dec 2023 - 22 Dec 2023
Amount
Attending the complaints lodged by the occupants/users including Identifying and rectifying of electrification nature & rectification of the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs in respect of main fixture /breakdown for light/fan/bell/light or power socket and LT line etc complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/ Exhaust fans and other type of complaints to connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and respect of item if required to be paid under respective item as required complete all as specified and directed
Attending the complaints lodged by the occupants/users including Identifying and rectifying of electrification nature & rectification of the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs No light complaint, loose wire, sparking etc in LT panel at AFS Makrpura and all HT LT fault emergency complaint and any type of complaint regarding electricity complete all as specified and directed
NOTE FOR ITEM NO 1.00 & 2.00:- (a) All T & P/Stationeries and labour team required comprising of sufficient trained technician (Electrician / helper ) will be provided by the contractor daily for two location ie harni camp and harni airfield Baroda area as directed. During MES mela or any other occason the contractor will require to be arrage additional menpower to rectify the complaint within justified time. b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 17.30 Hrs the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor.
NOTE FOR ITEM NO 1.00 & 2.00:- (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size, lubricating oil/grease etc shall be deemed to be included in the above quoted rate. However, major items such as switches, sockets, bell push, fan regulator, capacitor, wires etc shall be measured and paid separately under appropriate items of BOQ. (d) Complaints pertains to complete replacement of circuit/point wiring shall be measured under relevent item. (e) If contractor fails to rectify the complaint with in 24 hours after receiving, Rs 500/- per complaint will be penalised.
Supply only piano switch flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified and directed
Supply only bell push, 6 Amps, flush type, 230/250 Volts, 50 Hz complete all as specified and directed
Supply only piano switch flush type 15 Amps single pole, one way 230 volts AC circuit complete all as specified and directed
Supply only socket out let 2 in 1, 3 pin 5 Amps flush type, 230 volts Ac circuit complete all as specified and directed
Supply only Switch socket combination 2 in 1, 3 pin, 5 Amp flush type 230 volts AC circuit complete all as specified and directed
Supply only Switch socket combination 2 in 1, 3 pin, 15 Amp flush type 230 volts AC circuit complete all as specified and directed
Supply only switch socket combination with junction box 2 in 1, 3 pin 5 Amps flush type, 230 volts Ac circuit complete all as specified and directed
Supply only switch socket combination with junction box 2 in 1, 3 pin 15 Amps flush type, 230 volts Ac circuit complete all as specified and directed
Supply only socket out let 2 in 1 multi purpose three pin, 15 Amps & three pin 5 Amps controlled by one switch, flush type 230 volts AC circuit complete all as specified and directed
Supply only ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed
Supply only lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed
Supply and fixing 5 Amp plug top complete all as specified and directed
Supply and fixing 15 Amp plug top complete all as specified and directed
Supply only bulk head luminaries LED 10 watt lamp comprising of deep drawn anodized aluminium body epoxy shite powder coated complete with accessories complete all as specified and directed.
Supply only indoor decorative channel housing fitting slim LED batten 10 Watt (Mirror Light) 2 Feet with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same with two Nos PVC square box complete all as per specified and directed.
Supply only copper LED Tubelight fitting with battery/Inverter, ENERGY Efficient 20 Watt 2000 lumen bright light with 25000 burning hours with min 4 hrs battery backup complete all as per specified and directed.
Supply only LED Tubelight fitting with ENERGY Efficient 20 Watt bright light complete all as per specified and directed.
Supply only LED motion sensor security light luminaire 25 watt freedom , pressure die cast aluminum housing, heat resistant glass, IP66 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as per specified and directed.
Supply only switch piano Modular type single pole one way 10 Amp 240 Volts complete all as specified and directed
Supply only switch piano Modular type single pole two way 10 Amp 240 Volts complete all as specified and directed
Supply only switch piano Modular type single pole one way 16 Amp 240 Volts. complete all as specified and directed
Supply only socket only 6 Amps 2 in 1 Socket with Shutter Modular type 240 Volt complete all as specified and directed
Supply only socket only 6/16 Amps Twin Socket Modular type 240 Volt complete all as specified and directed
Supply only Bell push switch Modular type single pole one way 10 Amp 240 Volts.complete all as specified and directed
Supply only Fan Regulator 240 Volts complete all as specified and directed
Supply only Fan Regulator two module 4 step FSC Modular type 240 Volts complete all as specified and directed
Supply only LED bulb 09 Watt 5 star rating complete all as specified and directed
Supply only door bell ding dong, multi tune, Chime and Buzzer complete all as specified and directed
Supply only 2.5mfd capacitor suitable for ceiling fan complete all as specified and directed
Supply only sheet metal enclosure SP with two pin and socket with one single pole MCB 32 Amps, 'C' Curve 240 Volts complete all as specified and directed
Supply only metal socket 20 A 2 pole + earth 240 volt complete all as specified and directed
Supply only metal plug 20 A 2 pole + earth 240 volt complete all as specified and directed
Supply and fix in repairs MCB DB 4 way (VTPN) vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified and directed Note : (i) Copper thimble shall be used for connection of cable . (ii) MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule.
S & F in repairs MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directed Note : Copper thimble shall be used for connection of cable.
Description all as per item No 36.00 here-in-before but 8 way.
Description all as per item No 36.00 here-in-before but 12 way.
Supply only MCB, single pole 240 volts 6 to 32 Amps capacity C series fixed in DB's. complete all as specified and directed
Supply only MCB, single pole and neutral link 240 volts 40 to 63 Amps capacity C series fixed in DB's. complete all as specified and directed
Supply only MCB, single pole 240 volts 40 to 63 Amps capacity C series fixed in DB's. complete all as specified and directed
Supply only MCB four pole 63 amps 10 KA 415 Volts C series complete all as specified and directed
Supply only FR-LSH PVC insulated, unsheathed, single core, flexible copper conductor wire suitable upto voltage grade 110 volt of different colours and following sizes complete all as specified and directed
Supply only PVC casing Caping complete all as specified and directed
S & F of PVC conduit size 20mm Rigid non-metaLlic PVC conduit exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mount tube ends and fixing accessories including chase cutting such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply only SS screw of 1.5 inch size comlete complete all as specified and directed
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 2 module with white cement concealed and making good the disturbed surface as per existing complete all as specified and directed Note:- Cost of labour paid separatly.
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 4 module with white cement concealed and making good the disturbed surface as per existing complete all as specified and directed Note:- Cost of labour paid separatly.
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 6 module with white cement concealed and making good the disturbed surface as per existing complete all as specified and directed Note:- Cost of labour paid separatly.
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 8 module with white cement concealed and making good the disturbed surface as per existing complete all as specified and directed Note:- Cost of labour paid separatly.
Supply only Hylum sheet Size 9” x 11”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete complete all as specified and directed
Supply only Hylum sheet Size 10” x 12”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete complete all as specified and directed
S&F Exhaust fan louvers steel body for 300 mm sweep in replacement complete all as specified and directed.
S&F Exhaust fan louvers steel body for 450 mm sweep in replacement complete all as specified and directed.
Supply only fan blade of 1200/1400 sqmm complete all as specified and directed.
Supply only Fan Hook/clampcomplete all as specified and directed.
Supply only exhaust fan 200mm sweep, made of sturdy engineering plastic, excellent impact and abrasion resistance, blade design Aerodynamically designed & Balanced Blade Operating Voltage: 230 volts, Number of blades: 5. Noise level:42 dB complete all as specified and directed
Supply only MCCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified and directed Note : (i) Rate of MCCB 4P/TPN shall be deemed to be included in item rate no extra payment to be measured and paid seperately under appropriate items of this schedule . (ii) Copper thimble shall be used for connection of cable
Supply only exhaust fan 250mm sweep, made of sturdy engineering plastic, excellent impact and abrasion resistance, blade design Aerodynamically designed & Balanced Blade Operating Voltage: 230 volts, Number of blades: 5. Noise level:42 dB complete all as specified and directed
Supply only wall mounted light fitting suitable for retrofit LED lamp upto 14 watt B22 champagne gold finish fixture with plastic body, Opal white PC diffuser for glare free light complete all as specified and directed
Supply Only LED Tubelight T-8 fitting with LED Tube Rod, Energy efficient 20 Watt bright light complete all as specified and directed.
Supply Only LED Security Light luminaire 25 Watt freedom, pressure die cast aluminium housing with heat resistant glass, IP-66 Protection, better optics for uniform distribution complete with all accessories internally prewired and including connecting up with three core 1.5 Sqmm flexible conductor cable from ceiling rose to connector light complete all as specified and directed.
Supply Only anti suicide fan rod complete all as specified and directed.
Badri Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .