| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 Cr+₹1.6 L (1.16%)Rejected-AOC | ₹1.4 Cr+₹1.6 L (1.16%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical L3 |
Tender Value
₹1.3 Cr
EMD Value
₹50,000
Closing Date
28 Oct 2021, 6:00 pmClosed
MD,KPHCC
KERALA POLICE HOUSING AND CONSTRUCTION CORPORATION LTD CHANDRASEKHARAN NAIR STADIUM, PALAYAM, THIRUVANANTHAPURAM - 695033
Balance Estimate for the Construction of Forest Station Complex at Chalakudy, Thrissur Near Social Forest Ststion Complex at Chalakudy DSR 2016 with new cost index 37.25
2021_KPHCC_446744_1
39/KPHCC/2021-2022(02)
Open Tender
Civil Works - Buildings
Item Rate
180 days
CHALAKUDY
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,600
Yes
₹50,000
Yes
16 Dec 2021
20 Oct 2021
30 Oct 2021
20 Oct 2021
28 Oct 2021
20 Oct 2021
20 Oct 2021 - 28 Oct 2021
Amount
APPENDIX A : CIVIL WORK (ORIGINAL SCHEDULE)CIVIL WORKS4.1.8.Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for foundation - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
5.9.19.Centering and shuttering including strutting, propping etc. and removal of form work for Weather shade, Chajjas, corbels etc., including edges.
5.9.3.Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platform.
5.33.2 All work above plinth level upto floor V level
5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein.
O.D.Solid block masonry using precast solid blocks (Factory made)of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level with thickness 15cm in CM1:6(1cement:6coarse sand) etc. complete.
Solid block masonry using precast solid blocks (Factory made)of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor five level with thickness 15cm in CM1:6 (1cement: 6coarse sand) etc. complete.
9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
9.1.2 O.D.Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Anjily wood
9.5 .O.D.Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer in-charge.
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc
9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm,made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge.
9.120.2 30 mm thick pre laminated PVC door shutters
13.4 12 mm cement plaster of mix: 13.4.1 1:4 (1 cement : 4 coarse sand)
13.16 6 mm cement plaster of mix: 13.16.1 1:3 (1 cement : 3 fine sand)
13.9 cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement.13.9.1 12 mm cement plaster
Stainless steel tower bolt 150mm
Stainless steel hooks and eyes
250mm Stainless steel Aldrop
Stainless steel door handle
Supplying padlock 6lever
11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. 11.41.1 Size of Tile 500x500 mm
13.85 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.13.85.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre
13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: 13.61.1 Two or more coats on new work
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
13.40.Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade :
Supplying and fixing granite stone laid over CM 1:4,12mm thick cement mortar in kitchen slab
APPENDIX B-WATER SUPPLY AND SANITARY WORKS17.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:17.2.1 W.C. pan with ISI marked white solid plastic seat and lid
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C. P. brass pillar taps
17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:17.10.1 Kitchen sink with drain board17.10.1.1 510x1040 mm bowl depth 250 mm
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supplying, laying and jointing 110mm dia, 4 kgf/cm2 PVC pasted pipe for water line as open work and kept in position with specials such as tees, bends, elbows, checknuts etc. with clamps including cutting and making good the walls painting the exposed portions of the pipes with suitable paint two coats etc. complete.
Providing and fixing 63 mm dia ISI 6 Kgf/cm2 pipes. This includes jointing of pipes & fittings with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in- Charge. External work.
Providing and fixing 32 mm dia ISI 10 Kgf/cm2 PVC pasted pipes for water supply, including all PVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step PVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.
Providing and fixing 25 mm dia ISI 10 Kgf/cm2 PVC pasted pipes for water supply, including all PVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step PVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.
Supply and fixing 25mm Steel long body tap
Supply and fixing 110x110mm steel gratings
APPENDIX C-CONSTRUCTION OF SEPTIC TANK AND DRY PIT2.8.1.Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
4.1.8.Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for foundation - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:4.1.2 1:1½ :3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.5.Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 5.22.6.Thermo-Mechanically Treated bars
13.9 cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement.13.9.1 12 mm cement plaster
Dry rubble masonry for Soak pit including cost and conveyance of all materials and labour charges etc. complete.
APPENDIX D-ELECTRICAL (ORGINAL SHEDULE)Wiring for light point / exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular type switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Wiring light point in the above system ( Short Point)
Wiring light point in the above system ( Medium Point)
Wiring light point in the above system ( Long Point)
Wiring light point in the above system ( Two way Point)
Supply and wiring fan point as detailed above with 3 plate ceiling rose and Electronic step regulator, front cover, modular metal box etc as per PWD specification Short Point
Medium Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required
Supply and Fixing TV point by fixing TV Socket in the suitable size Metal box in recess and making good the suface of the wall colour washing etc as required (Modular Group B )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in recess/surface including cutting the wall and making good the same in case of recessed conduit as required.20mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 X 1.5 Sqmm
3 X 2.5 Sqmm
3x4 Sqmm
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
Supply and drawing bare copper conductors of the following sizes along with wiring/cables and giving connections etc as required. 8 SWG
Supply and drawing bare copper conductors of the following sizes laid 0.6M below ground level including excavating trench of suitable size and refilling as required. 8 SWG
Supply and fixing superior quality(Dowell’s) copper earth socket for the following sizes of earth conductor including crimping etc. as required. 8 SWG
Supplying,laying and clamping of one number pvc insulated and PVC sheathed armoured Aluminium power cable 1.1 KV grade of the following sizes using clamps noted along with the cables spacing of clamps not exceeding 60cms making good the damages colour washing etc as required 4 x 50 qmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required 4 x 50 Sqmm
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240 Volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240 Volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. Triple pole
Supplying and fixing following rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Supplying and fixing following rating, , four pole 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Supplying and fixing following rating,double pole (single phase and neutral) 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Supplying and fixing following rating, 415 V, four pole (three phase and neutral) residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 6 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 4 way (4 +12) Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board of sheet steel,dust protected,duly power painted, inclusive of 200A, tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer)as required. (note: vertical type MCB TPDB is normally used where 3 phase outlets are required) 4way (4+12) Double door
Supply,conveyance,installation,testing and commissioning of ceiling fans of the following sizes using standard accessories ,wiring the down rod with 16/0.20mm pvc insulated and pvc sheathed 650/1100v grade 3 core round copper conductor flex wire or with extended original wiring etc.as required.1200 mm sweep (5 star Rated)
Supply, conveyance, installation, testing and commissioning of the 9" dia sizes (225mm)of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supply and providing plate earthing as per IS 3043 with 600x600x6 mm GI/CI earth plate, 20 mm GI watering pipe2.7m long fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete, brick work in cement mortar 1:6, plastering the surface of brick masonry including test joint and Top cover slab(400x400x50mm RCC) of the chamber.
ADDITIONAL ITEM -APPENDIX A : CIVIL WORK2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
5.9.5.Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.19.Centering and shuttering including strutting, propping etc. and removal of form work for Weather shade, Chajjas, corbels etc., including edges.
5.33.1.Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 5.22.6 Thermo-Mechanically Treated bars
9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
13.4 12 mm cement plaster of mix: 13.4.1 1:4 (1 cement : 4 coarse sand)
13.16 6 mm cement plaster of mix: 13.16.1 1:3 (1 cement : 3 fine sand)
13.9 cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement.13.9.1 12 mm cement plaster
8.31Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
13.40.Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade :
8.2.2.1Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
11.41.1Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm.
11.48.1Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 500x500 mm
Supplying and fixing 25 mm thick ferrocemnt slab in cluding all cost and conveyance and labour charges etc complete. (MR 860 per sq,m)
50.2.25.1Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
OD Site clearance using JCB
OD Engaging tipper
8.2.2.1Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
11.41.1Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm.
11.48.1Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 500x500 mm
Supplying and fixing 25 mm thick ferrocemnt slab in cluding all cost and conveyance and labour charges etc complete. (MR 860 per sq,m)
50.2.25.1Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
OD Site clearance using JCB
OD Engaging tipper
4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
8.3.2 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge. Granite work
4.2.3Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
50.9.15.4 Providing and fixing iron hooks and eyes: 150 mm
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
50.10.1 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Providing water cutting on the border of sunshade and roof slab projection in CM1:3,15mm thick and of 25mm wide including watering, curing, cost and conveyance of all materials and labour charges etc. complete
APPENDIX B : WATER SUPPLY AND SANITARY WORKS(ADDITIONAL)50.18.8.4.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
50.18.9.9.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.17.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.19.2 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
19.4.1.1 Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.30.1.1 Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
18.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
18.17.5Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
supply and fixing 32 mm tank connector(MR)
supply and fixing 63 mm tank connector(MR)
18.18.3 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 25 mm nominal bore
Providing and fixing PTMT stop cock of approved quality and colour 20 mm nominal bore, 89 mm long, weighing not less than 88 gms
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
Supply and fixing good quality 200mm dia CP shower with 450mm long showerarm and 20mm shower cock including cost of material and labour charge etc (Cera, Jagur, or equalent) complete.
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
18.74.1 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, Collar and bush approved quality and colour 15 mm nominal bore with 30 cm length
"Modified 17.8" Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.(CERA OR EQUALENT MADE)
18.65 Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes
OD Providing and fixing C.P. brass kitchen sink tap of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
Supplying and fixing Nahni trap with cement concrete using 20mm broken stones including cutting open, boring through masonry walls, RCC floors etc. and making good the damages.
Supply and fixing 75 mm Stainless Steel split saddle clamp (MR)
Supply and fixing 110mm Stainless Steel split saddle clamp (MR)
OD Core cutting + hole packing using GP2 Conbextra and supports RCC (upto 30 cm thickness) 110 mm
Supplying and fixing 1500mm dia RCC ring to the thickness of 5cm thick and 30cm height with CC 1:2:4 using 20mm size hard granite broken stones for soakpit to drainage etc.complete.
Supply and fixing 10 mm dia stainless steel thread rod
APPENDIX C-ELECTRICAL(ADDITIONAL)Supply and providing 9W LED bulb of approved make like Philips,havells or equivalent.
Supply installation testing and commissioning of 20W LED tube of govt approved make like Philips/Havells/wipro or eqivalent with all accessories and giving proper connections as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 5 x 6 sq. mm
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 1 run of Cable
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 32A DP switch with indicator
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 25A 3pin Shuttered socket
supply testing and fixing of 9w fancy light with bulb including all accessories and connection etc.
Supply and fixing of 12W led surface mound light . Havalls/philips/wipro or equivalent make,giving connections etc complete as required.
Supply and fixing of 6W led surface mound light . Havalls/philips/wipro or equivalent make,giving connections etc complete as required.
Supply and fixing of 3w WH outdoor wall light LODARCS-3D 3000K .including all accessories as required for complete installation (wipro/luker/equivalent)
Supply and fixing of 6w WH outdoor wall light LODARCD-6D 3000K .including all accessories as required for complete installation (wipro/luker/equivalent)
Supply installation testing and commissioning of 45W LED outdoor IP66 street light made up of die cast aluminium housing with diffuser , complete set Govt approved and reputed brands on 40 mm or nearest suitable size B class GI pipe cut and weld,bend to shape fixed on wall using flatclamps. Havalls/philips/wipro or equivalent make,giving connections etc complete as required.
Supply installation testing and commissioning of 10W outdoor led die cast aluminium housing bulk head with IP65 ,all accessories ,electrical connections.including fixing materials required. make-philips/wipro/havells or equivalent
Supply and fixing of 3W led surface mound light . LUKER(LNPSRS03) or equivalent make,giving connections etc complete as required.
Fabrication, supply & installation of 16 SWG galvanized plain sheet wall mounting powder coated Electrical panel board for fixing 12 nos of 3phase KSEB energy meter compartment, including cable chamber (provision for sealing) and Incomer-150A TPN SFU with 3phase Aluminium bus bar(25 x10), 40A 4p isolator-11nos ,63A4p isolator -1no ,neutal link,fuse units for each 3ph connections and indication lamp, including additional one free compartment and proper connections (including all accessories) etc as required. excluding 3phase meter
Providing and Fixing of Electrical ISI Grade Rubber Mat suitable for 440Volts Switchboards. (2000 x 1000 x 6mm)
Supply and laying 3cx 2.5 sqmm submersible cable make v guard or equivalent reputed brand and giving connections etc as required
Supply and fixing of submersible 1.5 hp motor make v guard or equivalent reputed brand and giving connections with hanging rope etc as required
Supply testing and fixing of Automatic water level controller with dryrun function controlled by floating switch make sinicon/video or equivalent reputed brand and giving connections etc as required excluding energy meter
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door
1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required
Fees for preparation of three phase single line drawing,load caluculation in the prescribed form of KSEB,submiting to the KSEB (all statuory fees should be paid by Clint)
Supply and fixing of CAT6 I/O socket in the existing suitable modular plate and suitable gi box ,giving proper connection as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2nos 3 pin 5/6 A modular socket outlet and 2nos. 5/6 A modular switch, connections etc. as required.(for light plugs to be used in non residential buildings)
1.17.23 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 5 x 4 sq. mm
Kurian Varghese
SAJI KURUVILA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_637214.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .