Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.0 LAccepted-AOC FIRST FLOOR 271 B SURYA DARSHAN TOWNSHIP MANJALPUR VADODARA GUJARAT 390011 | VADODARA | GUJARAT | 390011 | 1 | Accepted-AOC L1 BIDDER | |
| 2 | Rejected-Technical | - | Rejected-Technical Bidder has replied to TQ and uploaded the complete SOR. However, No Line item of both the Work Order is in-line with the BEC requirement. Hence Completed or Executed value for Polycarbonate Sheet Works cannot be determined on the basis of documents s |
| Sl No | Description | Qty | Unit | BANSAL ASSOCIATES L1 |
|---|---|---|---|---|
| 1.00 | Designing, supplying, fabricating and erecting Aluminium composite Panel of 4 mm thickness with exterior grade composed of a low density polythylene core sandwiched between two sheets of aluminium of 0.5 mm thickness ( 0.5+3.0+0.5) the colour shall be beige metallic or other shades as directed at site of work with Eurobond/ Alu bond sheet in combination with other shades and fabricated on hozier machine with necessary
sub frame of 40 x 40 x 2 mm with stiffener etc., and fixed on the main frame work made up of specially designed anodised aluminium vertical section of size 112.5 mm x 70 mm x2.5 mm and horizontal section of 82.50 mm x 68.50 mm x 2.5 mm at required at all levels and heights of the proposed building.
The aluminium composite panel shall be bent in the tray form to the required sizes and fixed to frame work at wherever required with necessary adapters, cleats, clamps etc., and finished with backer rod, Dow corning 789 weather sealant etc., all as per manufacturer's specifications and as directed at site of work including all labour, materials, bolts and nuts, tools, labour, tools, tackles, lifts, equipments, transportation fuel, etc., complete including necessary suspension piece.
Aluminium composite panel cladding with anodized aluminium sections, frame work, sub frame, stiffener, cleats, clamp, adapter, scaffolding etc., complete. Make: Alstone. Panel of approved shade for modification in existing Structure, as required. | 40 | M2 | 6,000 ₹2,83,200 Lowest |
| 2.00 | Disposal of Rubbish/Dismantled glass upto 5 km to the dumping site | 40 | M3 | 250 ₹11,800 Lowest |
| 3.00 | Providing and fixing 10 mm thick solid, UV protected Polycarbonate sheet in Transparent Colour (Make: Bayer/ Lexun/ PRIME) by reusing the existing structure using 60 mm aluminium base profile and aluminium cap profile, (L Cock system), EPDM dome rubber gasket and fixed with high carbon self-drilling screws with washers including providing and fixing anti dust non-woven tape system wherever required with Aluminium/ Polycarbonate edge profile to protect edges all complete as per the specifications (IS CODE- IS 14443 : 1997) Including wastage etc. Including transportation cost. Including cost of scaffolding up to 5 m height.
DESIGNATION/CLASSIFICATION of Polycarbonate Sheets is as below:
IS PC1SP LHTN 7234 V3
(Finished plan area of Polycarbonate Sheet after installation shall be measured for payment) | 80 | M2 | 6,000 ₹5,66,400 Lowest |
| 4.00 | Fill the gaps formed during the installation of Polycarbonate sheet in the walls and in the necessary places to prevent water leakage from the newly installed polycarbonate sheet with Silicone Sealant of suitable colour with gun complete in all respects. | 300 | M | 100 ₹35,400 Lowest |
Tender Value
Refer Docs
Closing Date
24 Jul 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AJAY KUMAR MEENA
GAIL INDIA LIMITED VADODARA
HIRING OF CONTRACT SERVICES FOR REPLACEMENT OF PORTICO TOUGHENED GLASS WITH 10 MM POLYCARBONATE SHEET AT GAIL RPNHQ OFFICE RECEPTION
2025_GAIL_240567_1
GAIL/BDA/CNP/AKM/25/W-08
Open Tender
Civil Works
Works
30 days
GAIL RPNHQ
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
MS TEAMS
11 Oct 2025
8 Jul 2025
25 Jul 2025
8 Jul 2025
24 Jul 2025
18 Jul 2025
15 Jul 2025
Amount
Designing, supplying, fabricating and erecting Aluminium composite Panel of 4 mm thickness with exterior grade composed of a low density polythylene core sandwiched between two sheets of aluminium of 0.5 mm thickness ( 0.5+3.0+0.5) the colour shall be beige metallic or other shades as directed at site of work with Eurobond/ Alu bond sheet in combination with other shades and fabricated on hozier machine with necessary sub frame of 40 x 40 x 2 mm with stiffener etc., and fixed on the main frame work made up of specially designed anodised aluminium vertical section of size 112.5 mm x 70 mm x2.5 mm and horizontal section of 82.50 mm x 68.50 mm x 2.5 mm at required at all levels and heights of the proposed building. The aluminium composite panel shall be bent in the tray form to the required sizes and fixed to frame work at wherever required with necessary adapters, cleats, clamps etc., and finished with backer rod, Dow corning 789 weather sealant etc., all as per manufacturer's specifications and as directed at site of work including all labour, materials, bolts and nuts, tools, labour, tools, tackles, lifts, equipments, transportation fuel, etc., complete including necessary suspension piece. Aluminium composite panel cladding with anodized aluminium sections, frame work, sub frame, stiffener, cleats, clamp, adapter, scaffolding etc., complete. Make: Alstone. Panel of approved shade for modification in existing Structure, as required.
Disposal of Rubbish/Dismantled glass upto 5 km to the dumping site
Providing and fixing 10 mm thick solid, UV protected Polycarbonate sheet in Transparent Colour (Make: Bayer/ Lexun/ PRIME) by reusing the existing structure using 60 mm aluminium base profile and aluminium cap profile, (L Cock system), EPDM dome rubber gasket and fixed with high carbon self-drilling screws with washers including providing and fixing anti dust non-woven tape system wherever required with Aluminium/ Polycarbonate edge profile to protect edges all complete as per the specifications (IS CODE- IS 14443 : 1997) Including wastage etc. Including transportation cost. Including cost of scaffolding up to 5 m height. DESIGNATION/CLASSIFICATION of Polycarbonate Sheets is as below: IS PC1SP LHTN 7234 V3 (Finished plan area of Polycarbonate Sheet after installation shall be measured for payment)
Fill the gaps formed during the installation of Polycarbonate sheet in the walls and in the necessary places to prevent water leakage from the newly installed polycarbonate sheet with Silicone Sealant of suitable colour with gun complete in all respects.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .