Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC KANNUR | KERALA | 670001 | L1 | Accepted-AOC ALL DOCUMENTS ARE FOUND CORRECT |
Tender Value
₹12.3 L
EMD Value
₹35,575
Closing Date
27 Feb 2020, 5:00 pmClosed
Assistant Engineer(North)
Assistant Engineer(North) LSGD Engineering wing Thalassery Municipality
ELECRIFICATION,,DIESEL GENERATOR SET AND HIGH MAST LIGHT TO GAS CREMATORIUM BUILDING AT KANDIKAL
2020_LSGD_340129_2
E6-32067-19
Open Tender
Electrical Works
Item Rate
90 days
Thalassery Municipality
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,540
Yes
online
₹35,575
Yes
25 Jan 2023
20 Feb 2020
2 Mar 2020
20 Feb 2020
27 Feb 2020
20 Feb 2020
20 Feb 2020 - 27 Feb 2020
Amount
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FR PVC insulated stranded single core copper conductor cable 650V grade, including providing Switch Board main and continuous earthing with No. 14 SWG copper, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator.
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Independent plug
Supply, conveyance, installation, testing and commissioning of 1200mm 16/20 W LED lamp with box type fixture pre-wired light fittings made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing made from 0.5mmCRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
Supply and fixing angle / straight brass lined skirt type, bakelite batten holder without shade and giving connection etc as required
Supply and fixing 200 mm Plastic sill shade on existing batten / pendent/bracket fittings as required
Supply and providing the7/5 Watta LED Bulb.in the existing fittings as required
Supply and providing Street light fitting with 40 watts LED Street light with asymetirc beam angle 130 x 50 degree with Liminiare efficency more than 85 lm/W rugged aluminium alloy housing, with all accessories complete (OSRAM STRADA Plus 40 W 6500 K,Lumen/watts .80 or equalent make) on existing pipe and giving connection with 24/020 mm 3 core flex wire as required.
Supply, fabrication, conveyance and fixing the 25 mm dia with HG company fabricated clamps of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
40 mm dia GI Pipe (for proction of cable)
Supply and installation of suitable size rod type fan clamp as per IS 732 as required.
Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.
supply and providing LED Gate light 18 Watts (Bajaj make BJCPTI 118 OPAL 160368 or equalent make) on existing pipe and giving connection with 24/020 mm 3 core flex wire as required.
LED Garden light with pole (Philips make model No-15473/30/16-LED 8 watts) or similar make
Supply, conveyance, installation, testing and commissioning of ceiling fans of 1200 mm sweep (Category B)- 5 star rated using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
Charges for cutting holes suitable for accommodating exhaust fans of sizes up to 305 mm sweep including plastering, colour washing etc. as required.
Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.
200 mm, single phase, light duty exhaust fan in plastic body with self opening louvers
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in recess including making good the damages, colour washing etc as required (Group B)
2 module metal box in recess(For Gate light control )
3 module metal box in recess(For power plug )
6 module metal box in recess(For street light ,Garden light)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (Group B)
2 module white/ off-white
3 module white/ off-white
6 module white/ off-white
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)
6 A SP 1 way switch(Street light)
16 A SP 1 way switch with indicator(2 nos for plug ,Gate light,Garden light )
6/16 A combined socket
6 A 3 plate ceiling rose
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required.
20 mm dia light gauge
25 mm dia light gauge
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
1.5 sq mm 3 run( For street light)
1.5 sq mm 4 run( For street light)
2.5 sq mm 3 run( For PP)
4.00 sq mm 2 run( For VDB to 1 phase DB)
4.00 sq mm 4 run( For Control panel)
6.00 sq mm 4 run( COS to VDB )
S & F Enclosures for MCB DB
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
8 way single phase Single cover (IP 42/43) For Cremetorium control panel
12 way single phase double cover (IP 42/43)
4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required
40 A double pole mini break isolator(12 Way DB ,Low Mast)
40 A four pole mini break isolator(Control DB Cremitorium)
40 A, 2 pole, 30 mA RCCB
40 A, 4 pole, 30 mA RCCB
6 A to 40 A, 10 kA, TP MCB (C curve)
6-32A( C curve)
16 A-100a, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.
2.00 mm copper conductor (14 SWG)
2.65 mm copper conductor (12 SWG)
3.15 mm copper conductor (10 SWG)
Supply and laying 25 x 3 mm copper strips and giving connection as required.
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.
2.00/2.65 mm (14 SWG)
3.15 mm (10 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
12 x 3 mm brass bolt & nut
25 x 3mm brass bolt & nut
AC 23 A duty TPN SDF in sheet steel enclosure for DIN /BSfuse
32 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
32/63 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over switch
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
4 core 10 sq mm with factory made clamp
2 core 6 sq mm with factory made clamp(For Gate lights,Low Mast )
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
2 core 6 sq mm
4 core 10 sq mm
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation
40 / 32 mm or nearest size
Supplying siemens / tropodur type nickel plated single compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required.
Supplying and providing earth clamps made out of copper strips of the following sizes including cutting and bending the flat exactly to the shape of the gland, drilling necessary holes for nut & bolt, tinning the points of contacts and giving connections to the main earthing system as required.
4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip
Supply of superior quality aluminium tubular/RING TERMINAL cable socket and making core termination of cables of the following sizes including crimping etc. as required.
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in hard soil)
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required
300 x 300 x 10mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.
2 x 25 x 3 mm GI strip
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 mm GI strip
Fabrication, supply & installation of dust and vermin proof, wall mounting, Sintex make meter box of folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
Supply and fixing the following accessories in the existing meter board and giving connections etc.
BS type fuse units
32 A fuse holder for BS type blade fuses.
2 -80A, DIN type fuse link of size 000
2 Way Neutral link
32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required
2.50 cm, 4 cm or 5 cm height
Supplying and installation of supports, anchor bolts etc made out of suitable size single section MS angle, flats etc as required including painting with 2 coats of synthetic enamel paint( Fixing TPN & Cable tray
Supply and providing M8 anchor bolt hook on wall /parapet for binding support for service main.
Providing suitable size GI Bolt nut with plate/Spring washer for fixing Garden light
Supply and providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength.
Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
Diesel Generator
Supply, Loading, Conveyance, unloading and erection of 40kVA DG set at site as detailed below 15KVA/12KW SILENT Diesel Generating CPCB II approved, in acoustic enclosure comprising of“CUMMINS” Engine Model X1.3TAA-G1 or any other equivalent make of Mahindra, Kirlosker, AshokeLeyland etc. with Radiator Cooled developing 23 BHP, 1500RPM complete with standard accessories, coupled to "Stamford" or eequlant make Alternator rated at 15KVA/12KW at 415 Volts, mounted on Channel Iron Base Frame complete with Fuel Tank of 62 Ltrs capacity with and 1Number 12 V BatteriesWith Standard Manual Control System including suitable Panel and giving connection etc as required.
Supply of HSD for test run
Charges for conducting load test
Earth work excavation in hard soil and depositing with a lead up to 50 m and lift above 1.50 m but up to 3.00 m including neat banking
Cement concrete 1:2:4 using 20mm (nominal size) broken stone for reinforced concrete work.
Plastering with cement mortar 1:4, 12mm thick one coat.
Colour washing, two coats
Cladding For Exhaust System-Supplying and providing cladding for the 150 mm dia nearest size exhaust pipe of the 15 KVA DG set by wrapping 50 mm minaral wool around the pipe,fixing it firmly with in the pipe using chicken mesh,applying over all coating to the system using .040 mm thick aliminium sheet and make it air tight to ensure sound and thermal proof to the system
As above for the silencer of the DG set
Charges towards the preparation of necessary plan, scheme and other related documents
Charges fee for submission to KSELB & KSEB for approvels(Actual amount paid after producing the recepts0
High Mast
Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters (including earthing)
Supply Conveyance, installation, testing and commissioning of 80/100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) (Note:- 2Nos Lamp in one circuit)
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
4 core 1.50 sq mm (including loose for lowering the light bracket)
Supply and fixing class B+C Type surge protection device V25-B+C/1+NPE, 320V 1 Phase Type 1+2 Surge Protection Devices for TT (1+1) systems with potential free contact, thermal disconnector & provisions for inbuilt common remote indication for defective arrestors of OBO/Citel/L&T/Dhen make or similar make including earth connection.
Excavation for foundation in all class of soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Providing and laying in position Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of high mast etc. including form work etc. as required. (Note: The foundation should be 1x1x1.5m below ground level and 0.6x0.6x0.5 above ground level for High mast with 4Nos G.I anchor bolt and nut with washer of length not less than 80cm long and 20mm dia & .45x.45x.6 below ground level for G.I pipe)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_483286.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .