Assistant Engineer (E) EMSD-II, South East, PWD, G
Assistant Engineer (E) EMSD-II, South East, PWD, Giri nagar kalkaji New Delhi
RMO ACs and water coolers installed at Govt. flats at GK 1 PWD office Giri Nagar Labour Court Complex Giri Nagar and CWC VRECs under EMSD II New Delh (SH Servicing comprehensive Maintenance of Air Conditioners and water coolers
2026_PWD_288421_1
152/EE(E)/AE(E)-II/EMD South East/PWD/2025-26
Open Tender
Electrical Works
Percentage
210 days
At Site
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹7,478
Yes
20 Mar 2026
10 Mar 2026
17 Mar 2026
10 Mar 2026
17 Mar 2026
10 Mar 2026
Servicing of existing installed WTAC/STAC of 1.5 TR & 2.0 TR capacity AC and water coolers including cleaning of water tank, checking of unit, greasing, oiling etc. i/c chemical cleaning of condensing & cooling coil with high pressure pump and cleaning of tank of water cooler, changing the air filter, checked & tightening all electric connections, testing the machine etc. as reqd.
Supply & Charging R-22/410/407/32/134a gas in the existing WTAC/STAC of 1.5/2.0 TR unit and water coolers i/c pressure testing, flushing the system and Gas Charging complete as reqd.
Supplying & Fixing 25 mm diameter PVC heavy duty pipe for drainage in the existing split type AC unit with supporting clamps etc . complete as reqd.
Supplying and fixing of Extra copper refrigerant piping of 5/8”, 3/8”, 1/4” i/c nitrile rubber insulation wrapping etc. complete as reqd.
Providing and fixing of 4 core 2.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable for communication between indoor unit/outdoor unit/controllers inside building in existing steel/PVC Conduit/ surface/ existing channel, i/c making connection etc as reqd.
Replacement of following capacity compressor in the existing WTAC/Split AC with new one and making copper pipe connection, brazing pressure testing and supplying and charging refrigerant gas i/c cutting the copper piping dismantling of the old compressor complete as Reqd.
1.5 TR capacity
2 TR capacity
Supplying and replacement of wornout/defective copper condensor coil with new one in same size of design suitable for following capacity split type AC out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd.
a) 1.5TR capacity
b) 2 TR capacity
Supplying and replacement of wornout/defective copper cooling coil with new one in same size of design suitable for following capacity split type AC out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd.
a) 1.5TR capacity
Repairing of inverter PCB in existing indoor/outdoor unit complete etc as reqd.
Supplying And Replacement of inverter PCB in existing indoor/outdoor unit complete Installation, Testing etc as reqd.
Supplying And Replacement of Fan Motor with fan Blade in existing WTAC/STAC of 1.5/2.0 TR unit AC i/c connection, Testing etc required.
Dismantling, shifting and reinstallating of existing 1.5TR/ 2.0TR capacity STAC (indoor and outdoor unit) including repairing the damaged caused due to dismantling within same office etc as required.
Credit for dismantle material
a) Compressor 1.5TR/ 2TR
b) Refrigerant copper pipe / Cu wire with insulation
c) 4 core 2.5sqmm wire with insulation
e) Condenser coil
f) Cooling Coil
stage.html
html • 0.04 MB
technical_382525.pdf
techsummary_382525.pdf
finance_382525.pdf
fin_eval.pdf
cancelled_1.pdf
pdf • 0.27 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.56 MB
BOQ.xls
Tender Documents • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .