Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹30.3 L Quoted ₹31.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹32.6 LRejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | ₹32.6 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹38.4 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹38.4 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹40.9 LRejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR PIN 361 005 | JAMNAGAR | GUJARAT | 361005 | ₹40.9 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹40.9 LRejected-Finance | ₹40.9 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | JAYESH TRADING CORPORATION L1 | Ravi enterprise L4 | M/s.Bhavin Electricals L6 | JAMNAGAR ELECTRIC AND MACHINERY CO L11 | Sagar Builders L10 | M/s Jagdish Machinery Stores L8 | J J ENTERPRISE L5 | BHAVNA IMPERIAL ENTERPRISE L3 | M/s Balaji Enterprise L2 | 1R K Traders L9 | MADHAV ENTERPRISE L12 | Hirachand Sunderji and co L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for maintenance of Automatic Transfer Switch (ATS) of rating up to 630 Amp of Make Havells/ Legrand/ L&T complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and disconnecting incoming and outgoing connections, refixing the same after complete maintenance, replacement of fuses, tripping mechanism, tripping coils, pole assembly, control unit, auxiliary switch, incoming and outgoing connections and replacement of overheated/ faulty portion of control circuit wiring as per above mentioned make as and when as directed by Engineer-in-Charge.
Notes : (i) Necessary spare parts required replacement shall be replaced only after prior inspection & approval of Engineer-in-Charge. (ii) Spares required for repairing/ servicing of ATS shall be measured and paid for separately as ‘Supply only’ under relevant items of this Schedule 'A' (BoQ). (iii) Fixing rate of the spares including testing is deemed to be inclusive in quoted rate of this item. (iv) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. | 25 | Each Job | 3,000 ₹75,000 | 2,900 ₹72,500 | 2,200 ₹55,000 | 5,121 ₹1.3 L | 4,700 ₹1.2 L | 4,890 ₹1.2 L | 6,000 ₹1.5 L | 2,500 ₹62,500 | 1,500 ₹37,500 | 4,700 ₹1.2 L | 4,900 ₹1.2 L | 4,440 ₹1.1 L |
| 2.00 | Supply only Closing Coil for ATS upto 630 Amp, 4 pole as per existing make. | 6 | Each | 3,300 ₹19,800 | 3,800 ₹22,800 | 3,400 ₹20,400 | 6,061 ₹36,366 | 6,100 ₹36,600 | 4,200 ₹25,200 | 7,000 ₹42,000 | 3,180 ₹19,080 | 2,400 ₹14,400 | 6,100 ₹36,600 | 6,200 ₹37,200 | 5,550 ₹33,300 |
| 3.00 | Supply only Control unit for ATS upto 630 Amp, 4 pole, as per existing make. | 4 | Each | 13,000 ₹52,000 | 17,500 ₹70,000 | 21,000 ₹84,000 | 28,006 ₹1.1 L | 25,400 ₹1.0 L | 22,000 ₹88,000 | 36,000 ₹1.4 L | 16,000 ₹64,000 | 15,000 ₹60,000 | 24,700 ₹98,800 | 26,400 ₹1.1 L | 23,000 ₹92,000 |
| 4.00 | Supply only Trip coil of assy for ATS of rating upto 630 Amp as per existing make. | 6 | Each | 400 ₹2,400 | 900 ₹5,400 | 700 ₹4,200 | 1,306 ₹7,836 | 2,250 ₹13,500 | 600 ₹3,600 | 1,500 ₹9,000 | 680 ₹4,080 | 551 ₹3,306 | 3,450 ₹20,700 | 2,350 ₹14,100 | 880 ₹5,280 |
| 5.00 | Supply only Auxiliary switch for ATS of rating upto 630 Amp as per existing make. | 6 | Each | 1,100 ₹6,600 | 1,000 ₹6,000 | 800 ₹4,800 | 2,153 ₹12,918 | 3,500 ₹21,000 | 500 ₹3,000 | 3,500 ₹21,000 | 840 ₹5,040 | 350 ₹2,100 | 2,260 ₹13,560 | 3,550 ₹21,300 | 1,220 ₹7,320 |
| 6.00 | Supply only Pole assembly for ATS of rating upto 200 Amp as per existing make. | 4 | Each | 4,900 ₹19,600 | 6,000 ₹24,000 | 5,500 ₹22,000 | 8,203 ₹32,812 | 8,100 ₹32,400 | 3,950 ₹15,800 | 4,500 ₹18,000 | 4,700 ₹18,800 | 2,200 ₹8,800 | 7,900 ₹31,600 | 8,900 ₹35,600 | 4,880 ₹19,520 |
| 7.00 | Supply only Pole assembly for ATS of rating 315 Amp as per existing make. | 5 | Each | 7,900 ₹39,500 | 8,500 ₹42,500 | 7,000 ₹35,000 | 11,286 ₹56,430 | 12,400 ₹62,000 | 7,654 ₹38,270 | 6,200 ₹31,000 | 6,600 ₹33,000 | 3,500 ₹17,500 | 9,800 ₹49,000 | 12,500 ₹62,500 | 7,770 ₹38,850 |
| 8.00 | Supply only Pole assembly for ATS of rating 400 Amp as per existing make. | 6 | Each | 9,000 ₹54,000 | 13,500 ₹81,000 | 11,000 ₹66,000 | 16,093 ₹96,558 | 14,800 ₹88,800 | 8,654 ₹51,924 | 10,500 ₹63,000 | 11,000 ₹66,000 | 5,200 ₹31,200 | 11,400 ₹68,400 | 15,400 ₹92,400 | 9,770 ₹58,620 |
| 9.00 | Supply only Pole assembly for ATS of rating 630 Amp as per existing make. | 6 | Each | 12,000 ₹72,000 | 14,500 ₹87,000 | 12,500 ₹75,000 | 20,472 ₹1.2 L | 18,700 ₹1.1 L | 9,865 ₹59,190 | 12,000 ₹72,000 | 12,000 ₹72,000 | 6,300 ₹37,800 | 13,900 ₹83,400 | 19,400 ₹1.2 L | 13,030 ₹78,180 |
| 10.00 | M&L for servicing and repair to HT oil switch of size upto 630 Amp complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and opening the Oil chamber of HT switch gear and cleaning the contacts, put the fuse in position and testing complete all as specified and as directed by Engineer-in-Charge. | 10 | Each Job | 3,000 ₹30,000 | 4,000 ₹40,000 | 3,000 ₹30,000 | 5,016 ₹50,160 | 4,900 ₹49,000 | 13,500 ₹1.4 L | 22,000 ₹2.2 L | 2,800 ₹28,000 | 2,200 ₹22,000 | 5,100 ₹51,000 | 5,100 ₹51,000 | 3,330 ₹33,300 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Apr 2026, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar
Repairs/ replacement and maintenance of LT ACB, ATS, APFC Panels and Servo Stabilizers at INS Valsura, Jamnagar
2026_MES_757150_1
8938/VAL/E8
Open Tender
Electrical and Maintenance Works
335 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹80,000
Yes
20 Apr 2026
20 Mar 2026
10 Apr 2026
20 Mar 2026
8 Apr 2026
3 Apr 2026
Supply only Closing Coil for ATS upto 630 Amp, 4 pole as per existing make.
Supply only Control unit for ATS upto 630 Amp, 4 pole, as per existing make.
Supply only Trip coil of assy for ATS of rating upto 630 Amp as per existing make.
Supply only Auxiliary switch for ATS of rating upto 630 Amp as per existing make.
Supply only Pole assembly for ATS of rating upto 200 Amp as per existing make.
Supply only Pole assembly for ATS of rating 315 Amp as per existing make.
Supply only Pole assembly for ATS of rating 400 Amp as per existing make.
Supply only Pole assembly for ATS of rating 630 Amp as per existing make.
M&L for servicing and repair to HT oil switch of size upto 630 Amp complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and opening the Oil chamber of HT switch gear and cleaning the contacts, put the fuse in position and testing complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs HT HRC type fuse, rating 40/63 Amp of HT Oil Switch complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and opening the Oil chamber of HT switch gear and cleaning the contacts put the fuse in position and testing complete all as specified and as directed by Engineer-in-Charge. Make: L&T/ Bussmann/ CG Lucy or equivalent as approved by GE.
M&L for servicing of LT ACB of rating up to 630 Amp, 415 Volt, 50 Hz of any make complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and cleaning the ACB by using air blower, tightening of connection of control circuit and complete checking of all fuses and control circuit for smooth functioning by employing one skilled tradesman as and when required including consisting of following :- (a) Checking the control circuit wiring and rectifying the same with new rewiring with proper size and colour code where required at site. (b) Checking the components for replacement such as Shunt release, UV release, ammeter, voltmeter, etc. c) Resetting and testing of relay setting for proper functioning.
S&F in repair copper bus bar of rating as per required at site, with supporting insulator duly fitted in PVC insulated sleeve in existing panel with requisite in shape and size required at site for fixing the bus bar at existing panel complete all as specified and directed by Engineer-in-Charge.
S&F in repair 1100 Volt grade flexible single core cable with tinned copper stranded conductor PVC insulated and sheathed of cross sectional area 240 Sqmm (ISI marked) including copper lugs at both ends and all accessories required as per the site requirement including testing on completion complete all as specified and as directed.
All as per serial item No. 14 here-in-above, but cross-sectional area 185 Sqmm.
All as per serial item No. 14 here-in-above, but cross-sectional area 16 Sqmm.
All as per serial item No. 14 here-in-above, but cross-sectional area 10 Sqmm.
All as per serial item No. 14 here-in-above, but cross-sectional area 2.5 Sqmm.
M&L for CTs of required ratio from 100/5 to 800/5 in replacement in existing feeder pillar box and connect terminals to APFC panel and testing on completion complete all as specified & as directed.
S&F in repair Capacitor duty contactors, 3 pole, 230/415 V, 50 Hz of type MO C5 with auxiliary contacts for upto 5 kVAR rating complete all as specified & as directed. Make : L&T/C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Capacitor duty contactors, 3 pole, 230/415 V, 50 Hz of type MO C12.5 with auxiliary contacts for upto 12.5 kVAR rating complete all as specified & as directed. Make : L&T/C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Capacitor duty contactors, 3 pole, 230/415 V, 50 Hz of type MO C15 with auxiliary contacts for upto 15 kVAR rating complete all as specified & as directed. Make : L&T/C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Capacitor duty contactors, 3 pole, 230/415 V, 50 Hz of type MO C25 with auxiliary contacts for upto 25 kVAR rating complete all as specified & as directed. Make : L&T/C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair 6-stage APFC relay with built in P.F Meter complete all as directed. Make : L&T/C&S/HPL or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair 8-stage APFC relay with built in P.F Meter complete all as directed. Make : L&T/C&S/HPL or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
S&F in repairs MCB TPN 32 Amp, 415 V, 50 Hz, AC supply, 10 kA, 'C' Curve, with proper size lugs complete all as directed.
S&F in repairs MCB TPN 40 to 63 Amp, 415 V, 50 Hz, AC supply, 10kA, 'C' Curve, complete all as directed.
S&F in repair Power factor improvement Capacitor banks, Cylindrical type, 3 phase, 440 V, Heavy duty of as per required at site from 5 to 25 kVAR LTCCR super heavy duty type capacitor complete all as directed. Make : L&T / EPCOS/ C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair R/Y/B phase Indicator lamps LED type complete all as directed.
S&F in repair 3 Pole Power Contactor, 40 Amp AC3 rating, 2 NO + 2 NC, including necessary connections for incoming and outgoing complete all as directed. Make : L&T ‘Type ML 3’ Cat No. SS90721 or equivalent in makes mentioned in Appendix 'B' here-in-after.
All as per serial item No. 33 here-in-above, but Servo stabilizer transformer of capacity 15 to 50 kVA.
Supply only Control push buttons/ switches/ fuse carriers/ knobs etc for Servo stabilizers transformer.
Rewinding of coils all as per its original specifications by new copper conductor and with necessary insulation materials for Servo stabilizers transformer.
Supply only LT bushing assembly with brass terminal, neoprene rubber gasket and washers etc complete with accessories for Servo stabilizers transformer.
Supply and filling new Transformer oil up to conservator level marking as per IS-335 having dielectric strength not less than 40 kV at 2.5mm gap complete all as specified and as directed. Make : Electrol, Power Oil, Indian Oil, Savita or equivalent as approved by GE.
Supply only Servo control motor as per existing model for controlling the voltage for Servo stabilizers transformer.
Supply only Cork/ Neoprene rubber Gasket set complete for Servo stabilizers transformer.
Supply only PCB for Servo controlled voltage stabilizers as per existing model and make or equivalent model and make as approved by GE.
M&L for preparation of old painted external surfaces of floor mounted indoor/outdoor type Stabilizer from 100 KVA to 300 KVA capacity by cleaning/ rubbing with course cloth, wire brushes, etc to remove dust deposits, oil, grease, etc and painting by applying one coat of synthetic enamel paint (first quality) of approved tint with gun sprayer without disturbing/ damaging the electrical network system/ equipment including marking of capacity, rating, incoming, outgoing & SM/MES No, etc details in capital English alphabets of suitable size with synthetic enamel paint (white) complete all as specified and as directed.
M&L for filtration / dehydration of old/existing transformer oil including topping up of transformer oil as required in the Servo stabilizer transformers of different capacity, installed at various locations with suitable capacity of filtration machine to achieve dielectric strength minimum 60 KV complete all as specified and as directed. Notes: (i) All necessary T&P / testing equipment shall be provided by the contractor at his own cost. No extra payment shall be made to the contractor. (ii) New Transformer Oil required for topping up shall be paid for separately under relevant item of this Schedule.
S&F in repair MCCB with thermal magnetic protection unit rating 630 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4220 09 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair MCCB with thermal magnetic protection unit rating 400 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4220 07 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair MCCB with thermal magnetic protection unit rating 250 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4202 49 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair MCCB with thermal magnetic protection unit rating 160 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4200 97 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Automatic Transfer Switch (ATS) 630 Amp, 4 Pole with controller, 415 V, 50 Hz, Open Execution, complete all as specified and as directed. Make: Havells Cat No. IHYFCDO630 or equivalent in L&T/ABB/other makes mentioned in Appendix 'B' here-in-after.
S&F in repair Automatic Transfer Switch (ATS) 400 Amp, 4 Pole with controller, 415 V, 50 Hz, Open Execution, complete all as specified and as directed. Make: Havells Cat No. IHYFCDO400 or equivalent in L&T/ABB/other makes mentioned in Appendix 'B' here-in-after.
S&F in repair Automatic Transfer Switch (ATS) 200 Amp, 4 Pole with controller, 415 V, 50 Hz, Open Execution, complete all as specified and as directed. Make: Havells Cat No. IHYFCDO200 or equivalent in L&T/ABB/other makes mentioned in Appendix 'B' here-in-after.
S&F in repair Multifunction meter of 96x96 mm size, flush mounting, complete with digital display, LED showing Voltage, current, PF, Frequency, electrical parameters complete all as specified and as directed. Make: L&T Cat No. WL411010OOOO or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Air Circuit Breaker (ACB), 630 Amp, 4 Pole, 50 kA, drawout version, single frame, manual and electrical Versions, including advanced self powered electronic protection units and shunt coil, close coil, working on 220-250 V AC, Neutral Overload protection OFF-50%-100%, inbuilt temperature protection, LCD Display, Real terminals - vertical or horizontal connection with bars to be fixed onto plate-4P, fast operation type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition/ alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make : Legrand ‘ACB : Cat No 6695 42’, ‘Electronic Protection Unit : Cat No 0281 67’ & ‘Real terminals : Cat No. 0288 97’ or equivalent in makes mentioned in Appendix 'B' here-in-after.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, base of columns etc., basement slabs, under-reamed piles and mass concrete including necessary formwork complete all as specified and as directed. Note: Reinforcement shall be measured and paid for separately.
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’, fixed in repairs, complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed.
Dismantling and taking down existing damaged/broken PCC Pole and S&F new 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 Amp, 240 V, 10 kA, 'C' Curve (1 No.), MCB TP 32 Amp, 415 V, 10 kA, 'C' Curve (1 No.) & Connector (RYB&N) - 63 A Cap (01 No.) complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-6030 (BOPH-6030) or equivalent in makes mentioned in Appendix 'B' here-in-after. Note: Earth work and PCC foundation shall be measured & paid for separately.
Disconnecting, dismantling & taking down old unserviceable Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new outdoor type LT Timer Switch Panel Box cubical type of suitable size (minimum depth 500mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 3.15 mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet, with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, outdoor type, totally enclosed, weather, dust and vermin proof as per IS, Front & Rear opening with double door shutters having suitable aldrop bolt locking arrangement, with insulators, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 45cm above ground level and 30cm below ground level, comprising & including the following accessories complete all as specified and as directed :- (a) MCB, Four Pole, 63 Amp, 415 V, 50 Hz, AC supply, 10kA, 'C' Curve - 01 No. as incoming. description of item contd....
S&F in repairs 2.50 Sqmm 3 core PVC insulated, PVC Sheathed, multistranded copper conductor flexible cable of 1100 Volt grade (ISI marked) drawn through existing conduit pipe/ inside GI Pole from DB, Junction Box, etc to fitting with suitable lugs etc complete all as specified & as directed.
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
S&F in repairs 10mm thick chequered type insulating electrical rubber mat of size 4 x 8 ft (ISI Marked) complete all as specified & as directed.
M&L for galvanised iron strip 25 x 4mm earth continuity conductor or main earthing lead buried in ground / fixed on wall with suitable porcelain insulators including taking out existing GI strip complete all as specified and as directed.
M&L for galvanised iron strip 32 x 6mm earth continuity conductor or main earthing lead buried in ground / fixed on wall/ Pole including taking out existing GI strip complete all as specified and as directed.
S&F in repair copper strip 20mm x 3.15mm complete with saddles and fixing screws for fitting the strip or fixing with & including suitable porcelain insulators, complete all as specified & as directed.
M&L for Earthing with & including copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including copper strip 20 x 3.15mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, Copper earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing of any type.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing.
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
technical_848105.pdf
techsummary_848105.pdf
finance_848105.pdf
BOQ Comparative Chart
xlsx
finsummary_848105.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
8938TENDER.pdf
Tender Documents • 1.10 MB
BOQ_848105.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid