Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.8 LAccepted-AOC | 1 | Accepted-AOC Being L1 | |
| 2 | 2₹15.9 L+₹75,649.82 (4.99%)Rejected-AOC | 2 | Rejected-AOC Being L2 | |
| 3 | 3₹17.4 L+₹2.3 L (14.9%)Rejected-AOC | 3 | Rejected-AOC Being L3 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Sept 2023, 6:00 pmClosed
CWE YOL
HQ CWE YOL
REPAIR / REPLACEMENT OF UNSERVICEABLE STREET/ SECURITY LIGHT, TIMERS, CENTRALIZED SWITCHING OF STREET AND SECURITY LIGHTS ALONG WITH OTHER ALLIED WORKS AT MIL STN DHARAMSALA
2023_MES_614392_1
CWE/Y-49/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DHARAMSHALA
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) DHARAMSHALA
₹50,000
Yes
7 Nov 2023
21 Aug 2023
27 Sept 2023
21 Aug 2023
20 Sept 2023
6 Sept 2023
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard and dense soil, complete all as specified and directed.
All as per Srl Item No 1.00 above but depth exceeding 1.5 mtr and not exceeding 3.0 mtr.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar ands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork where required complete all as specified and directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed.
Renewal of mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 50mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
Renewal of mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 40mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts (Earthed), grade cross sectional area 25 sqmm 3.5 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts (Earthed), grade cross sectional area 16 sqmm 4 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts (Earthed), grade cross sectional area 10 sqmm 2 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
SMC cable junction box of size 140x140x95mm suitable for street light/PTL, square type , weather proof , IP-54 including fixing of 10Amp MCB SP and clamps , nuts , bolts , washers suitable for fixing to pole/GI pipes including suitable arrangement for cable entry and exit with 2 run of 1.5 sqmm FRLS flexible cable laying through PVC conduit from junction box to street light fitting complete all as specified and directed. Make : Sintex Cat Part No. GSJB1414 or its equivalent approved make.
Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 25/30/36 Watt all as per sample held in GE Office complete all as directed.
Supply and fix in replacement of existing unserviceable driver for post top lantern LED fitting of capacity 40/45 Watt all as per sample held in GE Office complete all as directed.
Supply and fix in replacement of existing unserviceable driver for post top lantern LED fitting of capacity 60 to 75 watt Watt all as per sample held in GE Office complete all as directed.
Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 100 to 120 Watt all as per sample held in GE Office complete all as directed.
Supply and fix in replacement post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including necessary electric connection and testing complete all as specified and directed.
Supply and fix in replacement post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including necessary electric connection and testing complete all as specified and directed.
Cutting of existing road/ floor/ plinth/drain for taking out/laying of UG cable through GI pipe including necessary earth work excavation and making good to match with existing surface complete all as specified with PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) complete all as specified.
Painting to existing steel tubular HT/LT poles, 11m/9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed
Supply and fix in replacement of existing unserviceable SVL/HPSV fitting with New generation energy saving and environmental friendly long life LED street light 35 Watt made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with 10KV built in surge protection device including GI bracket of 32/40mm dia, 1.5 mtr long bent to any shape required as per site and making neccessry connection with 2.5 sqmm copper wire from fitting to pole box all as directed by Engr-in- Charge. Havell's Cat Part No. ENDURASUNDOWNSL35WLED765PASYBOPC of "Havells" or equivalent in makes mentioned in Appendix
Supply and fix in replacement of existing unserviceable SVL/HPSV fitting with New generation energy saving and environmental friendly long life LED street light 60 Watt, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device including GI bracket of 32/40mm dia, 1.5 mtr long bent to any shape required as per site and making neccessry connection with 2.5 sqmm copper wire from fitting to pole box all as directed by Engr-in- Charge. Make: Havell's Cat Part No. ENDURASUNDOWNSL60WLED765PASYBOTG of "Havells" or equivalent in makes mentioned in Appendix
Supply and fix in replacement of existing unserviceable fitting with new LED flood light 70 watt 230 V ,AC outdoor Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting complete with driver and lamp and making neccessry connection with 2.5 sqmm copper wire complete all as directed by Engr-in- Charge. Make: Havell's Cat Part No. JETAALBAFLOODLIGHT70W of "Havells" or equivalent in makes mentioned in Appendix
Supply and fix in replacement of existing unserviceable fitting with new LED flood light 120 watt 230 V ,AC outdoor type Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting. complete with driver and lamp and making neccessry connection with 2.5 sqmm copper wire complete all as directed by Engr-in- Charge. Make: Havell's Cat Part No. JETAIRISFL120WLED757APWBLTG of "Havells" or equivalent in makes mentioned in Appendix
Supply and fix in replacement of existing unserviceable PTL fitting with 45 watt Circular LED post-top offering excellent uniform illumination and aesthetics in one go. Made up of Pressure Die Cast aluminium body and opal PC cover. IP 66 and IK 07 rating ensures it stands tall amid varied environmental conditions. and making neccessry connection with 2.5 sqmm copper wire from fitting to pole box all as directed by Engr-in- Charge. Make: Havell's Cat Part No. RINKPT45WLED757PSYMTOPC of "Havells" or equivalent in makes mentioned in Appendix
Aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish, Compatible for all post top range., Circular base of height 3 metre bottom dia 130mm and top dia 76mm , fixed in poistion with nuts , bots and washers as required at site including necessary excavation and PCC 1:3:6 , fixed in repair , all as directed by Engr-in- Charge. Make: Havell's Cat Part No. ECO POLE 3M TOP of "Havells" or equivalent in makes mentioned in Appendix
Supply and fix in replacement of existing unserviceable fitting with 8 watt Cone NXG series acts as an imposing street furniture with touch of aesthetic. Innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landscape environment with robust IP 65 rating. ,fixed in poistion with nuts , bots and washers as required at site including necessary excavation and PCC 1:3:6 all as directed by Engr-in- Charge. Make: Havell's Cat Part No. CONENXGBLS8WLEDPSYM830TOPC of "Havells" or equivalent in makes mentioned in Appendix
NG Series AIO Solar Street Light , 30 watt, made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & is specially progrmmed to automatically control the dimming and brightness of light, with and including EROS casting pole 3 metre high, Make : Havell's Cat Part No. SOLAR AIO 30 W or equivalent in makes mentioned in Appx
Supply and fix in replacement GI bracket of 32 mm dia, 1.5 mtr long, bent to any shape suitable for LED street Light complete with nuts, bolts and washers required as per site to fix in poistion complete all as directed by Engr-in- Charge.
Cutting/ trimming of trees branches from LT/ HT lines upto 2 metre horizontal & 2 metre vertical distance from both sides of electric line including shifting of cut trees branches away from site complete all as directed. Note:- Distance between two adjacent poles irrespective of distance shall be considered as one span.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC including taking down old pole of any type shape, size and removing from site complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-55 (11m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC including taking down old pole of any type shape, size and removing from site complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
Galvanized steel wire 4mm dia for earth wire/ guard wire onHT/ LT poles stretched without kinks, bend and binding with wire including fabrication of cradles hexagonal/ rectangular guards, spacers, road crossing etc., including taking down old wire of any type shape , size and removing from site, complete all as specified & directed .
Supply , fixing and straining of Aluminum conductor steel reinforced (ACSR) of any size on HT/LT over head line including necessary binding work, jumpering, maintaining proper sag as per IE rule including cutting of tree branches around the ACSR conductor within area of 5mtr complete all as specified & directed
Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer including preparation of surfaces and dismantling old structural steel work in cross arms and stacking at site, complete all as specified & directed.
Stay Assembly using stay rod of 20mm dia complete with accessories as shown in Electrical Plate No. 1 of SSR 2009 Part-I including galvanized steel stranded wire of size 7/4mm and taking out/ dismantling old stay assembly, complete all as specified (Loop type insulator, earth work and PCC shall be measured and paid for separately under respective items of BOQ)
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 90x140mm, clearance of hole 25.5 mm, complete all as specified and directed.
Renewal of Shackle type porcelain vitreous white, brown or green insulator working pressure 1100 Volts of 90mm dia 75mm height including galvanized mild steel strip of size 31x3mm ,size 12mm dia insulator bolt,washers and nuts complete all as apecified.
Supply and fix in replacement of existing unserviceable digital/auto/manual time switch with all fittings all as per sample held in GE Office complete all as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 23 of tender doucments.
JAI DURGA CONSTRUCTION CO
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .