| 1 | L1₹21.6 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹22.9 L+₹1.4 L (6.37%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Proper Experience Cert not Attached |
Tender Value
₹23 L
EMD Value
₹23,000
Closing Date
25 Oct 2023, 9:00 amClosed
Se EDC-I Azamgarh
Se office EDC-I Hydel Colony Sidhari Azamgarh
Construction of 33 KV Line and Maintenance Under EDD-I Azamgarh
2023_PVVNV_848079_2
78/EDC-1(A)/2023-24
Open Tender
Electrical Works
Item Rate
120 days
EDC-I Azamgarh
See Term and Condition
2 documents required · 2 mandatory
₹3,540
EE ETD-1 Azamgarh
₹23,000
4 Nov 2023
16 Oct 2023
25 Oct 2023
16 Oct 2023
25 Oct 2023
16 Oct 2023
16 Oct 2023 - 25 Oct 2023
Amount
fo|qr forj.k [k.M&f}rh; ds vUrxZr 33@11 dsoh midsUnzksa ds lqn`<+hdj.k] lECfU/kr dk;Z o vU; dk;Z ¼fctusl Iyku o"kZ 2023&24 ftyk ;kstuk&20 djksM+ ½
Servicing of 33 KV VCB of the work Involves complet cheching of Operation of Mechanism, Minor repairing and Replacement of faulty Parts and Lubrication of Mechanism, Proper Adjustment/Alignment of Tripping & Closing Lever of breaker for smooth Operation in EDD-II, Azamgarh. (In recpect of 14 Nos. 33/11 KV sub-station).
Proper Testing of 33 KV VCB Local & Remote Mode Operation With Inter Locking, I.R. Valule Test. Closing & Tripping Time. Static Contact Resistance Measurement Test, etc.
Proper Wiring Work of 33 KV Control Relay Panel Wiring for Local & Remote Mode Closing & Tripping Operation with Protection Like. C.T/P.T to CRP. 33 KV VCB to CRR. Power Transformer to CRP.
Proper Testing Work of 33 KV Protection Relay of Over Current & Earth Fault, WTI, OTI, Ampere Meter, volt meter, Buchholz etc. With Master Relay 86 Inter Loking, Through Secondary Injection Test etc.
The Complete Work of Wiring of Transformer Protection of 33 KV Control Relay Panel to Power Transformenr Like. WTI-Tripping & Alarm, OTI-Tripping & Alarm, Buchholz Relay-Tripping & Alarm MOG-Tripping & Alarm, PRV/PSR-Tripping & Alarm. Etc.
Eraction, Commisining and testing of CT, PT Juction Box with providing Clamp By Contractor.
Laying of Control Cable and jointing in control pannel with proper Ferrul and proper Testing.
Eraction, Commisining and testing of New 33 kv control pannel and including carrige of 33 kv control pannel from store to work site.
fo|qr forj.k [k.M&izzFke ds vUrxZr ,y0Vh0 ykbZu ij ttZj rkj cnyuk o vU; dk;Z½ ¼;kstuk&62 vfrfjDr fctusl Iyku½
Supply of Over Current & Earth Fault Protection Relay. Make: Ashida make
Supply of Power Transformer Protection Annunciator Panel for O/D protective devices and Relays. Suitable for : Ashida/Alstom/Areva.
Supply of WTI Meter for Alarm & Tripping for Power Transformer Protection.
Supply of OTI Meter for Alarm & Tripping for Power Transformer Protection.
Supply of Master Trip Relay for Alarm & Tripping for Power Protection. Make: Ashida/Alstom/Areva.
Supply of Control Cable of 2.5 sqr. Mm With Armoured 10 Core for 33 KV C.T. to CRP Meetring & Protaction Wiring.
Supply of Control Cable of 2.5 sqr. mm With Armoured 4 Core for 33 KV C.T. to CRP Meetring & Protaction Wiring.
Supply of Control Cable of 2.5 sqr. mm With Armoured 2 Core for 33 KV C.T. to CRP Meetring & Protaction Wiring.
Ampere Meter and Voltmeter (Digital) suitable for CRP
New 33 KV CRP Panel
PVC tape RYB and Black and HT Tape and Empire Tape
Feyrule , link and wire fixures
Supply of copper flexible PVC 2.5 sqr. mm suitable for CRP Metering & Protaction Wiring. Of RYB and black Colors
Supply of Current Transformer Juction Box 33 KV CT to CRP Metering & Protaction Wiring.
M/S CHANDRA CONSTRUCTION, VILL- CHALAKPUR, POST- CHANDPATTI, SAGARI, AZAMGARH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .