| 3 | L3₹16.4 L+₹2.4 L (17.1%)Rejected-Finance 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹18.3 L+₹4.3 L (30.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹18.6 L+₹4.6 L (32.7%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
8 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D Chandigarh
DIHAR Base Lab, Near 3 BRD (AF), Industrial Area Phase-II, Ramdarbar, Chandigarh
REPAIR / REPLACEMENT OF DISTRIBUTION BOARDS, MAIN SWITCHES AT VARIOUS ZONE IN TBRL RANGE RAMGARH
2020_MES_398539_1
GE I R AND D/CHD-64/2020-21
Open Tender
Civil Works
Item Rate
180 days
Ramgarh
All as per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹58,000
Yes
15 Jan 2021
11 Dec 2020
11 Jan 2021
11 Dec 2020
8 Jan 2021
25 Dec 2020
60 days
Amount
Taking down the existing unserviceable main switches/DBs any type including boards from its position and making the good of disturbed surface complete all as directed.
Taking down carefully by sub main wiring/service connection of any type complete all as specifed and directed.
Material and labour for wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in Concealed/surface as required using sizes of 2x1.5 Sqmm+1x1.5 Sqmm earth wire cables inciuding in PVC conduit/casing caping.
All as per serial item No 3.00 above but 2x2.5 Sqmm+1x2.5 Sqmm earth wire.
All as per serial item No 3.00 above but 2x4.0 Sqmm+1x4 Sqmm earth wire.
All as per serial item No 3.00 above but 2x6.0 Sqmm+1x6 Sqmm earth wire.
All as per serial item No 3.00 above but 2x10 sqmm+1x 10Sqmm earth wire.
All as per serial item No 3.00 above but 4x10 sqmm+1x10 Sqmm earth wire.
All as per serial item No 3.00 above but 4x16 sqmm+1x16 Sqmm earth wire.
All as per serial item No 3.00 above but 4x25 sqmm+2x16 Sqmm earth wire.
Supply and fixing/laying in any position with fixing arrangement XLPE Insulated, PVC bedded, armoured, electric power LT UG cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core with lugs, thimbles and testing after laying complete all as specified and directed.
Supplying and fix in repair Tempra plug & socket DB and MCBs, triple pole and neutral enclouser with a Four pin and earth plug and socket complete with one TPN MCB , 440V of capacity 32 amps of complete all as specified and directed by Engineer-in-Charge.
Supplying and fix in repair Tempra plug & socket DB and MCBs, triple pole and neutral enclouser with a Four pin and earth plug and socket complete with one TPN MCB , 440V of capacity 63 amps of complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing for sheet metal enclosure for DBs when MCBs to be used single pole and neutral with IP 43 protection, 240 volt with 200 amps rated bus bar bar 4 way of incl necessary fixing arrangement and all incoming and outgoing electric connection all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used single pole and neutral with IP 43 protection, 240 volt with 200 amps rated bus bar bar 8 way of incl necessary fixing arrangement and all incoming and outgoing electric connection all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used single pole and neutral with IP 43 protection, 240 volt with 200 amps rated bus bar bar 12 way of incl necessary fixing arrangement and all incoming and outgoing electric connection all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used single pole and neutral with IP 43 protection, 240 volt with 200 amps rated bus bar bar 16 way of incl necessary fixing arrangement and all incoming and outgoing electric connection all as specified and directed by Engr-in-Charge.
Supply and fix in repairs Sheet metal enclosure for DB’s TPN, with 200 amps rated bus bar , 4 way, 415 volts double door surface/reccess mounting including connection with the existing sub circutis, electric meter etc with proper size new copper cable, lugs,connectors etc all as specified and directed by Engr-in-Charge.
Supply and fix in repairs Sheet metal enclosure for DB’s TPN, with 200 amps rated bus bar , 6 way, 415 volts double door surface/reccess mounting including connection with the existing sub circutis, electric meter etc with proper size new copper cable, lugs,connectors etc all as specified and directed by Engr-in-Charge.
Supply and fix in repairs Sheet metal enclosure for DB’s TPN, with 200 amps rated bus bar , 8 way, 415 volts double door surface/reccess mounting including connection with the existing sub circutis, electric meter etc with proper size new copper cable, lugs,connectors etc all as specified and directed by Engr-in-Charge.
Supply and fix in repairs sheet metal enclouser distribution board 415volt,Vertical TPN 4 Way with provision for suitable MCCB FP up to 125 A as incomer & MCBs SP/TP as out going as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 protection, , including connection with the existing sub circutis, electric meter etc with proper size new copper cable, lugs, connectors etc all as specified and directed by Engr-in-Charge.
Supply and fix in repairs sheet metal enclouser distribution board 415volt,Vertical TPN 6 Way with provision for suitable MCCB FP up to 160 A as incomer & MCBs SP/TP as out going as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 protection, including connection with the existing sub circutis, electric meter etc with proper size new copper cable, lugs, connectors etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs sheet metal enclouser distribution board 415volt,Vertical TPN 8 Way with provision for suitable MCCB FP up to 250 A as incomer & MCBs SP/TP as out going as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 protection, including connection with the existing sub circutis, electric meter etc with proper size new copper cable, lugs,connectors etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs sheet metal enclouser distribution board 415volt,Vertical TPN 12 Way with provision for suitable MCCB FP up to 250 A as incomer & MCBs SP/TP as out going as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 protection, including connection with the existing sub circutis, electric meter etc with proper size new copper cable, lugs,connectors etc complete all as specified and directed by Engr-in-Charge.
Supply and fix for MCB SP 6 to 32 Amps 240 volts 10 KA C series complete all as specified and directed by Engr-in-Charge.
Supply and fix for MCB SP 40 to 63 Amps 240 volts 10 KA C series complete all as specified and directed by Engr-in-Charge.
Supplying and fixing for MCB SPN 40 to 63 Amps 240 volts 10 KA complete all as specified and directed.
Supplying and fixing for MCB TP 40 to 63 Amps 415 volts complete all as specified and directed.
Supplying and fixing for MCB TPN 40 to 63 Amps 415 volts complete all as specified and directed.
Supply and foxing in repairs MCCB, 4-pole, breaking capacity 36 KA, 415 volts, 250 Amps including taking down unservicable one complete all as specified and directed.
Supply and fixing in repairs MCCB, 4-pole, breaking capacity 36 KA, 415 volts, 200 Amps including taking down unservicable one complete all as specified and directed.
Supply and fixing in repairs MCCB, 4-pole, breaking capacity 36 KA, 415 volts, 160 Amps including taking down unservicable one complete all as specified and directed.
Supply and fixing in repairs MCCB, 4-pole, breaking capacity 36 KA, 415 volts, 125 Amps including taking down unservicable one complete all as specified and directed.
Supply and fixing in repairs MCCB, 4-pole, breaking capacity 25 KA, 415 volts, 100 Amps including taking down unservicable one complete all as specified and directed.
Supply and fixing for MCCB, 4-pole, breaking capacity 25 KA, 415 volts, 63 Amps including taking down unservicable one complete all as specified and directed.
Supply and fixing for MCCB, 3-pole, breaking capacity 25 KA, 415 volts, 63 Amps including taking down unservicable one complete all as specified and directed.
Supply and fixing in repairs MCCB, 3-pole, breaking capacity 25 KA, 415 volts, 100 Amps including taking down unservicable one complete all as specified and directed.
Taking down carefully unserviceable FLP WP switch sockets, junction box complete and removing material from site and making good the disturbed surfaces of walls/ceiling etc complete all as specifed and directed.
Supply and fixing in repairs FLP WP Rotary switch with cable terminal box LM-6 material single pole, on & off 16 Amp complete all as specified and directed.
Supply and fixing in repairs FLP-WP switch socket & metalic top plug combination in LM- 6 material rating 16 Amps, 250 V, 2 pole plus earth with plug including necessary fixing arrangement & all out going electric connection complete all as specified and directed.
Supply and fixing in repairs FLP-WP Switch socket and metalic top plug combination in LM-6 material rating 32 Amp, 250 V, 2 pole plus earth with plug including necessary fixing arrangement and all out going electric connection complete all as specified and directed.
Supply and fixing in repairs FLP-WP Switch socket and metalic top plug combination in LM-6 material rating 63A , 440 V, 4 pole plus earth with plug including necessary fixing arrangement and all out going electric connection complete all as specified and directed.
Material and labour for sub main wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in ERW steel conduit 25 mm dia having wall thickness 2 mm, with and including 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor green colour as earth wire complete all as specified and directed. Note: 02 run single core 6 sqmm cable and one run 6 sqmm earth wire shall be measured as unit.
Supply and fixing bus bar chamber 04 way with 4 strips 200 Amps bus bar of aluminium strip at Incoming side with suiatble space for 01 incoming cables and outgoing of 03 cables .Bus bar fixed on insulators in zig-zag position, clearance in each strip and clearance at both side should not be less than 125mm with sufficient working space, height of bus bar chamber not less than 1 mtr, mounted MS angle 50x6mm, made of CRCA sheet 3 mm thick outdoor type, powder coated, both side opening, shutter in two halves, cable opening from bottom side with indicators R,Y,B, hinges through out the length of shutter with half turn locking arrangement, including grouting in PCC, all as directed by Engr-in-Charge. (Note : Size of Bus Bar chamber should not be Less than 1000 MM X 600 MM X 350 MM(LxBxD) all as specified and directed.)
Supply and fixing for busbar chamber 04 way, 04 strip 315 Amps bus bar of aluminium strip at Incoming side with suiatble space for 01 incoming cables and outgoing of 03 cables .Bus bar fixed on insulators in zig-zag position, clearance in each strip and clearance at both side should not be less than 125mm with sufficient working space, height of bus bar chamber not less than 1 mtr, mounted MS angle 50x6mm, made of CRCA sheet 3 mm thick outdoor type, powder coated, both side opening, shutter in two halves, cable opening from bottom side with indicators R,Y,B, hinges through out the length of shutter with half turn locking arrangement, including grouting in PCC, all as directed by Engr-in-Charge. (Note : Size of Bus Bar chamber should not be Less than 1000 MM X 600 MM X 350 MM(LxBxD) all as specified and directed.)
Material and labour for sub main wiring with four run single core 16 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in ERW steel conduit 40 mm dia having wall thickness 2 mm, with and including 16 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor green colour as earth wire complete all as specified and directed. Note: 04 run single core 16 sqmm cable and one run 16 sqmm earth wire shall be measured as unit.
Supply and fixing Flame proof distriution box TPN 4 way with bus bar weather proof in cast aluminium LM-6 enclosure, opened by externally spring type knobs, complete with suitable cable entry chamber to suit incoming cable and M-20 cable entries for out going cables from bottom, suitable for fixing on wall/ column/ sheet structure etc duly epoxy powder coated with flame proof flexible metallic conduit upto 01 mtr length ,space for 01 No. incoming MCCB upto 160 Amps and suitable o MCB SP/TP as outgoing duly tested adn certified by CMRI Dhanbad.
Supply and fix for LED Flood Light Luminaire 100 W Energy saving, Enviormental friendly, long life, exclusive innovative die-cast aluminium IP 66 flood light, suitable for highilighting architectural facade and general purpose lighting 100W 6000K complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level,connected to galvanized iron wire of 4 mm dia earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, earth wire protected by and including GI pipe 15 mm bore (light grade) and connected to main switch / MCB DBs box point as directed and including cement concret pit with CI cover 10 mm thick hinged to CI frame all as shown under electrical plate No 3 SSR Pt - I 2009 including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel, 20mm bore GI Pipe (Medium grade) for watering, charcoal and salt in alternative layers of 15cm thick all arround the electrode, including necessary excavation and earth work in any type of soil complete all as shown in electrical plate of SSR part -I and testing on completion all as directed.
CHADHA ENGINEERS
Alpha Engineers and Builders
D.N.Gupta and Sons
Baliyan Electrical Works
M/s Shiksha Enterprises
SANJEEV ENTERPRISES
Bharat Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .