Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹6.9 L+₹47.20 (<0.01%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹9.3 L+₹2.3 L (33.3%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | Rejected-Technical | - | Rejected-Technical DUE TO NOT FULL FILL ELIGIBILITY CRITERIA | |
| 5 | Rejected-Technical | - | Rejected-Technical DUE TO NOT FULL FILL ELIGIBILITY CRITERIA |
Tender Value
Refer Docs
EMD Value
₹18,500
Closing Date
15 Jul 2024, 2:15 pmClosed
EE
CHANDRAWAL WATER WORKS
Improvement of electrical system with other allied works at administrative block and laboratory room at Okhla Water Works
2024_DJB_259164_1
NIT NO. 02 (2024-25) WW-III
Open Tender
Miscellaneous Works
Works
180 days
CHANDRAWAL WATER WORKS
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJBEMD A/c No-50448339804 THROUGH SUBPAISA GATEWAY
₹18,500
30 Jul 2024
8 Jul 2024
15 Jul 2024
8 Jul 2024
15 Jul 2024
8 Jul 2024
8 Jul 2024 - 15 Jul 2024
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B(Make: Gloster, Grandlay, Havells, CCI, ICC, Universal/DJB approved make).
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (Make: Gloster, Grandlay, Havells, CCI, ICC, Universal/DJB approved make). a) 1 x 1.5 sqmm
b) 2 x 2.5 sqmm
c) 2 x 4 sqmm
d) 2 x 6 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (Make: Philips, Bajaj, Crompton & Havells/DJB approved make) a) 5/6 amps switch
b) 3 pin 5/6 amp socket outlet
c) 15/16 amps switch
d) 6 pin 15/16 amp socket outlet
Supplying and fixing the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as required. A) 6 module ( 200mm x 75 mm )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. A) 2 x 10 + 1 x 6 sqmm earth wire
Supplying and fixing of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including ,painting etc.
Supplying and fixing of modular blanking plate on the existing modular plate and switch box excluding modular plate as required.
Supplying and fixing of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
Supplying and fixing of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. A) 20mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE alumium conductor cable of 1.1 KV grade as required. (Make: Gloster, Grandlay, Havells, CCI, ICC, Universal/DJB approved make) a) 4 x 25 sq. mm ( 28 mm )
Providing and fixing following rating and breaking capacity and pole MCCB with enclosure with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 amp 10 KA (Make: L&T/Siemens/Cutler Hammer/Indocop/C&S/Protex and DJB approved make)
Providing and fixing Higher Wattage Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack.(Make: (Make: Philips, Bajaj, Crompton & Havells/DJB approved make). a) 36 W LED 6500 K
Supplying of 48" ( 1200 mm ) ceiling fan with all accessories and making connection etc as reqd. at site (Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
Supplying and fixing of LED decorative diffuser 2x2 panel light i/c making connection etc as reqd. at site (Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
Supplying and fixing of brass batten/angle holder including connections etc as required .
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door.( Make: L&T/Siemens/Cutler Hammer/Indocop/C&S/Protex and DJB approved make ).
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (Make: L&T/Siemens/Cutler Hammer/Indocop/C&S/Protex and DJB approved make )
Supplying and fixing following 63 amp, double pole, 240 volts, DP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: L&T/Siemens/Cutler Hammer/Indocop/C&S/Protex and DJB approved make ).
Supply of XLPE insulated, PVC sheathed Al.conductorArmoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 4C x 25 SQ mm (Make: Gloster, Grandlay, Havells, CCI, ICC, Universal/DJB approved make).
Supply of XLPE insulated, PVC sheathed Al.conductorArmoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 3C x 6 SQ mm (Make: Gloster, Grandlay, Havells, CCI, ICC, Universal/DJB approved make).
Providing of 15" ( 380mm ) exhaust fan with all accessories and making connection etc as reqd. at site (Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
Installation, testing and commissioning of exhaust fan including wiring the down rods standard length single core copper conductor cable i/c if wooden work is required etc as reqd. at site
Supplying and fixing of 32 mm dia X 1.5.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 1 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. This also include supply & fixing of 1 Nos, 32 mm dia X 1.5.00 metres long G.I. pipe with bend for junction box.
New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. (Make: Philips, Bajaj, Crompton & Havells/DJB approved make) a) 70/72 watt LED
Supplying of 100 watt flood light fitting pressured dia cast housing with IP65 protection efficient high 220-240V output emitter LED for better distribution with dimension 447 X 163 x 327 mm and 6500 colour with lumens 15500 with all accessoiresetc as etc as reqd. at site.(Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
Installation of LED light flood light 1000 Watts with all safety measures with the help of skilled labour/technician as required.
Supplying and fixing of angle frame of suitable size ( 50" x 50" ) including excavation and repairing the same etc as reqd. at site.
Supply, installation, testing and commissioning 3' x 3' feet size cubical panel wall mounted 3 phase 4 wire system and dust proofed the cubical panel made of 16 gauge CRCA sheet supported on angle channel. The door shall be made out of 16 gauge CRCA sheet duly painted and having aluminium bus bar the 25 x 10 size following. 3 output (1output per phase) and suitable for three phase supply power supply connections by fixing the incoming - 125 amp MCCB – 1 No.and outgoing 100 Amp - 1 nos , TP MCB - 3 nos, DP MCB -6 No. SP MCB 5 ampto 32 amp - 8 nos , 3 No’s indicating LED etc as reqd. (Make: L&T/Siemens/Cutler Hammer/Indocop/C&S/Protex and DJB approved make ).
Installation of LED light 70 Watts on street light Pole after erection with all safety measures with the help of skilled labour/technician as required.
Supply of SMC junction boxes anti-corrosive water resistant, UV protected, High temp resistant, weatherable and suitable for all kinds of climatic conditions. Self-colour fire retardant and high dielectricstrength maintenance free. .(Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
Installation of junction boxes on the each pole with the help of clamps, nut & bolts etc. The junction boxes should have Mini SP C-series MCB of 6 A
Supplying and fixing of fan rod 3' for the ceiling fan including making connection etc as reqd.
Loading, unloading, cartage and transportation charges for the above pole upto the side i/c charges of heavy labour etc. as per site requirement.
S/F of double box type fitting complete with all accessories i/c making connection etc as reqd. TMC 502 1X T-LED 22W P3242 i/c having 2 nossteller 20 watt LED tube light in the existing fitting etc as reqd. .(Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
Supplying and fixing of LED bulb 12 watt i/c making connection etc as reqd. at site .(Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
Installation, testing and commissioning of LED fitting of all type complete with all accessories directly on ceiling wall including connection with 1.5 sqmm FRLS PVC insulated copper conductor cable and earthing etc as reqd. at site.(Make: Gloster, Grandlay, Havells, CCI, ICC, Universal/DJB approved make).
Installation, testing and commissioning of 48" ceiling fan including wiring the down rods standard length single core copper conductor cable etc as reqd. at site. .(Make: Philips, Bajaj, Crompton & Havells/DJB approved make).
Testing and commission of complete work in the presence of Engineer-in-charge with full satisfaction.
Supplying and fixing of bell buzzer 220 volt including making connection etc as reqd. at site..(Make: Philips, Bajaj, Crompton & Havells/DJB approved make)
N.K. BUILDCOM
ASHMITA ENGINEERS AND TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .