Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-Finance | L1 | Accepted-Finance Technically qualified | |
| 2 | L2₹32.4 L+₹45,940 (1.44%)Accepted-Finance | L2 | Accepted-Finance Technically qualified | |
| 3 | Not Admitted-Fee/PreQual/Technical H NO 1300 PUSHP VIHAR COLONY GUPT GANGA ROAD KANGRA 176001 | KANGRA | KANGRA | HIMACHAL PRADESH | 176001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹25.0 L
EMD Value
₹45,000
Closing Date
18 Jun 2020, 5:00 pmClosed
Executive Engineer
Elect. Division HPPWD Palampur
Construction of CHC building at Haripur in Tehsil Haripur Distt. Kangra (HP) (SH-Providing EI therein)
2020_PWD_37832_3
Elect. Div. HPPWD Palampur
Open Tender
Electrical Works
Item Rate
365 days
Haripur Tehsil Dehra
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Executive Engineer
₹45,000
23 Jul 2020
4 Jun 2020
19 Jun 2020
4 Jun 2020
18 Jun 2020
4 Jun 2020
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group C
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group C
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x2.5 Sq. mm.
2x6 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.
3x1.5 Sq. mm.
3x2.5 Sq. mm.
3x4.0 Sq. mm.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 5/ 6 Amps one way Modular switch.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
5 pin, 5/ 6 Amps Modular socket outlet.
Telephone socket outlet, Modular.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 15/ 16 Amps one way Modular switch.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
6 pin,15/16 Amps Modular socket outlet.
Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-
2 modules (78mmx78mmx50mm)
4 modules(140mmx78mmx50mm)
12 modules (205mmx135mmx60mm)
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14G/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 200A TPN Copper/Aluminium Busbar ( Vertical) & Earth strip throughout the length of Panel (current density of Copper/ Aluminium Busbar shall be 1mmx1mm=1.0 Amp.) Aluminium shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Approximate Size of Panel H- 1500 X W-1650 X D-300MM. Assembly Charges of Aluminium/Copper solid/ Copper flexible wire interconnection Busbar to MCCB/ SWITCH & MCCB/ SWITCH to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control & 1.0sq. mm for Scada Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc.and the panel should be approved/tested from the CPRI Lab and should confirm I.S.64139.(EVA or approved equivalent make)
L.H.S. Panel (1500mm (Length) x 1650mm (width) x 300mm (deep)(Approxi)
MATERIAL:
OUTGOING :
MCCB 63 A 4P 25 kA-05 Nos with O/L & S/C protection,Spreater Terminal Mccb 63 A4P 10Nos.RHOM Ext.3Nos.
The Panel shall include the following Switchgear & accessories; as per the Make of Schneider, L&T, Siemens, ABB etc.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc.
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14G/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 63/100 A TPN Aluminium Busbar ( Horizental) & Earth strip throughout the length of Panel (current density of Aluminium Busbar shall be 1mmx1mm=1.0 Amp.) Aluminium shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Approximate Size of Panel H- 1500 X W-500 D-200mm Assembly Charges of Aluminium/Copper solid/ Copper flexible wire interconnection Busbar to MCCB/ SWITCH & MCCB/ SWITCH to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control & 1.0sq. mm for Scada Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc.and the panel should be approved/tested from the CPRI Lab and should confirm I.S.64139(EVA or approved equivalent make)
L.H.S. Panel (750mm (Length) x 600mm (width) x 200mm (deep)(approxi.)
MATERIAL:
OUTGOING :
Space for MCB 63 A DP Isolator & Rccb MCB 6 To 32 A SP 36 nos MCB Short Bus Bar 36 Nos.
The Panel shall include the following Switchgear & accessories; as per the Make of Schneider, L&T, Siemens, ABB etc.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc.
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-4 way
Double door-8 way
Double door-12 way
Double door-16 way
Providing Installation testing and commissionning of ceiling fan with socket size modular steo type electronicfanregulator including wiring the down rods of standardlengh (Up to20 cm) with 16/0.20 mmtwin twisted flexible,cotton braided copper cable,includingproviding and fixing phenolic laminated sheet cover on the fan box and earting etc. as required.
Ceiling Fan 1200 mm sweep, Category-A
Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Supplying and fixing surface Mounted Round type & Square type LED 10 Watt ( 900 lumen), 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No :-Panasonic( PDLM010106P(Circular)10 W ADL PDLM11106P(Square) 10 W /Wipro/Philips/or Equivalent
Supplying and fixing surface mounting square type LED 20 Watt ( 2000 lumen), 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No :-Panasonic (ADL PDLM1206P) 20 W(Square)/Wipro/Philips/or Equivalent
Supplying and fixing surface mounting Wall Bracket type street light LED 24 Watt ( 2400 & lumen), 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No :- K-Lite(5308-24W-Polar wall bracket)/Wipro/Philips or Equivalent
Supplying and fixing surface/recess mounting Path(Foot) light LED 6Watt ( 600 lumen), 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No :- K-Lite(2745-6 W-Foot Light)/Wipro/Philips or Equivalent
Supplying and fixing surface mounting Bed light LED 12 Watt ( 1200 lumen), 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No :- K-Lite(3677-12 W-Bed Light)/Wipro/Philips or Equivalent
Supplying and fixing Bulk Head LED 12 Watt (1200 lumen), 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No :- k-Lite(4074-12W)(Bulk Head)/Philips/Wipro or equivalent.
Providing and fixing decorative extruded tube fixture having high quality design suitable for LED tube up to 36 Watt (3600 lumen) 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, including one no. tube rod 36 Watt complete with all accessories, connections, testing and commissioning etc. as required.
Cat No :-Panasonic( PBTM08368-36 W -Tube Light 4 Feet Long)/Wipro/Philips or equivalent.
Providing and fixing decorative extruded tube fixture having high quality design suitable for LED tube up to 10 Watt (1000 lumen) 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, including one no. tube rod 10 Watt complete with all accessories, connections, testing and commissioning etc. as required.
Cat No :-Philips( BN021LED10S-10 W Tube Light - 2 Feet Long)/Wipro/Panasonic or equivalent.
Supplying and fixing surface mounting Square type LED 40 Watt(2'X2') (4000 lumen), 6000K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No :- K-Lite(2270-40W)(2'X2')/Philips/Wipro or equivalent.
Supplying and fixing surface mounting LED 31 Watt(1'X4') (3100 lumen), 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No :- Wipro(CRCO13S038HP57G1)(1'X4'-31W)/Philips/K-Lite or equivalent.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Providing and laying of aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground in the same trench, in one tier horizontal formation to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering etc. of required size:-
Armoured cable 95 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 95 sq. mm (3.5 core)
Supplying and fixing of G.I.pipe class "A" 80 mm dia. as required complete in all respects
Supplying and fixing of G.I.pipe medium class 32 mm dia. as required complete in all respects
Supplying and fixing of following sizes of steel conduit along with the accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required:-
25 mm. dia
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
25 mm. dia
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
50 mm. dia
Providing and fixing Aluminum Composite Panel Sheet for exhaust fan as required complete in all respects and to the best sasfaction of Engineer-in -charge.
Supplying and placement of Rubber Isulation Mat Hollow of thickness 2.2mm and dimension(2mX1m) as required complete in allrespects.
Providing and fixing extra conduit down rod of 20mm dia. x10 cm with 16/0.20 mm twin twisted flexible, cotton braided, copper cable including painting, connections etc. as required. ( Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).
Supplying and drawing LAN cable CAT 6, solid copper conductor protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
UTP Cat 6 Computer LAN Cable with star Seprator
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
25 Liter capacity water heater (Cat-A)
Supplying and fixing following rating Modular switch/socket in the existing switch box/cover plate including connections etc.as required
Socket 10 A/25Amps. Combined
Makes:- L&T (Cat No :- CB91302CW25)
Switch 20Amps. Combined
Makes:- L&T (Cat No :- CB91101SW20)
Supplying, Installing,Testing and Commisioning of Split Type Air Conditioner 1.5 TR SPLIT AIR CONDITIONER (Hot and Cold) confirming to I.S.I -1391 Part-1992 with ammendent No. 1(expect power consumptions norms) fitted with Hermatically shielded Air Conditioner with installation & testing and commissioning etc. as rquired in all respects.
Makes:- (Model No. : SAC 18VH EZO) Star/Decon.
A.C. Unit 1.5 Ton capacity
Supplying and Fixing wall mounting voltage stablizer 4 KVA (Microtek/Whirlpool/V-Guard make) automatic type with output 240 Volts with voltage regulator range from 130 volts to 280 volts and Auto cut off beyond this range and time delay opration for the surges and fluctuations suitble for 1.5 TR capacity Split AC making connections etc. as required.
Makes:- Godrej(Model No.39121041SD00031)Microtech/Whirl Pool/V Guard equivalent.
Automatic Voltage Stabilizer 4 KVA
P/F of M.S out door heavy duty stand powder coated suitable to hang 1.5/2 TR split A.C with six Nos. Anchor bolts as required complete in all respects and as per direction of Engineer - in- charge.
S/F of Copper tube with insulation for A.C 1.5 TR capacity complete in all respects as required.
JAMWAL ELECTRICAL WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .