| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC HARSHA KUTHI SIDDHESWARITALA ROAD MONIRAMPORE BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹28.2 L+₹5.9 L (26.6%)Rejected-AOC ABANI APARTMENT 1ST FLOOR 6 2 TALBAGAN ROAD WEST PO NONACHANDANPUKUR BARRACKPORE KOLKATA 700 122 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700122 | L2 | Rejected-AOC High Rate | |
| 3 | L3₹28.5 L+₹6.2 L (28.0%)Rejected-AOC | L3 | Rejected-AOC High Rate | |
| 4 | L4₹29.0 L+₹6.7 L (30.1%)Rejected-AOC MANNAPARA MONIRAMPUR P O P S BARRACKPORE DIST 24 PARGANAS N KOLKATA 743101 WB | 743101 | L4 | Rejected-AOC High Rate | |
| 5 | L5₹29.4 L+₹7.1 L (31.6%)Rejected-AOC | L5 | Rejected-AOC High Rate |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
25 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR TO SECURITY INFRA AND ALLIED WKS IN 6 WING UNDER GE AF BARRACKPORE
2021_MES_487821_2
8340/BKP/AF OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE AF Barrackpore
Pl refer tender documents
5 documents required · 5 mandatory
₹500
GE AF Barrackpore
₹40,000
Yes
1 Feb 2022
18 Dec 2021
27 Dec 2021
18 Dec 2021
25 Dec 2021
18 Dec 2021
60 days
Amount
Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED( 80-100)microns with pure Zinc (99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3034. The outer and inner pipe should be 76.2 mm & 41.9 mm 3mtrs Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional corrosion protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity The job includes digging the pits of dimension 60cm X 60cm up to depth 3.1m and replace the soil with low resistive soil as approved by Engr-in-Charge then make a bore of dia 200mm of depth 3.1m and refilling the same by Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having RoHS Certification from NABL accredited lab. Good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2 bags. including FRP (Fiber reinforced plastic) light weight, high mechanical strength, chemical resistance with detachable easy locking lid of size 250mm X 250mm of thickness 2mm,and the earthing should be installed by applicator of the manufacturer/authorised dealer complete all as specified and directed. (Make : ASHLOK / MACKMET).
Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED( 80-100)microns with pure Zinc (99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3034. ASEEL -19 The outer and inner pipe should be of dia 76.2 mm & 41.9mm 2mtrs Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional corrosion protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity The job includes digging the pits of dimension 60cm X 60cm up to depth 2.1m and replace the soil with low resistive soil as approved by Engr-in-Charge then make a bore of dia 200mm of depth 2.1m and refilling the same by Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having RoHS Certification from NABL accredited lab. Good earth is to be arranged to fill the excavated pits by mixing the same with BFC 1 bags (as per soil condition). including FRP (Fiber reinforced plastic) light weight, high mechanical strength, chemical resistance with detachable easy locking lid of size 250mm X 250mm of thickness 2mm, and the earthing should be installed by applicator of the manufacturer/authorised dealer complete all as specified and directed. (Make : ASHLOK / MACKMET).
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all complete as specified and directed.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI strip upto 7.5m including testing consider in this item).
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item).
M & L for earthing continuity conductor or main earthing lead fixed to wall or recess or chases with 20 x 3 mm copper strip fixed on porcelin insulator at distance 45 cm including nut bolt drilling hole etc after taking down old unserviceable complete all as specified and directed.( Note : Joining of copper strip shall be made by brazing after fixing of nuts & bolts)
M&L for fixing in replacement of Galvanised iron strip 32 x 6mm buried in ground or on wall all as required and directed.
M&L for 40mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. (MAKE: JINDAL/PRAKASH/SURYA)
S & F Thermoplastic weather proof empty box (IP 65) with plane wall of size 300mm (L) X 150mm (B) X 170mm (H) fixed on wall with provision of nut, bolts, washer etc. including fixing of test point terminal block inside the box which made out of gun metal or phosphorous bronze of size 75mm X 75mm X 25 mm, drilled and screwed including 3 Nos 8mm dia 25 mm long hex Head screw including taking down old unserviceable one complete all as specified and directed.
M&L for fabrication of display board for earth pit nos. location and periodical test results for power circuit earthing, machinary earthing, lightening conductor earthing, made of GI shett 4.0 mm thick, rectangular welding on 12 mm dia rod of minimum height from ground level 45 cm including fixing in PCC 1:2:4 with 20cm X 20cm X 10cm grade aggregate foundation to be carried out at different location. dimension of board shall be 30 cm X 25 cm X. The instruction shall be written black painted board in white letters not less than 2" size for all type of boards complete all as specified and directed by the Engineer-in-charge. Note : (a) All necessary GI sheet, aluminium screws and PCC works etc are deemed included to the rate qioted by the contracor. (b) The fabrication of condents on the screen printing should be collected before printing the board from Engineer-in-charge.
M&L for cement concrete PCC 1:3:6 type C-2 using 40mm graded stone aggregate in filling foundations and mass concrete complete including necessary form work foundation complete all as specified and as directed .
M&L for dismentling the old earth pit and provision the nearth pit made out of cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh all as directed.
M&L for painting earth pit chamber and earth pit by two coat of syenthetic enamail paint after cleaning earth pit properly with iron wire brush and indicating board as per colour code as specified and directed by Engr-in-Charge.
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed.
Taking down/out unserviceable or serviceable LT UG Cables of nominal Cross Sectional Area but Nominal Cross-Sectional Area 185 Sqmm 3.5 Core.
All as per Item No. 18 above, but Nominal Cross-Sectional Area 95 Sqmm 3.5 Core.
All as per Item No. 18 above, but Nominal Cross-Sectional Area 70 Sqmm 3.5 Core.
All as per Item No. 18 above, but Nominal Cross-Sectional Area 50 Sqmm 3.5 Core.
Supply & Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area Nominal Cross-Sectional Area 185 Sqmm 3½ Core.
All as per Item No. 22 above, but Nominal Cross-Sectional Area 95 Sqmm 3.5 Core.
All as per Item No. 22 above, but Nominal Cross-Sectional Area 70Sqmm 3½ Core.
All as per Item No. 22 above, but Nominal Cross-Sectional Area 50Sqmm 3½ Core.
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).
Supply and lay bricks of class 'B' type for protection of under ground cable in trends all as specified
M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site.
Taking down/out unserviceable GI / HDPE/Polyethylene flexible pipes of any descriptions, laid in trenches and/or fixing with Walls/Poles complete all as specified and as directed.
S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. Make : JINDAL/BANSAL/NTL.
M&L Straight Through (cold shrink) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area exc. 25 Sqmm but not exc. 50 Sqmm, 3.5/4 Core and Testing complete all as specified and as directed.
M&L Straight Through (Cold shrink) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area exc. 70 Sqmm but not exc. 95 Sqmm, 3½ Core and Testing complete all as specified and as directed.
All as per item no 41 above but of Nominal Cross-Sectional area exc. 120 Sqmm but not exc. 185 Sqmm, 3½ Core and Testing complete all as specified and as directed.
Globe Electricals
BUSINESS SYNDICATE
BANERJEE CONSTRUCTION
SARKAR AND COM
ZENITH CONSTRUCTION
Electro Builders
Oenix and associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .