Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.6 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹45.0 L+₹45,249 (1.02%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹47.8 L+₹3.3 L (7.33%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹51.7 L+₹7.2 L (16.2%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹54.2 L+₹9.7 L (21.9%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Oct 2023, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
MAINTENANCE REPAIR AND REPLACEMENT OF INTERNAL ELECTRICAL FITTINGS, FIXTURES, DBS AND SUB MAIN WIRING AT NAVAL PARK, AMZARI PARK AND SWIMMING POOL UNDER GE (NB) VISAKHAPATNAM
2023_MES_607399_2
C/8214/23-24/E8 / Token 59 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹90,000
Yes
5 Apr 2024
12 Oct 2023
30 Oct 2023
12 Oct 2023
28 Oct 2023
21 Oct 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc except light fitting. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers any capacityincluding all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
All as per item No. 04 above but for One light point controlled by two Nos two way switch complete ditto
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 04 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 09 above but for One light point controlled by two Nos two way switch complete ditto
All as per item No. 09 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 09 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 09 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F steped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (ii) Four runs of 10 sqmm and two runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
S & F repairs of single core 1.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 2.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 4 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 6 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing Sub main wiring complete all as specified and as directed.
S & F repairs of single core 10 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing /Sub main wiring complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 2.5 sqmm complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 4 sqmm complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 6 sqmm complete all as specified and as directed.
S & F in repair Single phase sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 25 Amp 240V, C-curve complete all as specified and as directed. (Make: Havell's Cat No. DHDMCSN0251025 or equivelant of make as per List of Manufacturer's)
S & F in repairs AC Plug for two pin and earth plug and socket enclosure complete all as specified and as directed.
S & F in repairs AC Socket for two pin and earth plug and socket enclosure complete all as specified and as directed.
S & F in repairs 3 pin male top plug, 5 Amps for electrical fittings complete all as specified and as directed.
S & F in repairs 3 pin male top plug, 15 Amps for electrical fittings complete all as specified and as directed.
S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDNTHCDRW04 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, TPN, 6 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as diretced complete all as specified and directed. (Make: Havell's cat part No. DHDNTHCDRW06 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW12 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repair MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB Four pole 63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCFPF063 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB Four pole 63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCFPF063 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB Four pole 100 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMJCFPF100 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repair MCB Four pole 100 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMJCFPF100 or equivalent make as per List of Manufacturer's)
S & F in repair RCBOs for earth leakage, overload & short circuit protection, 6 to 32 Amps, 2 pole, 100mA, conforming to IEC: 61009 & EMC standard EN 61543 for electrical networks with high harmonics/pulsated currents and transients with earth fault indicator & positive contact indication complete all as specified and as directed (Make : Havell's Cat part No. DHCEACSN20300 06 to 32 or equivelant of make as perList of manufacturer's)
S & F in repair RCBOs for earth leakage, overload & short circuit protection, 63 Amps, 4 pole, 100mA, conforming to IEC: 61009 & EMC standard EN 61543 for electrical networks with high harmonics/pulsated currents and transients with earth fault indicator & positive contact indication complete all as specified and as directed (Make : Havell's Cat part No. DHBMACDP410006 or equivelant of make as perList of manufacturer's)
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
Supply and fix in repair fan capacitors of 2.5 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole two way 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 16 amp 240 volts, complete all as specified and as directed.
S & F in repairs bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
S & F in repairs Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts, universal with PVC rectangluar gang box complete all as specified and directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal with PVC rectangluar gang box complete all as specified and as directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed.
S & F in repairs switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F in repairs switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs modular bell push 6 amp 240 volts1 module,complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs stepped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 1 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 2 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 3 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 4 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 6 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 8 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 12 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 16 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 18 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 1/2 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 3 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 4 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 6 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 8 module complete all as specified and as directed.
S & F in repair 1/2 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 3 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 4 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 6 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 8 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S & F in repairs LED Drive 36/40 watts as per site requirement complete all as specified and as directed.
S & F in repairs LED Drive 12-15 watts as per site requirement complete all as specified and as directed
S & F in repairs LED Drive 18-24 watts as per site requirement complete all as specified and as directed
S & F in repairs LED Drive 3-12 watts as per site requirement complete all as specified and as directed
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 10 Watt, Lumen ≥ 1000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Jaquar Cat No. LGLZ01X010XC or equivelant of make as per list of manufacturer)
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 20 Watt, Lumen ≥ 2000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Jaquar Cat No. LKBS01S020X or equivelant of make as per list of manufacturer)
S & F in repairs LED light fittings, ceiling mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 2'x2', 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LULTSLS036XC or equivelant of make as per list of manufacturer)
S & F in repairs LED light fittings, surface mounted mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 2'x2', 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LULTU1S036XC or equivelant of make as per list of manufacturer)
S & F in repairs LED light fittings, Ceiling/surface mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 1'x4', 33 Watt, Lumen ≥ 3300, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LULU4SL033XC or equivelant of make as per list of manufacturer)
S & F in repairs Recess mounted spotlight, 2 Watt, warm white colour with aluminium housing and prismatic diffuser, white finish with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LSPT06R002XW or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Surface mounted round/square, die cast aluminium housing, 6 Watt as per the existing cutout, 100-110mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNRO02R006SC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R012XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 15 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R015XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Surface mounted round, die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNRO02R012SC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Surface mounted round/square, die cast aluminium housing, 15 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNRP02R015SC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 18 Watt as per the existing cutout, 200-275mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R018XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 24 Watt as per the existing cutout, 200-275mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R024XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, surface mounted round/square, die cast aluminium housing, 18 Watt as per the existing cutout, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNRO02S018SC or equivelant of make as per list of manufacturer)
S & F in repair 7 Watt, LED picture light fittings, having 270 Lumen and 3000K, correlated colour temperture, decorating light with all accessories, internally pre-wired and connecting up complete all as specified and directed. (Make : Phillips Model No. Muziris 31402 or equivelant model of make as specified in list of manufacturer).
S & F in repairs LED Bulb, 5 Watts, B-22 Lumen ≥ 500, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
S & F in repairs LED Bulb, 9 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
S & F in repair LED Strip light, 24V DC, 25W, 8mm width with IP 20 protection, uniform light distribution and long lasting adhesive and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. (Make: Jaquar Cat No. LSTP03X005XW or equivelant of make as per list of manufacturer)
S & F in repairs LED Power Supply for IP20 strip light, 24V DC, 30 Watt suitable for strip lights and connecting up complete all as specified and directed. (Make: Jaquar Cat No. LDRV01S030XX or equivelant of make as per list of manufacturer)
S & F in repairs LED tube rod, T8, 20 Watt, polycarbonate diffuser, 1200mm length, CCT: WW/CW complete all as specified and directed. (Make: Jaquar Cat No. LTBL01X010XC or equivelant of make as per list of manufacturer)
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 10"x8" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 6"x4" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
S & F in repairs Rigid non-metalic PVC conduit (32mm dia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
S & F in repairs 10 Sqmm size Aluminium thimbles to terminate electrical wires/cables or connections in a professional manner to minimize current leakage and to avoid overheating or electrical failures due to loose connection complete all as specified and as directed.
S & F in repairs 16 Sqmm size Aluminium thimbles to terminate electrical wires/cables or connections in a professional manner to minimize current leakage and to avoid overheating or electrical failures due to loose connection complete all as specified and as directed.
S & F in repairs 25 Sqmm size Aluminium thimbles to terminate electrical wires/cables or connections in a professional manner to minimize current leakage and to avoid overheating or electrical failures due to loose connection complete all as specified and as directed.
S & F in repairs 6-10 Sqmm size Copper thimbles to terminate electrical wires/cables or connections in a professional manner to minimize current leakage and to avoid overheating or electrical failures due to loose connection complete all as specified and as directed.
Taking down ceiling fan / EXHAUST FAN any sweep from the site including servicing, oiling and greasing etc and re-fixing the ceiling fan / exhaust fan of any sweep again at existing site and connecting up including Provn of 1.5 three core copper FRLS chord wire from ceiling rose to ceiling/exhaust fan and replacement of minor accessories such as clamp, nut, bolts, split pin, rubber bush etc complete all as specified and as directed . (Note for item Nos 76 to 91, & 97 to 101: Makes and Models of fittings/fixtures under these items shall be as per the existing makes & Models as per the site requirement and as directed by the Engr-in-Charge)
VIJAYA DURGA CONSTRUCTIONS
SHIRIDI SAI BUILDERS
SAMPATH ENTERPRISES
SRI THULASI TECH
NIKESH ENTERPRISES
M/s SAI GANESH ENGINEERING ENTERPRISES
ANAND ENTERPRISES AND ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .