AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur- 342011
REPAIR AND MAINT OF VRF-III BASED AC PLANT LOCATED IN (NTC BLOCK 3 AND 4) AT DEFENCE LAB JODHPUR
2022_MES_528547_1
8474/E8
Open Tender
Civil Works
Item Rate
330 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹19,800
Yes
6 Jul 2022
4 Jun 2022
30 Jun 2022
4 Jun 2022
28 Jun 2022
14 Jun 2022
6 Jun 2022 - 13 Jun 2022
Amount
Comprensive daily Maintenance, checking, testing, ON/OFF of Variable refrigerant flow modular type air conditioning system with stepless modulation complete with indoor and outdoor unit individual remote complete centralised controller inter connected refergerant piping checking of pipe lines for gas laeakage oil control cable for the following equipments and accessories:- (A) Outdoor Units:- Outdoor units consists of compressor, heat exchanger, condenser fan, auto check function for error, Auto address setting microprocessor panel, isolating valves for the following capacity. Heat pump type (Cooling and Heating) of 10 Hp - 04 Nos Cooling and Heating type 12 Hp - 09 Nos Cooling and Heating type 14 Hp - 02 Nos Cooling and Heating type 16 Hp - 01 Nos Cooling and Heating type 18 Hp - 04 Nos (Total 20 Main units and 04 slave unit = 24 Outdoor units) (B) Indoor units:- Indoor unit addresssetting multispeed motor oil section with DX coil outer consist drain pipe water lift mechanism its insulation pipe connection fresh air intake sysem with the following capacities. Ceiling mounted Cassette type 2.6 TR - 09 Nos Ceiling mounted Cassette type 3.3 TR - 07 Nos Split high wall mounted type of different capacity - 138 Nos (Total 154 indoor units)
M&L for servicing of Daikin VRF-III including (outdoor and indoor) at the existing location with suitable electronic machine, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower,rewinding, assembling, testing and commissioning etc complete all as specified and directed by Engr-in-charge.
Supply and charging of gas R- 410A inside the compressor and testing Complete all as specified and directed by Engr-in-Charge.
S&F in replacement Remote controller for split AC As per sample Complete all as specified and directed by Engr-in-Charge.
S&F in replacement Battery Cell 1.5 Volt, Complete all as specified and directed by Engr-in-Charge.
S&F in repair of Printed Circuit Board for indoor unit of any capacity available at site complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Printed Circuit Board for indoor unit of any capacity available at site complete all as specified and directed by Engr-in-Charge.
S&F in replacement of inverter PCB for outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Noise filter PCB for outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Main control PCB for outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Over Voltage PCB for outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Fan driver PCB for outdoor unit complete all as specified and directed by Engr-in-Charge. Make-Daikin
S&F in replacement of Reverse phase PCB for outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Magnetic contactor for outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Fan motor for outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F MCB SP 6 - 32 Amps 230 V including taking down old UNSV MCB Complete all as specified and directed by Engr-in-Charge Make L&T/Legrand/Schnider/Havells or any equivalent approved make
S&F MCCB 4 pole 415 volts 160 Amp rotary type breaking capacity 36 KA including taking down old UNSV MCCB Complete all as specified and directed by Engr-in-Charge . Make L&T/Legrand/Schnider/Havells or any equivalent approved make
S&F in replacement of Sheet metal encloseure with 3 pin plug and socket with 20 Amp MCB single pole. Complete all as specified and directed by Engr-in-Charge. Make : L&T/Legrand/Schnider/Havells or any equivalent approved make
Supply and Fixing in replacement scroll fix Compressor for outdoor of capacity 14 HP as per existing size and model complete all as specified and directed by Engineer-in-charge.
Note:- (a) One skilled VRF Operator having good knowledge of system will be provided by contractor for daily ON/OFF operation & testing of all indoor & outdoor units and maintaining the record book on daily basis from 09:00 AM to 06:00 PM during opening of NTC Lab. (b) One Electrician for Electric related issues in VRF system for Outdoor Main Electric panels/indoor circuits provided by contractor. (c) Material (submain wire, lugs& cable of suitable size etc.) to resolve the electrical issued occurred on site provided by contractor itself.
SNEH CORPORATION
vinayandsons
Shri Electrical Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .