| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.7 LAccepted-AOC 130 2 RAM BAGH UPPER HARIPUR SUNDER NAGAR DISTRICT MANDI H P 175018 | MANDI | HIMACHAL PRADESH | 175018 | ₹40.7 L Quoted ₹41.5 L | L1 | Accepted-AOC award issued being L1 |
| 2 | L2₹42.3 L+₹80,000 (1.93%)Rejected-Finance MANDI DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | ₹42.3 L+₹80,000 (1.93%) | L2 | Rejected-Finance rejected being L2 firm |
Tender Value
₹39.5 L
EMD Value
₹79,060
Closing Date
4 Apr 2023, 10:00 amClosed
Executive Engineer, Electrical Division, HP.PWD Ma
Executive Engineer, Electrical Division, HP.PWD Mandi
Annual comprehensive Maintenance Contract CMC and operation 24 7 for 33 11 KV HT Panel and Transformer existing at Shri Lal Bahadur Shastri Govt. Medical College and Hospital Nerchwok District Mandi
2023_PWD_71693_1
PW/MED/TA/NIT/ e-notice/22-23-8953-64 dt 17.03.23
Open Tender
Electrical Works
Item Rate
365 days
Nerchowk
plz refer to bid doc
11 documents required · 11 mandatory
₹1,500
₹79,060
14 Nov 2024
28 Mar 2023
4 Apr 2023
28 Mar 2023
4 Apr 2023
28 Mar 2023
Amount
Annual Comprehansive Maintenance Contract (CMC)&Operation 24/7 for 33/11kv HT Panel and Transformer's existing at SLBS.Govt Medical Collage& Hospital Nerchowk in Distt. Mandi (HP)
SCOPE OF WORK
Supervision of all function of Vacuum Circuit Breaker's and its IR Value
Providing lubricants and proper cleaning with blower on moveable parts time to time
Testing of relay through secondary injection
Tripping testing of Breaker through over current and earth fault relay
Daily Check control wiring, TNC Switch and indicator lamp annunciator panel,Master tripe relay,REJ 601 relay in all respect.
Testing of IR value of Breaker's
Setting/Programming of protection relay in/c relay co-ordination as per load and also checking of relay characterictics and operating time.
Testing/Servive of Transformer's with cable, IR value of Transformer, cable & PI value,charging current
Checking of Earth Resitance value at the endof equipment
Providing Services for trouble shooting in case of problems with in short peiord and emergency call if required.
The item covered in CMC are detailed in Annexure-1
SCHEULE OF THE JOB :-
Engineer for 24 Hour operations : 1 Person at a time
Annual Maintenance of all Circuit breakers : 2 time in a year
Emergency Visit (Master technical Person's) : As and when required
Dehydration of Transformer oils : 1 Time in a year
Annexure-1
33KV VCB Panels 1- ICOG : 1 No.
33KV VCB Panels 1- IC+2-OG : 1 No.
33KV VCB Panels 1- IC+2-OG : 1 No.
Testing of 33/11 KV, Oil Type Transformers : 2 No.
11KV VCB Panels 2-IC+1 BC+8OG. : 1 No.
Testing of 11/.4 KV,Oil Type Transformers : 8 Nos.
DC Power Pack/ Battery Bank : 3 Set,
Interconnecting Power and Control Cable : 1 Lot
Earth Grid and earth Pits : 1 Lot.
Power Control Center (PCC) : 1 Lot.
COMMERCIAL TERMS
Providing manpower 24 - hour operation cum maintenance in/c emergency visit are the part of CMC
Maitenance of all Breaker,Panels, Realys and other allied equipment 33KV, 11KV, PCC Panel are the part of CMC
Replacement of Indoor Current Transformers cast resin (CT) ratio 200-400/5 amp installed 33kv panel: in case of damage up to 9Nos are the part of CMC
Replacement of Indoor Potential Transformers cast resin (PT) ratio 33kv/110volt installed 33kv panel: in case of damage up to 9Nos are the part of CMC.
Replacement of Indoor Current Transformers cast resin (CT) ratio600/400/200/5 amp installed 11kv panel: in case of damage up to 9Nos are the part of CMC.
Replacement of Indoor Potential Transformers cast resin (PT) ratio 11kv/110volt installed 11kv panel: in case of damage up to 9Nos are the part of CMC.
All control wiring and its interlocking with PCC Panel and calibration of relay setting are the part of CMC.
Providing & fixing spare part of the VCB 1250 amp. Make ABB model VD4- 33kv if any damaged i.e pole, Contact arm, contact insulator,Tulip or Jaw 14 fingure, Pole assembly, Tripping coil, Closing coil, TNC Switch etc. Are the part of CMC.
Maintenance of Transformer Oil Dehydration& Filtration, Silca gel etc. for all existing transformers are the part of CMC.
Replacement of Batteries for DC Power pack Bank are the Part of CMC.
OTHERS:-
EPF , ESI and Time to Time their saleries etc. of the employee are the personal responsibility of the concerned bidder.
Any electrical equipment shock hazards / Electrocution are the personal responsibility of the concerned bidder.
IS/IEC:-
Confidentiality & Impartiality :- Confidentiality & Impartiality shall be ,aintain for all work activities
Statement of Coformity :- The Result Conform to applicable IS/BIS Documents
Providing test report as per International standard IEC-17025.
Should be experience of 33kv and 11Kv automission electrical panel of HPSEB Ltd.
TILAK RAJ
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .