Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
ADDN ALTN TO MI ROOM BLDG NO P05 GROUND EQPT HANGER AT TECHNICAL AREA PROVN OF CERTAIN BR WORKS AT VARIOUS LOCATIONS AND PROVN OF GREASE TRAP ALUMINIUM JOINERY WORK FOR AIRMEN MESS AT 17 FBSU UNDER GE AF TRIVANDRUM
2022_MES_557507_2
8400
Open Tender
Civil Works
Item Rate
270 days
AF STATION TRIVANDRUM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF Trivandrum
₹48,800
Yes
31 Jan 2023
15 Dec 2022
23 Jan 2023
15 Dec 2022
18 Jan 2023
30 Dec 2022
Amount
Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc,
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings/ wall cladding etc complete all as specified and as directed.
Taking down chowkats with shutter any description (without taking off shutters from the frame) area exc. 1.5 Sq.m but not exc. 4 Sq.m each.
Taking down plastering on lathing/ walls (other than wire-netting), without removing lathing, in cement mortar(one side only measured in cases where both sides are plastered)
Surface excavation n. exc 30cm deep and averaging 15 cm and getting out in soft/loose soil
Excvn in trenches n exc. 1.5M wide and n exc. 1.5M in depth for foundation etc. and getting out in soft/loose soil
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil.
Removing excavated soil to a distance n.exc 50 M and despositing where directed at a level not exc 1.5 M above the starting point.
M&L Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L plain cement concrete in foundation filing and mass concrete in 1:4:8 type D2 (using 40mm graded stone aggregate)
M&L plain cement concrete in foundation filing and mass concrete in 1:2:4 type D2 (using 40mm graded stone aggregate)
Providing, cement concrete PCC type B1 1:2:4 20mm stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges as in platform to tank including formwork
Material and labour for cast in situ precast cement concrete road side kerb stone/ edging (incl formwork) of any size using PCC 1:2:4 type B0 as directed by Engg in charge , smooth finish and set in cement mortar 1:4 complete all as directed
M & L for RCC 1:2:4 B1(20 mm graded stone aggregate) nominal mix as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M & L for RCC 1:2:4 B1(20 mm graded stone aggregate) nominal mix as in Beams, cantilevers, bressummers, lintels over 1.5m span
M & L for RCC 1:2:4 B1(20 mm graded stone aggregate) nominal mix as in Columns, pillars, piers, posts and struts
M & L for RCC 1:2:4 B1(20 mm graded stone aggregate) nominal mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, completeType 1:3:6 using 20mm graded aggregate in CM 1:4
Use and waste of form work to side of concrete foundation/plinth beams/ lintel beams for rough finish concrete surface.
Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finish surfaces
M & L Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
M & L for Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns hooking ends and bending with and including mild steel wire not less than 0.9 mm dia or securing with clips.
All as per SI item No.24 above but with 5mm dia and over upto including 10mm dia in stirrups.
S & F for wind ties for roof incl securing bolts, cutting tops to shape as directed, incl all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M & L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; frame work for gates, portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc and similar work conforming to Fe.290.Gde-E-165
M & L for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc.Fe-410-W(Gde-E-250) quality-B
S & F mild steel frame work of angle/ tee/ square tube as in addn rafter/ purlines, crane gantries rails and fastenings and heavy bracket framing ( beams tee, angle, channel or flat sections) including distance pieces , cleats etc , Fe-290 (Gde E 165) comple all as spd & directed , .
S & F rolled mild steel work in tubular trusses including, special shaped washer etc. complete unsing ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240.
M & L for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows (sliding type) & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
M & L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Material & Labour for 2nd class hardwood Plain, solid, straight, as frames/ racks /chowkats wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as directed
M & L for applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified
M & L for Priming surfaces and applying normal treatment (for moderate conditions) using glass fibre base bitumen felt, grade 2
S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ wall cladding, fixed with self tapping screws as specified.
M & L for 25 mm thk Prelaminated particle board, exterior grade prelaminated both sides with decorative choice laminations fixed with screws to timber frame work as shelves
M & L for 75mm thk Cement concrete type B- 2,1:2:4 (40mm graded stone aggregate) as sub base to flooring complete all as spd & directed.
M & L for Virified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade (Note; screed bed / backing coat shall be measured separately)
M & L for coloured Glazed ceramic tiles in vertical surface 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with10 mm thick rendering in CM 1:4 as direced .Note; screed bed / backing coat shall be measured separately)
S & F sheet glass ordinary quality 4 mm thick and glazing with oil putty/glazing clips of any description.
M&L for 40mm thick PCC 1:2:4 type B1 (20mm graded aggregate as in flooring all as specified.
Material and labour 60mm thick coloured pre-cast (factory made) interlocking paver blocks manufactured from ordinary portland cement mixed with pigment strength minimum M-35 grade concrete , vibro-compacting, conforming to IS- 15658-2006, over 50mm thick sand filling as cushioning over 100mm thick (consolidated thickness) of PCC 1:4:8, type D-2 using 40 mm graded stone aggregate complete all as specified and as directed by Engr-in-Charge.
M & L for minimum 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in incl cement screed bed20 mm thick in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including provision of cement screed 20mm thick in CM 1:6
M & L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6
M&L rendering 10mm thick on fair faces of brick work or concrete surfaces thick in CM 1:6 surfaces finished fair and even.
M&L rendering 10mm thick on fair faces of brick work or concrete surfaces thick in CM 1:4 surfaces finished fair and even.
Preparation of newly plastered surface of walls and applying two coat of OBD on walls over a coat of primer
Preparation of newly plastered surface of walls and applying three coat of white wash on walls
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old prepared surfaces.(incl preparation to old surfaces)
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M & L for prepation of old steel surfaces of any description, exc 10cm in width or girth & applying one coat of synthetic enamel paint over a coat of redoxide primer incl preparation complete all as spd and directed.
M & L for prepation of old steel Surfaces of any description, n.exc 10cm in width or girth & applying one coat of synthetic enamel paint over a coat of redoxide primer incl preparation complete all as specified and directed.
M & L two coat of synthetic enemal paint on new steel surfaces of any description, over 10cm in width or girth,not otherwise described incl preparation of surfaces all as specified
Preparation of old wooden Surfaces over 10cm width or girth applying two coat of synthetic enamel paint over a coat of pink primer.
Preparation of new wooden Surfaces over 10cm width or girth applying two coat of synthetic enamel paint over a coat of pink primer.
Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified.
Supplying and laying of 25mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified.
S & F in repairs fancy type Pillar taps 20mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron /PPR pipes and fixed
S & F 1000 ltrs Rotational moulded polyethylene three layered water storage tanks (cylindrical vertical with closed top) three layers, hoisted and fixed in position all as specified in SSR Part-I , including float valves , inlet, outlet, overflow pipes and top cover complete all as specified.
M & L Aluminium anodised powder coated for door shutter side hung without sash bar aluminium section 0.55 kg/m includng necessary jointing, glazed clip joint cleats, rubber gaskets, including aluminium fittings dead lock 4 levers, two numbers of aluminium alloy anodised tower bolts , hinges, handles etc. includinjg fixing frame to wall members with rawl plugs complete. all as spd & directed by Engr in Charge.
Supply and fixing aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm fixed with aluminium wire staples or fixing with beads to joinery when fixed in panels of joinery, complete all as specified and as directed .
S&F Aluminium die cast body door closer for aluminium door shutter hydraulically regulated, designation No-3universal type, suitable for door shutters upto 700 mm in width and of weight not more than 35 kg and fixed. complete as specified and directed by Engr in charge.
S & F Polyproplene Grease trap of medium size of flow rate capacity 2500 to 3000 IP with inlet 100 mm dia pipe complete all as specified and directed by Engr in Charge.
Demolition of cement concrete ( unreinforced) in ground floor and paving n exc 15 cm thicikness ( below or above ground level) all as spd & directed
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius b built in CM (1:4) complete all as specified and as directed.
M&L for rendering 15 mm thick on fair face of brick work , concrete surfaces in cement mortar 1:4 finished even and smooth without extra cement complete all as specified.
S&F PVC (SWR) 110mm bore (dia) soil waste pipe, (ISI Marked), in any length with rubber ring joints fixed to walls , floor or in trenches with necessary stay clamps etc including necessary haunching / benching complete all as specifed .
Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, MCBs,light fitting etc. removing materials to store for keeping in safe custody or for taking creditand making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
M&L for point wiring with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multistranded copper conductor drawn in and including PVC conduit and all conduit accessories concealed and including provision of 1.5 sqmm PVC insulated copper cable FRLSH ISI marked as earth continuity conductor fabricated branded Modular metal flush box concealed in walls with Modular suitable pate with cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed for the following: -
One light point controlled by one switch
All as per item No 62.01 here in before but for one bell point controlled by one bell push.
All as per item No 62.01 here in before but for one ceiling fan/exhaust fan/wall mounting fan point controlled by one switch/ceiling fan regulator.
All as per item No. 62.01 here in before but for one 3 pin socket outlet 5 amp on the same board
All as per item No. 62.01 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 62 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
All as per Sl No 62 above but wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently.
M&L for sub main wiring with PVC insulated unsheathed FRLSH 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC rigid conduit and all accessories fixed concealed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor PVC conduit shall be measured as one length including taking down UNSV old wiring. Make:- Havells/ Polycab/ Plaza.
M&L for Switch modular type one way 6 Amps , one module. Make Legrand(Mylink)/equal to Anchor/SSK
M&L for Modular bell push 6A 1 module. Make Legrand(Mylink)/equal to Anchor/SSK
M&L for Modular socket 2/3 pin multi purpose flush type 2 modular 6 Amps. Make Legrand(Mylink)/equal to Anchor/SSK
M&L for Switch modular type one way 16 Amps , one module. Make Legrand(Mylink)/equal to Anchor/SSK
M&L for Modular socket flush type multi purpos 5A/16A-6 pin combined 2 module. Make Legrand(Mylink)/equal to Anchor/SSK
Supply & fix modular type fan step regulator 360 Degree rotatable type 120W - 2 Module. Make Legrand(Mylink)/equal to Anchor/SSK
M&L for Ceiling rose 65x50mm surface PVC / Polycarbonate, isolated body with three terminals. Make : Anchor/Legrand/SSK
M&L for bell AC 230 volts single pole. Make : Anchor/Legrand/SSK
Supply and fixing ceiling fans complete with blades,down rods and accessories,230V,1200mm sweep. Min air delivery 210 CFM with service value 6.00BEE. Five star rated with brushless direct current motor (BLDC). Make : Orient/Usha/Bajaj
Supply and fix exhaust fan,steel body AC single phase 230V of size 300mm sweep with blades and frame and louvers including cuttting hole for fixing exhaust fan and making the surface good with the existing. Make : Orient/Usha/Bajaj
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make : Crompton Cat Part No CCS-100-20-65-HL2-DP-NWH/ equivalent of Havells/Wipro
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Crompton Cat Part No CCS-102-10-65-SL-DP-NWH/ equivalent of Havells/Wipro
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Make : Crompton Cat Part No LCTLRNE-36-FO-CDL/ equivalent of Havells/Wipro
S&F in repair MCB DB with sheet metal enclosure double door type concealed on wall single pole and neutral 8 way 240V with 200A rated bus bar all as specified and directed. Make : Legrand/Indo Asian/Havells
S&F in repair MCB DB with sheet metal enclosure double door type concealed on wall Triple pole and neutral 4 way 415V with 200A rated bus bar all as specified and directed. Make : Legrand/Indo Asian/Havells
S&F in repair Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket ,240V complete with one single pole MCB of 25 A all as specified and directed. Make : Legrand/Indo Asian/Havells
Supply and fixing 40 to 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole and Neutral in the MCB DB complete with connection testing and commissioning. Make : Legrand/Indo Asian/Havells
Supply and fixing 5 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning. Make : Legrand/Indo Asian/Havells
Supply and fixing 40 to 100 Amp rating 415V, 10KA 'C' curve miniature circuit breaker (MCB) of Trible pole and Neutral in the MCB DB complete with connection testing and commissioning. Make : Legrand/Indo Asian/Havells
Fixing only 5 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB obtained from Item No 61 complete with connection testing and commissioning.
Fixing only 40 to 100 Amp rating 415V, 10KA 'C' curve miniature circuit breaker (MCB) of Trible pole and Neutral in the MCB DB obtained from Item No 61 complete with connection testing and commissioning.
Fixing only LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light obtained from Item No 61 here in before including connecting up by providing with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Fixing only LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size obtained from Item No 61 complete.
Labour only for removing of ceiling fan from ceiling by disconnecting all electric conection and spray painting in situ with one coat of synthetic enamel white paint,filling cavities with filler after cleaning all dust/foreign materials and hanging only after completion of E/M and B&R works and connecting up including provision of three core copper cable of suitable size from ceiling rose or connector to fan and testing as directed by engr-in-charge.
M&L for Spary Painting of exhaust fan in situ with one coat of synthetic enamel paint,filling cavities with filler after cleaning all dusts/foreign materials all as directed and specified.
Fixing only in repair MCB DB with sheet metal enclosure double door type concealed on wall Triple pole and neutral 4 way 415V with 200A rated bus bar all as specified and directed.
DEFT GROUP ELECTROMECHANICAL
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .