Executive Engineer ED Baramulla
Executive Engineer ED Baramulla
Providing of Power Supply to under construction ACB Police Station by way of creation of 400kVA substation at Kanispora of ESD Baramulla 1st under DC Head.
2024_PDD_252594_2
EDB/03 of 2024-25
Open Tender
Electrical Works
Turn-key
45 days
Kanispora Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,001
Yes
Executive Engineer ED Baramulla
₹44,500
Yes
9 Aug 2024
11 Jul 2024
31 Jul 2024
11 Jul 2024
30 Jul 2024
11 Jul 2024
11 Jul 2024 - 11 Jul 2024
Amount
Supply,Carraige upto site, Installation, testing and Commissioning of 11/0.433kV, 400kVA 3-Phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Copper wound) and with LV Cable Box having detachable Alminium Gland plate Transformer should have arrangements for vertical take off cable with OCTC.
Supply,Carraige upto site, Erection, testing and commissioning of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long )
Supply, Carriage up to site, Erection, testing and commissioning of Steel Tubular Pole, 8 Mtr. Long Pole(SP15) with planting depth of 1/6 the of the height of the pole, (8 mtr. Long )
Supply, Carriage up to site, laying ,stringing, tensioning , binding of ACSR Conductor, (30mm2 ACSR Conductor)
Supply,Carraige upto site, Installation, testing and Commissioning of G.I Channel / Angle / Flat of sizes including Clamps as per approved Drawings
Supply,Carraige upto site, Installation, testing and Commissioning of G.I Channel V-X arms 75x40x6mm with Top bracket including suitable clamps/collars as per approved Drawings
Supply,Carraige upto site, Installation, testing and Commissioning of 120mm² AB (LT) Cable (3 X 120 + 1 X 25 + 1 X 95mm²) XLPE (1.1kV, 3 + 1C, Al)
Supply,Carraige upto site, Installation, testing and Commissioning of Insulating Piercing connectors
Supply,Carraige upto site, Installation, testing and Commissioning of Suspension / Tension clamps with eye hook
Supply,Carraige upto site, Installation, testing and Commissioning of Service Mains Distribution Box containing Circuit Breaker 63 Amp 4 pole MCCB 415V/1100 V, 3ph, 35KA , 4 No. 32 Amp 1-P MCB, (of reputed make) enclosed in sheet steel cabnet, powder coated, RYBN bus bars with epixoy coating, locking arrangment etc including collars 2 No of 50x6mm flat iron as per approved drawing (Sample to be approved before installation)
Supply,Carraige upto site, Installation, testing and Commissioning of Transformer Pad/G.I Channel bedding/ G.I Pipe of 150mm Dia for construction of transfomer Bed as per approved Drawings
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV Polymeric composite Pin Insulators 12kV, 5kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV Polymeric composite disc insulators 12kV, min falling load 45kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm (1Set=3Nos.)
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV G.O, AB switch 3-phase, 3pole,200Amp, vertical type
Supply,Carraige upto site, Installation, testing and Commissioning of 11kV Horn Gap Fuse Set 3 Phase 200A
Supply,Carraige upto site, Installation, testing and Commissioning of 11kV Gapless surge arrestor, 9 kV, 10kA, LA with polymer housing station type
Supply,Carraige upto site, Installation, testing and Commissioning of Outdoor Type LT Distribution Box for 400kVA DTR with 630Amp MCCB 3P 36kA adjustable 1no. for incomer & 200Amp MCCB 3P 16KA 4Nos. fixed for outgoing circuit as per approved drawing (Sample to be approved before installation)
Supply,Carraige upto site, Installation, testing and Commissioning of 400sqmm Single core cable 1.1kV Grade XLPE insulated Stranded conductor FRLS type
Supply,Carraige upto site, Installation, testing and Commissioning of Galvanised stay set with 50X8mm stay clamp, guy insulator (02nos), anchor plate (200X200X6)mm nut bolts, 02nos turn buckle, 1.8m long, 16mm diameter solid GS stay rod & 7/3, 15mm dia GI stranded wire complete
Supply,Carraige upto site, Installation, testing and Commissioning of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm
Supply,Carraige upto site, Installation, testing and Commissioning of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc.
Supply,Carraige upto site, Installation, testing and Commissioning of Galvanised Nuts & Bolts
Supply,Carraige upto site, Installation, testing and Commissioning of Wedge connector / PG Clamps
Supply,Carraige upto site, Installation, testing and Commissioning of Earthing of Sub Station --Excavation of earth pit dia 650mm & depth 3000mm, installation of earthing pipe pf 40mm nominal bore & 4mm wall thickness & length 2.5mtr long as per IS 1239. GI strip for neutral earthing of size 25mmX3mm for connection of transformer body, GO set & lightening arrestors as per IS 2629/85, GI nut & bolts refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.
Supply,Carraige upto site, Installation, testing and Commissioning of Cement bottoming 1:2:4 as per standards 0.5cum / pole
Supply,Carraige upto site, Installation, testing and Commissioning of Cement bottoming 1:2:4 as per standards 0.45cum / pole
Supply,Carraige upto site, Installation, testing and Commissioning of Cement bottoming 1:2:4 as per standards 0.45cum / pole for GI Pipe of Transformer Bed
Providing & Painting of Poles with one coat of Red Oxide and two coats of aluminium paint
Supply,Carraige upto site, Installation, testing and Commissioning of Danger Plate with clamps
Supply,Carraige upto site, Installation, testing and Commissioning of Anti climbing device with clamps
Supply,Carraige upto site, Installation, testing and Commissioning of GI Barbed wire for anti climbing
Supply,Carraige upto site, Installation, testing and Commissioning of 11 KV HT Tri-Vector meter consists of followings units. 1. 3Ph 3 Wire HT CT/PT operated,11kV/110V Tri-Vector Energy meters DLMS Compliant Category 'C' with RS 232 port for modem compatibility. (make L&T, Secure, ABB). 2. Epoxy resin Cast Current Transformers suitable for 11kV with CTR 25/5 A, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. 3. 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II). 4. 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for outdoor as per the site requirement. 5.3 Core 11 kV Aluminium cable XLPE armoured 35 Sq mm (20 Mtr) along with suitable Haet Shrinkable Cable termination kits suitable. 6. Earthing (01 No.) by way of 40 mm GI Pipe earthing . Job includes , excavation, enhancement materail and Main Hole Chamber (500x450x600)mm with frame and cover. The Earthing Pipe to be connected through 25X3 mm GI Strip. Further all other Misc items like Copper Lugs, Connecting Wires, Tape Etc are also included.
Supply, Carriage up to site, Installation, of Sign Board (2X2 feet) along with required accessories like clamps, nuts and bolts etc.
M/S R R ELECTRICAL SERVICES
M/S BILAL ELECTRICALS
ALIF INFRAPROJECTS PVT LTD
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .