| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAdmitted-Finance | ₹7.0 L | L1 | Admitted-Finance |
| 2 | L2₹7.1 L+₹2,400 (0.34%)Admitted-Finance | ₹7.1 L+₹2,400 (0.34%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AL-AWAAL BUILDERS AND DESIGN PVT LTD L1 | Sheikh Ul Alam Electricals And Suppliers Pro Irfan Shakeel L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of GI Steel Structures of Various Sizes of various sizes including clamps as per approved IS/drawings/standards (MT- Metric Ton) | 1.2 | MT | 1,48,000 ₹1,77,600 Lowest | 1,50,000 ₹1,80,000 |
| 2.00 | Supply, Carriage upto site (including Loading/Unloading), Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (150 Sqmm ACSR Conductor-Wolf) as per approved drawings/standards | 1.5 | Km | 1,80,000 ₹2,70,000 Lowest | 1,80,000 ₹2,70,000 Lowest |
| 3.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Galvinized Nuts and Bolts as per approved drawings/standards | 250 | Kg. | 280 ₹70,000 Lowest | 280 ₹70,000 Lowest |
| 4.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of PG/T Clamps suitable for 150 Sqmm ACSR as per approved drawings/standards | 6 | No. | 500 ₹3,000 Lowest | 500 ₹3,000 Lowest |
| 5.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm (reputed make) as per approved drawings/standards | 3 | No. | 1,500 ₹4,500 Lowest | 1,500 ₹4,500 Lowest |
| 6.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting (reputed make) as per approved drawings/standards | 6 | No. | 1,500 ₹9,000 Lowest | 1,500 ₹9,000 Lowest |
| 7.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm as per approved drawings/standards | 2 | No. | 1,500 ₹3,000 Lowest | 1,500 ₹3,000 Lowest |
| 8.00 | Dismantalling of Existing Damaged Gantry in all respects (MT- Metric Tons) | 5.3 | MT | 10,000 ₹53,000 Lowest | 10,000 ₹53,000 Lowest |
| 9.00 | Fixing of Dismantalled Steel Structure as per approved IS/drawings/standards (MT- Metric Ton) | 5.3 | MT | 10,000 ₹53,000 Lowest | 10,000 ₹53,000 Lowest |
| 10.00 | Providing & Painting of Dismantalled Steel Structure with one coat of Red Oxide and two coats of aluminium paint and as per approved drawings/standards | 1 | Job | 50,000 ₹50,000 Lowest | 50,000 ₹50,000 Lowest |
Tender Value
₹7.1 L
EMD Value
₹14,146
Closing Date
3 Apr 2026, 2:00 pmClosed
EXECUTIVE ENGINEER STD Sopore
EXECUTIVE ENGINEER STD Sopore
Repairing/Rebuilding of damaged Gantry Structure installed on river crossing span of 33 KV Amargarh-Arampora Line
2026_PDD_304445_1
STDS/ 34 of 2025-26
Open Tender
Electrical and Maintenance Works
Turn-key
30 days
STD Sopore
Please refer Tender documents.
5 documents required · 5 mandatory
₹508
Yes
Executive Engineer STD Sopore
₹14,146
Yes
21 Apr 2026
25 Feb 2026
4 Apr 2026
25 Feb 2026
3 Apr 2026
28 Feb 2026
25 Feb 2026 - 28 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of GI Steel Structures of Various Sizes of various sizes including clamps as per approved IS/drawings/standards (MT- Metric Ton) | 1.2 | MT | 1 | ₹1.2 |
| 2 | Supply, Carriage upto site (including Loading/Unloading), Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (150 Sqmm ACSR Conductor-Wolf) as per approved drawings/standards | 1.5 | Km | 1 | ₹1.5 |
| 3 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Galvinized Nuts and Bolts as per approved drawings/standards | 250 | Kg. | 1 | ₹250 |
| 4 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of PG/T Clamps suitable for 150 Sqmm ACSR as per approved drawings/standards | 6 | No. | 1 | ₹6 |
| 5 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm (reputed make) as per approved drawings/standards | 3 | No. | 1 | ₹3 |
| 6 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting (reputed make) as per approved drawings/standards | 6 | No. | 1 | ₹6 |
| 7 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm as per approved drawings/standards | 2 | No. | 1 | ₹2 |
| 8 | Dismantalling of Existing Damaged Gantry in all respects (MT- Metric Tons) | 5.3 | MT | 1 | ₹5.3 |
| 9 | Fixing of Dismantalled Steel Structure as per approved IS/drawings/standards (MT- Metric Ton) | 5.3 | MT | 1 | ₹5.3 |
| 10 | Providing & Painting of Dismantalled Steel Structure with one coat of Red Oxide and two coats of aluminium paint and as per approved drawings/standards | 1 | Job | 1 | ₹1 |
stage.html
html • 0.03 MB
techsummary_988924.pdf
BOQ Comparative Chart
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_988924.xls
BOQ • 0.33 MB
Drawings.pdf
Tender Documents • 0.06 MB
SBD34.pdf
Tender Documents • 1.46 MB
Extension34-III.pdf
PDF • 0.22 MB
Extension34-II.pdf
PDF • 0.22 MB
Ext34.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .