Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.2 LAccepted-AOC 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | 1 | Accepted-AOC ACCEPTED BEING THE LOWEST TENDERER | |
| 2 | 2₹7.9 L+₹30,510 (4.03%)Rejected-Finance DOOR NO 44 19 10 RAILWAY NEW COLONY BEHIND SIVALAYAM VISAKHAPATNAM AP 530016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | 2 | Rejected-Finance REJEDTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹8.3 L+₹71,045 (9.39%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹10.3 L+₹2.7 L (36.2%)Rejected-Finance | 4 | Rejected-Finance REJEDTED NOT BEING THE LOWEST TENDERER | |
| 5 | Rejected-Technical D NO 1 2 86 AKKIREDDYPALEM WARD 65 BHPV PEDAGANTYADA VISAKHAPATNAM 530 012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | - | Rejected-Technical VERIFIED AND REJECTED AS THE FIRM IS NOT ENLISTED WITH REQUISITE CATEGORY AS DETAILED IN NIT |
Tender Value
Refer Docs
EMD Value
₹19,940
Closing Date
10 Jun 2021, 6:00 pmClosed
AGE I CG VIZAG
AGE (I) (CG) Vizag Military Engineer Services CGWO Malkapuram
COMPREHENSIVE MAINTENANCE OF INTERNAL WIRING LIGHT FITTINGS AND FIXTURES FOR CG COMPLEX MALKAPAURAM CG JETTY AND CG COMPLEX RISHIKONDA UNDER AGE I CG VIZAG
2021_MES_442427_2
AGE(I)CG/VIZ/TOKEN 16 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) (CG) VIZAG
₹19,940
Yes
11 Sept 2021
19 May 2021
12 Jun 2021
19 May 2021
10 Jun 2021
27 May 2021
Amount
Receiving complaints from concern incharge of Internal section (Power House) lodged by the occupants of electrification nature, rectification of the fault as per the complaint lodged by the user onward KWH meter in respect of main distribution board having switch fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan/bell/light/Ceiling Fan, testing of Electronic meters or power socket complete, repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, suck boxes, juction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/exhaust fans and other connected fixtures of the internal electrification including supply of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tap, screws, nuts as required to rectify the fault with regard to the complaint lodged and refixing of fittings/fixtures to their original position where dismantled complete all as directed at site to the entire satisfaction of Engineer-in-charge / users.
Notes for item No. 01 above - (i) All spares required i.e. tube light any type, Choke any type, CFL, starter, bipin holder, starter holder etc. accessories, required for repairing will be paid under relavent supply only items of this schedule. I(ii) Attending complaint including taking down/refixing of LED light fittings and repair part (Labour ) and minor repair shall be measured against Srl item No 1 of BOQ. (iii) Cost of material and labour for replacement of new items shall be measured and paid separetely under relevent items of sch "A" against supply only here-in-after. (iv) Penalty : Penalty for not attending complaints within stipulated time frame will be the liable upto Rs 500.00 of per day for non attending the complaints multiple number of days. (v) Complaints of Priority -1 To be done within 8 hours from time of lodging complaint. No light,repair/replacement of switches, fan regulator, replacing burnt/damaged wiring, replacement of burnt MCBS and Main switch, voltage fluctuation, current leakage and replacement of tube lights shall come under Priority -1. (vi) Complaints of Priority -2 To be done within 72 hours from time of lodging complaint. Replacement of fittings and fixtures replacement of choke starter replacement of meter,replacement of DBs and Main DB, repair of earthing lead etc. shall come under Priority -2
Notes for item No. 01 above (Contd….) - (vii) Complaints of Priority -3 To be done within 07 days from time of lodging complaint. Replacement of fittings and fixtures, Ceiling Fan, Call bell switch board, point wiring etc. shall come under Priority -3.
Contractor shall employ suitable tradesman having sufficient experience of Electrician work with suitable helpers to rectify the inetrnal electricfication defects, Breakdown Current leakage, Replacement of Electrical items, wiring work, electronic meter testing Etc.
The quantum of work under a complaint shall be comprised as Each Qtr/ complaint nature issued with unique docket No. and the contractor have to provide printed complaint slip book in which Job Card No. should be serially numbered.
Supply only following items :-
Switch piano 5 Amps
Switch Socket Combination 5 Amps 5 Pin universal type
Switch Socket Combination 15 Amps 5 Pin multipurpose
LED Bulb cool white 1 x 4-5 W , 230 V.
LED Bulb cool white 1 x 8-9 W , 230V.
LED Bulb cool white 1 x 14 W , 230V.
LED Bulb cool white 1 x 20 W , 230V.
Electronic ballast 1 x 28 W , 230 V.
Electronic ballast 1 x 36 W, 230 V.
Electronic ballast 1 x 18/20 W 230 V.
Heavy duty VPIT copper ballast for FTL 40 Watt.
Heavy duty VPIT copper ballast for FTL 18/20 Watt.
Bipin Holders
Side base suitable for single tube, tube light fittings.
Side base suitable for double tube, tube light fittings.
Starter holder.
Starter 20/40W, 230V.
S&F switch Piano 5 Amp, one way complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S&F switch Piano 15 Amp, one way complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S&F Mega bell push Piano 5 Amp, complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S&F socket outlet 3 pin, 5 Amps, complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S&F socket outlet 3 pin,5/15 Amps,complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S & F of 15 mm PVC Saddle made of good quality of PVC with MS screws- 02 and central fastening screw complete all as specified and as directed.
S & F of 20 mm PVC Saddle made of good quality of PVC with MS screws- 02 and central fastening screw complete all as specified and as directed.
S & F of 25 mm PVC Saddle made of good quality of PVC with MS screws- 02 and central fastening screw complete all as specified and as directed.
S & F in repairs of three pin male socket single phase 230 Volts -5 Amps ( ISI Marked) complete all as specified and as directed.
S & F in repairs of three pin male socket single phase 230 Volts -15 Amps ( ISI Marked) complete all as specified and as directed.
S & F in repairs of Capacitors of 2.5 mfd single phase 230 Volts complete all as specified and as directed.
S & F in repairs of Capacitors of 1.5 mfd single phase 230 Volts complete all as specified and as directed.
S & F in repairs , table mounted straight mutliplug 3 x 5 / 15 A universal made in PVC body with 3 pin Plug top & chord complete all as specified and as directed.
Taking down old unserviceable / deteriorated batten / PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surfaces of wall, floor etc all as required and as directed by Engineer-in-Charge.
M & L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade (ISI marked) not less than 19 mm dia/ Casing caping of 19-20 mm with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc. including anodized standard sunken boxes as per standards as per manufacturer norms for concealed mounting with earth dolly and standard grid, crown and cover plate for fixing of switches / sockets, fan regulators, with captive screws including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing, including cutting the chasses for fixing of wiring conduit as per conduit size not more the 25 mm deep and 30 mm in width and making good the disturbed surfaces by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/ Putty or distemper / colour wash with same existing colour surfaces all as specified and as directed by Engineer-in-Charge for one light/ fan/ call bell/ 5 Amp independent socket point controlled by one switch. Note : The cutting chiseling and making good item will be excercised when wiring to be concealed.
-Ditto- all as per item No 17 here-in-before but For one socket point controlled by one switch on same board.
All as per item No 17 here-in-before but for power point wiring with 4 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 S qmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and as directed.
All as per item No 17 here-in-before but in exsiting concealed/surface PVC conduit for the following :- For one light, fan, call bell, 5Amp independent socket point controlled by one switch.
All as per item No 17 here-in-before but in exsiting concealed/surface PVC conduit for power point wiring with 4 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S & F Modular Switch flush type, Single pole one way 5 Amps, 240 volts, white finish complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S & F in repairs for Modular switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
M&L in repairs for modular socket outlet 5 pin, 6 Amps flush type white finish complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S&F in repairs modular socket outlet 2 in 1, 3 pin, 16 Amps, flush type universal, 240 Volts white finish complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S & F in repairs modular bell push, flush type 5 Amps white finish complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS
S&F in repairs modular electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified and as directed. Make : Havells / Anchor / Legrand / Schneider or equivalent in makes specified in PS.
S & F in repairs, Calling Bell, musical 230 Volt, AC complete all as specified and as directed.
S & F in repairs, Ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and as directed.
S & F in repairs, lamp holder insulated body with back plate suitable for angle / batten fitting complete all as specified and as directed.
M&L for Sub main wiring with two runs of 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor cable drawn in MS/PVC conduit with one run of 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid PVC conduit ( ISI marked) of size not less than 20 mm dia in concealed /surface wiring inclusive all fitting such as Tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc. fixed properly including taking down old unserviceable sub main wiring complete all as specified and as directed. Make of wire: Polycab/Havells/Gloster/Finolex
M&L sub main wiring with two runs of 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor cable drawn in MS/PVC conduit with one run of 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid PVC conduit (ISI marked) of size not less than 25 mm dia in concealed / surface wiring inclusive of all fittings such as Tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc. fixed properly including taking down old unserviceable submain wiring complete all as specified and as directed. Make of wire: Polycab/Havells/Gloster/Finolex
M&L for Energy saver LED batten fitting 20 watt, 230 Volts, single tube mounting including with electronic driver, LED Printed board, end cover, connector box etc. and accessories, pre-wired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to LED light fitting including takingdown of old lights complete all as specified and as directed. Make: Philips/Wipro/ Havells or equivalent in makes specified in PS
M&L for energy saver LED batten fitting 10 Watt, 230 Volts, single tube mounting including with electronic driver LED Printed board, end cover, connector box etc. and accessories, pre-wired, LED including required fixing arrangements and electrical connection two core 1.5 Sqmm copper cable from ceiling rose to led light fitting, including takingdown of old lights all as directed. Make: Philips/Wipro/ Havells or equivalent in makes specified in PS
S & F decorative CFL luminary suitable for wall mounting 15 watt retrofit CFL complete with 15 watt, lamp holder complete made up of polycarbonate including fixing arrangements and taking down old rusted bracket light fittings including takingdown of old lights complete all as specified and as directed. Make: Philips/Wipro/ Havells or equivalent in makes specified in PS
S & F in repairs LED luminaire 600 mm x 600 mm, 35 / 36 watt, 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. Make: Philips/Wipro/ Havells or equivalent in makes specified in PS
S & F in repairs round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make: Philips/Wipro/ Havells or equivalent in makes specified in PS
S & F in repairs double door metallic sheet metal enclosure for DBs when MCBs to be used TPN , 4 ways, 415 Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs double door metallic sheet metal enclosure for DB when MCBs to be used SPN 2 ways, 240 V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs testing and commissioning of MCB SP 240 volt 6 Amp to 32 Amp 10 KA capacity having C - curve characteristics connected with suitable lugs complete all as specified and as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs testing and commissioning of MCB SP 240 volt 40 Amp to 63 Amp 10 kA capacity having C - curve characteristics connected with suitable lugs complete all as specified and as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs testing and commissioning of MCB SPN 240 volt 16 Amp to 32 Amp 10 kA capacity having C - curve characteristics connected with suitable lugs complete all as specified and as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs testing and commissioning of MCB SP 240 volt SPN 40-63 Amp 10 kA capacity having C - curve characteristics connected with suitable lugs complete all as specified and as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs testing and commissioning of MCB TP 40 - 63 A 415 V capacity having C - curve characteristics connected with suitable lugs complete all as specified and as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
S&F in repairs testing and commissioning of MCB TPN 40 - 63 A 415 V capacity having C - curve characteristics connected with suitable lugs complete all as specified and as directed. Make - Legrand/Scheinder/L&T or equivalent in makes specified in PS
ANJALI ENTERPRISES
SAMPATH ENTERPRISES
BHARGAVI ENGINEERING CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .