| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.0 L+₹37,083.50 (14.2%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹3.5 L+₹92,763.50 (35.5%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹3.5 L
EMD Value
₹6,936
Closing Date
14 Nov 2022, 11:00 amClosed
2 IC ELECT EE ELECT FTR HQ GUJ
2 IC ELECT EE ELECT FTR HQ GUJ
ARM REPAIR AND MAINT ELECTRICAL INSTALLATION OF GOVT BUILDINGS RESIDENTIAL COMMA NON RESIDENTIAL AT SHQ BSF GNR FOR SOS MESS COMMA JAWAN BK COMMA MT AND ADM BLOCK
2022_BSF_722309_1
15/2IC(ELECT)/NIT/FTR-GUJ/2022
Open Tender
Electrical Works
Item Rate
90 days
DIG SHQ BSF GNR
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹6,936
29 Nov 2022
8 Nov 2022
15 Nov 2022
8 Nov 2022
14 Nov 2022
8 Nov 2022
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.Group B
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3x1.5 sq mm
3 x 4 sq. mm
Suppling and fixing of metel box of following size (nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
150 mm X 75 mm X 60 mm deep
180 mm X 100 mm X 60 mm deep
200 mm X 125 mm X 60 mm deep
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc as required
5/6 amps Switch
3 pin 5/6 amps socket outlet
15/16 amps Switch
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Anchor/standard/ Havells/ Philips or equivalent make
Supplying and fixing of double module stepped type electronic fan regulator 14502 Make Anchor Penta on the existing Phanolic laminated plate switch box including connections but excluding Phanolic laminated plate etc. as required.Anchor/standard/ Havells/ Philips or equivalent make
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing of 03 mm, following size Phanolic laminated sheet i/c making holes, and fitted with cadmium screw with washer on existing board.Make-Havells/Anchor
09x11 inch
08x5 inch
4x4 inch
Supplying and fixing call bell/ buzzer suitable for single phase,230 volts, complete as required
Providing , Installation of heavy duty exhaust fan 300 mm(Metal body) sweep 900 RPM, Model-Turbo Force SP Make-Havells, in existing opening for suit the size of above fan, making good the damage, connection, testing, commissioning etc as required Make Bajaj/CG/Havells.
Supplying and fixing Energy saving new generation 10W LED,HEXA 10 W - IP66 bulkhead Model No- HEXAFT10WLED857SSYMBOPC Make Havells luminaire in Plastic body directly on wall i/c making connection with 1.5 sq mm FR PVC insulated copper conductor single core cable etc. as required or equivalent PHILIPS/Havells/Crompton
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. A) 6 Module (200mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
A) 5/6 A switch
B) 3 pin 5/6 A socket outlet
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, installation, testing and commissioning of 20 watt LED tube fittings prewired for LED tube, complete with all accessories and LED tube directly on ceiling/ wall including connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Cat No. REGALBATTENT 8UPTO1X22WSSBSWH & PHOTONULTRAE 2.01213T8SSTL20WLED865SPC) Retrofit Havells or its equivalant Philips/CG/Bajaj make)
Supply and fixing of 6 watt white light LED Unique Slimmest recess com surface panel with integrated electronic driver in ceiling complete with all accessories including connections etc. as required. (Comet ROUND Cat. No. LHEAABP7IL1W006 Havells make /CG/Philiphs or it's similer make as approved by engg incharge.)
Supply and fixing of four Pin18 watt, 6500 K, LED PLL Lamp in Existing Fittings Havells make /CG/Philiphs or it's similer make as approved by engg incharge.)
Providifg and fixing of wall mounting vertical water heater/geyser 25 litres, Product code-GHWAMGSIB025, Ivory, 2 KW, Make-Havells including testing, commissioning etc as required make Havells/Crompton/Hindware/Racold/Usha or equivalent
Prakash Electricals
M/S Taral Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .