The project involves UGT and OHT for Khadi Textile, Rural and Chemical Bio-Processing Building, Auditorium Building and Rural Craft and Engineering and Rural Energy and Infrastructure Building, Modular LED panel screen, SITC of complete 11 kV 0.433 kV substation including HT panel, transformer, HT LT cabling, bus trunking, LT and APFC panels, active harmonic filters, TVSS SPD, earthing, safety equipment and all interconnections, complete in all respects, Sewage treatment Effluent Treatment Plant STP and ETP, Solar Photo Voltaic Power Generation System, Acoustics and stage Works, Stage Lighting Works, Stage Drapery Works, Auditorium Carpeting, Auditorium Furniture Audio System Works
NBCC/SBG/NAG/MGIRI/NIT/2026/03~EWa431db70a3c681cf0f303246
NBCC/SBG/NAG/MGIRI/NIT/2026/03
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹11,800
₹3.5 L
8 Oct 2026
8 Oct 2026
15 Oct 2026
8 Oct 2026
15 Oct 2026
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked
materials. Ordinary or hard rock.
Providing and laying in position cement concrete of specified grade excluding the cost of centering
3 4.1.8 and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from Cum 8.31 6812 56,607.72
natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level.
Concrete of M30 grade with minimum cement content of 350 kg /cum.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations,
footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any
thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors,
roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams,
plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and
breaks in floors and walls. Above 20 cm wide.
11 13.3.1 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand). Sqm 144.2 471 67,968.67
Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing
treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant
slab, warehouses floor, parking structures and water tank base slab etc. sprinkled @0.60 kg per sqm
or higher as recommended by the manufacturer’s specification over the lean concrete of above cited
structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing
permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant
to 16 bar hydrostatic pressure on negative side. The crystalline dry-shake shall be capable of self-
healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per
specification and the direction of the Engineer-in-charge. The product performance shall carry
guarantee for 10 years against any leakage.
Common DSR description for item 22.23 reproduced below, followed by: For vertical surface two coats
@ 0.70 kg per sqm per coat.
Common DSR description for item 22.23 reproduced below, followed by: For horizontal surface one
coat @1.10 kg per sqm.
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport
15 2.25(a) upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in Cum 189.57 701 1,32,793.79
foundation trenches, plinth, sides of foundation etc. complete for all lift.
Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (heavy duty)
the weight of the cover to be not less than 108 kg.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &
cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including testing of joints complete as per direction
of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25
mm nominal dia Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &
cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including testing of joints complete as per direction
of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32
mm nominal dia Pipes.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/
19 22.4.1 expansion joints between two RCC members and fixed to the reinforcement with binding wire before m 62 328 20,314.30
pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick).
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and
approved quality. HD-20—Circular shape 560 mm internal diameter.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and
21 10.25.2 applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, kg 81 173 13,971.28
frames, guard bar, ladder, railings, brackets, gates and similar works.
22 17.56.1.1 Providing and fixing terminal guard: 100 mm—Sand cast iron S&S as per IS:1729. each 2 442 884.00
Digitally signed by RAKESH
Rural Craft & Engineering & Rural Energy & Infrastructure Building UGT for Fire & Domestic -
66 KL (Fire - 60 KL & Domestic - 6 KL)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked
materials. Ordinary or hard rock.
Providing and laying in position cement concrete of specified grade excluding the cost of centering
25 4.1.8 and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from Cum 3.87 6812 26,362.44
natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level.
Concrete of M30 grade with minimum cement content of 350 kg /cum.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations,
footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any
thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors,
roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams,
plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and
breaks in floors and walls. Above 20 cm wide.
33 13.3.1 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand). Sqm 77 471 36,293.95
Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing
treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant
slab, warehouses floor, parking structures and water tank base slab etc. sprinkled @0.60 kg per sqm
or higher as recommended by the manufacturer’s specification over the lean concrete of above cited
structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing
permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant
to 16 bar hydrostatic pressure on negative side. The crystalline dry-shake shall be capable of self-
healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per
specification and the direction of the Engineer-in-charge. The product performance shall carry
guarantee for 10 years against any leakage.
Common DSR description for item 22.23 reproduced below, followed by: For vertical surface two coats
@ 0.70 kg per sqm per coat.
Common DSR description for item 22.23 reproduced below, followed by: For horizontal surface one
coat @1.10 kg per sqm.
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport
37 2.25(a) upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in Cum 107.61 701 75,380.81
foundation trenches, plinth, sides of foundation etc. complete for all lift.
Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (heavy duty)
the weight of the cover to be not less than 108 kg.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &
cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including testing of joints complete as per direction
of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25
mm nominal dia Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &
cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including testing of joints complete as per direction
of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32
mm nominal dia Pipes.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/
41 22.4.1 expansion joints between two RCC members and fixed to the reinforcement with binding wire before m 41 328 13,433.65
pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick).
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and
approved quality. HD-20—Circular shape 560 mm internal diameter.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and
21 10.25.2 applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, kg 81 173 13,971.28
frames, guard bar, ladder, railings, brackets, gates and similar works.
22 17.56.1.1 Providing and fixing terminal guard: 100 mm—Sand cast iron S&S as per IS:1729. each 2 442 884.00
TOTAL FOR UNDERGROUND WATER TANK WORKS 14,13,512.94
Transformer & Associated Items
Digitally signed by RAKESH
Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 3 Star
rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step
down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound
transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain
Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with Offload Tap
Changer/ On Load Tap Changer (OLTC) ( below 500 KVA offload and above 500 KVA On Load Tap
Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic
sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual
operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV
side suitable for 3x300 sq.mm XLPE cable of 11 KV grade, including bus trunking arrangement on LV
side including supplying and laying of copper conductor multicore control cable from transformer to HT
23 24.7.6 breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant
IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S.
Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS :
1180 and as per CPWD specifications complete in all respects etc as required at site. The maximum
flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux
density with + 12.5 percent combined voltage and frequency variation from rated voltage and
frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 °C for oil
and 40 °C up to 200 KVA and 40 °C for oil and 45 °C for above 200 KVA for winding. Inside of tank
shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting
powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be
used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive
For highly polluted atmosphere and special application external paint work shall be as per direction of
Engineer-in-Charge. Design ambient condition : a) air temperature 50 °C, b) Relative Humidity 90 %
Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not
exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA
standard. The transformer should have QR code which should contain drawing, test report OEM
manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with
rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body,
easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked.
Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the
earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating
temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking
plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably
steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes
having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i)
Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief
device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for
transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m)
Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of
the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p)
Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature
indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping
mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA);
t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for
transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting
pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z).
Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level Each 1 1061164 10,61,164
indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above.
bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. 630KVA
Supplying, installing, testing and commissioning an outdoor four-way, SF₆-insulated Ring Main Unit
for an 11 kV system, 12 kV class, comprising two 630 A ring-feeder load-break switch-disconnector
ways and two outgoing vacuum circuit-breaker ways, with outgoing current ratings suitable for the
connected transformers/feeders as approved in the SLD; 630 A copper busbars; earthing switches;
protection CTs; numerical overcurrent and earth-fault protection with reliable self-powered or
approved auxiliary-powered tripping arrangement; operating mechanisms; safety interlocks; voltage-
presence indication; cable compartments; gas-pressure indication; internal earthing bus; and
24 Non-DSR weatherproof enclosure. Rated short-time withstand not less than 20 kA for 3 seconds, VCB short- Each 1 1062000 10,62,000
circuit breaking capacity not less than 20 kA and peak-making duty not less than 50 kA, or higher
ratings required by approved fault calculations. Outer enclosure minimum IP54 with doors closed and
sealed main tank minimum IP67. Complete with applicable type-test reports, routine tests, protection-
setting verification and commissioning, conforming to applicable IS/IEC standards and MSEDCL
requirements for the approved scheme. Excluding external HT cables, termination kits/connectors,
civil foundation and external earthing system, measured separately.
Supplying, installing, testing and commissioning an 11 kV, 12 kV class, 400 A, triple-pole, gang-
operated outdoor air-break switch with porcelain post insulators, rated 16 kA for 1 second short-
time withstand and 40 kA peak withstand, suitable for the approved installation fault duty. Complete
with contacts, galvanised supporting frame, operating linkage and pipe/rod, manual operating
mechanism, padlocking arrangement in open and closed positions, mounting brackets, hardware and
equipment earth connections, conforming to the applicable MSEDCL AB-switch specification and
approved drawings. Including suitably rated supporting poles, cross-arms, bracing, pole erection and
RCC foundations, excavation, PCC, reinforcement, formwork and backfilling, complete as required.
Excluding external HT cables and separately measured earth electrodes and external earthing
Supplying, installing, testing and commissioning an outdoor HT utility metering cubicle for an 11 kV
system, 12 kV class, manufactured to MSEDCL’s revised specification for prospective HT
consumers, incorporating the prescribed provision for a Power Quality Meter alongside the billing-
meter arrangement. Complete with MSEDCL-approved dry-type resin-cast metering CTs and
VTs/PTs, sealable compartments, approved terminal/test blocks, secondary wiring, tamper-resistant
wiring arrangement, revenue-meter mounting and viewing facilities, weatherproof enclosure,
supporting base, hardware and internal earthing. CT/PT ratios, accuracy classes, burdens, insulation
and fault-withstand ratings shall be as approved by MSEDCL. Including supply and installation of the
approved revenue energy meter under the sanctioned consumer-procurement arrangement, testing
and coordination for utility inspection, sealing and commissioning. Excluding the PQM instrument and
its communication equipment, external HT cables, cable terminations, civil plinth and external earthing
system, measured separately.
Digitally signed by RAKESH
Supplying, installing, testing and commissioning an outdoor HT vacuum circuit-breaker incomer
assembly with breaker/control cabinet for an 11 kV system, 12 kV class, 800 A, having 25 kA
short-circuit breaking capacity and 25 kA for 3 seconds short-time withstand, with corresponding peak-
making duty, subject to approved fault calculations. Complete with suitable busbars/connections, dry-
type resin-cast protection CTs, numerical overcurrent and earth-fault relay, trip/closing coils,
compatible DC battery and charger, operating mechanism, auxiliary contacts, indications, controls,
anti-condensation heater, approved terminal/cable connection arrangement, internal earthing, safety
interlocks, internal wiring and applicable transformer-protection interfaces. Including supporting
structure/base, anchor bolts and RCC foundation/plinth, excavation, PCC, reinforcement, formwork,
backfilling and grouting; applicable type-test documentation, routine tests, relay injection tests and
commissioning, complete as per approved drawings and applicable MSEDCL requirements. Excluding
external HT cables, separately measured cable terminations and external earthing system.
Supplying and delivering at site 3-core × 300 sq.mm aluminium conductor, XLPE insulated,
galvanised round steel wire armoured HT power cable of 6.35/11 kV (E) grade, comprising
stranded compacted aluminium conductors conforming to IS 8130; extruded semiconducting
conductor screens, XLPE insulation and extruded semiconducting insulation screens manufactured by
simultaneous triple extrusion; metallic copper-tape screening over each core; screened cores laid up
with suitable fillers and binder tapes; extruded heat-resistant PVC inner sheath of Type ST2
conforming to IS 5831; galvanised round steel wire armouring conforming to IS 3975; and extruded
27 Non-DSR black PVC outer sheath of Type ST2 conforming to IS 5831. Cable shall be ISI marked, conforming to Meter 70 2006 1,40,420
IS 7098 (Part 2), with applicable current revisions and amendments, and the MSEDCL technical
specification applicable to the approved project. Supply shall include manufacturer’s guaranteed
technical particulars, routine test certificates for each delivery length, applicable type-test reports and
acceptance-test documentation, identification and sequential metre markings, suitable drums with
sealed cable ends, packing, transportation, unloading and delivery at MGIRI Campus, Wardha,
complete as required. Excluding cable laying, jointing and end terminations, which shall be measured
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of
28 22.1.2 following size direct in ground including excavation, sand cushioning, protective covering and refilling Meter 70 694 48,580
the trench etc as required. Above 120 sq. mm and upto 400 sq. mm.
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other
29 23.1.4 jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as Each 4 4206 16,824
required: 300 sq. mm.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all
30 23.5.4 accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 Each 2 24255 48,510
KV grade as required: 300 sq. mm.
Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry
31 5.2 enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and Set 6 7658 45,948
salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode,
32 5.9 including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. Jointing by Meter 50 160 8,000
overlapping with two sets of G.I. nut bolts and spring washers spaced at 50 mm.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including
connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
34 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Meter 30 287 8,610
Total for Transformer & Associated Items 38,19,364.04
LT Panel & Asscociated items
Supplying, fabricating, installing and testing outdoor, weatherproof, floor-mounted, compartmentalised
sheet-steel LT panel enclosure, complete with structural framework, supporting plinth, gasketed
lockable doors, internal barriers and shrouds, equipment mounting arrangements, segregated cable
compartments, removable bottom-entry gland plates, protective bonding, lifting provisions, danger
notices, labels and necessary hardware. Enclosure shall have minimum IP55 protection, sloping rain
canopy with drip edges, corrosion-resistant surface treatment and exterior-grade powder-coated finish
in approved shade. Include protected ventilation and anti-condensation arrangements maintaining the
specified ingress protection, mechanical assembly and applicable IS/IEC 61439 verification, drawings
and test records, complete as per approved specifications. Electrical components, busbars and
associated wiring shall be covered under their respective BOQ items.
Supplying, installing, testing and commissioning 1600 A, 4-pole, motorised draw-out ACB for
transformer incomer, suitable for 415 V supply, complete with cradle, adjustable electronic LSIG
protection, spring-charging motor, closing and shunt-trip releases, auxiliary contacts, terminal shrouds,
mounting hardware and electrical connections; compatible with the specified AMF/changeover
interlocking. Protection settings shall coordinate with the transformer and incoming cable capacity.
Breaking capacity shall suit the approved fault level.
Supplying, installing, testing and commissioning 800 A, 4-pole, motorised draw-out ACB for DG
incomer, suitable for 415 V supply, complete with cradle, adjustable electronic LSIG protection, spring-
charging motor, closing and shunt-trip releases, auxiliary contacts, terminal shrouds, mounting
hardware and electrical connections; compatible with the specified AMF/changeover interlocking.
Protection settings shall coordinate with the DG and incoming cable capacity. Breaking capacity shall
suit the approved fault level.
Supplying, installing, connecting and testing 1600 A rated copper main busbar assembly for a 415 V,
three-phase, four-wire LT panel, comprising phase busbars, full-size neutral busbar and suitably sized
protective earth busbar, complete with insulated supports, spacers, phase identification, shrouds,
barriers, expansion arrangements where required, joint plates, suitable bolts and washers, and
connections to separately measured incomer and outgoing breakers. Busbar dimensions, support
38 Non-DSR spacing and joints shall be selected for the rated current, permissible temperature rise and short- Set 1 225000 2,25,000
circuit stresses of the complete assembly. Rated short-time withstand current shall provisionally be 50
kA for 1 second, with corresponding peak withstand capacity, subject to the approved fault-level
calculation and assembly verification. Complete as per approved drawings and applicable IS/IEC
61439 requirements.- For Khadi / Textile / Chemical / Bioprocessing feeder. Protection settings
shall coordinate with the downstream cable capacity and connected equipment.
Digitally signed by RAKESH
Supplying, installing, connecting, testing and commissioning 800 A rated, four-pole moulded-case
circuit breaker, suitable for 415 V, three-phase, four-wire operation, with adjustable electronic overload
and short-circuit protection, including instantaneous protection and earth-fault protection where
specified in the approved protection scheme. The breaker shall comply with applicable IS/IEC 60947-2
requirements, with breaking capacity selected from the calculated fault level at its installation point.
39 Non-DSR Work includes operating handle, mounting arrangement, terminal spreaders where required, terminal Each 1 150000 1,50,000
shrouds, phase barriers, suitable busbar links, cable connection provisions, hardware, feeder
identification, setting and functional testing, complete. - For the 63 kW Auditorium feeder. Protection
settings shall coordinate with the downstream cable capacity and connected equipment.- For Khadi
Textile & Chemical Bioprocessing feeder. Protection settings shall coordinate with the downstream
cable capacity and connected equipment.
Supplying, installing, connecting, testing and commissioning 160 A rated, four-pole moulded-case
circuit breaker, suitable for 415 V, three-phase, four-wire operation, with adjustable overload
protection and short-circuit protection, complying with applicable IS/IEC 60947-2 requirements.
Breaking capacity shall be selected from the calculated fault level at its installation point. Work
includes operating handle, mounting arrangement, terminal spreaders where required, terminal
shrouds, phase barriers, suitable busbar links, cable connection provisions, hardware, feeder
identification, setting and functional testing, complete. - For Auditorium feeder. Protection settings
shall coordinate with the downstream cable capacity and connected equipment.
Supplying, installing, connecting, testing and commissioning 500 A rated, four-pole moulded-case
circuit breaker, suitable for 415 V, three-phase, four-wire operation, with adjustable electronic overload
and short-circuit protection, including instantaneous protection and earth-fault protection where
specified in the approved protection scheme. The breaker shall comply with applicable IS/IEC 60947-2
41 Non-DSR requirements, with breaking capacity selected from the calculated fault level at its installation point. Each 1 90000 90,000
Work includes operating handle, mounting arrangement, terminal spreaders where required, terminal
shrouds, phase barriers, suitable busbar links, cable connection provisions, hardware, feeder
identification, setting and functional testing, complete. For Rural Craft/Engineering/Energy feeder.
Protection settings shall coordinate with the downstream cable capacity and connected equipment.
Supplying, installing, wiring, testing and commissioning AMF/automatic source-changeover control
system for the separately measured transformer and DG incomer ACBs, including controller, source-
voltage and frequency sensing, phase-failure and phase-sequence monitoring, adjustable mains-
failure, DG-start, warm-up, transfer, retransfer and cooldown timers; automatic/manual selection;
status indications; control relays, auxiliary contacts, protected control supply, terminal blocks and
42 Non-DSR internal control wiring. Work includes compatible mechanical and electrical interlocking, breaker- Set 1 85000 85,000
position feedback and break-before-make operation to prevent simultaneous closure of the two
incomers; DG remote start/stop and available/healthy interfaces; and load-management controls to
restrict DG loading to its permissible capacity. Complete with approved operating sequence, settings
and simulated failure/restoration tests. Any outgoing breaker actuators required for automatic load
shedding shall be expressly included in the approved equipment schedule and priced separately.
Supplying, installing, connecting, testing and commissioning two digital multifunction meters, one for
each incomer, suitable for three-phase, four-wire measurement, displaying phase and line voltages,
phase currents, frequency, power factor, active/reactive/apparent power and energy. Work includes
one set of three suitably rated metering CTs for each incomer, with ratios, accuracy class and burden
selected for the respective circuit; CT shorting/test terminal blocks; protected voltage-sensing
connections; source-available, breaker ON/OFF and trip indications; necessary control fuses/MCBs,
terminals, ferrules, labels and internal wiring. Complete with CT polarity, meter configuration and
functional checks. Two meters and two CT sets constitute one complete BOQ set.
Transformer incomer upto LTcable: Supplying and delivering at site 3.5-core × 400 sq.mm
aluminium conductor, XLPE insulated, armoured power cable of 1.1 kV grade, comprising three full-
size phase conductors and reduced-size neutral conductor, stranded compacted aluminium
conductors, XLPE insulation, suitable fillers, PVC inner sheath, galvanised steel strip armouring and
PVC outer sheath, conforming to IS 7098 (Part 1) with applicable amendments. Supply shall include
cable drums, identification and length markings, manufacturer’s routine test certificates, packing,
transportation and unloading at MGIRI Campus, Wardha, complete as required. Provision: four
parallel runs from transformer to Main LT Panel.
DG incomer upto LT cable: Supplying and delivering at site 3.5-core × 400 sq.mm aluminium
conductor, XLPE insulated, armoured power cable of 1.1 kV grade, comprising three full-size phase
conductors and reduced-size neutral conductor, stranded compacted aluminium conductors, XLPE
insulation, suitable fillers, PVC inner sheath, galvanised steel strip armouring and PVC outer sheath,
conforming to IS 7098 (Part 1) with applicable amendments. Supply shall include cable drums,
identification and length markings, manufacturer’s routine test certificates, packing, transportation and
unloading at MGIRI Campus, Wardha, complete as required. Provision: three parallel runs from DG
set to Main LT Panel.
Khadi Textile building outgoing cable: Supplying and delivering at site 4-core × 300 sq.mm
aluminium conductor, XLPE insulated, armoured power cable of 1.1 kV grade, comprising three phase
conductors and one full-size neutral conductor, stranded compacted aluminium conductors, XLPE
insulation, suitable fillers, PVC inner sheath, galvanised steel strip armouring and PVC outer sheath,
conforming to IS 7098 (Part 1) with applicable amendments. Supply shall include cable drums,
identification and length markings, manufacturer’s routine test certificates, packing, transportation and
unloading at MGIRI Campus, Wardha, complete as required. Provision: three parallel runs from Main
LT Panel to Khadi / Textile / Chemical / Bioprocessing building panel.
Auditorium Building outgoing cable: Supplying and delivering at site 4-core × 95 sq.mm aluminium
conductor, XLPE insulated, armoured power cable of 1.1 kV grade, comprising three phase
conductors and one full-size neutral conductor, stranded compacted aluminium conductors, XLPE
insulation, suitable fillers, PVC inner sheath, galvanised steel strip armouring and PVC outer sheath,
conforming to IS 7098 (Part 1) with applicable amendments. Supply shall include cable drums,
identification and length markings, manufacturer’s routine test certificates, packing, transportation and
unloading at MGIRI Campus, Wardha, complete as required. Provision: one run from Main LT Panel
to Auditorium building panel.
Rural Craft building outgoing cable: Supplying and delivering at site 4-core × 240 sq.mm aluminium
conductor, XLPE insulated, armoured power cable of 1.1 kV grade, comprising three phase
conductors and one full-size neutral conductor, stranded compacted aluminium conductors, XLPE
insulation, suitable fillers, PVC inner sheath, galvanised steel strip armouring and PVC outer sheath,
conforming to IS 7098 (Part 1) with applicable amendments. Supply shall include cable drums,
identification and length markings, manufacturer’s routine test certificates, packing, transportation and
unloading at MGIRI Campus, Wardha, complete as required. Provision: two parallel runs from Main LT
Panel to Rural Craft/Engineering/Energy building panel.
Laying the first cable in each trench, above 185 and up to 400 sq.mm, directly in ground, including
excavation, sand cushioning, protective covering and refilling.
Digitally signed by RAKESH
Laying additional cables, above 185 and up to 400 sq.mm, in the same trench in one-tier horizontal
formation, including specified trench works.
Laying one cable, above 35 and up to 95 sq.mm, directly in ground, including excavation, sand
cushioning, protective covering and refilling.
Supplying and making end termination with brass compression gland and aluminium lugs for following
52 11.1.31 size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as Each 14 1713 23,982
Supplying and making end termination of 4-core × 300 sq.mm aluminium conductor, XLPE insulated,
armoured power cable of 1.1 kV grade, including suitably sized brass compression gland matching the
actual cable diameter, gland locknut, earth tag, suitable aluminium compression lugs for all four
53 Non-DSR conductors, insulation sleeves, heat-shrink shrouds, phase and neutral identification, cable tags, nuts, Each 4 5000 20,000
bolts, washers and accessories. Work shall include cable-end preparation, armour earthing, lug
crimping using suitable dies, connection to equipment terminals, tightening and checking, complete as
Supplying and making end termination of 4-core × 95 sq.mm aluminium conductor, XLPE insulated,
armoured power cable of 1.1 kV grade, including suitably sized brass compression gland matching the
actual cable diameter, gland locknut, earth tag, suitable aluminium compression lugs for all four
54 Non-DSR conductors, insulation sleeves, heat-shrink shrouds, phase and neutral identification, cable tags, nuts, Each 2 2500 5,000
bolts, washers and accessories. Work shall include cable-end preparation, armour earthing, lug
crimping using suitable dies, connection to equipment terminals, tightening and checking, complete as
Supplying and making end termination of 4-core × 240 sq.mm aluminium conductor, XLPE insulated,
armoured power cable of 1.1 kV grade, including suitably sized brass compression gland matching the
actual cable diameter, gland locknut, earth tag, suitable aluminium compression lugs for all four
55 Non-DSR conductors, insulation sleeves, heat-shrink shrouds, phase and neutral identification, cable tags, nuts, Each 2 4000 8,000
bolts, washers and accessories. Work shall include cable-end preparation, armour earthing, lug
crimping using suitable dies, connection to equipment terminals, tightening and checking, complete as
Supplying, fixing, connecting and testing 50 × 6 mm galvanised iron protective earth strip along the
transformer-to-Main LT Panel route, including supports, clamps, jointing, bolts, nuts, washers,
equipment connections and corrosion protection at joints, complete as required. Strip size shall be
verified against the approved earthing calculation.
Total for LT Panel & Asscociated items 64,20,582.00
SUBSTATION BUILDING - 35 Sqm
A Earthwork, foundation and floor base
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers
58 2.25 not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to cum 11 196 2,156.00
50 and for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and
dressing complete. 100 mm thick below internal floor.
Providing and laying in position cement concrete of specified grade excluding the cost of centering
60 4.1.8 and shuttering—All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from cum 2.14 6812 14,577.68
natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering
61 4.1.8 and shuttering—All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from cum 2.969 6812 20,224.83
natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge; All works upto plinth level—Concrete of M25 grade with minimum
cement content of 330 kg/cum.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge; All works upto plinth level—Concrete of M25 grade with minimum
cement content of 330 kg/cum.
Centering and shuttering including strutting, propping etc. and removal of form for foundations,
footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for lintels, beams,
plinth beams, girders, bressumers and cantilevers.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse
67 4.1 sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived sqm 4.618 411 1,897.31
from natural sources).
B Block superstructure and lintel
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
68 6.4.1 superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cum 16.884 9,344.35 1,57,770.01
cement : 4 coarse sand).
Digitally signed by RAKESH
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°, landings,
balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above
69 5.3 plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement cum 0.156 11506 1,794.86
with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for lintels, beams,
plinth beams, girders, bressumers and cantilevers.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
C Floor and openings
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded
stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of
cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the
cost of nosing of steps etc. complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked
together through their entire length and jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with
73 10.6.1 push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long sqm 9 3653 32,878.80
wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454-
Part 1 and M.S. top cover of required thickness for rolling shutters. 80 × 1.25 mm M.S. laths with 1.25
mm thick top cover.
74 10.7 Providing and fixing ball bearing for rolling shutters. each 2 492 984.70
75 13.4.1 12 mm cement plaster of mix: 1:4 (1 cement : 4 coarse sand). E sqm 77.4 357 27,658.89
76 13.1.1 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand). sqm 72.846 347 25,281.20
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50
gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even
shade and colour: New work (two or more coats) over and including water thinnable priming coat with
cement primer having VOC content less than 50 gram/litre. Internal walls and reveals.
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat
78 13.46.1 applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm 77.4 161 12,430.44
sqm). External block walls.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two
79 13.61.1 or more coats on new work. Structural steel; steel primer included under item 10.2. Paint area sqm 65 156 10,133.50
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two
or more coats on new work. Rolling shutter, both faces.
E Steel frame, insulated roofing, cladding and drainage
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including
cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing 50 mm thick PUF insulated galvalume roofing panels, including fixings, EPDM
washers, sealants and necessary flashings complete; supporting steel measured separately.
Providing and fixing 50 mm thick PUF insulated galvalume upper-wall cladding panels, including
fixings, seals and necessary trims complete; supporting steel measured separately.
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness
0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc
85 12.51.2 coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5–7 microns epoxy primer on both metre 7 486 3,399.20
side of the sheet and polyester top coat 15–18 microns using self drilling/self tapping screws
complete: Flashings/Aprons (Upto 600 mm). High-edge flashing for apparent single-slope roof
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness
0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc
86 12.51.4 coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5–7 microns epoxy primer on both metre 10 452 4,515.00
side of the sheet and polyester top coat 15–18 microns using self drilling/self tapping screws
complete: Barge board (Upto 300 mm).
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness
0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc
87 12.51.6 coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5–7 microns epoxy primer on both metre 7 1314 9,195.90
side of the sheet and polyester top coat 15–18 microns using self drilling/self tapping screws
complete: Gutter (600 mm over all girth).
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592
88 12.41.2 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal metre 10 377 3,774.00
expansion, (i) Single socketed pipes. 110 mm diameter.
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised
89 12.42.5.2 Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring each 2 150 300.70
conforming to IS: 5382, leaving 10 mm gap for thermal expansion. Bend 87.5°—110 mm bend.
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised
90 12.42.6.2 Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring each 2 132 263.70
conforming to IS: 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain)—110 mm Shoe.
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water
pipes by means of 50 × 50 × 50 mm hard wood plugs, screwed with M.S. screws of required length,
including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making
good the wall etc. complete. 110 mm.
Digitally signed by RAKESH
F Entrance ramp—3.00 × 4.50 m, slope 1:10
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers
92 2.25 not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to cum 3.038 196 595.45
50 and for all lift.
Providing and laying in position cement concrete of specified grade excluding the cost of centering
93 4.1.8 and shuttering—All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from cum 1.357 6812 9,243.88
natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge; All works upto plinth level—Concrete of M25 grade with minimum
cement content of 330 kg/cum.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat
cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc.
complete, on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand). Ordinary cement
without any pigment.
Substation Building Total ₹ 9,98,042.38
Open-Air Transformer Pedestal (5 m × 5 m =25 sqm)
A Ground preparation and transformer foundation
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm
deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and
dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering
98 4.1.8 and shuttering—All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from cum 2.5 6812 17030
natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth
level—Concrete of M25 grade with minimum cement content of 330 kg/cum.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth
level—Concrete of M25 grade with minimum cement content of 330 kg/cum.
Centering and shuttering including strutting, propping etc. and removal of form for foundations,
footings, bases of columns, etc. for mass concrete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a
103 11.3.1 floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. sqm 19 614 11669.8
complete. 40 mm thick with 20 mm nominal size stone aggregate.
B Perimeter enclosure
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering
105 4.1.10 and shuttering—All work up to plinth level: 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from cum 1.22 6519 7952.692
natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources).
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50 × 50 mm including
107 16.70.1 strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction sqm 40 1018 40712
of Engineer-in-charge. Made of G.I. wire of dia 4 mm.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including
cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Total for Open-Air Transformer Pedestal ₹ 2,68,829.41
Solar Photovoltaic
Digitally signed by RAKESH
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant
conforming to various applicable standards BIS, IEC, MNRE
guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to
date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary
control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units,
Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting
arrangement, conduits, pipes, cable trays and other accessories etc. as required.
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in
India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar
Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature
coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must
be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10
109 17.1 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity kWp 16.00 54280 8,68,480.00
upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar
power project must have Radio
frequency identification tag with information such as name of manufacturer, month and year of
manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No
and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4
wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal
voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable
for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor,
Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller
Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-
up, synchronization & shutdown.
The PCU shall be able to withstand unbalanced load conforming to IEC standard with
shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole
isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage,
Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to
external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections
as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current,
AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output
power, Daily DC energy
produced and other parameters applicable standard. Communication interface RS 485 / RS 232. c)
Module mounting structure: The roof top solar plant generation units shall be installed by using
supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having
minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting
structure would be designed to sustain wind load and seismic parameter
of the site of installation. All the structure shall be design as per applicable BIS code and the material
shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and
electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts.
The suitable arrangements for maintenance and cleaning shall be provided. d) Real time online web
interfaced Data Monitoring System complete with accessories for various parameters such as Solar
Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input
Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as
per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for
incoming and outgoing cable along with glands, lugs and other
Total for Solar Photovoltaic 8,68,480.00
Sewage Treatment Plant
Providing a complete 5 KLD below-ground sewage treatment plant at MGIRI Campus, Wardha,
including specialist process and structural design, supply, civil construction, installation, testing and
commissioning, based on MBBR technology and the influent characteristics and treated-water quality
stipulated in the Technical Specifications. Civil works shall include setting out; excavation in the
specified ground conditions; temporary supports and dewatering; disposal of surplus excavated
material within the specified lead; PCC bedding; minimum M30-grade RCC collection/equalisation,
biological-treatment, clarification, sludge-holding and treated-water storage compartments as required
by the approved process design; reinforcement; formwork; construction-joint waterstops; watertight
sleeves and puddle flanges; sewage-resistant internal protective treatment; waterproofing; backfilling
and compaction; RCC roof/access slabs; sealed access covers and frames; corrosion-resistant
access ladders; ventilation pipes and cowls; equipment foundations; maintenance platform and
surface drainage. Structures shall be designed for earth pressure, groundwater uplift, empty-tank
condition and the surface loading specified in the tender. Mechanical and process works shall include
inlet screening; sewage transfer pumps; MBBR media and retention screens; duty/standby air
blowers; air-distribution piping and diffusers; clarification and sludge withdrawal/return arrangements;
pressure sand and activated-carbon filters; disinfection equipment; treated-water pumps; sludge-
handling arrangements; all process piping, valves, fittings, supports and instruments. Provide
duty/standby sewage-transfer and filter-feed pumps, automatic level controls and equipment-removal
arrangements. Electrical works shall include a dedicated outdoor weatherproof control panel, feeder
and motor protection, starters, automatic/manual controls, operating indications, alarms, internal
power and control wiring, equipment earthing and protective bonding; external protective feeder, up to
40 m of appropriately sized 1.1 kV armoured power cable with laying and terminations; and up to 20 m
each of inlet and treated-water outlet piping with fittings, connections and reinstatement. Provide
weather-protected, ventilated and accessible above-ground installation arrangements for blowers,
filtration, dosing equipment and electrical controls. Include initial media and chemicals, transportation,
unloading, coordinated drawings and calculations, water-tightness testing, commissioning, specified
trial operation, laboratory performance testing, operator training, as-built drawings, O&M manuals and
warranties, complete in accordance with approved drawings and Technical Specifications.
Total for STP 11,21,000.00
Effluent Treatment Plant
Digitally signed by RAKESH
Providing a complete 4 KLD below-ground effluent treatment plant at MGIRI Campus, Wardha,
including influent sampling and characterisation, specialist process and structural design, supply, civil
construction, installation, testing and commissioning, for the wastewater streams, pollutant loading and
treated-effluent quality stipulated in the Technical Specifications. Civil works shall include setting out;
excavation in the specified ground conditions; temporary supports and dewatering; disposal of surplus
excavated material within the specified lead; PCC bedding; minimum M30-grade RCC
collection/equalisation, neutralisation, reaction/flocculation, clarification, sludge-holding and treated-
effluent storage compartments, together with biological-treatment compartments where required by
the specified treatment duty; reinforcement; formwork; construction-joint waterstops; watertight
sleeves and puddle flanges; chemically compatible protective lining and waterproofing; backfilling and
compaction; RCC roof/access slabs; sealed access covers and frames; corrosion-resistant access
ladders; ventilation pipes and cowls; equipment foundations; maintenance platform; surface drainage
and bunded chemical-storage/dosing arrangements. Structures shall be designed for earth pressure,
groundwater uplift, empty-tank condition and the surface loading specified in the tender. Mechanical
and process works shall include screening; oil-and-grease separation where required by the specified
influent; transfer pumps; equalisation mixing/aeration; pH measurement and automatic correction;
chemical-storage tanks and dosing pumps; coagulation, flocculation and clarification equipment;
biological treatment where required by the specified treatment duty; pressure sand and activated-
carbon filtration; specified disinfection; treated-effluent pumps; sludge withdrawal and suitably sized
sludge-dewatering equipment; all process piping, valves, fittings, supports and instruments. Provide
duty/standby transfer and filter-feed pumps and materials compatible with the identified effluent and
treatment chemicals. Electrical works shall include a dedicated outdoor weatherproof control panel,
feeder and motor protection, starters, automatic/manual controls, level controls, operating indications,
alarms, internal power and control wiring, equipment earthing and protective bonding; external
protective feeder, up to 40 m of appropriately sized 1.1 kV armoured power cable with laying and
terminations; and up to 20 m each of inlet and treated-effluent outlet piping with fittings, connections
and reinstatement. Provide weather-protected, ventilated and accessible above-ground arrangements
for machinery, filters, dosing equipment and electrical controls. Include initial filter media and
commissioning chemicals, transportation, unloading, coordinated drawings and calculations, water-
tightness testing, commissioning, specified trial operation, laboratory performance testing, chemical-
consumption records, sludge-handling instructions, operator training, as-built drawings, O&M manuals
and warranties, complete in accordance with approved drawings and Technical Specifications.
Total for ETP 1,35,700.00
For Auditorium Building LED Screen
Supplying, installation, testing and commissioning of indoor LED display screen of size 6.0 m × 3.0 m
(±5%), modular panel type, having pixel pitch P2.5 or better, suitable for auditorium application,
High-resolution LED panels (die-cast aluminium cabinets)
Supporting MS frame structure with powder coating
SMPS power supply units & receiving cards
112 Non-DSR Video processor/controller (HDMI/DVI compatible) Each 1.00 1450000 14,50,000.00
Data & power cabling with routing accessories
Wall mounting / structural support system
Electrical integration with existing system
All accessories, hardware, and fixtures
Testing, commissioning, and demonstration
Complete in all respects as per specifications and directions of Engineer-in-Charge.
Total For Auditorium Building LED Screen 14,50,000.00
AUDITORIUM WALL (Upper Area): Providing and fixing Silence Acoustic 9mm acoustic panel (Size:
2420×1220×9 mm, Weight: 5 Kg/panel, 1850 gsm, NRC up to 0.9) in approved colour and shade as
per Architect’s approval, fixed on perforated plywood strips. GI frame fabricated with 80×26×0.4 mm
ceiling sections, 20×27×30×0.4 mm perimeter channel, 15×45×0.5 mm intermediate channel,
113 Non-DSR 25×10×0.4 mm ceiling angle @600 mm c/c. Panels backed with SYNTH acoustic insulation (Density: SQFT 2730 543 14,81,844
20 Kg/m³, Thickness: 50 mm, NRC up to 0.9, GSM: 1000, Size: 1.2×15 m). Including all fixing
accessories, proper alignment, finishing and workmanship complete as per approved drawings. Note:
Provision for profile lights, cove lights, framing, plywood support for CCTV, speakers, lights to be
AUDITORIUM WALL (Lower Area – up to 8 ft): Providing and fixing 8 ft from ground level acoustic
panelling made from prelaminated grooved MDF Silence Acoustic 12mm panel (Size: 2420×1220×12
mm, Weight: 5 Kg/panel, Density: 200 Kg/m³, NRC up to 0.85) as per acoustic design and Architect’s
approval. Grooved panel laminated in approved shade, mounted on GI frame fabricated with
80×26×0.4 mm sections, 20×27×30×0.4 mm perimeter channel, 15×45×0.5 mm intermediate channel,
25×10×0.4 mm ceiling angle @600 mm c/c, fixed to wall over SYNTH acoustic insulation (Density: 20
Kg/m³, Thickness: 50 mm, NRC up to 0.9, GSM: 1000, Size: 1.2×15 m). Including GI mesh support
(1.0 kg/m²), thermal conductivity 0.04 W/mK, low VOC, RC % 25, all cut-outs, fixing, finishing
complete. Note: Provision for profile lights, cove lights, framing, plywood support for CCTV, speakers,
lights to be provided.
SEATING AREA CEILING
AUDITORIUM CEILING: Providing and fixing 24mm grid false ceiling (Grid Type: T24 exposed tee
115 Non-DSR system, face width 24 mm, module size 600×600 mm, finish powder-coated/pre-painted). Edge detail: SQFT 3098 188 5,81,322
Lay-in (square edge) with 9mm Silence acoustic panel, complete.
ENTRANCE LOBBY, PASSAGE & CONFERENCE ROOM
AUDITORIUM CEILING: Providing and fixing 24mm grid false ceiling (Grid Type: T24 exposed tee
116 Non-DSR system, face width 24 mm, module size 600×600 mm, finish powder-coated/pre-painted). Edge detail: SQFT 2000 188 3,75,240
Lay-in (square edge) with 9mm Silence acoustic panel, complete.
STAGE WALL: Providing and fixing Silence Acoustic 9mm Acoustic panel (Size: 2420 × 1220 × 9 mm,
Weight: 5 Kg/Panel, 1850 gsm, NRC: up to 0.9) in approved colour and shade as per
Client/Architect’s approval, fixed on perforated plywood strips. G.I frame fabricated with 80×26×0.4
ceiling sections, 20×27×30×0.4 perimeter channel as required, 15×45×0.5 intermediate channel,
117 Non-DSR 25×10×0.4 ceiling angle at 600mm c/c. The panels shall be backed with SYNTH acoustic insulation SQFT 1045 543 5,67,226
having (Density: 20 Kg/m³, Thickness: 50 mm, NRC: up to 0.9, GSM: 1000, Size: 1.2 × 15 mtr)
complete with all fixing accessories, proper alignment, finishing and workmanship, as per approved
drawings. Note: Provision of profile lights, cove lights, framing, plywood support for CCTV, speaker,
lights has to be provided.
STAGE CEILING: Providing and Fixing 24mm grid false ceiling (Grid Type: T24 exposed tee system,
118 Non-DSR Face Width: 24 mm, Module Size: 600 × 600 mm, Finish: Powder-coated / Pre-painted, Edge Detail: SQFT 581 177 1,02,802
Lay-in (Square edge)) with 9mm silence acoustic panel.
Digitally signed by RAKESH
STAGE PROSCENIUM AREA: Providing and fixing Proscenium Arch along left and right side of stage
as per drawing, finished in approved laminate shade. The proscenium cladding shall be fabricated
using 18mm thick pre-laminated MDF board (one-side balancing laminate on backside and exposed
side finished with matching/approved laminate), fixed over suitable MS / GI / wooden frame anchored
to wall paneling. All visible joints to be finished in line and level and screw heads to be concealed to
achieve seamless appearance. Work includes integrated pelmet detailing with provision for blackout
roller blinds including roller mechanism, brackets, operating chain, bottom rails and all necessary
fixtures and hardware for smooth operation. Colour/shade of blinds to be as approved.
STAGE FLOORING: Providing & fixing in position Stage flooring using 15 mm thick Teak wood planks
on 18 mm water proof ply, filling gaps and hand polish, as per Architectural & Acoustical Design &
Instructions & complete in all aspects. No extra amount paid for provision of profile lights, framing &
finish, other framing supporting speakers, lights, etc.
Total For Acoustic Works 48,04,040
STAGE LIGHTING WORKS
Supplying, installing, testing and commissioning of 100W Zoomable High Quality LED Parcan Light
complete with COB Lamp source 3200K CCT Colour temperature, CRI & TLCI values above 95, DMX
512 dimming with 3 Channel DMX Control, Beam Angle of 11 to 35 Degree, Power Consumption
120W, Black powder coated housing, suitable for stage lighting to illuminate key areas.
Supplying, installing, testing and commissioning of 200W LED Profile Light 19 degree 3200K colour
temperature with high quality parameters of CRI & TLCI 95+. Luminaire provided with gel holder, gobo
holding, 0% to 100% dimming, 3 Channel DMX Control, manual focus with 4 beam shaping cutters
with master/slave & manual adjustment, IP20 rating of protection.
Supplying, installing, testing and commissioning of 400W LED Blinder Light 30 degree complete with
3200K CCT, 4×100W Chip on Board LED lamp source, DMX 512 dimming with 4/8 channel modes,
black finish housing, IP20 protection, strobe option and smooth dimming, to illuminate stage with
uniform light intensity levels.
Supplying, installing, testing and commissioning of 54 × 3W LED Par Light RGBW, Beam Angle 25°,
complete with RGBW 3W lamp source (54 pcs), DMX512 dimming with 8 channel, powder coated
black finish housing, IP20 protection having sound control & master/slave auto run mode. Illuminate
indoor stage with unlimited colour effects.
Supplying, installing, testing and commissioning of 54×3W LED 3200K Par Light, Beam Angle 25°,
complete with 3200K 3W lamp source (54 pcs), CRI & TLCI above 95, flicker free for high FPS,
smooth fade in & fade out, high precision steady colour, no heat, DMX512 dimming with 2 channel
(0–100%), powder coated black finish housing, IP20.
Supplying, installing, testing and commissioning of Aluminium ‘O’ Type clamp made up of high grade
aluminium (thickness ≥5 mm), suitable for round tubes of 40–55 mm outer diameter, complete with
fixture mounting 25mm MS bolt & wing nut, minimum 100 kg safe working load, 40 mm bolt & wing nut
for pipe locking.
Supplying, installing, testing and commissioning of Light Fixture dual safety chain made of GI wire
rope bundled and twisted together having load bearing capacity above 200 kg, sleeve on rope.
Supplying, installing, testing and commissioning of Suspender cum clamps designed as per site
127 Non-DSR condition made out of MS material (50×50×6 mm) with black powder coated finish and threaded rod of Nos 14 2531 35,431.27
minimum 12 mm suitable to hold basic grid.
Supplying, installing, testing and commissioning of On Stage Fixed Lighting Bar (7 m length), straight
128 Non-DSR as per design, made of 40NB/48 OD MS pipe dual barrel construction connected with MS flat, duly Nos 2 25693 51,386.88
powder coated with matt black texture finish paint.
Supplying, installing, testing and commissioning of 8 Mtr FOH Fixed Lighting Bar straight as per the
129 Non-DSR design made out of 40NB 48 OD Mild steel pipe dual barrel, dual construction connected with MS flat Nos 1 29364 29,364.12
duly powder coated with matt black texture finish.
Supplying, installing, testing and commissioning of Digital Lighting Console with 1024 DMX channels,
1024 channels, 10 programmable executors, master fader, keypad entry, LCD display, encoder
wheels, LTP slope channels for each fixture 40 primary + 40 fine tune switchable page
scenes/playbacks, 10 scenes to run simultaneously, 600 scene step, shapes of dimmer, pan/tilt, RGB,
CMY, color, gobo, iris and focus, master slider, global playback, fixture USB memory, FAT32
Supplying, installing, testing and commissioning of Dimming system consist of opto isolated RDM
enabled DMX splitter unit, 8 output channels. Dimming in and out junction box 1 way with 5 pin DMX
131 Non-DSR XLR male-female socket, DMX male female connectors 5 pin having rubber sheath protection for Lot 1 100486 1,00,485.85
cross connecting DMX wiring connections & male termination connector 5 pin. 5 core DMX cable with
sheathed housing on the cable, low noise suitable to transmit DMX signal.
Supplying, installing, testing and commissioning the remaining stage-lighting power distribution
assembly comprising panel enclosure, 63 A copper busbars, separate neutral and earth bars,
minimum 40 A four-pole contactor suitable for LED-driver inrush, emergency-stop and manual-reset
132 Non-DSR controls, RYB indicators, 10 A IEC power junction boxes, internal copper earthing, 150 mm and 75 Lot 1 2,42,980.01 2,42,980.01
mm powder-coated perforated MS cable trays with lids, and 3-core × 1.5 sq.mm FRLS copper flexible
final-circuit cables, including connections, identification and testing, complete. Separately measured
isolator, MCBs, RCCBs and incoming feeder excluded.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable
2.10 for inductive load of following poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
2.14 circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable
2.10 for inductive load of following poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
136 2.10.5 Triple pole and neutral Each 1 1,301.00 15,720.00
Digitally signed by RAKESH
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core
cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess
1.20 including painting in case of surface conduit, or cutting the wall and making good the same in case of
recessed conduit as required.
Total For Stage Lighting Works 14,08,051
Supplying, installing, testing and commissioning of Motorized Main Curtain 9.5 Mtrs straight centre
parting as per design made up of 1 track of size 48mm × 75mm for complete length with overlap of
0.5–0.9 Mtrs, trolleys uniformly distributed along the track at every 200/250mm with a master trolley,
drive unit with suitable capacity motor unit, GI wire rope. All metal parts are powder coated.
Supplying, installing, testing and commissioning of On Stage Fixed Valance Bar 8.5 Mtrs length
133 Non-DSR straight as per design made out of 40NB 48 OD mild steel pipe dual barrel, supported to hang the Nos 1 20067 20,067
main valance of the stage system, duly powder coated with matt black texture finish paint.
Supplying, installing, testing and commissioning of On Stage Fixed Frill Bar 8 Mtrs length straight as
134 Non-DSR per the design made out of 40NB 48 OD mild steel pipe dual barrel, single construction connected Nos 1 16713 16,713
with MS flat, duly powder coated with matt black texture finish paint.
Supply of high quality velvet fabric fire retardant treated as per approved colour and make with
135 Non-DSR gathering of 100% stitched as per site condition, curtain provided with eyelets at every 200/250mm for Nos 1 179326 1,79,326
uniform fixing on to curtain trolleys (For Main Curtain size 9.5Mtr).
Supply of high quality velvet fabric fire retardant treated as per approved colour and make with
136 Non-DSR gathering of 100% stitched as per site condition, curtain provided with eyelets at every 200/250mm for Nos 1 29713 29,713
uniform fixing on to curtain trolleys (For Valance Curtain size 8.5Mtr).
Supply of high quality cotton fabric fire retardant treated as per approved colour and make with
137 Non-DSR gathering of 50% stitched as per site condition, curtain provided with eyelets at every 200/250mm for Nos 1 19150 19,150
uniform fixing on to curtain trolleys (For Frill size 8Mtr).
Supplying, installing, testing and commissioning of Cable Connecting Circuit Boxes for the termination
138 Non-DSR of cables from Electrical panel to the grid level point made out of MS sheet metal fabricated housing Nos 1 2394 2,394
duly powder coated with matt black texture finish paint, fitted with required channels and ivory
Supplying, installing, testing and commissioning of Motor Control Panel cum remote control 1 Way
139 Non-DSR providing power input for curtain motors internally neatly wired with contactors having individual motor Nos 1 47621 47,621
control with required push button, emergency trip, RYB indicators, supply indicator
Supplying, installing, testing and commissioning of C Profile MS hot rolled strips 3mm thick with extra
140 Non-DSR U bend used either to create basic supports for various auditorium stage rigs, duly powder coated with Mtrs 30 1091 32,731
matt black texture finish paint
Supplying, installing, testing and commissioning of Suspender cum clamps designed as per site
141 Non-DSR condition made out of MS material of size 50x50x6mm with black powder coated finish and threaded Nos 7 2531 17,716
rod of minimum 12mm suitable to hold heavy grid
Supplying, installing, testing and commissioning of FRLS Copper unarmoured flexible cable having 7
core each of 1.5 sq mm size
Supplying, installing, testing and commissioning of FRLS Copper unarmoured flexible cable having 4
core 4 sq mm size
Total For Stage Drapery Works 6,54,914
Acoustic Nylon Carpet Flooring with Acoustic Underlay for Auditorium Seating
Providing and laying commercial-grade acoustic tufted nylon wall-to-wall carpet complying with IS
17478:2020, 6–8 mm overall thickness, over 8–10 mm firm, compression-resistant acoustic underlay
suitable for auditorium seating areas and heavy pedestrian traffic. The complete carpet-and-underlay
assembly shall have sound-absorption test data to IS 8225:2018 / ISO 354:2003, meeting the
approved auditorium acoustic design, and minimum Bfl-s1 fire classification to EN 13501-1 for the
specified installation system. Including substrate preparation, manufacturer-approved low-VOC
adhesive, cutting, jointing, secured edge trimming, flush / bevelled aluminium transition strips,
accessories and complete laying in approved shade and pattern, with relevant test reports and
manufacturer’s installation instructions.
Total For Acoustic Nylon Carpet Flooring 9,48,600
Audio Visual Works
Supplying professional passive auditorium loudspeaker, with plywood cabinet, nominal impedance 8
ohms, stated frequency response 50 Hz–20 kHz, suitable input/output connectors, protective grille,
handles and durable black finish, complete. Make indicated: GS PRO. Driver configuration and
continuous power rating shall be confirmed from the approved model datasheet.
Supplying four-channel professional power amplifier, with stated per-channel outputs of 2,200 W at 2
ohms, 1,600 W at 4 ohms and 800 W at 8 ohms; signal-to-noise ratio 100 dB, THD below 0.5%,
146 Non-DSR frequency response 20 Hz–20 kHz, necessary input/output connectors and power connection, Each 2 110486 1,10,488
complete. Make indicated: GS PRO. Output ratings shall be confirmed for the specified operating
Supplying 1,000 W passive subwoofer, comprising 18-inch low-frequency driver with 3-inch voice coil,
plywood enclosure, stated 60° × 60° controlled coverage, two NL4 connectors, protective grille,
handles and durable black finish, suitable for integration with the auditorium sound system, complete.
Make indicated: GS PRO.
Supplying 12-inch active stage-monitor loudspeaker, with built-in bi-amplification, stated 450 W output,
148 Non-DSR DSP sound presets and equalisation, independently controllable microphone/line inputs with XLR/6.3 Each 2 40032 40,034
mm connections, protective enclosure and power accessories, complete. Make indicated: NX AUDIO.
Digitally signed by RAKESH
Supplying professional manual audio crossover, suitable for dividing the audio signal into the required
frequency bands and integrating the main loudspeakers and subwoofers, complete with necessary
operating controls and input/output connections. Make indicated: DBX. Model and operating
configuration shall be confirmed.
Supplying 12-channel audio mixing console, comprising six microphone inputs and twelve line inputs
through four mono and four stereo channels, two group buses, one stereo bus, two auxiliary buses
150 Non-DSR including effects, microphone preamplifiers, one-knob compressors, SPX digital effects, 24-bit/192 Each 1 29176 29,177
kHz two-input/two-output USB audio interface, +48 V phantom power, metal chassis and power
supply, complete. Make indicated: YAMAHA.
Supplying podium gooseneck microphone with base, comprising metal-bodied microphone, XLR
151 Non-DSR connection, approximately 20 mm microphone diameter, stated weight 960 g and necessary Each 1 23069 23,070
connection accessories, complete. Make/model indicated: CIRCLE PRO, CIRCLE PRO.
Supplying dual-channel wireless lapel microphone system, operating in the stated 500–865 MHz
range, with frequency modulation, selectable operating bandwidth, stated signal-to-noise ratio 105
152 Non-DSR dB(A), two compatible transmitters and lapel microphones, receiver, power supply and connection Set 1 20966 20,967
accessories, complete. Make indicated: CIRCLE PRO. Operating frequencies shall be selected within
the permitted Indian spectrum allocation.
Supplying dual handheld wireless microphone system, comprising two handheld microphones,
compatible receiver, selectable UHF channels, frequency display, independent channel output and
level controls, mixed output and power accessories, complete. Make indicated: CIRCLE PRO.
Operating frequencies shall be selected within the permitted Indian spectrum allocation.
Supplying floor-mounted 22U audio-equipment rack, suitable for standard 19-inch rack equipment,
154 Non-DSR complete with adjustable mounting arrangements, lockable front door, removable side panels, Each 1 30533 30,534
equipment mounting hardware and cable-management provisions. Make indicated: MASSRACK.
Supplying two-conductor shielded audio signal cable, with 24 AWG stranded tinned-copper
155 Non-DSR conductors, polyethylene insulation, foil-polyester shield, tinned-copper drain wire and outer protective m 100 96 196
jacket, suitable for balanced audio connections. Make indicated: BELDEN / approved equivalent.
Supplying two-core speaker cable, 2 × 1.5 sq.mm, with stranded copper conductors, dual PVC
156 Non-DSR insulation/sheathing and protective outer jacket, suitable for connections between power amplifiers m 400 129 529
and passive loudspeakers. Make indicated: BELDEN / RAMCRO.
Supplying and laying 25 mm diameter heavy-duty FRLS PVC conduit, including bends, couplers,
157 Non-DSR junction accessories, saddles, screws and ties, fixed on walls/ceilings along the approved audio-cable m 400 74 474
routes, complete. Make indicated: GGT.
Supplying audio connectors and connection accessories, suitable for the selected microphones,
mixer, amplifiers and loudspeakers, complete with necessary plugs, sockets and termination
158 Non-DSR Each 12 679 691
accessories. Make indicated: NEUTRIK. Connector types shall follow the approved connection
Packing, handling and transportation of the specified audio equipment, cables and accessories from
the supplier’s premises to the project site, including protective packing and delivery, complete.
Installation, testing, training and commissioning of the complete audio system, including equipment
positioning and mounting, cable pulling through conduits, cable terminations, rack assembly,
equipment interconnections, gain and crossover settings, functional testing, system demonstration
and operator training, complete.
Total for Audio Visual 5,21,986.68
GRAND TOTAL FOR ADDITIONAL ITEM WORKS 275,63,655.10
GRAND TOTAL FOR ADDITIONAL ITEM WORKS 275,63,655.10
Digitally signed by RAKESH
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
01NIT.pdf
Tender Document
03Technical_Specification.pdf
Tender Document
05Scope_of_Work_MGIRI.pdf
Tender Document
06SCC_MGIRI.pdf
Tender Document
07MGIRI_Drawings.pdf
Tender Document
08Index.pdf
Tender Document
GCC.pdf
Tender Document
Soil_Report.pdf
Tender Document
Approved_makes.pdf
Tender Document
Technical_circulers.pdf
Tender Document
02BOQ_MGIRI Infrastructure.pdf
Tender Document
addendum-867e52919117-Addendum.pdf
pdf • 0.88 MB
addendum-16f94816968e-Addendum01_MGIRI.pdf
pdf • 0.94 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .