Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAdmitted-Fee/PreQual/Technical/Finance | ₹27.5 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹29.1 L+₹1.6 L (5.71%)Admitted-Fee/PreQual/Technical/Finance | ₹29.1 L+₹1.6 L (5.71%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹33.6 L+₹6.1 L (22.0%)Admitted-Fee/PreQual/Technical/Finance | ₹33.6 L+₹6.1 L (22.0%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | SANJU JOY L2 | GICON BUILDERS L1 | SYAM SANKER L3 |
|---|---|---|---|---|---|---|
| 1.00App -A- Supplying and Fixing of Raw Water Pumpset | ||||||
| 1.00 | OD67987/2026-2027:Design, Supply , erection, testing, Trial run and commissioning of CF pump set with the following specification -
1. Pump - Supply, erection, testing and commissioning of KWA pre-qualified reputed make centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable types base plate with coupling, coupling guard, foundation bolts and nuts etc. complete including providing suitable concrete foundation including cost of material etc. complete. as per CEA regulation 2010 and present code of practice for operating head - 55 M having a discharge of 2.75 LPS including
1 as stand by including cost of all required protection equipment with an efficiency not less than 70%, Suction head ? positive suction,
2. Motor Supply, erection, testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz Ac supply, working voltage 415V/3300 V(select suitable), 1500rpm. The motor shall confirm to Latest IE standards, including providing suitable concrete foundation, including cost of
materials etc. complete for 3300 V motors digital motor protection. Relay shall be included in starter as per present IE rules. . Flexible coupling shall be used for coupling of pumps and motors
3. Starter. Supply erection testing and commissioning of suitable rating (Fully automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starter to be used) . Here soft starter to be provided. Starter suitable for the above motor with over voltage and under voltage protection, single phase preventor, overload relay with motor protection relay with main contactor and bye pass contactor as per IE rules and code of practice etc complete.
4. Panel board - Supply , erection, testing and commissioning of cubical type wall mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity motor protection MCCB as incomer and and
No of suitable capacity MCCB as outgoing providing suitable size Aluminium bus bar to interconnect the above MCCBs and fitted with 3 Nos of indicator lamps,1 no. volt meter with selector switch ,1 no. Ammeter with selector switch for measuring
current in each phase etc. complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation.
5. Cabling work - Supply, laying testing and commissioning of suitable size XLPE copper cables for the above pump set from panel board to starter and from starter to motor considering energy conservation for a total length of 10 M.
6. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe /plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.
7. Capacitor - Supply, erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. Capacitor should be connected to external contactor, and the capacitor shall confirm to IS 2834
8.Valves and Pressure gauges ? Supply, Erection and commissioning of suitable size best quality heavy duty ISI marked CI double flanged Sluice Valve electrical actuator (capable of operating in Fully, Semiautomatic modes and also in manual mode), Non Return Valve and Pressure Gauges with suitable Pressure rating. Fitting of valves shall include proper RCC support. In case of positive suction pipes set sluice valve should be in suction as well as delivery sides for easy repair works.
9. Suction and delivery pipe connection - Supply and fitting of suitable size best quality MS pipe of shell thickness not less than 10 mm for a total of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc complete and connecting the delivery side of thr pump with the valves and suitable specials to connect the pumping main. If the dia of suction pipe is above 80 mm CI pipes and specials shall be provided. Efficiency of pumpset shall not be less than 70%. The guarantee period is minimum 5 years with full replacement of above mentioned units . As per the order no. 9710/AE15/2021/KWA Dtd 8-2-2023. Even though the design is done in this office, the contractors is advised to re- design them got approved from competent authorities before it is executed. | 2 | no | 92,766 ₹1,85,532 | 70,000 ₹1,40,000 Lowest | 1,05,000 ₹2,10,000 |
| 1.00 | OD81602/2026-2027:Electrification charges for pump house including lights, meter board, DB and Earthing | 1 | no | 5,390 ₹5,390 Lowest | 50,000 ₹50,000 | 6,400 ₹6,400 |
| 2.00App -B- Providing RWPM and Distribution network. | ||||||
| 2.00 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | 240 | cum | 550 ₹1,32,000 | 350 ₹84,000 Lowest | 550 ₹1,32,000 |
| 2.00 | 100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock. | 30 | cum | 830 ₹24,900 | 350 ₹10,500 Lowest | 950 ₹28,500 |
| 2.00 | 100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited. | 30 | cum | 1,500 ₹45,000 | 350 ₹10,500 Lowest | 1,850 ₹55,500 |
| 2.00 | OD80294/2026-2027:Conveying and fixing G.I. pipes complete with G.I. fittings Excluding trenching, refilling , cost of pipes and fittings for External work: 65mm diameter nominal bore. (Derived from 100.12.7) | 2,000 | metre | 80 ₹1,60,000 Lowest | 240 ₹4,80,000 | 105 ₹2,10,000 |
| 2.00 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 36 | cum | 2,000 ₹72,000 | 1,500 ₹54,000 Lowest | 2,300 ₹82,800 |
| 2.01 | OD68059/2026-2027:Cutting, Grinding and Welding 65 mm (I.D.) G.I/ S.S/ M.S. pipes for making bends and other specials by gas cutting . Grinding the cut edges / welded portions in M.S. sheet, pipe and specials by grinding machine. Welding pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 3.60 mm to 8 mm thick M.S. plates. | 6,796.53 | cm | 12 ₹81,558.36 | 3 ₹20,389.59 Lowest | 18 ₹1,22,337.54 |
Tender Value
₹34.7 L
EMD Value
₹50,000
Closing Date
24 Aug 2026, 5:00 pmClosed
Executive Engineer
Kerala Water Authority PH Division Pathanmthitta
DEPOSIT Aruvappulam GP Kandathinkara Water Supply Scheme Ward 12 Phase 2 GL Tank Pump set Pumping lines and Distribution lines General Civil Work
2026_KWA_865897_1
09/2026-27/EE/PH/PTA
Open Tender
Civil Works - Water Works
Item Rate
180 days
Aruvapulam grama panchyath
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,257
₹50,000
29 Aug 2026
18 Aug 2026
29 Aug 2026
18 Aug 2026
24 Aug 2026
18 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1App -A- Supplying and Fixing of Raw Water Pumpset | |||||
| 1.001 | OD67987/2026-2027:Design, Supply , erection, testing, Trial run and commissioning of CF pump set with the following specification -
1. Pump - Supply, erection, testing and commissioning of KWA pre-qualified reputed make centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable types base plate with coupling, coupling guard, foundation bolts and nuts etc. complete including providing suitable concrete foundation including cost of material etc. complete. as per CEA regulation 2010 and present code of practice for operating head - 55 M having a discharge of 2.75 LPS including
1 as stand by including cost of all required protection equipment with an efficiency not less than 70%, Suction head ? positive suction,
2. Motor Supply, erection, testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz Ac supply, working voltage 415V/3300 V(select suitable), 1500rpm. The motor shall confirm to Latest IE standards, including providing suitable concrete foundation, including cost of
materials etc. complete for 3300 V motors digital motor protection. Relay shall be included in starter as per present IE rules. . Flexible coupling shall be used for coupling of pumps and motors
3. Starter. Supply erection testing and commissioning of suitable rating (Fully automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starter to be used) . Here soft starter to be provided. Starter suitable for the above motor with over voltage and under voltage protection, single phase preventor, overload relay with motor protection relay with main contactor and bye pass contactor as per IE rules and code of practice etc complete.
4. Panel board - Supply , erection, testing and commissioning of cubical type wall mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity motor protection MCCB as incomer and and
No of suitable capacity MCCB as outgoing providing suitable size Aluminium bus bar to interconnect the above MCCBs and fitted with 3 Nos of indicator lamps,1 no. volt meter with selector switch ,1 no. Ammeter with selector switch for measuring
current in each phase etc. complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation.
5. Cabling work - Supply, laying testing and commissioning of suitable size XLPE copper cables for the above pump set from panel board to starter and from starter to motor considering energy conservation for a total length of 10 M.
6. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe /plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.
7. Capacitor - Supply, erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. Capacitor should be connected to external contactor, and the capacitor shall confirm to IS 2834
8.Valves and Pressure gauges ? Supply, Erection and commissioning of suitable size best quality heavy duty ISI marked CI double flanged Sluice Valve electrical actuator (capable of operating in Fully, Semiautomatic modes and also in manual mode), Non Return Valve and Pressure Gauges with suitable Pressure rating. Fitting of valves shall include proper RCC support. In case of positive suction pipes set sluice valve should be in suction as well as delivery sides for easy repair works.
9. Suction and delivery pipe connection - Supply and fitting of suitable size best quality MS pipe of shell thickness not less than 10 mm for a total of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc complete and connecting the delivery side of thr pump with the valves and suitable specials to connect the pumping main. If the dia of suction pipe is above 80 mm CI pipes and specials shall be provided. Efficiency of pumpset shall not be less than 70%. The guarantee period is minimum 5 years with full replacement of above mentioned units . As per the order no. 9710/AE15/2021/KWA Dtd 8-2-2023. Even though the design is done in this office, the contractors is advised to re- design them got approved from competent authorities before it is executed. | - | no | - | - |
| 1.002 | OD81602/2026-2027:Electrification charges for pump house including lights, meter board, DB and Earthing | - | no | - | - |
| 2App -B- Providing RWPM and Distribution network. | |||||
| 2.001 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | - | cum | - | - |
| 2.002 | 100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock. | - | cum | - | - |
| 2.003 | 100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited. | - | cum | - | - |
| 2.004 | OD80294/2026-2027:Conveying and fixing G.I. pipes complete with G.I. fittings Excluding trenching, refilling , cost of pipes and fittings for External work: 65mm diameter nominal bore. (Derived from 100.12.7) | - | metre | - | - |
| 2.005 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | - | cum | - | - |
| 2.006 | OD68059/2026-2027:Cutting, Grinding and Welding 65 mm (I.D.) G.I/ S.S/ M.S. pipes for making bends and other specials by gas cutting . Grinding the cut edges / welded portions in M.S. sheet, pipe and specials by grinding machine. Welding pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 3.60 mm to 8 mm thick M.S. plates. | 1 | cm | - | - |
stage.html
html • 0.02 MB
finance_1465435.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 2.88 MB
Tendernotice_2.pdf
PDF • 0.10 MB
Tendernotice_3.pdf
PDF • 0.38 MB
Tendernotice_4.pdf
PDF • 0.12 MB
Tendernotice_5.pdf
PDF • 0.02 MB
Tendernotice_6.pdf
PDF • 0.24 MB
BOQ_1465435.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .