Executive Engineer
Executive Engineer Mechanical Division
Annual maintenance of High wall Cassette Vertical Split AC and Window AC system of College Building New SS Building Animal Building Morgue Building Eye Building Blood Bank and other buildings under AGMC GBP Hospital Agartala Tripura for 1 year
2026_CEPWD_71328_1
92_ EE_DNIT_MECHDIVN_AGT_2526
Open Tender
Electrical Works
Works
365 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹23,286
7 Mar 2026
7 Mar 2026
20 Mar 2026
7 Mar 2026
20 Mar 2026
7 Mar 2026
General servicing of Split type AC machines including all routine & preventive checks/tests/maintenace, cleaning of condenser/evaporator coils with suitable detergent/chemical solution and flushing with high pressure jet of water/blower, filter replacement etc for satisfactory working of the system as per direction of the Engineer In-charge.
1.0 /1.5 / 2.0 TR High wall split type AC.
1.5 TR window type AC.
2.5 /3.0 / 4.0 TR High wall Split, cassette and vertical AC
Leak testing of condenser & evaporator unit for performance and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge.
1.0 / 1.5 / 2.0 High wall split and window type AC.
2.5 / 3.0 / 4.0 TR High wall Split, cassette and vertical AC
Charging / refilling of fresh refrigerant gas (R-22) for 1.0/1.5/2.0/3.0/4.0 TR capacity High wall split / window / cassette / vertical AC system as per direction of the Engineer-in-charge.
R-134,Hydro Carbon, R-600, R-190
Providing and fitting fixing of hermetically sealed non inverter compressor for replacement of defective one as per direction of the Engineer-in-charge. (With one year warranty)
1.0 TR capacity High wall split type AC.
1.5 TR capacity High wall split type AC.
1.5 TR capacity window type AC
2.0 TR capacity High wall split and cassette type AC.
3.0 TR capacity High wall split and cassette type AC.
3.65 TR /4.0 TR capacity vertical split type AC.
Providing and fitting fixing of hermetically sealed inverter compressor for replacement of defective one as per direction of the Engineer-in-charge. (With one year warranty)
1.5 TR capacity High wall split type AC.
2.0 TR capacity High wall split type AC.
Providing and fitting fixing of hermetically sealed copper condenser unit for replacement of defective one as per direction of the Engineer-in-charge.
1.0/1.5 TR capacity High wall split and window type AC.
2.0/2.5 TR capacity High wall split and cassette type AC.
3.0/4.0 TR capacity High wall split and vertical type AC.
Providing and fitting fixing of ODU blower motor of AC systems after rewinding I/C necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-charge.
Providing and fitting fixing of scroll motor (A.C type) of indoor unit split type AC system as per direction of the Engineer-in-charge.
Providing and fitting fixing of scroll motor (D.C type) of indoor unit for inverter technology split type AC system as per direction of the Engineer-in-charge.
Providing and fitting fixing of IDU swing motor of indoor unit split type AC system as per direction of the Engineer-in-charge.
Providing and fitting fixing of inverter PCB circuit of Split type AC system for Indoor Unit complete. as per direction of the Engineer-in-charge.
1.0/1.5/2.0/2.5/3.0 TR split type high wall AC.
2.0/3.0 TR cassette type AC.
Providing and fitting fixing of inverter PCB circuit of Split type AC system for outdoor Unit complete. as per direction of the Engineer-in-charge.
1.0/1.5/2.0/2.5/3.0 TR split type high wall AC.
Providing and fitting fixing of PCB circuit for non-inverter split type AC system with the same/universal PCB circuit as per direction of the Engineer-in-charge.
1.0/1.5/2.0/2.5/3.0 TR split type high wall AC.
Providing and fitting fixing of pump motor for cassette type AC system as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe of appropriate size of (5/8" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units for 1.0 / 1.5 / 2.0 /3.0 /4.0 TR split type high wall,cassette, vertical type ACs.
Providing and fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5) mm or (65x65x5) mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge.
Dismantling, Shifting and re-installation of 1.0/1.5/2.0/2.5/3.0 TR window, split and cassette, vertical type AC system as per direction of the Engineer-in-charge.
Providing hard/ coil PVC pipe of good quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit to nearest disposal as per direction of the Engineer-in-charge
Providing and fitting fixing of accessories during maintenance work of split/window AC as per direction of the Engineer-in-charge.
Capacitor 2.0/2.5/4.0/5.0 µF
Capacitor 25 µF
Capacitor 36 µF
Capacitor 45 µF
Capacitor (50-60) µF
Capacitor (80-120) µF
Terminal Clip
PVC tape (Black tap)
Thermostat for split type AC system
Thermostat for window type AC system
Relay for split type
Relay for window type
Contactor
Coil sensor
Room sensor
Display with sensor
Capillaries/ Dryer
Nitral tape (Arrow tape)
Remote with battery
Connector
Air Filter
Single core copper wire 1.5/2.5 Sq.mm made of (Havels/Anchor)
General Checking of Split type AC machines for functioning and minor repairing without replacement of spare parts
Supply and installation of additional length of electrical copper wire 4 sq mm size with casing size 01 (One) inch including other materials to connect outdoor unit with electrical panel as per direction of the Engineer-in-charge.
Providing & fitting fixing of fan blade of outdoor unit of window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge.
Providing & charging of compressor oil with capillary complete as per direction of the Engineer-in-charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
DNIT.pdf
Tender Documents • 2.91 MB
BOQ_72580.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .