Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Annual Maintenance of Split type 1.0/1.5/2.0 TR and Window type 1.5 TR Air Conditioning Systems installed at Old SS Block, Ophthalmic Department Old Hospital Building, Jayanti Block and Dedicated Covid wards of AGMC Blood Bank, Central Laboratory, Ad
2023_CEPWD_38865_1
12/EE/DNIeT/MECH.DIVN/AGT/2023
Open Tender
Electrical Works
Works
365 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹48,144
1 Dec 2023
29 May 2023
12 Jun 2023
29 May 2023
12 Jun 2023
29 May 2023
Amount
General servicing of 1.0TR/1.5 TR/2.00 TR capacity split type AC machines including overhauling, dismantling fabrication, cleaning, reassembling, greasing, all routine & preventive checks/tests/maintenace, cleaning of condenser/evaporator coils with suitable detrgent/chemical solution and flushing with high pressure jet of water/blower, filter replacement etc for satisfactory working of the system as per direction of the Engineer In-charge.
General servicing of 1.5 TR capacity window type AC machines including overhauling, dismantling fabrication, cleaning, reassembling, greasing, all routine & preventive checks/tests/maintenace, cleaning of condenser/evaporator coils with suitable detrgent/chemical solution and flushing with high pressure jet of water/blower, filter replacement etc for satisfactory working of the system as per direction of the Engineer In-charge.
Leak testing of all coils and connections, pressure testing for (1.0TR/1.5 TR/2.0 TR) Split type AC Machines and repair with brazing as per direction of the Engineer In-charge.
Leak testing of complete refrigerant circuit, pressure testing for 1.5 TR window types A/C Machines and repair with brazing as per direction of the Engineer In-charge.
Providing & charging of refrigerant gas for (1.0/1.5/2.0) TR Split, window AC machines as per direction of the Engineer In-charge.
Providing & fitting fixing of Swing motor for AC machines as per direction of the Engineer In-charge
Providing, fitting, fixing, testing of Hermetically sealed Compressor for following capacity split type AC machines as per direction of the Engineer-in-charge (with one year warranty).
Providing, fitting, fixing, testing of Hermetically sealed Compressor for 1.5 TR capacity Window type AC machines as per direction of the Engineer In-charge.(with one year warranty).
Providing, fitting, fixing, testing of hermetically sealed Condenser unit for following capacity split type/window type A/C machines replacing old one as per direction of the Engineer-in -charge.
General checking of split/window types AC systems for functioning & repairing with out replacement of spare parts.
Providing and fitting fixing of additional copper pipe for split AC/window types ( 5/8″,1/4″) dia. Size and necessary wiring to connect indoor and outdoor units.
Fitting fixing, rewinding of ODU blower motor for AC machines as per direction of the Engineer-in -charge.
Providing & fitting fixing IDU scroll motor for AC machines as per direction of the Engineer-in -charge.
Providing & fitting fixing of Capacitor as per direction of the Engineer-in-charge. a)25µFcapacitor
25µFcapacitor
36µFcapacitor
45µF,capacitor
(50-60)µFcapacitor
(120-180)µFcapacitor
Providing & fitting fixing of Relay as per direction of the Engineer-in-charge.
Providing & fitting fixing of Air filter(coir) as per direction of the Engineer-in-charge.
Repair of PCB Circuit for successful functioning of split/window AC System As per direction of the Engineer-in-charge.
Providing & fitting fixing of ODU Fan blade for split type AC System as per direction of the Engineer-in-charge.
Providing & fitting fixing of MS platforms (50*50*5) mm by using MS Angles base plate as per direction of the Engineer-in-charge.
Providing & fitting fixing of G.C.I. shed of two parts slanting with ridge by using MS Angles (30*30*5)mm size baser plate as per direction of the Engineer-in-charge.
Providing and fitting fixing of 1″ PVC drain pipe 25mm dia.
Dismantling and re-installation of split/window (1.0TR/1.5TR/2.0TR/3.0TR) types AC machine as per direction of the Engineer-in-charge.
Providing and fitting fixing of thermostat as per direction of the Engineer-in-charge.
Supply of spare parts:-
Terminal clip
PVC tap(black/red)
Single core 1.5/2.5 Sq.mm made of (havels/anchor)
Providing and fitting fixing of inverter PCB circuit for 1.5 TR Split type AC system for outdoor unit complete.
Providing and fitting fixing of inverter PCB circuit for 1.5 TR Split type AC system for Indoor unit complete.
Providing and fitting fixing of inverter PCB circuit for 2.0 TR Split type AC system for outdoor unit complete.
Providing and fitting fixing of inverter PCB circuit for 2.0 TR Split type AC system for Indoor unit complete.
Providing and fitting fixing of non-inverter PCB circuit for 1.5 TR complete
Providing and fitting fixing of non-inverter PCB circuit for 2 TR Split type AC system
Provifing and charging of Compressor oil with capillary complete.
Deployment of 3 (three) nos. technicians, one in each of 3(three) shifts, round the clock, 24 x7 basis to attend immediately as and when required on urgent basis for carrying out items of work under AMC.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_39475.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .