| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L1 | Accepted-AOC Acceptance of Contract | |
| 2 | L2₹28.6 L+₹10,999 (0.39%)Rejected-AOC 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L2 | Rejected-AOC OK | |
| 3 | L3₹29.5 L+₹93,849 (3.29%)Rejected-AOC 117 BHAISAHIYA TOLA GANESHGANJ MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | MIRZAPUR | UTTAR PRADESH | 231001 | L3 | Rejected-AOC OK | |
| 4 | L4₹29.6 L+₹1.1 L (3.78%)Rejected-AOC | L4 | Rejected-AOC OK | |
| 5 | L5₹29.7 L+₹1.2 L (4.21%)Rejected-AOC 292 KRISHNA COLONY OLD HAMIDA SAHARANPUR ROAD YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L5 | Rejected-AOC OK |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
DAY TO DAY MAINT PETTY REPAIRS OF ELECTRIC SUPPLY OF OTM AND MD ACCN AT SOUTH COMPLEX UNDER GE IMA DEHRADUN
2024_MES_676033_1
GE/IMA/T-74 of 2024-2025 9472/E8
Open Tender
Support/Maintenance Service
Item Rate
334 days
GE IMA Dehradun
As per Critical dates
6 documents required · 6 mandatory
₹500
Yes
₹90,000
Yes
5 Dec 2024
23 Sept 2024
23 Oct 2024
24 Sept 2024
21 Oct 2024
7 Oct 2024
Amount
M&L for attending all type of electric complaint in the blocks/qtrs/lines/ offices in the OTM/Md Accn due to any reason like MCBs/MCCBs burnt out/tripping, leakage fault, short/open circuit faults, electric fittings/fixtures, all type of controls, controls of garden/street lights,controls of summer and cooling appliances i.e Fan , Exhaust Fan , Wall Fan ,Geyser, ACs etc.with rectification and restoring the supply by trained Electrician complete all as specified and directed for the South complex OTM/Md Accn Area ( Thimaya Bn, Cariappa Bn, Bhagat Bn, Manekshaw Bn) ,VB Mess , MT colony and Misc area inside the South Complex.
Note: (i) All the T&P items like aluminium folding self supported ladders as per site requirement, drill machines with bits, cutting plier, spanners, Allen key Set, Pipe wrench, Screw driver Sets, Crimping tool,descaling rod, etc will be provided to electricians by the contractor. The cost of T&P shall be inciuded in quoted rates and no extra cost will be paid by department. Tool Bags required for attending the complaint shall also be provided by contractor to the tradesmen.All the stationery i.e complaint register, job card dockets and other connected register related to the work shall be arranged and to be maintained by the contractor.Stores required for day to day maintenance for all repair work provided by the contractor through this contract. All sundries items like Insulation Tape, Screws, washers, Plastic wall rawal plugs, Nuts, Bolts, dummy plates, thimbles for coper wire etc shall be supplied/ arranged by the contractor without any extra cost to Govt. All the retrieved material shall be the property of Contractor with Sch of credit as shown on credit schedule.Contractors are advised to visit the site before quoting rates.Contractor shall be penalised @ Rs. 200/- per complaint/ day, if he fails to attend and rectify the complaint within 24 hours of lodging the complaint either personally or telephonically. In this regard the decision of the Engr-in-Charge shall be final & binding.
The employed electrician should be qualified with ITI in concerned trade and shall have minimum 03 years experience. Work shall be carried out as per modern engineering practice and contractor to maintain record register, duty roster, attendance register etc complete alongwith general tool safety measures on conveyance/ transportation uniform etc. All workers employed by the contractor in day to day maintenance is mendatery to wear proper uniform. Any stores required for rectification of electric complaints other than item mentioned in CA is provided by the department.Unit rates also include 1 electrician (SK) each and 1 electrician helper (SSK)each (1+1) x2=4 persons)in two shifts with deployed in South Complex Complaint cell for rectification of complaints including sunday & holidays from the date of commencement of work. Conractor should also provide almirah to electricition employed under the contract to keep their tool bags /stationary etc in safe custody.Unit rates also include the conveyance and communication facility requried to complete the Job.
S & F in repairs single core FR-LSH PVC insulated copper multi stranded conductor cable drawing into existing/new PVC rigid conduit in surface/concealed as required complete of following sizes as directed. Make:- Havells/Polycab/Grandlay/SCI/Plaza.
S&F door bell ding dong type, AC, 240 volts, single pole complete all as specified and directed by Engr-In-Charge. Make :- Anchor/Havells/Indo Asian.
S&F ceiling rose 3 phase pvc/polycarbonate, isolated body white in colour complete all as specified and directed by Engr-In-Charge. Make - Anchor/Legrand/Havells.
S&F Angle holder, insulated polycabonate body with back plate white in colour suitable for batten fittings including one number LED lamp 9 watt complete all as specified and directed by Engr-In-Charge. Make of angle holder: Havells/Anchor/Legrand Make of Bulb: Havells/Crompton/Philips
S&F LED tubelight batten fitting 20 Watt made of aluminium housing suitable for fixing on walls/ceiling, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge. Make: BRIGHT LINEA of Crompton/LUMILINE PLUS NEO of Havells/ Essential SmartBright Batten of Philips/Eveready
S&F LED flood light fitting 50 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection suitable for fixing on walls, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge. Make: ROVER of Crompton/JETA QUANTO PLUS of Havells/Uniflood of Philips/Eveready
S&F LED tubelight batten fitting 10/12 Watt made of aluminium housing suitable for fixing on walls/ceiling including connections, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge. Make: Trim Linea Neu of Crompton/SmartBright of Philips/ENDURA LINEAR NEO of Havells/Eveready
S&F LED bulk head fitting 10 W pressure die cast aluminium housing IP 65 including connection complete all as specified and directed by Engr-In-Charge.Make- SUNRISE of Crompton or equivalent in Havells/Philips as approved.
Supplying, fixing & testing LED 36 Watts,2'x2' recessed ceiling light fitting,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- POLARIS NIO I-II of Crompton/VENUS NEO 2X2 of Havells/SmartGlow of Philips/Eveready as approved.
Supplying, fixing & testing LED 36 Watts,2'x2' surface mounted ceiling light fitting,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- POLARIS NIO III LCTLSNE-36-FO-CDL of Crompton/PLUTO PANEL (SURFACE) of Havells or equivalent in Philips/Eveready as approved.
Supplying, fixing & testing LED 15/16 Watt surface mounted round/square ceiling light fitting,warm /natural/ cool white as per requirement at site made of aluminium housing high translucent frosted plastic diffuser with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- PEARL NIO-S of Crompton/INTEGRA NXT SURFACE ROUND/SQUARE of Havells/Sleek Surface Downlight of Philips/Eveready as approved.
Supplying, fixing & testing LED 18 Watt recess mounted round ceiling light fitting,warm /natural/ cool white as per requirement at site made of aluminium housing high translucent frosted plastic diffuser with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- PEARL ULTIMA of Crompton/INTEGRA HE of Havells/GreenPerform Sleek of Philips/Eveready as approved.
S&F plug and socket metal enclosure box of module (2P+E- SP), IK 08, supplied with Neutral Links complete with one MCB SP 20 amp,240 Volts recess mounted with chained metal cover for the socket outlet complete all as specified and directed by Engr-In-Charge. Make:- Legrand/Havells/Indo Asian/HPL.
S & F sub main wiring with PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in and including rigid PVC conduit of size not less than 25 mm dia in concealed / surface as required at site including one run PVC insulated unsheathed cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unsv submain wiring of following sizes complete all as specified and directed. Make of wire:- Havells/ Grandlay/ SCI/Plaza Make of conduit: Finolex/AKG Plastic Ltd. Bhagwati Agriculture,Plaza. Note: (i) Two/Four run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. (iii) Phase sequence colour code must be follow i.e Phase( Red) and Neutral ( Black) In colour and for three Phase RYB For phase and black for neutral.
2 x 10 Sqmm + 1 x 10 Sqmm
2 x 6 Sqmm + 1 x 6 Sqmm
2 x 4 Sqmm + 1 x 4 Sqmm
4 x 16 Sqmm+ 1 x 10 Sqmm
S & F VTPN Distribution boards epoxy powder coated fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with fully insulated 250 Amps copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 IK -09,415 volt with provision for 160/200 Amp MCCB FP adjustable type as incomer and SP MCBs or TP MCBs as per site requirement (or any combination of SP/TP MCBs) outgoings of following capacity.
4 Way VTPN DB (FP MCCB + 12 MCBs). Make: 507745 of Legrand or equivalent in Havells, Indo Asian, HPL.
8 WAY VTPN DB TP&N DB(FP MCCB + 24 MCB,s) Make: 507747 of Legrand or equivalent in Havells, Indo Asian, HPL.
12 WAY VTPN DB TP&N DB(FP MCCB + 36MCB,s) Make: 507748 of Legrand or equivalent in Havells, Indo Asian, HPL.
S & F in repair MCB DB complying with IEC 61439 -1 & 3., sheet metal enclosures double door with provision for 01 x 40 to 63 A SPN MCB as incoming and MCB SP 6 to 32A as out going as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 200A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity. Make:- Legrand,Havells, Indo Asian, HPL.
4 way SPN DB.
8 way SPN DB.
12way SPN DB.
S & F in repairs MCCB ICS=100% ICU at 415 volts with thermal-magnetic release and adjustable overload setting complete all as specified and directed of following capacity. Make:- Legrand, Havells, Indo Asian, HPL.
100 Amps 3 pole 25 KA
125 Amps 3 pole 25 KA
160 Amps 4 pole 36 KA.
200 Amps 4 pole 36 KA.
S & F in repairs MCB SP complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable complete all as directed of follwing capacity: Make:- Legrand, Havells, Indo Asian, HPL.
MCB SP 6 to 32 Amp.240 volts
MCB SPN 40 to 63 Amps 240 volts
S & F in repairs MCB TPN/FP 40 to 100 Amp as per requirement complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable complete all as directed of follwing capacity: Make:- Legrand/Havells/Indo Asian/HPL.
S & F in repair TPN DB 4 way complying with IEC 61439 -1 & 3., sheet metal enclosures double door with provision for 01 x 63/100 A `TPN MCB as incoming and MCB SP 6 to 32A as out going as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 200A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity. Make:- Legrand/Havells/Indo Asian/HPL.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20 mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge.
S&F in replacement of UNSV rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces of following sizes:- Make:- AKG Plastic Ltd., Bhagwati Agriculture, Finolex.
25 mm dia
32 mm dia
S& F modular fitting /fixture in repairs including taking down old unsv fitting/fixture of following specification:- Make: Anchor/Legrand/Havells
Fan regulator modular step type 100W 240 volts 2 module.
Modular switch single pole one way 6 Amp 240 volts.
Modular switch single pole one way 16 Amp 240 volts .
Modular socket outlet 2/3 pin combined 6 Amp 240 volts.
Modular socket outlet 2/3 pin combined 16 Amp 240 volts.
Modular bell push flush type, 6 Amps 240Volts.
S& F fitting /fixture in repairs including taking down old unsv fitting/fixture of following specification:- Make: Anchor/Legrand/Havells
Fan regulator step type 100W 240 volts 2 module.
piano type switch single pole one way 6 Amp 240 volts.
piano type switch single pole one way 16 Amp 240 volts .
socket outlet 2/3 pin combined 6 Amp 240 volts.
socket outlet 2/3 pin combined 16 Amp 240 volts.
bell push flush type, 6 Amps 240Volts.
S&F modular switch socket combination box 16 Amp, 6 pin, 3 module (2 hole complete with suitable connection with 2x2.5 sqmm and 1x1.5 sqmm single core cable length upto 01 mtr complete all as specified and directed by Engr-In-Charge. Make: Anchor/Havells/ Legrand as approved.
S&F in repairs white modular cover plate with frame of following module complete including taking down old unsv modular cover plate with frame all as directed.Note: It is responsibility of contractor to make good of disturbed surface by using plaster and putty. Make: Anchor/Legrand/Havells
1Module
2Module
3Module
4Module
6Module
8 Module
12 module
S&F in repairs modular metal flush box of following module complete including taking down old unsv modular metal flush box with frame all as directed.Note: It is responsibility of contractor to make good of disturbed surface by using plaster and putty. Make: Anchor/Indo Asian/Havells
1Module
2Module
3Module
4Module
6Module
8 Module
12 module
S&F plug top 3 pin 16 Amp 240 V plastic body white in colour complete all as specified and directed by Engr-in-Charge.Make: Anchor/legrand/havells
Supplying, fixing & testing LED 40 Watts,4'x1' recess ceiling light fitting suitable for POP/grid ceiling,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- SPAN LCTLRNE-40-CDL(1X4) of Crompton/PLUTO NEO PANEL 4X1 of Havells/ FullGlow 1'x4' of Philips as approved. Note: It is to be noted that any gap created by dismantling old light and fixing the LED light will be filled with POP and match with the existing surface.
Supplying, fixing & testing LED 40 Watts,4'x1' surface mounted ceiling light fitting suitable for POP ceiling,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- SPAN LCTLSNE-40-CDL(1X4) of Crompton PLUTO NEO PANEL 4X1 of Havells/FullGlow 1'x4' of Philips as approved.
Supplying, fixing & testing LED 24 Watts,1'x1' recessed ceiling light fitting suitable for POP ceiling,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- POLARIS NIO I-II LCTLRNE-24-CDL(1'x1') of Crompton/PLUTO 1X1 of Havells or equivalent in Philips as approved.
S&F P-17 Tempra plug & socket DB's of module (3P+N+E- FP) , IK 08, supplied with Neutral Links complete with MCB FP 32 amp, 415 volts recess mounted with industrial plug top complete all as specified and directed by Engr-In-Charge. Make:- Legrand/Havells/HPL/Indo Asian
S & F in repairs two core FR-LSH PVC insulated copper multi stranded conductor cable drawing into existing/new PVC rigid conduit in surface/concealed as required complete of following sizes as directed. Make:- Havells/Grandlay/SCI/Plaza
S & F in repairs three core FR-LSH PVC insulated copper multi stranded conductor cable drawing into existing/new PVC rigid conduit in surface/concealed as required complete of following sizes as directed. Make:- Havells/Grandlay/SCI/Plaza
S&F electric PVC casing caping trunking system of size 100 x 100 mm ISI marked and laying the cables inside the trunking system for proper mounting on the walls complete all as specified and directed by Engr-In-Charge. Make:- AKG Plastic Ltd., Bhagwati Agriculture, Finolex, Plaza.
S&F LED decorative wall light fitting made of stainless steel, rust free fixture with glass diffuser along with 9 Watt LED Bulb complete all as specified and directed by Engr-In-Charge. Make: Florette WL 1LS E27 SS of Havells or equivalent in Crompton/Philips
Supply and fix in replacement Exhaust fan 250 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make : BAJAJ/HAVELLS /Crompton
M/S K K ENTERPRISES (BID ID -3139190)
prabhawati shanti automobiles (BID ID -3138414)
Balraj and Co (BID ID -3145321)
M/S Durvish Mourya (BID ID -3145827)
Bhanu Prakash (BID ID -3139018)
M/S S P BUILDERS (BID ID -3139009)
Deven Associates (BID ID -3139082)
Friends fire Engineers (BID ID -3146199)
JS CONSTRUCTION COMPANY (BID ID -3138654)
Mohinder Pal and Sons (BID ID -3140732)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .