| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC | ₹39.0 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹40.0 LRejected-AOC | ₹40.0 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹42.5 LRejected-AOC | ₹42.5 L | L3 | Rejected-AOC Rejected |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-As per the pre bid venue the bimla enterprises not attend the pre bid meeting and the site visit certificate not issued by unit. certificate of additional term and condition not recd. |
| Sl No | Description | Qty | Unit | Tadik Jempen L3 | Kesang Naksang L1 | M/s Pale Enterprise L2 |
|---|---|---|---|---|---|---|
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. | ||||||
| 1.01 | Ordinary rock. | 22.5 | cum | 275 ₹6,187.50 | 265.35 ₹5,970.38 | 268 ₹6,030 |
| 1.02 | Filling available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each layer by ramming and watering, lead up to 50m and lift upto 1.5m | 23.55 | cum | 302 ₹7,110.59 | 295.25 ₹6,951.66 | 300 ₹7,063.50 |
| 1.03Supplying chemical emulsion in sealed containers including delivery as specified | ||||||
| 1.04 | (a) Chlorpyriphos Emulsifiable concentrate 20% @' 1.0 ltr per sqm of covered area | 112.72 | ltr | 252 ₹28,404.68 | 242.65 ₹27,350.78 | 245 ₹27,615.67 |
| 1.05 | Stone soling under floors including watering,
ramming consolidating and dressing complete: upto 5 km | 8.74 | cum | 1,900 ₹16,600.30 | 1,862.41 ₹16,271.88 | 1,866 ₹16,303.24 |
| 2.00CONCRETE WORK | ||||||
| 2.01Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering in footings and bases of columns (All work upto plinth level). | ||||||
| 2.02 | 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) | 9.04 | cum | 7,700 ₹69,569.50 | 7,658.51 ₹69,194.64 | 7,700 ₹69,569.50 |
| 2.03 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4graded stone aggregate 20 mm nominal size.) | 6.9 | sqm | 501 ₹3,456.90 | 409.54 ₹2,825.83 | 450 ₹3,105 |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
13 Nov 2025, 9:30 amClosed
Commanding Officer, 22 SIKH
Main Office 22 SIKH Pin 912222 C/O 99 APO, Menchuka
DEVLOPMENT OF CAFE AT LAMANG, ARUNACHAL PRADESH
2025_ARMY_738169_1
A/SAD/56IB/5IB/41/25-26
Open Tender
Construction Works
60 days
LAMANG, Shi-Yomi ARUNACHAL PRADESH
As per RFP Document
2 documents required · 2 mandatory
₹100
Commanding Officer 22 SIKH
₹78,000
Main Office 22 SIKH Pin 912222 C/O 99 APO, Menchuk
20 Jan 2026
3 Nov 2025
13 Nov 2025
3 Nov 2025
13 Nov 2025
3 Nov 2025
3 Nov 2025 - 13 Nov 2025
7 Nov 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
Ordinary rock.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each layer by ramming and watering, lead up to 50m and lift upto 1.5m
Supplying chemical emulsion in sealed containers including delivery as specified
(a) Chlorpyriphos Emulsifiable concentrate 20% @' 1.0 ltr per sqm of covered area
Stone soling under floors including watering, ramming consolidating and dressing complete: upto 5 km
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering in footings and bases of columns (All work upto plinth level).
1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4graded stone aggregate 20 mm nominal size.)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
R.C.C WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement.
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work from plinth level upto floor roof lvl
(a) Walls, columns, pillars, posts and struts
(b) Beams, plinth beams, girders, bressumers, cantilevers, suspended floors lintels roofs and staircases including spiral staircases, shelves etc. (refer beam column measurements)
FORMWORK
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc. for mass concrete.
Suspended floors, roofs, landings, balconies, shelves and access platform.
Lintels, beams, plinth beams, girders, bressummers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Ramps
Walls
STEEL REINFORCEMENT
Reinforcement of RCC work including straightening, cutting, bending, placing in position and binding all complete. Cold Twisted Bars
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V evel in all shapes and sizes in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
FLOORING
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone
FINISHING
12 mm thk cement plaster 1: 4 (1 cement : 4 coarse sand) on walls.
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement :4 coarse sand)
6 mm thick cement plaster (1 cement : 3 fine sand) to ceiling.
Providing and applying white cement based putty of avg thickness 1.0 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
White washing with lime to give an even shade.
New work (three or more coats)
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
Applying one coat of cement primer approved brand and manufacturer on wall surface :
WOOD WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :
Kiln seasoned and chemically treated hollow wood Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.
Kiln seasoned and chemically treated hollock wood Wooden Partion of 75 mm thk provided internally
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part-I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI Marked Stainless
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) Transparent or dyed to required colour or shade, with necessary screws etc. complete: (a) 125 mm
Providing and fixing aluminum hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper.
Providing and fixing aluminum hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (a) 250x10 mm
Providing and fixing MS grills of required pattern in frames of windows etc. with MS Flats, square or round bars etc.including priming coat with approved steel primer all complete.
Fixed to steel windows by welding
STEEL WORK & ROOFING
Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self
drilling/ self tapping screws complete :
(a) Ridges plain (500 - 600mm)
(b) Gutter (600 mm over all girth)
Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm false ceiling
Weight to be carried by head load from to work site.
Estimate - Internal Electrical Installations
POINT WIRING
Point wiring in PVC conduit, with modular type switch
Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required
Group C
Circuit/sub-main wiring in PVC conduit:-
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor,single core cable in surface/recessed PVC
(a) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (for ckt wiring)
(b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire (for power plug)
(c) 2 x 6 sq. mm + 1 x 6 sq. mm earth wire
(d) 2x10 sq.mm+ 1x10sq. Mm earth wire.(for Common Area DB)
(e) 4x10 sq.mm+ 2x10sq. Mm earth wire.(for DB's)
(f) 4x16 sq.mm+ 2x16sq. Mm earth wire.(for DB's)
Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
(a) 3X4 Sq. mm
(b) 3X6 Sq.mm
TV Cable in existing Conduit
Supplying and drawing co-axial TV Cable RG - 6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in thye existing surface/ recessed steel/ PVC conduit as required.
S/F PVC conduit :
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
S/F modular type switch/socket :
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
(a) 5/6 amps switch
(b) 3 pin 5/6 amp socket outlet
(c) TV Antenna Socket Outlet
S/F modular type electronic fan regulator :-
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
S/F modular boxes, base & cover plate :-
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
(a) 1 or 2 Module (75 mm x 75 mm)
(b) 4 Module (125 mm x 75 mm)
S/F light plug point modular type accessories:
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.
S/F power plug point modular type accessories:
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
ITC ceiling fan :
Installation, testing and commissioning of ceiling fan including the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insualted, copper conductor, single core cable and earthing etc. as required.
ITC exhaust fan upto 450 mm sweep :
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, coonection, testing, commissioning etc. as required
Fixing louvers/shutters for exhaust fan
Extra for fixing louvers/shutters complete with frame for a exhaust fan of all sizes.
MCB DISTRIBUTION BOARDS
S/F prewired SP MCB DB :-
Supplying and fixing following way, single pole and neutral, prewired, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with loose wire box, terminal blocks, duly prewired with suitble size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator)
(2 +4) way Double door
S/F prewired TP MCB DB :-
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete with loose wire box, terminal connectors for all incoming & outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator)
8 way (4+24), Double door
Vertical TPN DB
Supplying & fixing following ways surface/ recess mounted, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 100 amps TP 16 KA MCCB as in comer, interconnection between incomer MCCB & busbars (but without MCB's/ MCCB) as required.( Note: Vertical type MCB TP DB is normally used where 3 Phase outlets are required.)
8 Way TP
Providing & fixing following rating & breaking capacity & pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connection, etc. as required.
100 Amp, 16 KA, TP MCCB
S/F 'C' curve, SP MCB
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required.
Single Pole
Supplying and fixing following rating ,double pole (single phase and neutral ),240 Volts, residual current circuit breaker (RCCB), having senstivity crrent up to 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F 20A SPN MCB Industrial Socket outlet
Supplying & Fixing 20 Amps, 240Volts, SPN Industrial Type Socket Outlet, with 2 Pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing & commissioning as required.
Providing & fixing M.V danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red color on front side as required
EARTHING
Earthing with G.I earth pipe 4.5 mtr long , 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.with charcoal and salt complete as required.( External Poles)
Earthing with G.I earth plate 600mm X 600 mm X 6 mm thick including accessories, & providing mansonary enclosure with cover plate having locking arrangement & watering pipe of 2.7 Metre long etc. with charcoal/ coke & salt as required( Equipments)
Earthing with copper earth plate 600mm X 600 mm X 3 mm thick including accessories, & providing mansonary enclosure with cover plate having locking arrangement & watering pipe of 2.7 Metre long etc. with charcoal/ coke &
Providing and fixing 25 mm x 5 mm G.I earth strip from earth electrode as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required
SUPPLY OF LIGHTING FIXTURES & FANS
Supplying the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. Use all Philips Trulite/Osram lumilux plus Eco lamps in Fluorescent lamp fittings. ( 4000 K) Use Osram CFL lamp - Dulux L Lumilux in all CFL lamp fixtures (4000 K) (Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures)
All Light Fixture shall be with H.F. electronic ballast ( THD less than 11% and P.F. 0.95 )
(a) 2 X 36 watts CFL recessed mounted light fixture as per Wipro Cat. No. WVP 74236
(b) 12" dia 1 phase exhaust fan, 1400 RPM
(c) 2x18 Watt CFL Light fixture as per Wipro Cat. No. WCP 36218 SGW or as equivalent
(d) 48" dia (1200 sweep) ceiling fan
SANITARY FIXTURES & ACCESSORIES
Providing and fixing white vitereous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.
W.C pan with ISI marked white solid plastic seat and lid.
Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required.
White Vitreous china Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.
(a) 32 mm dia (for wash basin)
(b) 40 mm dia (for sink and urinal)
Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing & fixing viterous china toilet paper holder.
Providing & fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board.
510 x 1040 bowl depth 250 mm
WATER SUPPLY PIPES AND FITTINGS
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.
Concealed work including cutting cheases and making good the walls etc.
(a) 15mm nominal outer dia pipes
(b) 20mm nominal outer dia pipes
(c) 25mm nominal outer dia pipes
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge.
40mm Nominal outer dia pipes
Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
25 mm nominal bore
Providing & fixing unplasticised PVC connection pipe with brass unions. 15 mm nominal bore 45 cm long
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931. (15 mm nominal bore)
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms (15 mm nominal bore).
Providing and fixing brass stop cock of approved quality: 15mm Nominal bore
Providing & fixing C.P brass shower rose with 15 mm inlet. (100 mm dia).
PART B (NON-SCHEDULED ITEMS - AS PER MARKET RATES)
Providing and fixing of C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. (Jaquar 573 or equivalent)
Providing and fixing of 32 mm dia. C.P.Brass bottle trap with 190 mm long wall connection pipe in place of P.V.C. waste pipe for wash basin discharge. (Jaquar 773 or equivalent)
Providing and fixing of 600 mm long C. P. brass towel rail complete with C.P. brass brackets. (Jaquar 1111 or equivalent)
Providing and fixing of 15 mm dia. inlet C.P. brass adjustable shower with 190 mm long shower arm complete with flange of approved quality. (Jaquar 477 + 493 or equivalent)
M/s Pale Enterprise (BID ID -3471335)
Tadik Jempen (BID ID -3471360)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
dtfrfp.pdf
Tender Documents • 0.50 MB
BOQ_826553.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid