Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.0 LAccepted-Finance PLOT NO 66 RESHAM GHAR COLONY JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | 1 | Accepted-Finance Found Eligible | |
| 2 | 2₹2.1 L+₹12,500 (6.30%)Accepted-Finance | 2 | Accepted-Finance Found Eligible | |
| 3 | 3₹2.2 L+₹18,300 (9.22%)Accepted-Finance | 3 | Accepted-Finance Found Eligible | |
| 4 | 4₹2.2 L+₹23,500 (11.8%)Accepted-Finance 25 PRATAP COMPLEX GULAB SINGH MARG JAMMU | 4 | Accepted-Finance Found Eligible | |
| 5 | 5₹2.3 L+₹29,360 (14.8%)Accepted-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | 5 | Accepted-Finance Found Eligible |
Tender Value
Refer Docs
Closing Date
16 Jan 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, MID Akhnoor Nowshera
Office of Executive Engineer, MID Akhnoor Nowshera
P,F,I of FASD Starter-Cum Protection panel complete with over current, under current, over under voltage, single phase prevention with one number incoming and two outgoing pane
2023_IFC_201739_1
MID/AN/157
Open Tender
Electrical and Maintenance Works
Item Wise
45 days
RAJAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Executive Engineer, MID Akhnoor Nowshera
Exempted
Office of Executive Engineer, MID Akhnoor Nowshera
21 Jan 2023
6 Jan 2023
17 Jan 2023
6 Jan 2023
16 Jan 2023
8 Jan 2023
7 Jan 2023
Providing and Fitting/installation of New Fully Automatic Electric Control panel/FASD Starter-Cum-Protection panel complete with over current, undercurrent, over& under voltage, single phase prevention with one number incoming and two outgoing panel circuits and all digital measurement devices with allied works for 0.22 cusec discharge × 57mtrs head pump with 15 HP motor by way of designing, fabrication, installation, testing and commissioning of LT control panel 380 volts, AC-3 Phase, 50 Hz. for pumping unit no. 01 & 02 at L.I.S Kalsian .The panel shall be dust and vermin proof fabricated out of 16 SWG CR Sheet supported on M.S. angle of suitable size and having provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: Incommer The panel should be fitted with an M.C.C.B. of 125 Ampere capacity, 1 No. volt meter, 1No ammeter along with a set of CTs, 1 No. V.S.S., 1 No. A.S. switch and a set of RYB indicators at incoming side including the bus bars . Outgoing no. 1 & 2 :The panel should be fitted with a 15 HP automatic star delta starter comprises one number 63 Ampere, 3 pole MCCB, 3 Nos. air break contactors compatible with 15HP induction motor (2 Nos. 40 A for main and delta supply, 1 No. air break contactor 40 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, complete neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no. 1 & 2. Protection device / fault analyzer : A protection device / fault analyzer shall be fitted with the panel with capability to protect each motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings : A. Voltage related fault: Single phasing, under voltage, over voltage, unbalance voltage. B. Current related fault: Under Current, Over current / load, dry running, unbalance current / load, earth leakage, short circuiting. C. Display line current of RYB Phase and also line voltage of RY ,YB and BR phase. Bimetal overload relay: Bimetal over load relay of suitable range should be fitted with in the each starter as an extra protection to protect the motors in case of failure of fault analyzer . Providing/ fitting of copper cable 20mtrof size 6 sq. mm from starter no. 01 & 02 to motor no. 1 & 2. Complete job includes cost of providing/ fitting ,transportation charges ,hire charges of tool and tackles charges, hire charges of skilled and unskilled labour, and all kinds of taxes thereof. complete job. Make of MCCB – Any reputed make as per ISO standards.. Make of contactor – Any reputed make as per ISO standards... Make of cable – Any reputed make as per ISO standards..
SUNIL KUMAR SURI CONTRACTOR
M/S SHAKTI MOTORS
M/S Tawi Engineers
NATIONAL ELECTRO-MECH COMPANY
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .