Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.9 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical JALALIYA BUILDING 1ST FLOOR MASJID ROAD ALUVA ERNAKULAM 683101 | ALUVA | ERNAKULAM | KERALA | 683101 | - | Rejected-Technical Specification mismatch | |
| 3 | Rejected-Technical | - | Rejected-Technical Specification mismatch | |
| 4 | Rejected-Technical 6 270 LALITA PARK LALITA PARK LAXMI NAGAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Specification mismatch |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
9 Jan 2020, 3:00 pmClosed
Principal
MVGM GPC Vennikulam, Thiruvalla, Pathanamthitta
Purchase of Diesel Generator
2019_DTE_326698_1
A6/1557/2019
Open Tender
Equipments
Item Wise
30 days
MVGM GPC Vennikulam, Thiruvalla
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,100
Yes
online
₹10,000
Yes
MVGM GPC Vennikulam, Thiruvalla
14 Aug 2020
3 Dec 2019
13 Jan 2020
4 Dec 2019
9 Jan 2020
6 Dec 2019
4 Dec 2019 - 16 Dec 2019
6 Jan 2020
DIESEL GENERATOR SET SUPPLY INSTALLATION AND COMMISSION
DIESEL GENERATOR SET : Power rating 82.5kVA/66kWe, 3Phase 415V 50Hz., Power factor 0.8 lagging, Current 114Amps, 1500 rpm., MoEF Certified Power(bhp) 110, Required power for Rated kVA(bhp) 105, 4 cylinder in-line liquid cooled turbo charged engine, Fuel consumption @75% load (litre/hour)-14 to 16, Fuel consumption @100% load (litre/hour)-19 to 20, Starting system 12V DC electrical battery and charging system, Alternator Voltage regulation (Max.) ±1%, Class of Insulation H Class, Winding Pitch 2/3, Rotor Dynamically Balanced , Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting, balanced linear load < 5 %, Maximum Unbalanced Load across phases- less than or equal to 25%, Telephonic Harmonic factor < 2% , Control panel manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. (1 No) INSTALLATION: Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), (3 Nos) 300 x 300 x 6 mm cast iron gully trap with covering (3 Nos) 25 x3 copper strip 25 x 3 mm copper strip tinned at the points of contacts (Required length) 25 x 6 mm brass bolt & nut (Required quantity) 125 A, AC 23 A, 4 pole on-load COS (1 No) 3.5c 95sqmm cable (120 m) 3.15 mm copper conductor (10 SWG) (220 m) TESTING & COMMISIONING: Preparation of layout drawing, preparation of schematic drawing for obtaining approval from Electrical Inspectorate etc. Conducting load test of 82.5 KVA DG set using water load or electrical load at various step load, full load and 10% over load for minimum 3 hours including hire and labour charges of all required materials. Warrantee –2 year Comprehensive 24x7 onsite warrantee
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_452937.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .