Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹10.8 L+₹91,370 (9.26%)Rejected-Finance | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹12.6 L+₹2.7 L (27.3%)Rejected-Finance 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹13.8 L+₹4.0 L (40.1%)Rejected-Finance | L4 | Rejected-Finance Other Than L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
26 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(KH) YOL
GE(KH) YOL, YOL CANTT, HP
Repair/maintenance of electric UG cables, panels, bus bar at YOL CANTT under GE(KH) YOL CANTT
2022_MES_548458_1
GE/Y-26/2022-23
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(KH) YOL
₹20,000
Yes
10 Nov 2022
29 Aug 2022
28 Sept 2022
29 Aug 2022
26 Sept 2022
12 Sept 2022
Amount
Dismantling/ taking out old unserviceable cable of any size and removing from site, complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 240 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified. Note for Srl item Nos. 02 to 08:- (i) Excavation and earth work, sand cushioning & cable cover shall be measured and paid separately. (ii) All XLPE cable connected to any LT panel/bus bar should be proper size of cable gland and thimble including quoted rates.
Excavation in trenches n.exc 1.5 metres wide and n.exc 1.5 metres deep and getting out in any type of soil, all as specified.
Returning filling in including spreading leveling, watering and well ramming in layers n. exc 25cm, all as specified.
Removal of excavated material to be distance n.exc 50M and depositing where directed at a level n.exc 1.5m high from the starting point, all as specified.
Sand cushioning to under ground cables, 8cm thick layer before laying and testing the cable and 15cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I and directed by Engr-in-Charge.
Sub class 'B' bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Laying only retrived bricks as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Mild steel galvanised light grade 50mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Mild steel galvanised light grade 80mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Aluminium strip 25 x 3.15mm fixed on roof, pillars, wall etc, including porcelene isolater having not less than 50mm height with screws & saddles and placed at an interval not less than 50cm in such a manner that strip shoulde not touch the wall /roof/pillar surface etc,. for roof conductors and down conductors above ground above roof/wall/pole, complete fixed in repairs all as specified.
Supply and fixed in repair of single pointed air termination copper rod 12mm dia, 300mm long having one end flat with one 10mm dia hole fixing on roof top including fixing/fitting of termination rod at one end of GI pipe 25mm dia stand post with the help of nuts, bolts etc and making connection with roof/down conductors and making fixing arrangement of air termination rod over the GI pipe along with aluminium strip etc. all as specified and as directed.
Cable route indicator made out of 2mm thick mild steel of size 20cmx15cm duly coated with two coats of black paint over a coat of red oxide primer duly written the size of LT cable in white paint and welded to equal angle of size 30mmX30mmX3mm, 45cm long and errected in ground in such a way that it is 15cm above ground level and 30cm below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate of size 15cmx20cmx45xcmm, complete all as specified. Note: quoted rated including PCC and earth work, excavation.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm, including taking down old wire complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 16 sqmm, including taking down old wire complete all as specified.
Supply, installation, commissioning and testing bus bar chamber factory made Outdoor type, CPRI approved, size 0.45mx0.75mx0.4m deep, fabricated out of 3.15 mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement on angle iron legs made out of angle iron size 40mmx40mmx6mm, 8m long, 0.4m above ground level and 0.4m embedded in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate block of size 0.3mx0.3mx0.5m - 04 Nos, duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with aluminium bus bars of 200 Amps LED phase indicators, suitable for 3 phase 4 wire supply system with MCCB 125 Amp 4 pole breaking capacity 25 KA-01 No, duly drilled holes for cable connection mounted on epoxy based post insulator all as required at site, complete all as specified and directed. Note:- Contractor shall be submit the drg of bus bar chamber showing arrangments of MCCB, cable gallery, bus bar chambers over all dimensions and marked all items to be incorporated in to LT panel for approval of accepting officer, Engr In Charge shall ensure that LT bus bar shall be made as per drg only.
MCCB 4 pole with fixed thermal and fixed magnectic release, 400 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 250 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with thermal and fixed magnectic release, 160 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 100 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 63 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
Digital voltmeter of size 96x96sqmm, flush mounted type, 03 phase, class 0.5 fixed in repair complet all as specified.
Digital Ampere meter flush mounted, 03 phase, class 0.5 fixed in repair complet all as specified.
Lamp indicator flush mounted type model 03 phase, class 0.5 fixed in repair complet all as specified.
Supply and fixed in repair pole junction box sheet moulded compounded (SMC) type with hinged door and locking arrangement of size 200x140x95mm internal comprising One No. SP MCB 06 Amps capacity and One No. Bakelite based neutral link, One No. Earthing terminal and Four No. aluminium bus bar of suitable capacity including nuts, bolts, MS clamp etc, complete all as specified and directed.
Aluminium thimble suitable for 150mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 120mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 95mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 70mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 35mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 25mm XLPE cable, fixed in repair, complet all as specified.
M/S MALHI CONSTRUCTIONS
Eshaan Construction Co.
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .