| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC Contract awarded wef 01.10.2021. | |
| 2 | L2₹24.4 L+₹34,720 (1.44%)Rejected-Finance JALALIYA BUILDING 1ST FLOOR MASJID ROAD ALUVA ERNAKULAM 683101 | ALUVA | ERNAKULAM | KERALA | 683101 | L2 | Rejected-Finance 2.73 percentage below estimate | |
| 3 | L3₹25.9 L+₹1.9 L (7.91%)Rejected-Finance | L3 | Rejected-Finance 3.48 percentage above estimate | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically not qualified |
Tender Value
Refer Docs
Closing Date
29 Jun 2021, 3:00 pmClosed
AGM Land and Building
AGM LnB PGMT OFFICE THRISSUR
Providing maintenance of EA sets in various Telephone Exchange Buildings in THRISSUR BA for a period of 2 years - ESD II
2021_BSNL_76208_1
PGMT/LnB/ELECT/E-TENDER/MTCE EA/20-21/4dt 16.4.21
Open Tender
Electrical Works
Item Rate
730 days
Thrissur BA
As per NIT Document
2 documents required · 2 mandatory
₹590
Yes
BSNL
Exempted
17 Dec 2021
21 Apr 2021
30 Jun 2021
21 Apr 2021
29 Jun 2021
21 Apr 2021
21 Apr 2021 - 29 Jun 2021
Amount
Providing periodical preventive maintenance of E/A sets with standard control panel of following capacities as per the BSNL standard maintenance scope & conditions including topping up of battery water and coolant , replacing faulty V belts, flexible fuel pipe, flexible oil pipe, rubber hoses of water line etc, checking of panel including tightening of terminals, insulation checking of alternator, starting motor, charging alternator , oil quality and level checking including topping up etc. as reqd. (Periodic preventive maintenance site visit shall be done once in two months. However, breakdown maintenance shall be promptly attended as per the terms and conditions of the agreement)
Above 10 KVA and up to 15 KVA (per site once in two months)
Above 15 KVA and up to 30 KVA (per site once in two months)
Above 30 KVA and up to 40 KVA (per site once in two months)
Above 40 KVA and up to 63 KVA (per site once in two months)
Above 63 KVA and up to 100 KVA (per site once in two months)
Above 100 KVA and up to 160 KVA (per site once in two months)
Above 160 KVA and up to 250 KVA (per site once in two months)
Above 250 KVA and up to 350 KVA (per site once in two months)
Providing preventive maintenance of E/A sets with AMF control panel of following capacities as per the BSNL standard maintenance scope & conditions including topping up of battery water and coolant ,replacing faulty V belts, flexible fuel pipe, flexible oil pipe, rubber hoses of water line etc, checking of AMF panel including tightening of terminals, insulation checking of alternator, starting motor, charging alternator , oil quality and level checking including topping up etc. as reqd. (Periodic preventive maintenance site visit shall be done once in two months. However, breakdown maintenance shall be promptly attended as per the terms and conditions of the agreement)
Upto 10 KVA (per site once in two months)
Above 10 KVA and up to 15 KVA (per site once in two months)
Above 15 KVA and up to 30 KVA (per site once in two months)
Above 30 KVA and up to 40 KVA (per site once in two months)
Above 40 KVA and up to 63 KVA (per site once in two months)
Carrying out oil servicing of following capacity EA set i/c draining the existing lub oil and supplying and filling of superior quality and suitable grade for the engine lub oil, replacing of fuel filters, lub oil filters etc complete as per the maintenance schedule, terms and conditions and specifications attached.
Upto 10 KVA
Above 10 KVA and up to 15 KVA
Above 15 KVA and up to 30 KVA
Above 30 KVA and up to 40 KVA
Above 40 KVA and up to 63 KVA
Above 63 KVA and up to 100 KVA
Above 100 KVA and up to 160 KVA
Above 160 KVA and up to 250 KVA
Above 250 KVA and up to 350 KVA
The servicing of the EA sets has to be done once in a year or 500 hours and as per direction of Engineer in charge)
Part B
Supply and fixing of 12 V fully charged semi sealed maintenane free battery of automotive duty (for Engine Alternator sets) of the following capacities(On buy back basis) including transportation to site disconnecting and removing existing unserviceable battery giving connection with existing cables, testing, commissioning etc as required.(M/s Exide/SF or similar BSNL approved make)
NOTE: Faulty Batteries whose life has exceeded 3 years only are included in the scope of the above item. Faulty battery of less than 3 years shall be replaced by the maintenance contractor free of cost.
Rewinding of main stator winding of alternator of following capacity EA set including dismantling the Alternator, rewinding, refixing the same , loading unloading, trasnporation, testing and commissioning etc as reqd.
Upto 10 KVA
Above 10 KVA and up to 15 KVA
Above 15 KVA and up to 30 KVA
Above 30 KVA and up to 40 KVA
Above 40 KVA and up to 63 KVA
Above 63 KVA and up to 100 KVA
Above 100 KVA and up to 160 KVA
Above 160 KVA and up to 250 KVA
Above 250 KVA and up to 350 KVA
Replacement of faulty Microprocessor based AMF Controller with new one suitable for required capacity three phase EA set compatible for Water/Air cooled Engine in the existing AMF control panel including disconnecting and dismantling the faulty one, including providing and fixing all accessories, making necessary wiring arrangements including functional testing and commissioning as per site conditions and specifications attached. (Make:SIAS /Deep sea/Bernini/C&S )
Replacement of faulty contactor coil of suitable voltage for the existing Contactor of upo to 63A i/c dismantling the item, interconnections with suitable Copper cable including testing and commissioning as reqd. (Make:M/s L& T / Schneider Electric/ Siemens/Telemecanique)
Replacement of faulty Battery charger unit with new one, SMPS based, input voltage 170-260 V AC, 50 Hz, Output 12 V DC, 10 A suitable for Automotive battery including mounting, making connections, testing and commissioning as required.
Replacement of faulty Battery charger unit with new one, SMPS based, input voltage 170-260 V AC, 50 Hz, Output 24 V DC, 10 A suitable for Automotive battery including mounting, making connections, testing and commissioning as required.
Rewinding of faulty starting motor with copper conductor including baking / heating varnishing of EA sets upto 63 KVA etc as reqd
Rewinding of faulty starting motor with copper conductor including baking / heating varnishing of EA sets above 63 KVA upto 125 KVA etc as reqd
Rewinding of faulty starting motor with copper conductor including baking / heating varnishing of EA sets above 125 KVA upto 500 KVA etc as reqd
Supplying and Fixing 380mm sweep heavy duty fresh air fan in the existing DG set canopy i/c providing necessary clamping arrangement, nuts, bolts, giving connection etc complete as required. (Make : Almonard /s.s make )
Rewinding of 250/380mm sweep heavy duty fresh air fan /exhaust fan in the existing DG set canopy i/c to and fro transpoatation, fixing etc as required .
Supplying and fixing rubber type AVM pad suitable upto 60KVA Engine Alternator by lifting /raising the engine from base, dismatling the faulty one, fixing, testing,comissioning etc complete as required. (Make : Polybond/s.s make )
Supplying and fixing rubber type EA coupling upto 63 KVA E/A set i/c dismantling the faulty one as required .
Repairing of fuel injector of fuel injection pump as required(Rate is for servicing of each injector)
Replacement of the following spares of the E/A set for the smooth functioning of the system i/c checking the items and replacing the faulty one, giving necessary connections, testing and commissioning etc as reqd.
Hour meter
4 Pole, 415 V, 40 A Power contactor
4 Pole, 415 V, 63 A Power contactor
4 Pole, 415 V, 100 A Power contactor
Generator Safety Unit
Starting motor solenoid
LVM relay
START/STOP push button
START/STOP relay
Fuel gauge
12V, Stop solenoid
24V, Stop solenoid
63A, 4P, 2way + off, Changeover switch
Add on block (2NO+ 2NC)
Lug of battey cable
LLOP senser
HCT / HWT senser
12 V /24 V OEN/Pla relay plug in type
Electronic AVR suitable for EA set up to 63 KVA
Electronic AVR suitable for EA set above 63 KVA
63A, 4P, MCCB, 30KA breaking capacity. (Make L&T/SS)
Blower fan bearing
Mechanical interlock for 2 Nos, 32/63A, 4 Pole contactors
AMF relay board
EVR in AMF panel
Air ilter upto 30kVA
Air ilter above 30 to 100kVA
Arranging trolley mounted EA set of following capacity on rental basis including transportation, making connections etc complete as required
15 KVA EA set
30 KVA EA set
60 KVA EA set
Electro Guard Power Solutions
Vibrant Power Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .