Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 CrAccepted-AOC 102 SUBHASH ROAD HERITAGE HEIGHTS DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹6.9 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹7.1 Cr+₹25.6 L (3.72%)Rejected-Finance | ₹7.1 Cr+₹25.6 L (3.72%) | L2 | Rejected-Finance Highest Rate Quoted by bidder |
| 3 | L3₹7.1 Cr+₹25.8 L (3.75%)Rejected-Finance | ₹7.1 Cr+₹25.8 L (3.75%) | L3 | Rejected-Finance Highest Rate Quoted by bidder |
| 4 | L4₹7.4 Cr+₹51.6 L (7.48%)Rejected-Finance 11 NARENDRA VIHAR BALLUPUR ROAD DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹7.4 Cr+₹51.6 L (7.48%) | L4 | Rejected-Finance Highest Rate Quoted by bidder |
| 5 | L5₹7.6 Cr+₹70.2 L (10.2%)Rejected-Finance 112 RADHEY SHYAM VIHAR PHASE II MURAD NAGAR GHAZIABAD UP | GHAZIABAD | UP | ₹7.6 Cr+₹70.2 L (10.2%) | L5 | Rejected-Finance Highest Rate Quoted by bidder |
Tender Value
₹8.3 Cr
EMD Value
₹16.7 L
Closing Date
7 Jun 2021, 6:00 pmClosed
General Manager(Garhwal)
General Manager, Construction Wing, Uttarakhand Peyjal Nigam, 403/1 Indira Nagar, Dehradun
UPGRADATION OF BOXING HALL AT M.P.S.C, RAIPUR, DEHRADUN
2021_MDPEY_32382_1
1644/Nivida(Garh)Khel D.Dun /131 Dt 19-04-2021
Open Tender
Civil Works
Item Rate
420 days
RAIPUR
Please refer tender documents
3 documents required · 3 mandatory
₹14,160
PM, Temp.Const.Unit(Khel), UKPJN, Dehradun
₹16.7 L
Dehradun
24 Mar 2022
21 Apr 2021
9 Jun 2021
21 Apr 2021
7 Jun 2021
27 Apr 2021
26 Apr 2021
Amount
DSR Item No.- 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed by dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
DSR Item No.- 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
DSR Item No.- 5.22.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
DSR Item No.- 5.9 Centring and shuttering including strutting,ropping etc. and removal of form for
DSR Item No.- 5.9.1 Centring and shuttering for foundations, footings, bases of columns, etc. for mass concrete.
DSR Item No.- 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.
DSR Item No.- 5.9.3 Suspended floors, roofs, landings, balconies and access platform.
DSR Item No.- 5.38 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
DSR Item No.- 6.4.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand
DSR Item No.- 6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
DSR Item No.- 10.11.1 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
DSR Item No.- 10.25.2 Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
DSR Item No.- 10.25.1 Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete
DSR Item No.- 10.26.1 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube
DSR Item No.- 10.30.2 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes
DSR Item No.- 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
DSR Item No.- 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm
DSR Item No.- 13.1.2 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
DSR Item No.- 13.2.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
DSR Item No.- 13.8 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
DSR Item No.- 13.41.1 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade (New work (two or more coats) over and including priming coat with cement primer)
DSR Item No.- 13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm
DSR Item No.- 13.62.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
DSR Item No.- 12.54.2 Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier uspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
NSI Item- AcousticTreatmentonWalls:Providing&Fixingof3 4mm Acoustic Fabric as pe r approved coloron19mm Thick acoustic board as per Acutex make of approved NRC of 0.92 NRC with a density of400KG /m3 which the spread flame at termination/10Min with a FR report on basis of Class-1& Also the spread flame at1.5 min should be nilas per FR Test Reports.The Acoustic Board will be fix tothe Frame of of 45mm x45mm x0.4mm with Stud at 600mm x600mm Center to Center or as per site requirement.The Center to be filled with 50mmThick Polyester Fiber Insulation With Anti-Vibration Pads (Wherever Require).
NSI Item- Providing and installing 20mm maple wooden flooring providing & laying MFMA Accredited American Hard Maple of 20mmx57/83mm widthxrandom Length 300mm onwards tongue & grooved for concealed fastening with cleats at every juncture with the pine runner (moisture contents<14) of 68x38x900/1200mm cushion pad fixed at every joint of the runner & at 330 centre to centre. the full build up will be of 94/95 which will laid on 6 mm thick plastic sheet (HDPE)as moisture barrier. Marine plywood of 12 MM or more thickness shall laid in between pine runners and maple wood flooring.
DSR Item No.- 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
DSR Item No.- 21.12.3 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.
DSR Item No.- 21.1.1.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
DSR Item No.- 21.3.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
DSR Item No.- 7.40.1 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone
DSR Item No.- 22.14.1 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
DSR Item No.- 10.2 Structrural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting fixing in position and applying a priming coat of approved steel primer all complete.
DSR Item No.- 12.4.1 Providing ridges or hips of width 60 cm over all width plain G.S sheet fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia. G.I limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275gm/sqm.
DSR Item No.- 12.50.1 Supply & installation of precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm +/- 5% total coated thickness (TCT) thick Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
DSR Item No.- 12.51.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT) thick Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Ridges plain (500 - 600mm).
DSR Item No.- 13.62.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
DSR Item No.- 2.6.1 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
DSR Item No.- 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
DSR Item No.- 2.27 Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete.
DSR Item No.- 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
DSR Item No.- 5.1.2 Providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
DSR Item No.- 5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
DSR Item No.- 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :
DSR Item No.- 18.32.1 Constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1cement :4 coarse sand ) with C.c 1:2:4 floor over C.C 1:5:10 Finished with a floating coat of neat cement complete .Rectangular shape 600x450mm internal dimensions
DSR Item No.- 9.5 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete.
DSR Item No.-19.2 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg
DSR Item No.- 16.3.1 Supplying and stacking at site. Over burnt (Jhama) brick aggregate 90 mm to 45 mm
DSR Item No.- 19.6.3 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
NSI Item- GRAVEL
NSI Item- Gravel 5 mm to 10 mm
NSI Item- Gravel 3 mm to 6 mm
NSI Item- PEA Gravel
DSR Item No- 8.18.1.1 Stone work (machine cut edges Veneer work) for wall lining upto 10 m height, backing filled with a grout of 12 mm thick cement mortar 1:3 (1 Cement : 3 coarse sand) and jointed with Cement mortar 1:2 (1 cement : 2 stone dust), including rubbing and polishing complete. (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately). Kota stone slabs exposed face dressed and rubbed. 25 mm thick
DSR Item- 2.2 Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
DSR Item No- 15.7.4 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
DSR Item No- 15.2.2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
DSR Item No- 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
DSR Item No- 15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
DSR Item No- 15.12.1 Of area 3 sq. metres and below
DSR Item No- 15.12.2 Of area beyond 3 sq. metres
DSR Item No- 15.18 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
DSR Item No- 15.20 Extra for dismantling trusses, rafters, purlins etc. of steel work for kg per every additional span of one metre or part thereof beyond 10 metres
DSR Item No- 15.21 Extra for dismantling trusses, rafters, purlins etc. of steel work for kg per every additional height of one metre or part thereof beyond 5 metres
DSR Item No- 15.22 Extra for marking of structural steel work required to be re-erected
DSR Item No-15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
DSR Item No- 15.28.1 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
NSI Item- Fixing of rebar 10mm dia, depth 100mm with hilti chemical including drilling holes and filling chemical complete for R.C.C. works i.e., beam, slab, columns etc.all as specified and directed by Engineer-in-charge.
NSI Item- Fixing of rebar 12mm dia, depth 120mm with hilti chemical including drilling holes and filling chemical complete for R.C.C. works i.e., beam, slab, columns etc. all as specified and directed by Engineer-in-charge.
NSI Item- Fixing of rebar 16mm dia, depth 160mm with hilti chemical including drilling holes and filling chemical complete for R.C.C. works i.e., beam, slab, columns etc. all as specified and directed by Engineer-in-charge.
NSI Item- Fixing of rebar 20 mm dia, depth 200mm with hilti chemical including drilling holes and filling chemical complete for R.C.C. works i.e., beam, slab, columns etc. all as specified and directed by Engineer-in-charge.
NSI Item- Supply and installation of Mounting Arrangements for Sports Lighting with nuts, bolts and washers as per instructions of Engineer-in-charge.
NSI Item- Supply and laying of cabling of approved brand 1. 2.5 sqmm 3 core for hall lighting, 2. 6 sqmm, 4 core for Main Panel feeder cable as per instructions of Engineer-in- charge.
NSI Item- Supply, Installation, testing and commissioning of Control Panel. Control Panel Specifications as follows: 1. MCCB 160 A, TP, with Thermal Magnetic Release (Brand L&T) 2. Indicating Light 220 Vac RED, (Main R- Phase) 3. Indicating Light 220 Vac Yellow, (Main Y-Phase) 4. Indicating Light 220 Vac Blue, (Main B- Phase) 5. Digital VAF Meter size 96 × 96 6. CT 200/5, 5 VA, CL-1 as per Instruction of Engineer-in-Charge
NSI Item- Earthing of Panel as per instructions of Engineer-in-charge
NSI Item- Design, supply, erection, testing and commissioning of indoor LED Sports lights, including lights, fixing arrangements, electrical cabling, central control panel and all accessories etc., complete, required for proper completion of work, as per illumination (>20000 lux) national games level Netball indoor stadium. The lights, electrical equipments and accessories all have to be designed from recognized sports light designers (including vetting from ISLE / IIT or equivalent institution / organization). The hight of lights from play surface shall be more than 12 M. Supply and installation (tentative approximately 75000 Lumens, 500 W, 77 Nos Indoor, Honeycomb anti-glare protection, but final lumens/lux/W/No of luminaries as per design) in indoor stadium. (See other details in specifications.)
NSI Item- Design, supply, erection, testing and commissioning of indoor FDV Units ( Force draft ventilation ) Supply installation testing and commissioning of single skin FDV unit with non thremal break profile 24 G GI outside sheet with precoating and with flowing section.Complete with fan section with DIDW forward curved centrifugal fan,drive motors and accessories.frame work shall be of Anodized Aluminum construction with Non thermal break profile.Pre filter section with 98% Efficiency filter rating. A- Floor Mounted Units, B- 20000 CFM @ 55 MM WC
NSI Item- Complete with celdek section- 150 mm thick Cellulose based Evaporative Pad,, water recirculation monobloc pump, with necessary piping, valves, SS-304 water tank, water distribution piping, nozzles suitable for FDV unit.
NSI Item- Casing made from mild steel plates and sheets reinforced with angle Iron.Its design is involute scroll for giving maximum efficiency . Suction is done with round flanged with supported fins to the cover and outlet is generally rectangular with extra support of angle on the casing . Minimum thickness of sheet is used in the casing 2.5 mm with maximum thickness goes to 3 mm MS sheet. The fourth quarter of casing is much larger as compaired to the other fans to get the maximum efficiency and free flow of air to be dragged from the outlet . Impeller is of enclosed design made from mild steel sheets . It is designed for giving maximum efficiency for the designed head and volume . Impeller curve is of BACKWARD/FORWORD CURVED and the blade angle is of 56 degree to 48 degree . The Hub which is connected the impeller to the motor shaft is of Ms casting and the designed of the hub is beak type to get the maximum air flow at the center of the impeller .MOTOR PEDESTAL is of mild steel reinforced with heavy angles . Its box section is welded to the casing so that all the center of mass will on the same base. IMPELLER is 100% dynamically as well as statically balanced thru ABRO BALANCING MACHINE with upto 0.001 gms in polar coordinates weight. STANDARD blowers, fans and exhausters are very ruggedly built , so that they withstand rough handling and can be used in duty atmospheres. Each blower , fans or exhauster is properly tested in our works Prior to dispatch. Exhaust air unit 18000 cfm/ 1400 rpm
NSI Item- Fabrication, supply, installation, testing & commissioning of Galvanised Iron (GI) GI Sheet ducting complete with nut bolt, gaskit, silicon sealent duct supports etc. as per drawings and specifications. .
NSI Item- 20 Gauge (Thickness 1.0mm)
NSI Item- 22 Gauge (Thickness 0.8mm)
NSI Item- 24 Gauge ( Thickness 0.63mm)
NSI Item- Supply, fixing and commissioning of Double deflection , powder coated extruded aluminum grilles complete with black anodized extruded aluminum VCD, nuts, bolts, screws etc. as per approved drawings and specifications. (1200 MM X 250 MM) Supply air grilles with Collar Box type damper.
NSI Item- Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
NSI Item- Gravity louvers. Supply, installation, testing and commissioning of Gravity louvers
NSI Item- Canvass Connections. Supply, installation, testing and commissioning of Flexible double Canvass Connections for FDV units
NSI Item- S.I.T.C. of Duct insulation with following type fixed with adhesive as per manufacturers specs or using 9 mm thick closed cell cross-linked polyethylene FR XPE ( External of Supply DUCT)
NSI Item- Supply of Acoustic lining of duct work with following type 15 mm thick open cell nitrile rubber Internal of DUCT)
NSI Item- Supply of electrical Starter suitable for following: Floor Mounted FDV unit,
NSI Item- 20,000 CFM at 35 MM WC
NSI Item- 18,000 CFM /1400 rpm
DSR Item No.- 1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group C
DSR Item No.- 1.11 Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
DSR Item No.- 1.12 Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
DSR Item No.- 1.14 Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
DSR Item No.- 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
DSR Item No.- 1.14.2 2x2.5 sq. mm + 1x2.5 sq.mm earth wire
DSR Item No.- 1.14.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
DSR Item No.- 1.14.10 4x10 sq. mm + 2x 6 sq.mm earth wire
DSR Item No.- 1.18.2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
DSR Item No.- 1.21.2 Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required.25mm
DSR Item No.- 1.22.1 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
DSR Item No.- 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
DSR Item No.- 1.24.1 5/6 amps switch
DSR Item No.- 1.24.4 3 pin 5/6 amp socket outlet
DSR Item No.- 1.24.6 Telephone socket outlet
DSR Item No.- 1.25 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
DSR Item No.- 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
DSR Item No.- 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
DSR Item No.- 1.33 Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
DSR Item No.- 1.34 Supplying and flxing brass batten/angle holder including connection etc. as required.
DSR Item No.- 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
DSR Item No.- 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
DSR Item No.- 1.50 Installation of exhaust fan upto 450 mm sweep in the existingopening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
DSR Item No.- 1.51 Extra for fixing louvers/shutters complete with frame for a exhaust fan of all sizes.
DSR Item No.- 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
DSR Item No.- 2.4.3 8 way (4 + 24), Double door
DSR Item No.- 2.4.2 6 way (4 + 18), Double door
DSR Item No.- 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
DSR Item No.- 2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required.63 amps
DSR Item No.- 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required..
DSR Item No.- 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
DSR Item No.- 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.( For D.G Set & CSS)
DSR Item No.- 5.10 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
DSR Item No.- 4.1 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
DSR Item No.- 4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.1.3 225 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.1.5 375 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.1.6 450 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.1.7 600 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.1.16 900 mm width X 75 mm depth X 2.0 mm thickness
DSR Item No.- 4.2 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
DSR Item No.- 4.2.1 100 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.2.2 150 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.2.3 225 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.2.4 300 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.2.5 375 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.2.6 450 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.2.7 600 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.2.16 900 mm width X 75 mm depth X 2.0 mm thickness
DSR Item No.- 4.3 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
DSR Item No.- 4.3.1 100 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.3.2 150 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.3.3 225 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.3.4 300 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.3.5 375 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.3.6 450 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.3.7 600 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.3.16 900 mm width X 75 mm depth X 2.0 mm thickness
DSR Item No.- 4.4 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
DSR Item No.- 4.4.1 100 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.4.2 150 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.4.3 225 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.4.4 300 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.4.5 375 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.4.6 450 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.4.7 600 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.4.16 900 mm width X 75 mm depth X 2.0 mm thickness
DSR Item No.- 4.5 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
DSR Item No.- 4.5.1 100 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.5.2 150 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.5.3 225 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.5.4 300 mm width X 50 mm depth X 1.6 mm thickness
DSR Item No.- 4.5.5 375 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.5.6 450 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.5.7 600 mm width X 50 mm depth X 2.0 mm thickness
DSR Item No.- 4.5.16 900 mm width X 75 mm depth X 2.0 mm thickness
DSR Item No.- 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
DSR Item No.- 7.1.1 Upto 35 sq. mm
DSR Item No.- 7.1.2 Above 35 sq. mm and upto 95 sq. mm
DSR Item No.- 7.1.3 Above 95 sq. mm and upto 185 sq. mm
DSR Item No.- 9.4 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
DSR Item No.- 9.4.17 3½ X 25 sq. mm
DSR Item No.- 9.4.18 3½ X 35 sq. mm
DSR Item No.- 9.4.19 3½ X 50 sq. mm
DSR Item No.- 9.4.20 3½ X 70 sq. mm
DSR Item No.- 9.4.21 3½ X 95 sq. mm
DSR Item No.- 9.4.27 3½ X 300 sq. mm
DSR Item No.- 14.13 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required
DSR Item No.- 14.13.2 80 mm dia
DSR Item No.- 14.13.3 100 mm dia
DSR Item No.- 15.3 Supplying,installation,testing andcommissioning of Microwave technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 A, for mounting height up to 2.6 meter and for 5m X 20m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
DSR Item No.- 3.3 Supplying, installing, testing and commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required.
DSR Item No.- 3.3.3 16 A, TPN, 6 way
DSR Item No.- 3.3.6 32 A, TPN, 4 way
DSR Item No.- 3.3.10 63 A, TPN, 4 way
NSI Item- Supply of AC 230/250 volts, 50 HZ energy efficient ceiling fan with standard down rod, blades, 3 nos. caps Model-Captiva 50 (1200 mm Sweep) etc. complete in all aspects as per direction of Engineer in Charge. 1200 mm sweep
NSI Item- Supply of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete . Model- Ventil Air - DS (Make : Finolex) 300 mm sweep 900 rpm ,complete in all aspects as per direction of Engineer in Charge. 300 mm sweep 900 rpm
NSI Item- Supply of heavy duty wall mounted fan - 400 mm dia Model - (Finspeed Wall) complete in all aspects etc. as per direction of Engineer in Charge. (Make : Havells)
NSI Item- SUPPLY OF LED Glass Bulb B22, 12 W ,6000k /4000k/3000K ,230/250 Volt,50 HZ ETC, complete in all aspects as per direction of Engineer in Charge.
NSI Item- Supply and fixing of T5 LEDTube Light -Wall mounted LED batten , extruded aluminium Heat sink provided for efficient heat dissipation & integrated electronic driver. (1X22W LED )complete in all aspects as per direction of Engineer in Charge
NSI Item- Supply & fixing of Ceiling concealed Light Recess mounting luminiare suitable for Armstrong / Grid/ Ceiling Concealed Light 12W LED Concealed Round shaped Panel Light with adopter of standard make (Havell's / Bajaj) complete in all aspects like Ballast , housing connecting wire etc. as per direction of Engineer in Charge.
NSI Item- Supply & fixing of Ceiling Light - RC380B LED34S-6500 G3 PSU OD Recess mounting luminiare suitable for Armstrong / Grid/ Ceiling (600X600mm) with electronic driver & high Brightness SMD LED's. Lamp Type 32 Watt LED 4000 ,6500 K . High efficiency diffuser IP 20 of standard make (Philips) complete in all aspects like Ballast , housing connecting wire etc. as per direction of Engineer in Charge
NSI Item- Supply & fixing of LED Mirror Light -Providing & Installation of Factory packed ready to installed LED mirror light with LED Lamp not less than 4 Watt diffused optics complete in all aspects including base plate (for recess in wall ) connecting wire etc.of as per direction of Engineer in Charge. .
NSI Item- Supply & fixing of main panel with 1 no. incomer of 400 amp.TPN MCCB (25 KA)& outgoings of 03 no. 100 amp. FP MCB (25 KA) & 04 no. outgong of 63 amp. FP MCB with suitable busbar, change over switch,ammeter, voltmeter,indicating lamps etc. complete in all respect.
NSI Item- Supply,of following sizes of PVC sheathed LT XLPE armoured, aluminium 1.1KV grade, as required of the following sizes.
3.5c x 185 sq. mm cable
4c x 95 sq. mm cable
3.5 c x 70 sq.mm cable
3.5 c x 35 sq.mm cable
3.5 c x 25 sq.mm cable
4c x 10 sq. mm cable
4c x 6 sq. mm cable
SURI CONSTRUCTIONS
M/s Gautam Construction
Makin Developers Pvt. Ltd.
RP INFRAPOWER PVT LTD
M/s Mahalaxmi Construction
unipro techno infrastructure pvt ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .